Product Data Sheet 1.0 WATT UNREGULATED SIP DC/DC CONVERTER DC/DC CONVERTERS HPR10XX DESCRIPTION The HPR10XX Series uses advanced circuit design and packaging technology to deliver superior reliability and performance. A 170kHz push-pull oscillator is used in the input stage. Beat-frequency oscillation problems are reduced when using the HPR10XX Series with high frequency isolation amplifiers. FEATURES LOW COST SINGLE-IN-LINE PACKAGE (SIP) INTERNAL INPUT AND OUTPUT FILTERING NON-CONDUCTIVE CASE Reduced parts count and high efficiency add to the reliability of the HPR10XX Series. The high efficiency of the HPR10XX Series means less internal power dissipation, as low as 190mW. With reduced heat dissipation the HPR10XX Series can operate at higher temperatures with no degradation. In addition, the high efficiency of the HPR10XX Series means the series is able to offer greater than 13 W/inch3 of output power density. Operation down to no load will not impact the reliability of the series, although a 1mA minimum load is needed to realize published specifications. The HPR10XX Series provides the user low cost without sacrificing reliability. The use of surface mounted devices and advanced manufacturing technologies make it possible to offer premium performance and low cost. HIGH OUTPUT POWER DENSITY: 13 WATTS/INCH3 EXTENDED TEMPERATURE RANGE: -25C TO +65C HIGH EFFICIENCY: TO 72% TYPICAL MECHANICAL FRONT VIEW Notes: All dimensions are in inches (millimeters). RIGHT SIDE VIEW HPR10XX GRID: 0.100 inches (2.54 millimeters) PIN PLACEMENT TOLERANCE: 0.015" PIN CONNECTIONS 1. +VIN BOTTOM VIEW 2. -VIN 4. -VOUT 5. COM* * Common pin not present on 6. +VOUT single output models. Internet: http://www.cdpowerelectronics.com HPR10XX REV C Power Electronics Division, United States Power Electronics Division, Europe 3400 E Britannia Drive, Tucson, Arizona 85706 Phone: 520.295.4100 Fax: 520.770.9369 C&D Technologies (Power Electronics) Ltd. 132 Shannon Industrial Estate, Shannon, Co. Clare, Ireland Tel: +353.61.474.133 Fax:+353.61.474.141 9/98 Page 1 ELECTRICAL SPECIFICATIONS Specifications typical at TA = +25C, nominal input voltage, rated output current unless otherwise specified. NOMINAL INPUT VOLTAGE RATED OUTPUT VOLTAGE RATED OUTPUT CURRENT INPUT CURRENT NO LOAD RATED LOAD (mAp-p) EFFICIENCY (VDC) (VDC) (mA) (mA) HPR1000 HPR1001 HPR1002 HPR1003 HPR1004 5 5 5 5 5 5 12 15 5 12 200 83 67 100 42 33 33 33 33 33 290 290 285 285 285 8 8 8 8 8 68 69 70 70 70 HPR1005 HPR1006 HPR1007 HPR1008 HPR1009 5 12 12 12 12 15 5 12 15 5 34 200 83 67 100 33 18 18 18 18 285 110 107 107 107 8 10 10 10 10 70 70 71 71 71 HPR1010 HPR1011 HPR1012 HPR1013 HPR1014 12 12 15 15 15 12 15 5 12 15 42 34 200 83 67 18 18 15 15 15 107 107 96 94 94 10 10 10 10 10 71 71 70 70 71 HPR1015 HPR1016 HPR1017 HPR1018 HPR1019 15 15 24 24 12 15 5 12 42 34 200 83 15 15 12 12 94 94 60 60 10 10 15 15 71 71 71 71 HPR1020 HPR1021 HPR1022 HPR1023 24 24 24 24 15 5 12 15 67 100 42 34 12 12 12 12 58 58 58 58 15 15 15 15 72 72 72 72 MODEL (mA) REFLECTED RIPPLE CURRENT (%) Note: Other input to output voltages may be available. Please contact factory. COMMON SPECIFICATIONS Specifications typical at TA = +25C, nominal input voltage, rated output current unless otherwise specified. PARAMETER INPUT Voltage Range Voltage Rise Time ISOLATION Rated Voltage Test Voltage Resistance Capacitance Leakage Current OUTPUT Rated Power Voltage Setpoint Accuracy Ripple & Noise Voltage Temperature Coefficent REGULATION Line Regulation Load Regulation (5V out only) Load Regulation (All other Models) GENERAL Switching Frequency Frequency Change Package Weight MTTF per MIL-HDBK-217, Rev. E Ground Benign Fixed Ground Naval Sheltered Airborne Uninhabited Fighter CONDITIONS MIN TYP MAX UNITS 4.5 5 5.5 VDC 10.8 12 13.2 VDC 13.5 15 16.5 VDC 21.6 