May 2005 1 M9999-051305
KS8995MA Micrel, Inc.
KS8995MA
Integrated 5-Port 10/100 Managed Switch
Rev 2.4
General Description
The KS8995MA is a highly integrated Layer 2 managed
switch with optimized bill of materials (BOM) cost for low port
count, cost-sensitive 10/100Mbps switch systems. It also
provides an extensive feature set such as tag/port-based
VLAN, quality of service (QoS) priority, management, MIB
counters, dual MII interfaces and CPU control/data interfaces
to effectively address both current and emerging Fast Ether-
net applications.
The KS8995MA contains five 10/100 transceivers with pat-
ented mixed-signal low-power technology, five media access
control (MAC) units, a high-speed non-blocking switch fabric,
a dedicated address lookup engine, and an on-chip frame
buffer memory.
All PHY units support 10BASE-T and 100BASE-TX.
In addition, two of the PHY units support 100BASE-FX
(ports 4 and 5).
Features
•Integrated switch with five MACs and five Fast Ethernet
transceivers fully compliant to IEEE 802.3u standard
Shared memory based switch fabric with fully non-
blocking configuration
•1.4Gbps high-performance memory bandwidth
10BASE-T, 100BASE-TX, and 100BASE-FX modes
(FX in ports 4 and 5)
Dual MII configuration: MII-Switch (MAC or PHY mode
MII) and MII-P5 (PHY mode MII)
•IEEE 802.1q tag-based VLAN (16 VLANs, full-range
VID) for DMZ port, WAN/LAN separation or inter-VLAN
switch links
VLAN ID tag/untag options, per-port basis
•Programmable rate limiting 0Mbps to 100Mbps, ingress
and egress port, rate options for high and low priority,
per-port basis in 32Kbps increments
•Flow control or drop packet rate limiting (ingress port)
•Integrated MIB counters for fully compliant statistics
gathering, 34 MIB counters per port
Micrel, Inc. • 2180 Fortune Drive • San Jose, CA 95131 • USA • tel + 1 (408) 944-0800 • fax + 1 (408) 474-1000 • http://www.micrel.com
Functional Diagram
1K Look-Up
Engine
Queue
Mgmnt
10/100
MAC 1
Buffer
Mgmnt
Frame
Buffers
FIFO, Flow Control, VLAN Tagging, Priority
10/100
MAC 2
10/100
MAC 3
10/100
MAC 4
10/100
MAC 5
SNI
10/100
T/Tx 1
10/100
T/Tx 2
10/100
T/Tx 3
10/100
T/Tx/Fx 4
10/100
T/Tx/Fx 5
SPI
EEPROM
I/F
LED I/F
Auto
MDI/MDI-X
Control Reg I/F
KS8995MA
MIB
Counters
MII-SW or SNI
LED0[5:1]
LED1[5:1]
LED2[5:1]
Control
Registers
MII-P5
MDC, MDI/O
Auto
MDI/MDI-X
Auto
MDI/MDI-X
Auto
MDI/MDI-X
Auto
MDI/MDI-X
KS8995MA Micrel, Inc.
M9999-051305 2May 2005
Features (continued)
Enable/Disable option for huge frame size up to 1916
bytes per frame
•IGMP v1/v2 snooping for multicast packet filtering
Special tagging mode to send CPU info on ingress
packet’s port value
SPI slave (complete) and MDIO (MII PHY only) serial
management interface for control of register configura-
tion
MAC-id based security lock option
Control registers configurable on-the-fly (port-priority,
802.1p/d/q, AN...)
CPU read access to MAC forwarding table entries
802.1d Spanning Tree Protocol
Port mirroring/monitoring/sniffing: ingress and/or egress
traffic to any port or MII
•Broadcast storm protection with % control global and
per-port basis
Optimization for fiber-to-copper media conversion
Full-chip hardware power-down support (register
configuration not saved)
Per-port based software power-save on PHY (idle link
detection, register configuration preserved)
QoS/CoS packets prioritization supports: per port,
802.1p and DiffServ based
802.1p/q tag insertion or removal on a per-port basis
(egress)
MDC and MDI/O interface support to access the MII
PHY control registers (not all control registers)
•MII local loopback support
On-chip 64Kbyte memory for frame buffering (not
shared with 1K unicast address table)
•Wire-speed reception and transmission
•Integrated look-up engine with dedicated 1K MAC
addresses
Full duplex IEEE 802.3x and half-duplex back pressure
flow control
Comprehensive LED support
•7-wire SNI support for legacy MAC interface
Automatic MDI/MDI-X crossover for plug-and-play
•Disable automatic MDI/MDI-X option
Low power:
Core: 1.8V
I/O: 2.5V or 3.3V
•0.18µm CMOS technology
Commercial temperature range: 0°C to +70°C
•Industrial temperature range: –40°C to +85°C
Available in 128-pin PQFP package
Applications
•Broadband gateway/firewall/VPN
•Integrated DSL or cable modem multi-port router
•Wireless LAN access point plus gateway
Home networking expansion
•Standalone 10/100 switch
Hotel/campus/MxU gateway
Enterprise VoIP gateway/phone
FTTx customer premise equipment
Managed Media converter
Ordering Information
Part Number Temp. Range Package Lead Finish
KS8995MA 0°C to +70°C128-Pin PQFP Standard
KSZ8995MA 0°C to +70°C128-Pin PQFP Lead-Free
KS8995MAI –40°C to +85°C128-Pin PQFP Standard
May 2005 3 M9999-051305
KS8995MA Micrel, Inc.
