Computer Cable
MULTICONDUCTOR UNSHIELDED CABLE
Standard
Putups:
100 ft.
500 ft.
1000 ft.
bulk.
See color charts
1, 2 or 3 (as
noted) in
Technical
Section.
Conductors: Stranded tinned copper.
Insulation: Color coded polyvinylchloride.
Jacket: Chrome polyvinylchloride.
Temperature: 80C AWM; 90C CL2.
Voltage Rating: 300 Volts AWM.
Resistant To: Acid, alkalis, oil, moisture, solvents and fungus.
Designed for control processing, communications, instrumentation, and
audio systems. *Internal wiring or external interconnection of electronic
equipment.
UL: 2464
CSA: AWM II A/B FT4
Recognized under the components program of Underwriters'
Laboratories, Inc. UL Style 2464 80C 300V. CSA AWM II A/B FT4.
NEC Type CL2. Passes VW-1 Vertical Flame Test. OSHA Acceptable.
Part Number No. of
Conductors AWG Stranding Nom. Dia. of
Conductor
in. mm
Nom. Insulation
Thickness
in. mm
Nom. Jacket
Thickness
in. mm
Nom. O.D.
in. mm Color Code
882402 2 24 7/32 .024 0.61 .010 0.25 .032 0.81 .160 4.06 3
882403 3 24 7/32 .024 0.61 .010 0.25 .032 0.81 .165 4.19 3
882404 4 24 7/32 .024 0.61 .010 0.25 .032 0.81 .180 4.57 3
882406 6 24 7/32 .024 0.61 .010 0.25 .032 0.81 .205 5.21 3
882408 8 24 7/32 .024 0.61 .010 0.25 .032 0.81 .220 5.59 3
Part Number No. of
Conductors AWG Stranding Nom. Dia. of
Conductor
in. mm
Nom. Insulation
Thickness
in. mm
Nom. Jacket
Thickness
in. mm
Nom. O.D.
in. mm Color Code
882410 10 24 7/32 .024 0.61 .010 0.25 .032 0.81 .245 6.22 3
882415 15 24 7/32 .024 0.61 .010 0.25 .032 0.81 .275 6.99 3
882420 20 24 7/32 .024 0.61 .010 0.25 .032 0.81 .300 7.62 3
882425 25 24 7/32 .024 0.61 .010 0.25 .032 0.81 .340 8.64 3
882430 30 24 7/32 .024 0.61 .010 0.25 .032 0.81 .360 9.14 3
Part Number No. of
Conductors AWG Stranding Nom. Dia. of
Conductor
in. mm
Nom. Insulation
Thickness
in. mm
Nom. Jacket
Thickness
in. mm
Nom. O.D.
in. mm Color Code
882440 40 24 7/32 .024 0.61 .010 0.25 .032 0.81 .400 10.16 3
882450 50 24 7/32 .024 0.61 .010 0.25 .032 0.81 .440 11.18 3
882460 60 24 7/32 .024 0.61 .010 0.25 .032 0.81 .470 11.94 3
882470 70 24 7/32 .024 0.61 .010 0.25 .032 0.81 .510 12.95 3
882480 80 24 7/32 .024 0.61 .010 0.25 .032 0.81 .530 13.46 3
Part Number No. of
Conductors AWG Stranding Nom. Dia. of
Conductor
in. mm
Nom. Insulation
Thickness
in. mm
Nom. Jacket
Thickness
in. mm
Nom. O.D.
in. mm Color Code
882490 90 24 7/32 .024 0.61 .010 0.25 .032 0.81 .560 14.22 3
882400 100 24 7/32 .024 0.61 .010 0.25 .050 1.27 .640 16.26 3
882202 2 22 7/30 .030 0.76 .010 0.25 .032 0.81 .160 4.06 1
882203 3 22 7/30 .030 0.76 .010 0.25 .032 0.81 .164 4.17 1
882204 4 22 7/30 .030 0.76 .010 0.25 .032 0.81 .182 4.62 1
Part Number No. of
Conductors AWG Stranding Nom. Dia. of
Conductor
in. mm
Nom. Insulation
Thickness
in. mm
Nom. Jacket
Thickness
in. mm
Nom. O.D.
in. mm Color Code
882205 5 22 7/30 .030 0.76 .010 0.25 .032 0.81 .194 4.93 1
882206 6 22 7/30 .030 0.76 .010 0.25 .032 0.81 .205 5.21 1
882207 7 22 7/30 .030 0.76 .010 0.25 .032 0.81 .214 5.44 1
882208 8 22 7/30 .030 0.76 .010 0.25 .032 0.81 .229 5.82 1
882209 9 22 7/30 .030 0.76 .010 0.25 .032 0.81 .244 6.20 1
Part Number No. of
Conductors AWG Stranding Nom. Dia. of
Conductor
in. mm
Nom. Insulation
Thickness
in. mm
Nom. Jacket
Thickness
in. mm
Nom. O.D.