24 26.4 VDC See Typical Performance Curves & Application Notes: "Capacitive Loading Effects on Start-Up of DC/DC Converters" 60 Hz, 10 Seconds 1000 1000 10 25 2 VISO= 240VAC, 60Hz 100 8.5 1.0 VDC Vpk G pF Arms .01 W % mVp-p mVrms VDC VDC VDC %/Deg C High Line to Low Line Rated Load to 1mA Load Rated Load to 1mA Load 1 10 3 %/%Vin % % Over Line and Load 170 24 2 kHz % g Circuit Stress Method TA = +25C TA = +35C TA = +35C TA = +35C 3.8 1.4 685 211 MHr MHr kHr kHr Rated Load, Nominal VIN BW = DC to 10MHz BW =10Hz to 2MHz 1mA Load, VOUT = 5V 1mA Load, VOUT = 12V 1mA Load, VOUT = 15V TEMPERATURE Specification Storage 5 100 30 7 15 18 -25 -50 +25 +65 +110 C C * For demonstrated MTTF results reference Reliability Report HPR105 Page 2 HPR10XX REV C 9/98 TYPICAL PERFORMANCE CURVES Specifications typical at TA = +25C, nominal input voltage, rated output current unless otherwise specified. VOUT VS LOAD (5Vout Models) VOUT VS LOAD (5Vout Models) 5.7 5.4 5.5 5.2 VOUT VS LOAD (12Vout Models) 12.5 5.3 12.3 Vout Vout Vout 12.4 5.0 12.2 12.1 5.1 4.8 4.9 4.6 12.0 0 80 40 120 160 11.9 0 20 Output Current (mA) 40 60 0 80 Output Current each load (mA) VOUT VS LOAD (12Vout Models) VOUT VS LOAD (15Vout Models) 12.6 40 60 80 VOUT VS LOAD (15Vout Models) 16.5 15.9 12.5 16.0 15.7 12.4 15.5 12.3 15.5 Vout Vout Vout 20 Output Current each load (mA) 15.0 12.2 15.3 14.5 12.1 15.1 14.0 12.0 14.9 0 10 20 30 13.5 0 40 20 40 60 80 Output Current each load (mA) Output Current each load (mA) EFFICIENCY VS LOAD OSCILLATION FREQUENCY VS TEMPERATURE 90 0.2 0 0.4 0.6 0.8 1.0 Output Power each load (Watts) 220 Efficiency (%) Efficiency (%) 75 60 45 30 200 180 160 15 0 20 0 60 40 140 80 -30 100 0 30 60 90 Temperature (C) % of Rated Load (%) SAFE OPERATING AREA LOAD CAPACITANCE vs INPUT RISE TIME (5 Vout models) 600 50 Total Load Capacitance (uF) Total Load Capacitance (uF) 500 400 300 SAFE OPERATING AREA 200 40 30 SAFE OPERATING AREA 20 10 100 0 0 0 5 10 15 20 25 30 35 Rise Time of Input Voltage (mS) 40 45 5 10 15 20 25 30 35 40 45 50 Rise Time of Input Voltage (mS) NOTES: LOAD CAPACITANCE vs INPUT RISE TIME (12 Vout models) 1.) When operated within the SAFE OPERATING AREA as defined by the above curves, the output voltage of HPR10XX devices is guaranteed to be within 95% of its steady-state value within 100 milliseconds after the input voltage has reached 95% of its steadystate value. 80 70 60 50 SAFE OPERATING AREA 40 0 50 90 Total Load Capacitance (uF) LOAD CAPACITANCE vs INPUT RISE TIME (15 Vout models) 60 30 2.) For dual output models, total load capacitance is the sum of the capacitances on the plus and minus outputs. 20 10 0 0 5 10 15 20 25 30 35 40 45 50 Rise Time of Input Voltage (mS) HPR10XX REV C 9/98 Page 3 ORDERING INFORMATION ABSOLUTE MAXIMUM RATINGS HPR 10XX /H Device Family HPR Indicates DC/DC Converter Internal Power Dissipation.....................................................490mW Short Circuit Duration......................................................Momentary Lead Temperature (soldering, 10 seconds max)..................+300C Model Number Selected from Table of Electrical Characteristics Screening Option ENGINEERING NOTES The information provided herein is believed to be reliable; however, C&D TECHNOLOGIES assumes no responsibility for inaccuracies or omissions. C&D TECHNOLOGIES assumes no responsibility for the use of this information, and all use of such information shall be entirely at the user's own risk. Prices and specifications are subject to change without notice. No patent rights or licenses to any of the circuits described herein are implied or granted to any third party. C&D TECHNOLOGIES does not authorize or warrant any C&D TECHNOLOGIES product for use in life support devices/systems or in aircraft control applications. Page 4 HPR10XX REV C 9/98