PROXIMITY SENSORS
139
Series PR
Spar tan Tubular Inductive Proximity Sensors
12mm
Shielding
ORDERING INFORMATION
2-Wire
DC
2-Wire
AC
3-Wire
DC
EXAMPLE Part Number
PRT12-2DC
FEATURE
2-Wire DC With Cable..............................PRT
2-Wire DC With H (Micro) Connector*..PRCT
3-Wire DC With H (Micro) Connector*....PRC
3-Wire DC ..................................................PR
2-Wire AC ..................................................PR
2-Wire AC With H (Micro) Connector* ....PRC
*NOTE:
Cables For Spartan DC Connector Models —
See page 137 of this catalog.
Cables For Spartan AC Connector Models
Are As Follows:
CIA2-2 — Straight, 2 Meter
CLA2-2— 90° Angle, 2 Meter
SIZE AND SHIELDING
12mm Dia., Shielded ..............................12-2
12mm Dia., Unshielded ..........................12-4
18mm Dia., Shielded ..............................18-5
18mm Dia., Unshielded ..........................18-8
30mm Dia., Shielded ............................30-10
30mm Dia., Unshielded ........................30-15
OUTPUT
N.O. ..........................................................DO
N.C. ..........................................................DC
NPN, N.O. ................................................DN
NPN, N.C. ..............................................DN2
PNP, N.O...................................................DP
N.O. ..........................................................AO
N.C. ..........................................................AC
SIZE 12mm
TYPE 3 Wire DC 2 Wire DC 2 Wire AC
S - Shielded
N - Non-Shielded S N S N S N
Maximum Sensing Distance (Sn)mm 2 4 2 4 2 4
Supply Voltage (Residual Ripple <10%,DC Models) 10-30VDC 20-30VDC 90-250VAC
Switching Frequency Hz 800 400 800 400 20
Maximum Output Current mA 200 50 200
Minimum Output Current mA 5
No Load Current at 12VDC mA < 10
Leakage Current mA Max 0.9 Max 2
Voltage Drop (ON State) <1.5VDC <7VDC <10VAC
Outputs NPN-N.O. or N.C. N.O. or N.O. or
PNP-N.O. N.C. N.C.
Termination 2m Cable or H (Micro) Connector