in. mm Color Code
882210 10 22 7/30 .030 0.76 .010 0.25 .032 0.81 .264 6.71 1
882212 12 22 7/30 .030 0.76 .010 0.25 .032 0.81 .272 6.90 1
882215 15 22 7/30 .030 0.76 .010 0.25 .032 0.81 .330 8.38 2
882218 18 22 7/30 .030 0.76 .010 0.25 .032 0.81 .340 8.63 2
882220 20 22 7/30 .030 0.76 .010 0.25 .032 0.81 .345 8.76 2
Part Number No. of
Conductors AWG Stranding Nom. Dia. of
Conductor
in. mm
Nom. Insulation
Thickness
in. mm
Nom. Jacket
Thickness
in. mm
Nom. O.D.
in. mm Color Code
882225 25 22 7/30 .030 0.76 .010 0.25 .040 1.02 .370 9.40
882230 30 22 7/30 .030 0.76 .010 0.25 .032 0.81 .400 10.16 2
882240 40 22 7/30 .030 0.76 .010 0.25 .032 0.81 .455 11.56 2
882250 50 22 7/30 .030 0.76 .010 0.25 .032 0.81 .500 12.70 2
882260 60 22 7/30 .030 0.76 .010 0.25 .032 0.81 .536 13.61 2
Part Number No. of
Conductors AWG Stranding Nom. Dia. of
Conductor
in. mm
Nom. Insulation
Thickness
in. mm
Nom. Jacket
Thickness
in. mm
Nom. O.D.
in. mm Color Code
882270 70 22 7/30 .030 0.76 .010 0.25 .032 0.81 .610 15.49 3
882280 80 22 7/30 .030 0.76 .010 0.25 .032 0.81 .630 16.00 3
882290 90 22 7/30 .030 0.76 .010 0.25 .040 1.02 .660 16.76 3
882200 100 22 7/30 .030 0.76 .010 0.25 .040 1.02 .710 18.03 3
882002 2 20 10/30 .038 0.97 .016 0.41 .032 0.81 .176 4.47 1
Part Number No. of
Conductors AWG Stranding Nom. Dia. of
Conductor
in. mm
Nom. Insulation
Thickness
in. mm
Nom. Jacket
Thickness
in. mm
Nom. O.D.
in. mm Color Code
882003 3 20 10/30 .038 0.97 .016 0.41 .032 0.81 .212 5.38 1
882004 4 20 10/30 .038 0.97 .016 0.41 .032 0.81 .217 5.51 1
882005 5 20 10/30 .038 0.97 .016 0.41 .032 0.81 .239 6.08 1
882006 6 20 10/30 .038 0.97 .016 0.41 .032 0.81 .242 6.15 1
882007 7 20 10/30 .038 0.97 .016 0.41 .032 0.81 .260 6.60 1
Part Number No. of
Conductors AWG Stranding Nom. Dia. of
Conductor
in. mm
Nom. Insulation
Thickness
in. mm
Nom. Jacket
Thickness
in. mm
Nom. O.D.
in. mm Color Code
882008 8 20 10/30 .038 0.97 .016 0.41 .032 0.81 .285 7.24 1
882009 9 20 10/30 .038 0.97 .016 0.41 .035 0.89 .317 8.05 1
882010 10 20 10/30 .038 0.97 .016 0.41 .035 0.89 .318 8.08 1
882012 12 20 10/30 .038 0.97 .016 0.41 .035 0.89 .338 8.58 1
882015 15 20 10/30 .038 0.97 .016 0.41 .040 1.02 .389 9.88 2
Part Number No. of
Conductors AWG Stranding Nom. Dia. of
Conductor
in. mm
Nom. Insulation
Thickness
in. mm
Nom. Jacket
Thickness
in. mm
Nom. O.D.
in. mm Color Code
882020 20 20 10/30 .038 0.97 .016 0.41 .040 1.02 .430 10.92 1
882025 25 20 10/30 .038 0.97 .016 0.41 .040 1.02 .471 11.96 1
881802 2 18 16/30 .050 1.27 .016 0.41 .032 0.81 .198 5.03 1
881803 3 18 16/30 .050 1.27 .016 0.41 .032 0.81 .242 6.15 2
881804 4 18 16/30 .050 1.27 .016 0.41 .037 0.94 .254 6.45 1
Part Number No. of
Conductors AWG Stranding Nom. Dia. of
Conductor
in. mm
Nom. Insulation
Thickness
in. mm
Nom. Jacket
Thickness
in. mm
Nom. O.D.
in. mm Color Code
881805 5 18 16/30 .050 1.27 .016 0.41 .037 0.94 .286 7.26 1
881806 6 18 16/30 .050 1.27 .016 0.41 .037 0.94 .289 7.34 1
881807 7 18 16/30 .050 1.27 .016 0.41 .037 0.94 .324 8.23 1
881808 8 18 16/30 .050 1.27 .016 0.41 .037 0.94 .341 8.66 1
881809 9 18 16/30 .050 1.27 .016 0.41 .037 0.94 .379 9.63 1
Part Number No. of
Conductors AWG Stranding Nom. Dia. of
Conductor
in. mm
Nom. Insulation
Thickness
in. mm
Nom. Jacket
Thickness
in. mm
Nom. O.D.