Revision History
Revision Date Summary of Changes
2.0 10/10/03 Created.
2.1 10/30/03 Editorial changes on electrical characteristics.
2.2 4/1/04 Editorial changes on the TTL input and output electrical characteristics.
2.3 1/19/05 Insert recommended reset circuit., Pg. 70. Editorial, Pg. 36
2.4 4/13/05 Changed VDDIO to 3.3V.
Changed Jitter to 16 ns Max.
KS8995MA Micrel, Inc.
M9999-051305 4May 2005
Table of Contents
System Level Applications ......................................................................................................................................... 7
Pin Description by Number ........................................................................................................................................ 9
Pin Description by Name .......................................................................................................................................... 15
Pin Configuration ...................................................................................................................................................... 21
Introduction ........................................................................................................................................................... 22
Functional Overview: Physical Layer Transceiver ............................................................................................... 22
100BASE-TX Transmit ........................................................................................................................................ 22
100BASE-TX Receive ......................................................................................................................................... 22
PLL Clock Synthesizer......................................................................................................................................... 22
Scrambler/De-scrambler (100BASE-TX only) ..................................................................................................... 22
100BASE-FX Operation....................................................................................................................................... 22
100BASE-FX Signal Detection ............................................................................................................................ 22
100BASE-FX Far End Fault ................................................................................................................................ 23
10BASE-T Transmit ............................................................................................................................................. 23
10BASE-T Receive .............................................................................................................................................. 23
Power Management ............................................................................................................................................. 23
MDI/MDI-X Auto Crossover ................................................................................................................................. 23
Auto-Negotiation .................................................................................................................................................. 23
Functional Overview: Switch Core ......................................................................................................................... 24
Address Look-Up ................................................................................................................................................. 24
Learning ........................................................................................................................................................... 24
Migration ........................................................................................................................................................... 24
Aging ........................................................................................................................................................... 24
Forwarding ........................................................................................................................................................... 24
Switching Engine ................................................................................................................................................. 24
MAC Operation .................................................................................................................................................... 24
Inter-Packet Gap (IPG) ................................................................................................................................ 24
Backoff Algorithm ......................................................................................................................................... 24
Late Collision................................................................................................................................................ 26
Illegal Frames .............................................................................................................................................. 26
Flow Control ................................................................................................................................................. 26
Half-Duplex Back Pressure .......................................................................................................................... 26
Broadcast Storm Protection ......................................................................................................................... 26
MII Interface Operation ........................................................................................................................................ 26
SNI Interface Operation ....................................................................................................................................... 28
Advanced Functionality............................................................................................................................................ 28
Spanning Tree Support ........................................................................................................................................ 28
Special Tagging Mode ......................................................................................................................................... 29
IGMP Support ...................................................................................................................................................... 30
Port Mirroring Support ......................................................................................................................................... 31
VLAN Support ...................................................................................................................................................... 31
Rate Limit Support ............................................................................................................................................... 32
Configuration Interface ........................................................................................................................................ 33
I2C Master Serial Bus Configuration ............................................................................................................ 35
SPI Slave Serial Bus Configuration ............................................................................................................. 35
MII Management Interface (MIIM) ....................................................................................................................... 38
May 2005 5 M9999-051305
KS8995MA Micrel, Inc.
Register Description ................................................................................................................................................. 39
Global Registers .................................................................................................................................................. 39
Register 0 (0x00): Chip ID0 ......................................................................................................................... 39
Register 1 (0x01): Chip ID1/Start Switch ..................................................................................................... 39
Register 2 (0x02): Global Control 0 ............................................................................................................. 40
Register 3 (0x03): Global Control 1 ............................................................................................................. 40
Register 4 (0x04): Global Control 2 ............................................................................................................. 41
Register 5 (0x05): Global Control 3 ............................................................................................................. 42
Register 6 (0x06): Global Control 4 ............................................................................................................. 42
Register 7 (0x07): Global Control 5 ............................................................................................................. 43
Register 8 (0x08): Global Control 6 ............................................................................................................. 43
Register 9 (0x09): Global Control 7 ............................................................................................................. 43
Register 10 (0x0A): Global Control 8 ........................................................................................................... 43
Register 11 (0x0B): Global Control 9 ........................................................................................................... 43
Port Registers ...................................................................................................................................................... 44
Register 16 (0x10): Port 1 Control 0 ........................................................................................................... 44
Register 17 (0x11): Port 1 Control 1 ........................................................................................................... 44
