INTEGRATED CIRCUITS DIVISION
www.ixysic.com
2R07
CPC1961
Absolute Maximum Ratings are stress ratings. Stresses in
excess of these ratings can cause permanent damage to
the device. Functional operation of the device at conditions
beyond those indicated in the operational sections of this
data sheet is not implied.
Absolute Maximum Ratings @ 25ºC
Electrical Characteristics @ 25ºC
Parameter Ratings Units
Blocking Voltage 600 VP
Reverse Input Voltage 5 VP
Input Control Current
Peak (10ms)
50 mA
1A
Input Power Dissipation 1150 mW
Total Package Dissipation 2800 mW
Isolation Voltage, Input to Output 3750 Vrms
Operational Temperature -40 to +85 °C
Storage Temperature -40 to +125 °C
1 Derate linearly 1.33 mW / ºC
2 Derate linearly 6.67 mW / ºC
Parameters Conditions Symbol Min Typ Max Units
Output Characteristics
Operating Voltage Range VL- 20 - 260 Vrms
Load Current 1, Continuous VL=120-240Vrms IL0.005 - 250 mArms
Non-repetitive Single Cycle Surge Current t < 10ms ITSM --1A
Off State Leakage Current VL=600V ILEAK --1µA
On-State Voltage Drop IL=250 mArms ---3V
rms
Critical Rate of Rise 2- dV/dt 500 - - V/µs
Holding Current IF=5 mA IH- 300 - µA
Switching Speeds
Turn-on IF=5 mA ton - - 0.5 cycles
Turn-off toff - - 0.5
Zero-Cross Turn-On Voltage
1st half-cycle - - 5 20 V
Subsequent half-cycles - - - 5 V
Operating Frequency 3- 20 - 500 Hz
Load Power Factor for Guaranteed Turn-On 4- PF 0.25 - - -
Input Characteristics
Input Control Current to Activate 5-I
F- 1.2 5 mA
Input Voltage Drop IF=5mA VF0.9 1.2 1.4 V
Input Drop-out Voltage - 0.8 - - V
Reverse Input Current VR=5V IR- - 10 µA
Common Characteristics
Input to Output Capacitance - CI/O -3-pF
1 Maximum continuous load current of a single pole or the sum of the load currents with both poles operating simultaneously.
2 Tested in accordance with EIA/NARM standard RS-443.
3 Zero Cross 1st half-cycle @ <100Hz
4 Snubber circuits may be required at low power factors.
5 For high noise environment use at least 10mA LED current.