LCA100 Single Pole OptoMOS(R) Relay Load Voltage Load Current Max RON LCA100 350 120 25 Description LCA100 is a 350V, 120mA, 25 1-Form-A relay. It features the lowest on-resistance in an OptoMOS relay with 350V peak load voltage. Current limiting version is also available. ("L" suffix) Units V mA Features * Small 6 Pin DIP Package * Low Drive Power Requirements (TTL/CMOS Compatible) * No Moving Parts * High Reliability * Arc-Free With No Snubbing Circuits * 3750VRMS Input/Output Isolation * FCC Compatible * VDE Compatible * No EMI/RFI Generation * Machine Insertable, Wave Solderable * Surface Mount and Tape & Reel Versions Available Approvals * UL Recognized: File Number E76270 * CSA Certified: File Number LR 43639-10 * BSI Certified to: * BS EN 60950:1992 (BS7002:1992) Certificate #: 7344 * BS EN 41003:1993 Certificate #: 7344 Ordering Information Applications * Telecommunications * Telecom Switching * Tip/Ring Circuits * Modem Switching (Laptop, Notebook, Pocket Size) * Hookswitch * Dial Pulsing * Ground Start * Ringer Injection * Instrumentation * Multiplexers * Data Acquisition * Electronic Switching * I/O Subsystems * Meters (Watt-Hour, Water, Gas) * Medical Equipment--Patient/Equipment Isolation * Security * Aerospace * Industrial Controls Part # LCA100 LCA100S LCA100STR Description 6 Pin DIP (50/Tube) 6 Pin Surface Mount (50/Tube) 6 Pin Surface Mount (1000/Reel) Pin Configuration LCA100/LCA100L Pinout DC Only Configuration + Control - Control Do Not Use 1 6 2 5 3 4 + Load - Load Switching Characteristics of Normally Open (Form A) Devices 10ms CONTROL LOAD 10%+ DS-LCA100-R1 www.clare.com +90% 10%+ TON TOFF 1 LCA100 Absolute Maximum Ratings (@ 25 C) Parameter Min Input Power Dissipation - - 1501 mW Input Control Current Peak (10ms) - - 50 1 mA A Reverse Input Voltage - - 5 V - - 8002 mW Total Power Dissipation Isolation Voltage Input to Output 3750 - - VRMS Operational Temperature -40 - +85 C Storage Temperature -40 - +125 C - - +260 +220 C C Soldering Temperature (10 Seconds Max.) DIP Package Surface Mount Package 1 Derate Linearly 1.33 mw/C 2 Derate Linearly 6.67 mw/C Absolute Maximum Ratings are stress ratings. Stresses in excess of these ratings can cause permanent damage to the device. Functional operation of the device at these or any other conditions beyond those indicated in the operational sections of this data sheet is not implied. Exposure of the device to the absolute maximum ratings for an extended period may degrade the device and effect its reliability. Typ Max Units Electrical Characteristics Parameter Conditions Symbol Min Typ Max Units Load Voltage (Peak) - VL - - 350 V Load Current (Continuous) AC/DC Configuration DC Configuration - IL IL - - 120 200 mA mA 10ms ILPK - - 350 mA On-Resistance AC/DC Configuration DC Configuration IL=120mA IL=200mA RON RON - - 25 8 Off-State Leakage Current Output Characteristics @ 25C Peak Load Current VL=35OV ILEAK - - 1 A Switching Speeds Turn-On Turn-Off IF=5mA, VL=10V IF=5mA, VL=10V TON TOFF - - 5 5 ms ms Output Capacitance 50V; f=1MHz COUT - 35 - pF IL=120mA IF 5 - 50 mA Input Characteristics @ 25C Input Control Current Input Dropout Current - IF 0.4 0.7 - mA IF=5mA VF 0.9 1.2 1.4 V Reverse Input Voltage - VR - - 5 V Reverse Input Current VR=5V IR - - 10 A Input to Output Capacitance - CI/O - 3 - pF Input to Output Isolation - VI/O 3750 - - VRMS Input Voltage Drop 2 www.clare.com Rev. 1 LCA100 PERFORMANCE DATA* Device Count (N) 25 20 15 10 5 35 35 30 30 25 20 15 10 5 0 1.19 1.21 1.23 1.25 10 0 369.8 374.6 379.4 384.1 388.9 393.7 398.4 Blocking Voltage (V) LCA100 Typical Turn-On Time (N=50 Ambient Temperature = 25C) (Load Current = 120mADC; IF = 5mADC) LCA100 Typical IF for Switch Dropout (N=50 Ambient Temperature = 25C) (Load Current = 120mADC) 25 25 20 20 20 15 10 5 0 Device Count (N) 25 Device Count (N) Device Count (N) 15 On-Resistance () LCA100 Typical IF for Switch Operation (N=50 Ambient Temperature = 25C) (Load Current = 120mADC) 15 10 5 0 0.85 0.90 0.95 1.00 1.05 1.10 1.15 Load Current (mA) 20 15 10 5 0.90 0.95 1.00 1.05 1.10 1.72 1.15 180 0.016 160 0.014 140 0.012 120 100 20mA 10mA 5mA 80 60 0.17 -20 0 LCA100 Typical Blocking Voltage vs. Temperature 3.000 405 2.500 Turn-On (ms) 400 395 390 385 20 40 60 80 100 -40 -20 0 20 40 60 Temperature (C) 80 100 0.010 0.008 0.006 -40 0 20 40 60 80 100 LCA100 Typical Turn-On vs. Temperature (Load Current = 120mADC) LCA100 Typical Turn-Off vs. Temperature (Load Current = 100mADC) 5mA 2.000 1.500 10mA 20mA 1.000 -40 -20 Temperature (C) 0 375 2.61 0 120 0.500 380 2.46 Temperature (C) Turn-Off (ms) 410 2.32 0.002 -40 0.19 2.17 0.004 40 -20 0 20 40 60 80 100 120 Temperature (C) Turn-Off (ms) 0.15 2.02 LCA100 Typical Leakage vs. Temperature (Measured across Pins 4 & 6) 0 0 0.13 1.87 Turn-On (ms) 20 0.10 5 LCA100 Typical Load Current vs. Temperature 25 0.08 10 LED Current (mA) LCA100 Typical Turn-Off Time (N=50 Ambient Temperature = 25C) (Load Current = 120mADC; IF = 5mADC) 0.06 15 0 0.85 LED Current (mA) Device Count (N) 20 13.93 14.05 14.17 14.29 14.41 14.54 14.66 LED Forward Voltage Drop (V) Blocking Voltage (VRMS) 25 5 0 1.17 Leakage (A) Device Count (N) 30 LCA100 Typical Blocking Voltage Distribution (N=50 Ambient Temperature = 25C) Device Count (N) 35 LCA100 Typical On-Resistance Distribution (N=50 Ambient Temperature = 25C) (Load Current = 120mADC) LCA100 Typical LED Forward Voltage Drop (N=50 Ambient Temperature = 25C) IF = 5mADC 0.50 0.45 0.40 0.35 0.30 0.25 0.20 0.15 0.10 0.05 0 -40 -20 0 20 40 60 80 100 120 Temperature (C) The Performance data shown in the graphs above is typical of device performance. For guaranteed parameters not indicated in the written specifications, please contact our application department. Rev. 1 www.clare.com 3 LCA100 PERFORMANCE DATA* 3.0 0.30 1.6 2.5 0.25 1.4 50mA 30mA 20mA 10mA 5mA 1.2 2.0 1.5 1.0 1.0 0.5 0.8 0 -20 0 20 40 60 80 100 Turn-Off (ms) 1.8 -40 120 0.15 0.10 0 0 5 10 15 20 25 30 35 40 45 50 0 LCA100 Typical IF for Switch Operation vs. Temperature (Load Current = 120mADC) 4.0 10 LED Current (mA) 5.0 4.0 LED Current (mA) 5.0 15 3.0 2.0 1.0 5 -20 0 20 40 60 80 100 120 -40 Temperature (C) Load Current (A) 100 50 0 -50 -100 -150 -2 -1 0 1 Load Voltage (V) 2 3 25 30 35 40 45 50 3.0 2.0 1.0 0 20 40 60 80 100 120 -40 -20 0 20 40 60 80 100 120 Temperature (C) LCA100 Energy Rating Curve 150 -3 -20 Temperature (C) LCA100 Typical Load Current vs. Load Voltage (Ambient Temperature = 25C) IF = 5mADC 20 0 0 0 15 LCA100 Typical IF for Switch Dropout vs. Temperature (Load Current = 120mADC) 25 20 10 LED Forward Current (mA) 30 -40 5 LED Forward Current (mA) LCA100 Typical On-Resistance vs. Temperature (Load Current = 120mADC; IF = 5mADC) On-Resistance () 0.20 0.05 Temperature (C) Load Current (mA) LCA100 Typical Turn-Off vs. LED Forward Current (Load Current = 120mADC) LCA100 Typical Turn-On vs. LED Forward Current (Load Current = 120mADC) Turn-On (ms) LED Forward Voltage Drop (V) LCA100 Typical LED Forward Voltage Drop vs. Temperature 1.0 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 10s 100s 1ms 10ms 100ms 1s 10s 100s Time The Performance data shown in the graphs above is typical of device performance. For guaranteed parameters not indicated in the written specifications, please contact our application department. 4 www.clare.com Rev. 1 LCA100 Mechanical Dimensions 8.382 .635 (.330 .025) 6 Pin DIP Through Hole (Standard) 2.540 .127 (.100 .005) 7.620 .254 (.300 .010) 7.239 TYP. (.285) 3.302 (.130) 6.350 .127 (.250 .005) 9.144 .508 (.360 .020) 7.620 .127 (.300 .005) 5.080 .127 (.200 .005) PC Board Pattern (Top View) 2.540 .127 2.540 .127 (.100 .005) (.100 .005) 9.525 .254 (.375 .010) 6.350 .127 (.250 .005) 3.302 (.130) 2.540 .127 (.100 .005) 6.350 .127 (.250 .005) 9.144 (.360) 8.382 .635 (.330 .025) 7.620 .254 (.300 .010) .635 TYP. (.025) 6-.800 DIA. (6-.031 DIA.) .457 .076 (.018 .003) 6 Pin DIP Surface Mount ("S" Suffix) 4.445 .127 (.175 .005) PC Board Pattern (Top View) 8.305 .127 (.327 .005) 1.905 .127 (.075 .005) .254 TYP. (.010) .457 .076 (.018 .003) 1.499 .127 (.059 .005) Tape and Reel Packaging for 6 Pin Surface Mount Package 330.2 DIA. (13.00) Top Cover Tape Thickness .102 MAX. (.004) 6.731 MAX. 1.753 .102 (.265) (.069 .004) .406 MAX. (.016) 2.007 .102 1.498 .102 3.987 .102 (.079 .004) (.059 .004) (.157 .004) 7.493 .102 (.295 .004) 1 6 12.090 (.476) 10.100 (.398) 4.877 (.192) Top Cover Tape Embossed Carrier 16.002 .305 (.630 .012) .050R TYP. 11.989 .102 (.472 .004) 10.100 .102 (.398 .004) 1.549 .102 (.061 .004) User Direction of Feed Embossment Dimensions mm (inches) Rev. 1 www.clare.com 5 For additional information please visit our website at: www.clare.com Clare, Inc. makes no representations or warranties with respect to the accuracy or completeness of the contents of this publication and reserves the right to make changes to specifications and product descriptions at any time without notice. Neither circuit patent licenses nor indemnity are expressed or implied. Except as set forth in Clare's Standard Terms and Conditions of Sale, Clare, Inc. assumes no liability whatsoever, and disclaims any express or implied warranty, relating to its products including, but not limited to, the implied warranty of merchantability, fitness for a particular purpose, or infringement of any intellectual property right. The products described in this document are not designed, intended, authorized or warranted for use as components in systems intended for surgical implant into the body, or in other applications intended to support or sustain life, or where malfunction of Clare's product may result in direct physical harm, injury, or death to a person or severe property or environmental damage. Clare, Inc. reserves the right to discontinue or make changes to its products at any time without notice. Specification: DS-LCA100-R1.0 (c)Copyright 2002, Clare, Inc. All rights reserved. Printed in USA. 6/25/02