Register 18 (0x12): Port 1 Control 2 ........................................................................................................... 45
Register 19 (0x13): Port 1 Control 3 ........................................................................................................... 46
Register 20 (0x14): Port 1 Control 4 ........................................................................................................... 46
Register 21 (0x15): Port 1 Control 5 ........................................................................................................... 46
Register 22 (0x16): Port 1 Control 6 ........................................................................................................... 46
Register 23 (0x17): Port 1 Control 7 ........................................................................................................... 46
Register 24 (0x18): Port 1 Control 8 ........................................................................................................... 47
Register 25 (0x19): Port 1 Control 9 ........................................................................................................... 47
Register 26 (0x1A): Port 1 Control 10 ......................................................................................................... 47
Register 27 (0x1B): Port 1 Control 11 ......................................................................................................... 47
Register 28 (0x1C): Port 1 Control 12 ......................................................................................................... 48
Register 29 (0x1D): Port 1 Control 13 ......................................................................................................... 49
Register 30 (0x1E): Port 1 Status 0 ............................................................................................................ 49
Register 31 (0x1F): Port 1 Control 14 ......................................................................................................... 50
Advanced Control Registers ................................................................................................................................ 50
Register 96 (0x60): TOS Priority Control Register 0 ................................................................................... 50
Register 97 (0x61): TOS Priority Control Register 1 ................................................................................... 50
Register 98 (0x62): TOS Priority Control Register 2 ................................................................................... 50
Register 99 (0x63): TOS Priority Control Register 3 ................................................................................... 50
Register 100 (0x64): TOS Priority Control Register 4 ................................................................................. 50
Register 101 (0x65): TOS Priority Control Register 5 ................................................................................. 50
Register 102 (0x66): TOS Priority Control Register 6 ................................................................................. 50
Register 103 (0x67): TOS Priority Control Register 7 ................................................................................. 50
Register 104 (0x68): MAC Address Register 0 ........................................................................................... 50
Register 105 (0x69): MAC Address Register 1 ........................................................................................... 50
Register 106 (0x6A): MAC Address Register 2 .......................................................................................... 51
Register 107 (0x6B): MAC Address Register 3 .......................................................................................... 51
Register 108 (0x6C): MAC Address Register 4 .......................................................................................... 51
Register 109 (0X6D): MAC Address Register 5 .......................................................................................... 51
Register 110 (0x6E): Indirect Access Control 0 .......................................................................................... 51
Register 111 (0x6F): Indirect Access Control 1 .......................................................................................... 51
KS8995MA Micrel, Inc.
M9999-051305 6May 2005
Register 112 (0x70): Indirect Data Register 8 ............................................................................................. 51
Register 113 (0x71): Indirect Data Register 7 ............................................................................................. 51
Register 114 (0x72): Indirect Data Register 6 ............................................................................................. 51
Register 115 (0x73): Indirect Data Register 5 ............................................................................................. 51
Register 116 (0x74): Indirect Data Register 4 ............................................................................................. 51
Register 117 (0x75): Indirect Data Register 3 ............................................................................................. 51
Register 118 (0x76): Indirect Data Register 2 ............................................................................................. 51
Register 119 (0x77): Indirect Data Register 1 ............................................................................................. 51
Register 120 (0x78): Indirect Data Register 0 ............................................................................................. 51
Register 121 (0x79): Digital Testing Status 0 ............................................................................................. 52
Register 122 (0x7A): Digital Testing Status 1 ............................................................................................. 52
Register 123 (0x7B): Digital Testing Control 0 ............................................................................................ 52
Register 124 (0x7C): Digital Testing Control 1............................................................................................ 52
Register 125 (0x7D): Analog Testing Control 0 .......................................................................................... 52
Register 126 (0x7E): Analog Testing Control 1 ........................................................................................... 52
Register 127 (0x7F): Analog Testing Status ............................................................................................... 52
Static MAC Address .................................................................................................................................................. 53
VLAN Address ........................................................................................................................................................... 55
Dynamic MAC Address ............................................................................................................................................. 56
MIB Counters ........................................................................................................................................................... 57
MIIM Registers ........................................................................................................................................................... 60
Register 0: MII Control ................................................................................................................................. 60
Register 1: MII Status .................................................................................................................................. 61
Register 2: PHYID HIGH ............................................................................................................................. 61
Register 3: PHYID LOW .............................................................................................................................. 61
Register 4: Advertisement Ability ................................................................................................................. 61
Register 5: Link Partner Ability .................................................................................................................... 62
Absolute Maximum Ratings ..................................................................................................................................... 63
Operating Ratings ..................................................................................................................................................... 63
Electrical Characteristics ......................................................................................................................................... 63
Timing Diagrams ....................................................................................................................................................... 65
Selection of Isolation Transformers........................................................................................................................ 72
Qualified Magnetic Lists ........................................................................................................................................... 72
Package Information ................................................................................................................................................. 73
May 2005 7 M9999-051305
KS8995MA Micrel, Inc.
System Level Applications
Ethernet
MAC
CPU
Switch Controller
On-Chip Frame Buffers
MII-SW
10/100
PHY 5
4-port
LAN
MII-P5
1-port
WAN I/F
10/100
MAC 1
10/100
MAC 2
10/100
MAC 3
10/100
MAC 4
10/100
MAC 5
10/100
PHY 1
10/100
PHY 2
10/100
PHY 3
10/100
PHY 4
SPI/GPIO
SPI
Ethernet
MAC
External WAN port PHY not required.
Figure 1. Broadband Gateway
Ethernet
MAC
CPU
Switch Controller
On-Chip Frame Buffers
MII-SW
10/100
PHY 5
4-port
LAN
MII-P5
10/100
MAC 1
10/100
MAC 2
10/100
MAC 3
10/100
MAC 4
10/100
MAC 5
10/100
PHY 1
10/100
PHY 2
10/100
PHY 3
10/100
PHY 4
WAN PHY & AFE
(xDSL, CM...)
