DCVOLTAGE
SPECIFICATION
MODEL
OUTPUT
RATEDCURRENT
CURRENTRANGE
RATEDPOWER
RIPPLE&NOISE(max.) Note.2
VOLTAGETOLERANCE Note.3
LINEREGULATION
LOADREGULATION
VOLTAGERANGE
SETUP,RISE,HOLDUP TIME
EFFICIENCY(Typ.)
DCCURRENT(Typ.)
OVERLOAD
OVERVOLTAGE
WORKINGTEMP.
WORKINGHUMIDITY
STORAGETEMP.,HUMIDITY
TEMP.COEFFICIENT
VIBRATION
WITHSTANDVOLTAGE
ISOLATIONRESISTANCE
DIMENSION
INPUT
PROTECTION
ENVIRONMENT
SAFETY &
EMC
(Note4)
OTHERS
NOTE
12V
1.25A
0~1.25A
15W
120mVp-p
1.0%
0.3%
0.3%
1.0%
0.2%
0.2%
2.5s,25ms,---12VDC/24VDC/48VDCatfullload
A:9.2~18VDC B C:36~72VDC:18~36VDC
68%
1.9A/12VDC0.9A/24VDC0.45A/48VDC
105~160% ratedoutputpower
Protectiontype:Hiccupmode,recoversautomaticallyafterfaultconditionisremoved
5.75~6.75V
¡
20~90%RHnon-condensing
10~500Hz,2G10min./1cycle,60min.eachalongX, Y,Zaxes
I/P-O/P:2KVACI/P-FG:1KVACO/P-FG:0.5KVAC
I/P-O/P,I/P-FG,O/P-FG:100MOhms/500VDC /25 /70%RH
78*51*28mm(L*W*H)
SD-15C-12
5V
3A
0~3A
15W
100mVp-p
2.0%
0.5%
0.5%
24V
0.625A
0~0.625A
15W
150mVp-p
72% 70%
13.8~16.2V 27.6~32.4V
EMICONDUCTION&RADIATION CompliancetoEN55022(CISPR22)CLASSB
SD-15A-24
SD-15A-12 SD-15B-12 SD-15B-24 SD-15C-24
SD-15C-05
SD-15B-05
SD-15A-05
76% 75% 76% 79% 77% 78%
VOLTAGE ADJ.RANGE
4.75~5.5VDC 10.8~13.2VDC 21.6~26.4VDC
EMSIMMUNITY CompliancetoEN61000-4-2,3,4,6,8;ENV50204,EN55024,lightindustrylevel,criteria A
PACKING 0.18kg,60PCS/11.8kg
Protectiontype:Shutdowno/pvoltage,re-powerontorecover
-10~+60 (Refertooutputloadderatingcurve)
-20~+85 ,10~95%RH
15WSingleOutput DC-DCConverter SD-15 series
2:1 wide input range
Protections:Short circuit/Over load /voltage
Built-in EMI filter, low ripple noise
100% full load burn-in test
Low cost
High reliability
2 years warranty
Features :
FileName:SD-15-SPEC2010-10-18
1. All parameters NOT specially mentioned are measured at normal input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies.
(as available on http://www.meanwell.com)
0.03%/ (0~50 )
http://store.iiic.cc/