in. mm Color Code
881810 10 18 16/30 .050 1.27 .016 0.41 .037 0.94 .385 9.78 1
881812 12 18 16/30 .050 1.27 .016 0.41 .040 1.02 .412 10.46 2
881815 15 18 16/30 .050 1.27 .016 0.41 .045 1.14 .465 11.81 2
881819 19 18 16/30 .050 1.27 .016 0.41 .045 1.14 .505 12.83 2
881820 20 18 16/30 .050 1.27 .016 0.41 .045 1.14 .511 12.98 1
Part Number No. of
Conductors AWG Stranding Nom. Dia. of
Conductor
in. mm
Nom. Insulation
Thickness
in. mm
Nom. Jacket
Thickness
in. mm
Nom. O.D.
in. mm Color Code
881825 25 18 16/30 .050 1.27 .016 0.41 .060 1.52 .600 15.24 2
881602 2 16 26/30 .062 1.57 .016 0.41 .032 0.81 .308 7.82 2
881603 3 16 26/30 .062 1.57 .031 0.79 .032 0.81 .329 8.36 2
881604 4 16 26/30 .062 1.57 .031 0.79 .045 1.14 .375 9.53 2
881605 5 16 26/30 .062 1.57 .031 0.79 .045 1.14 .405 10.29 2
Part Number No. of
Conductors AWG Stranding Nom. Dia. of
Conductor
in. mm
Nom. Insulation
Thickness
in. mm
Nom. Jacket
Thickness
in. mm
Nom. O.D.
in. mm Color Code
881606 6 16 26/30 .062 1.57 .031 0.79 .045 1.14 .410 10.41 1
881607 7 16 26/30 .062 1.57 .031 0.79 .045 1.14 .455 11.56 2
881608 8 16 26/30 .062 1.57 .031 0.79 .045 1.14 .495 12.57 2
881609 9 16 26/30 .062 1.57 .031 0.79 .045 1.14 .500 12.70 2
881610 10 16 26/30 .062 1.57 .031 0.79 .045 1.14 .534 13.56 1
Part Number No. of
Conductors AWG Stranding Nom. Dia. of
Conductor
in. mm
Nom. Insulation
Thickness
in. mm
Nom. Jacket
Thickness
in. mm
Nom. O.D.
in. mm Color Code
881612 12 16 26/30 .062 1.57 .031 0.79 .060 1.52 .610 15.49 2
881615 15 16 26/30 .062 1.57 .031 0.79 .060 1.52 .670 17.02 2
881619 19 16 26/30 .062 1.57 .031 0.79 .065 1.65 .700 17.78 2
881620 20 16 26/30 .062 1.57 .031 0.79 .065 1.65 .757 19.23 1
881625 25 16 26/30 .062 1.57 .031 0.79 .065 1.65 .850 21.59 2
Part Number No. of
Conductors AWG Stranding Nom. Dia. of
Conductor
in. mm
Nom. Insulation
Thickness
in. mm
Nom. Jacket
Thickness
in. mm
Nom. O.D.
in. mm Color Code
881402 2 14 41/30 .080 2.03 .031 0.79 .035 0.89 .354 8.99 2
881403 3 14 41/30 .080 2.03 .031 0.79 .035 0.89 .378 9.60 2
881404 4 14 41/30 .080 2.03 .031 0.79 .045 1.14 .434 11.02 2
881405 5 14 41/30 .080 2.03 .031 0.79 .060 1.52 .485 12.32 2
881407 7 14 41/30 .080 2.03 .031 0.79 .060 1.52 .546 13.87 2
Part Number No. of
Conductors AWG Stranding Nom. Dia. of
Conductor
in. mm
Nom. Insulation
Thickness
in. mm
Nom. Jacket
Thickness
in. mm
Nom. O.D.
in. mm Color Code
881409 9 14 41/30 .080 2.03 .031 0.79 .065 1.65 .620 15.75 2
881412 12 14 41/30 .080 2.03 .031 0.79 .032 0.81 .695 17.65 2
881415 15 14 41/30 .080 2.03 .031 0.79 .032 0.81 .792 20.12 2
881202 2 12 65/30 .096 2.44 .031 0.79 .032 0.81 .396 10.06 2
881203 3 12 65/30 .096 2.44 .031 0.79 .032 0.81 .423 10.74 2
Part Number No. of
Conductors AWG Stranding Nom. Dia. of
Conductor
in. mm
Nom. Insulation
Thickness
in. mm
Nom. Jacket
Thickness
in. mm
Nom. O.D.
in. mm Color Code
881204 4 12 65/30 .096 2.44 .031 0.79 .032 0.81 .472 11.99 2
881207 7 12 65/30 .096 2.44 .031 0.79 .032 0.81 .594 15.09 2
Jacket or insulation color code variations are available upon request.