SPISPI/GPIO
Figure 2. Integrated Broadband Router
KS8995MA Micrel, Inc.
M9999-051305 8May 2005
Switch Controller
On-Chip Frame Buffers
10/100
PHY 5
5-port
LAN
10/100
MAC 1
10/100
MAC 2
10/100
MAC 3
10/100
MAC 4
10/100
MAC 5
10/100
PHY 1
10/100
PHY 2
10/100
PHY 3
10/100
PHY 4
Figure 3. Standalone Switch
May 2005 9 M9999-051305
KS8995MA Micrel, Inc.
Pin Description (by Number)
Pin Number Pin Name Type(1) Port Pin Function(2)
1MDI-XDIS Ipd 1-5 Disable auto MDI/MDI-X.
PD (default) = normal operation.
PU = disable auto MDI/MDI-X on all ports.
2GNDA Gnd Analog ground.
3VDDAR P 1.8V analog VDD.
4RXP1 I 1 Physical receive signal + (differential).
5RXM1 I 1 Physical receive signal – (differential).
6GNDA Gnd Analog ground.
7TXP1 O 1 Physical transmit signal + (differential).
8TXM1 O 1 Physical transmit signal – (differential).
9VDDAT P 2.5V or 3.3V analog VDD.
10 RXP2 I 2 Physical receive signal + (differential).
11 RXM2 I 2 Physical receive signal - (differential).
12 GNDA Gnd Analog ground.
13 TXP2 O 2 Physical transmit signal + (differential).
14 TXM2 O 2 Physical transmit signal – (differential).
15 VDDAR P 1.8V analog VDD.
16 GNDA Gnd Analog ground.
17 ISET Set physical transmit output current. Pull-down with a 3.01k 1%
resistor.
18 VDDAT P 2.5V or 3.3V analog VDD.
19 RXP3 I 3 Physical receive signal + (differential).
20 RXM3 I 3 Physical receive signal – (differential).
21 GNDA Gnd Analog ground.
22 TXP3 O 3 Physical transmit signal + (differential).
23 TXM3 O 3 Physical transmit signal – (differential).
24 VDDAT P 2.5V or 3.3V analog VDD.
25 RXP4 I 4 Physical receive signal + (differential).
26 RXM4 I 4 Physical receive signal – (differential).
27 GNDA Gnd Analog ground.
28 TXP4 O 4 Physical transmit signal + (differential).
29 TXM4 O 4 Physical transmit signal – (differential).
30 GNDA Gnd Analog ground.
Note:
1. P = Power supply.
I = Input.
O = Output.
I/O = Bidirectional.
Gnd = Ground.
Ipu = Input w/ internal pull-up.
Ipd = Input w/ internal pull-down.
Ipd/O = Input w/ internal pull-down during reset, output pin otherwise.
Ipu/O = Input w/ internal pull-up during reset, output pin otherwise.
NC = No connect.
2. PU = Strap pin pull-up.
PD = Strap pin pull-down.
KS8995MA Micrel, Inc.
M9999-051305 10 May 2005
Pin Number Pin Name Type(1) Port Pin Function
31 VDDAR P 1.8V analog VDD.
32 RXP5 I 5 Physical receive signal + (differential).
33 RXM5 I 5 Physical receive signal – (differential).
34 GNDA Gnd Analog ground.
35 TXP5 O 5 Physical transmit signal + (differential).
36 TXM5 O 5 Physical transmit signal – (differential).
37 VDDAT P 2.5V or 3.3V analog VDD.
38 FXSD5 I 5 Fiber signal detect/factory test pin.
39 FXSD4 I 4 Fiber signal detect/factory test pin.
40 GNDA Gnd Analog ground.
41 VDDAR P 1.8V analog VDD.
42 GNDA Gnd Analog ground.
43 VDDAR P 1.8V analog VDD.
44 GNDA Gnd Analog ground.
45 MUX1 NC Factory test pins. MUX1 and MUX2 should be left unconnected for
46 MUX2 NC normal operation.
Mode MUX1 MUX2
Normal Operation NC NC
47 PWRDN_N Ipu Full-chip power down. Active low.
48 RESERVE NC Reserved pin. No connect.
49 GNDD Gnd Digital ground.
50 VDDC P 1.8V digital core VDD.
51 PMTXEN Ipd 5 PHY[5] MII transmit enable.
52 PMTXD3 Ipd 5 PHY[5] MII transmit bit 3.
53 PMTXD2 Ipd 5 PHY[5] MII transmit bit 2.
54 PMTXD1 Ipd 5 PHY[5] MII transmit bit 1.
55 PMTXD0 Ipd 5 PHY[5] MII transmit bit 0.
56 PMTXER Ipd 5 PHY[5] MII transmit error.
57 PMTXC O 5 PHY[5] MII transmit clock. PHY mode MII.
58 GNDD Gnd Digital ground.
59 VDDIO P 3.3V digital VDD for digital I/O circuitry.
60 PMRXC O 5 PHY[5] MII receive clock. PHY mode MII.
Note:
1. P = Power supply.
I = Input.
O = Output.
I/O = Bidirectional.
Gnd = Ground.
Ipu = Input w/ internal pull-up.
Ipd = Input w/ internal pull-down.
Ipd/O = Input w/ internal pull-down during reset, output pin otherwise.
Ipu/O = Input w/ internal pull-up during reset, output pin otherwise.
NC = No connect.
May 2005 11 M9999-051305
KS8995MA Micrel, Inc.
Pin Number Pin Name Type(1) Port Pin Function(2)
61 PMRXDV Ipd/O 5 PHY[5] MII receive data valid.
62 PMRXD3 Ipd/O 5 PHY[5] MII receive bit 3. Strap option: PD (default) = enable flow
control; PU = disable flow control.
63 PMRXD2 Ipd/O 5 PHY[5] MII receive bit 2. Strap option: PD (default) = disable back
pressure; PU = enable back pressure.
64 PMRXD1 Ipd/O 5 PHY[5] MII receive bit 1. Strap option: PD (default) = drop excessive
collision packets; PU = does not drop excessive collision packets.
65 PMRXD0 Ipd/O 5 PHY[5] MII receive bit 0. Strap option: PD (default) = disable
aggressive back-off algorithm in half-duplex mode; PU = enable for
performance enhancement.
66 PMRXER Ipd/O 5 PHY[5] MII receive error. Strap option: PD (default) = 1522/1518 bytes;
PU = packet size up to 1536 bytes.
67 PCRS Ipd/O 5 PHY[5] MII carrier sense/force duplex mode. See “Register 76” for
port 4 only. PD (default) = force half-duplex if auto-negotiation is
disabled or fails. PU = force full-duplex if auto-negotiation is disabled
or fails.
68 PCOL Ipd/O 5 PHY[5] MII collision detect/force flow control. See “Register 66” for
port 4 only. PD (default) = no force flow control. normal operation. PU =
force flow control.
69 SMTXEN Ipd Switch MII transmit enable.
70 SMTXD3 Ipd Switch MII transmit bit 3.
71 SMTXD2 Ipd Switch MII transmit bit 2.
72 SMTXD1 Ipd Switch MII transmit bit 1.
73 SMTXD0 Ipd Switch MII transmit bit 0.
74 SMTXER Ipd Switch MII transmit error.
75 SMTXC I/O Switch MII transmit clock. Input in MAC mode, output in PHY mode MII.
76 GNDD Gnd Digital ground.
77 VDDIO P 3.3V digital VDD for digital I/O circuitry
78 SMRXC I/O Switch MII receive clock. Input in MAC mode, output in PHY mode MII.
79 SMRXDV Ipd/O Switch MII receive data valid
80 SMRXD3 Ipd/O Switch MII receive bit 3. Strap option: PD (default) = Disable Switch MII
full-duplex flow control; PU = enable switch MII full-duplex flow control.
81 SMRXD2 Ipd/O Switch MII receive bit 2. Strap option: PD (default) = switch MII in full
duplex mode; PU = switch MII in half-duplex mode.
Note:
1. P = Power supply.
I = Input.
O = Output.
I/O = Bidirectional.
Gnd = Ground.
Ipu = Input w/ internal pull-up.
Ipd = Input w/ internal pull-down.
Ipd/O = Input w/ internal pull-down during reset, output pin otherwise.
Ipu/O = Input w/ internal pull-up during reset, output pin otherwise.
NC = No connect.
2. PU = Strap pin pull-up.
PD = Strap pin pull-down.
KS8995MA Micrel, Inc.
M9999-051305 12 May 2005
Pin Number Pin Name Type(1) Port Pin Function(2)
82 SMRXD1 Ipd/O Switch MII receive bit 1. Strap option: PD (default) = switch MII in
100Mbps mode; PU = switch MII in 10Mbps mode.
83 SMRXD0 Ipd/O Switch MII receive bit 0. Strap option: LED mode
PD (default) = mode 0; PU = mode 1. See “Register 11.”
Mode 0 Mode 1
LEDX_2 Lnk/Act 100Lnk/Act
LEDX_1 Fulld/Col 10Lnk/Act
LEDX_0 Speed Full duplex
84 SCOL Ipd/O Switch MII collision detect.
85 SCRS Ipd/O Switch MII carrier sense.
86 SCONF1 Ipd Dual MII configuration pin.
Pin (91, 86, 87): Switch MII PHY [5] MII
000 Disable, Otri Disable, Otri
001 PHY Mode MII Disable, Otri
010 MAC Mode MII Disable, Otri
011 PHY Mode SNI Disable, Otri
100 Disable Disable
101 PHY Mode MII PHY Mode MII
110 MAC Mode MII PHY Mode MII
111 PHY Mode SNI PHY Mode MII
87 SCONF0 Ipd Dual MII configuration pin.
88 GNDD Gnd Digital ground.
89 VDDC P 1.8V digital core VDD.
90 LED5-2 Ipu/O 5 LED indicator 2. Strap option: aging setup. See “Aging” section.
PU (default) = aging enable; PD = aging disable.
91 LED5-1 Ipu/O 5 LED indicator 1. Strap option: PU (default) = enable PHY MII I/F.
PD: tristate all PHY MII output. See “Pin 86 SCONF1.”
92 LED5-0 Ipu/O 5 LED indicator 0
93 LED4-2 Ipu/O 4 LED indicator 2
94 LED4-1 Ipu/O 4 LED indicator 1
95 LED4-0 Ipu/O 4 LED indicator 0
96 LED3-2 Ipu/O 3 LED indicator 2
97 LED3-1 Ipu/O 3 LED indicator 1
Note:
1. P = Power supply.
I = Input.
O = Output.
I/O = Bidirectional.
Gnd = Ground.
Ipu = Input w/ internal pull-up.
Ipd = Input w/ internal pull-down.
Ipd/O = Input w/ internal pull-down during reset, output pin otherwise.
Ipu/O = Input w/ internal pull-up during reset, output pin otherwise.
NC = No connect.
2. PU = Strap pin pull-up. Otri = Output tristated.
PD = Strap pin pull-down. Fulld = Full duplex.
May 2005 13 M9999-051305
KS8995MA Micrel, Inc.
Pin Number Pin Name Type(1) Port Pin Function
98 LED3-0 Ipu/O 3 LED indicator 0.
99 GNDD Gnd Digital ground.
100 VDDIO P 3.3V digital VDD for digital I/O.
101 LED2-2 Ipu/O 2 LED indicator 2.
102 LED2-1 Ipu/O 2 LED indicator 1.
103 LED2-0 Ipu/O 2 LED indicator 0.
104 LED1-2 Ipu/O 1 LED indicator 2.
105 LED1-1 Ipu/O 1 LED indicator 1.
106 LED1-0 Ipu/O 1 LED indicator 0.
107 MDC Ipu All Switch or PHY[5] MII management data clock.
108 MDIO I/O All Switch or PHY[5] MII management data I/O.
Features internal pull down to define pin state when not driven.
109 SPIQ Otri All (1) SPI serial data output in SPI slave mode; (2) not used in I2C master
mode. See “Pin 113.”
110 SPIC/SCL I/O All (1) Input clock up to 5MHz in SPI slave mode; (2) output clock at
81kHz in I2C master mode. See “Pin 113.”
111 SPID/SDA I/O All (1) Serial data input in SPI slave mode; (2) serial data input/output in
I2C master mode. See “Pin 113.”
112 SPIS_N Ipu All Active low. (1) SPI data transfer start in SPI slave mode. When SPIS_N
is high, the KS8995MA is deselected and SPIQ is held in high
impedance state, a high-to-low transition to initiate the SPI data transfer;
(2) not used in I2C master mode.
113 PS1 Ipd Serial bus configuration pin.
For this case, if the EEPROM is not present, the KS8995MA will start
itself with the PS[1:0] = 00 default register values .
Pin Configuration Serial Bus Configuration
PS[1:0]=00 I2C Master Mode for EEPROM
PS[1:0]=01 Reserved
PS[1:0]=10 SPI Slave Mode for CPU Interface
PS[1:0]=11 Factory Test Mode (BIST)
114 PS0 Ipd Serial bus configuration pin. See “Pin 113.”
115 RST_N Ipu Reset the KS8995MA. Active low.
116 GNDD Gnd Digital ground.
117 VDDC P 1.8V digital core VDD.
118 TESTEN Ipd NC for normal operation. Factory test pin.
Note:
1. P = Power supply.
I = Input.
O = Output.
I/O = Bidirectional.
Gnd = Ground.
Ipu = Input w/ internal pull-up.
Ipd = Input w/ internal pull-down.
Ipd/O = Input w/ internal pull-down during reset, output pin otherwise.
Ipu/O = Input w/ internal pull-up during reset, output pin otherwise.
NC = No connect.
KS8995MA Micrel, Inc.
M9999-051305 14 May 2005
Pin Number Pin Name Type(1) Port Pin Function
119 SCANEN Ipd NC for normal operation. Factory test pin.
120 NC NC No connect.
121 X1 I 25MHz crystal clock connection/or 3.3V tolerant oscillator input.
Oscillator should be ±100ppm.
122 X2 O 25MHz crystal clock connection.
123 VDDAP P 1.8V analog VDD for PLL.
124 GNDA Gnd Analog ground.
125 VDDAR P 1.8V analog VDD.
126 GNDA Gnd Analog ground.
127 GNDA Gnd Analog ground.
128 TEST2 NC NC for normal operation. Factory test pin.
Note:
1. P = Power supply.
I = Input.
O = Output.
I/O = Bidirectional.
Gnd = Ground.
Ipu = Input w/ internal pull-up.
Ipd = Input w/ internal pull-down.
Ipd/O = Input w/ internal pull-down during reset, output pin otherwise.
Ipu/O = Input w/ internal pull-up during reset, output pin otherwise.
NC = No connect.
May 2005 15 M9999-051305
KS8995MA Micrel, Inc.
Pin Description (by Name)
Pin Number Pin Name Type(1) Port Pin Function
39 FXSD4 I 4 Fiber signal detect/factory test pin.
38 FXSD5 I 5 Fiber signal detect/factory test pin.
124 GNDA Gnd Analog ground.
42 GNDA Gnd Analog ground.
44 GNDA Gnd Analog ground.
2GNDA Gnd Analog ground.
16 GNDA Gnd Analog ground.
30 GNDA Gnd Analog ground.
6GNDA Gnd Analog ground.
12 GNDA Gnd Analog ground.
21 GNDA Gnd Analog ground.
27 GNDA Gnd Analog ground.
34 GNDA Gnd Analog ground.
40 GNDA Gnd Analog ground.
120 NC NC No connect.
127 GNDA Gnd Analog ground.
126 GNDA Gnd Analog ground.
49 GNDD Gnd Digital ground.
88 GNDD Gnd Digital ground.
116 GNDD Gnd Digital ground.
58 GNDD Gnd Digital ground.
76 GNDD Gnd Digital ground.
99 GNDD Gnd Digital ground.
17 ISET Set physical transmit output current. Pull-down with a 3.01k 1%
resistor.
106 LED1-0 Ipu/O 1 LED indicator 0.
105 LED1-1 Ipu/O 1 LED indicator 1.
104 LED1-2 Ipu/O 1 LED indicator 2.
103 LED2-0 Ipu/O 2 LED indicator 0.
102 LED2-1 Ipu/O 2 LED indicator 1.
101 LED2-2 Ipu/O 2 LED indicator 2.
98 LED3-0 Ipu/O 3 LED indicator 0.
Note:
1. P = Power supply.
I = Input.
O = Output.
I/O = Bidirectional.
Gnd = Ground.
Ipu = Input w/ internal pull-up.
Ipd = Input w/ internal pull-down.
Ipd/O = Input w/ internal pull-down during reset, output pin otherwise.
Ipu/O = Input w/ internal pull-up during reset, output pin otherwise.
NC = No connect.
KS8995MA Micrel, Inc.
M9999-051305 16 May 2005
Pin Number Pin Name Type(1) Port Pin Function(2)
97 LED3-1 Ipu/O 3 LED indicator 1.
96 LED3-2 Ipu/O 3 LED indicator 2.
95 LED4-0 Ipu/O 4 LED indicator 0.
94 LED4-1 Ipu/O 4 LED indicator 1.
93 LED4-2 Ipu/O 4 LED indicator 2.
92 LED5-0 Ipu/O 5 LED indicator 0.
91 LED5-1 Ipu/O 5 LED indicator 1. Strap option: PU (default) = enable PHY MII I/F
PD: tristate all PHY MII output. See “Pin 86 SCONF1.”
90 LED5-2 Ipu/O 5 LED indicator 2. Strap option: aging setup. See “Aging” section.
(default) = aging enable; PD = aging disable.
107 MDC Ipu All Switch or PHY[5] MII management data clock.
108 MDIO I/O All Switch or PHY[5] MII management data I/O.
1MDI-XDIS Ipd 1-5 Disable auto MDI/MDI-X.
45 MUX1 NC Factory test pins. MUX1 and MUX2 should be left unconnected for
46 MUX2 NC normal operation.
Mode MUX1 MUX2
Normal Operation NC NC
68 PCOL Ipd/O 5 PHY[5] MII collision detect/force flow control. See “Register 18.”
For port 4 only. PD (default) = no force flow control. PU = force flow
control.
67 PCRS Ipd/O 5 PHY[5] MII carrier sense/force duplex mode. See “Register 28.”
For port 4 only. PD (default) = force half-duplex if auto-negotiation is
disabled or fails. PU = force full-duplex if auto-negotiation is disabled
or fails.
60 PMRXC O 5 PHY[5] MII receive clock. PHY mode MII.
65 PMRXD0 Ipd/O 5 PHY[5] MII receive bit 0. Strap option: PD (default) = disable
aggressive back-off algorithm in half-duplex mode; PU = enable for
performance enhancement.
64 PMRXD1 Ipd/O 5 PHY[5] MII receive bit 1. Strap option: PD (default) = drop excessive
collision packets; PU = does not drop excessive collision packets.
63 PMRXD2 Ipd/O 5 PHY[5] MII receive bit 2. Strap option: PD (default) = disable back
pressure; PU = enable back pressure.
62 PMRXD3 Ipd/O 5 PHY[5] MII receive bit 3. Strap option: PD (default) = enable flow
control; PU = disable flow control.
61 PMRXDV Ipd/O 5 PHY[5] MII receive data valid.
66 PMRXER Ipd/O 5 PHY[5] MII receive error. Strap option: PD (default) = 1522/1518 bytes;
PU = packet size up to 1536 bytes.
Note:
1. P = Power supply.
I = Input.
O = Output.
I/O = Bidirectional.
Gnd = Ground.
Ipu = Input w/ internal pull-up.
Ipd = Input w/ internal pull-down.
Ipd/O = Input w/ internal pull-down during reset, output pin otherwise.
Ipu/O = Input w/ internal pull-up during reset, output pin otherwise.
NC = No connect.
2. PU = Strap pin pull-up.
PD = Strap pin pull-down.
May 2005 17 M9999-051305
KS8995MA Micrel, Inc.
Pin Number Pin Name Type(1) Port Pin Function
57 PMTXC O 5 PHY[5] MII transmit clock. PHY mode MII.
55 PMTXD0 Ipd 5 PHY[5] MII transmit bit 0.
54 PMTXD1 Ipd 5 PHY[5] MII transmit bit 1.
53 PMTXD2 Ipd 5 PHY[5] MII transmit bit 2.
52 PMTXD3 Ipd 5 PHY[5] MII transmit bit 3.
51 PMTXEN Ipd 5 PHY[5] MII transmit enable.
56 PMTXER Ipd 5 PHY[5] MII transmit error.
114 PS0 Ipd Serial bus configuration pin. See “Pin 113.”
113 PS1 Ipd Serial bus configuration pin.
If EEPROM is not present, the KS8995MA will start itself with chip
default (00)...
Pin Configuration Serial Bus Configuration
PS[1:0]=00 I2C Master Mode for EEPROM
PS[1:0]=01 Reserved
PS[1:0]=10 SPI Slave Mode for CPU Interface
PS[1:0]=11 Factory Test Mode (BIST)
47 PWRDN_N Ipu Full-chip power down. Active low.
48 RESERVE NC Reserved pin. No connect.
115 RST_N Ipu Reset the KS8995MA. Active low.
5RXM1 I 1 Physical receive signal – (differential).
11 RXM2 I 2 Physical receive signal – (differential).
20 RXM3 I 3 Physical receive signal – (differential).
26 RXM4 I 4 Physical receive signal – (differential).
33 RXM5 I 5 Physical receive signal – (differential).
4RXP1 I 1 Physical receive signal + (differential).
10 RXP2 I 2 Physical receive signal + (differential).
19 RXP3 I 3 Physical receive signal + (differential).
25 RXP4 I 4 Physical receive signal + (differential).
32 RXP5 I 5 Physical receive signal + (differential).
119 SCANEN Ipd NC for normal operation. Factory test pin.
84 SCOL Ipd/O Switch MII collision detect.
87 SCONF0 Ipd Dual MII configuration pin.
Note:
1. P = Power supply.
I = Input.
O = Output.
I/O = Bidirectional.
Gnd = Ground.
Ipu = Input w/ internal pull-up.
Ipd = Input w/ internal pull-down.
Ipd/O = Input w/ internal pull-down during reset, output pin otherwise.
Ipu/O = Input w/ internal pull-up during reset, output pin otherwise.
NC = No connect.
KS8995MA Micrel, Inc.
M9999-051305 18 May 2005
Pin Number Pin Name Type(1) Port Pin Function(2)
86 SCONF1 Ipd Dual MII configuration pin.
Pin (91, 86, 87): Switch MII PHY [5] MII
000 Disable, Otri Disable, Otri
001 PHY Mode MII Disable, Otri
010 MAC Mode MII Disable, Otri
011 PHY Mode SNI Disable, Otri
100 Disable Disable
101 PHY Mode MII PHY Mode MII
110 MAC Mode MII PHY Mode MII
111 PHY Mode SNI PHY Mode MII
85 SCRS Ipd/O Switch MII carrier sense.
78 SMRXC I/O Switch MII receive clock. Input in MAC mode, output in PHY mode MII.
83 SMRXD0 Ipd/O Switch MII receive bit 0; strap option: LED mode
PD (default) = mode 0; PU = mode 1. See “Register 11.”
Mode 0 Mode 1
LEDX_2 Lnk/Act 100Lnk/Act
LEDX_1 Fulld/Col 10Lnk/Act
LEDX_0 Speed Full duplex
82 SMRXD1 Ipd/O Switch MII receive bit 1. Strap option: PD (default) = switch MII in
100Mbps mode; PU = switch MII in 10Mbps mode.
81 SMRXD2 Ipd/O Switch MII receive bit 2. Strap option: PD (default) = switch MII in
full-duplex mode; PU = switch MII in half-duplex mode.
80 SMRXD3 Ipd/O Switch MII receive bit 3. Strap option: PD (default) = disable switch
MII full-duplex flow control; PU = enable switch MII full-duplex flow control.
79 SMRXDV Ipd/O Switch MII receive data valid.
75 SMTXC I/O Switch MII transmit clock. Input in MAC mode, output in PHY mode MII.
73 SMTXD0 Ipd Switch MII transmit bit 0.
72 SMTXD1 Ipd Switch MII transmit bit 1.
71 SMTXD2 Ipd Switch MII transmit bit 2.
70 SMTXD3 Ipd Switch MII transmit bit 3.
69 SMTXEN Ipd Switch MII transmit enable.
74 SMTXER Ipd Switch MII transmit error.
Note:
1. P = Power supply.
I = Input.
O = Output.
I/O = Bidirectional.
Gnd = Ground.
Ipu = Input w/ internal pull-up.
Ipd = Input w/ internal pull-down.
Ipd/O = Input w/ internal pull-down during reset, output pin otherwise.
Ipu/O = Input w/ internal pull-up during reset, output pin otherwise.
Otri = Output tristated.
NC = No connect.
2. PU = Strap pin pull-up.
PD = Strap pin pull-down.
Fulld = Full duplex.
May 2005 19 M9999-051305
KS8995MA Micrel, Inc.
Pin Number Pin Name Type(1) Port Pin Function
110 SPIC/SCL I/O All (1) Input clock up to 5MHz in SPI slave mode; (2) Output clock at 81kHz
in I2C master mode. See “Pin 113.”
111 SPID/SDA I/O All (1) Serial data input in SPI slave mode; (2) Serial data input/output in
I2C master mode. See “Pin 113.”
109 SPIQ Otri All (1) SPI serial data output in SPI slave mode; (2) Not used in I2C master
mode. See “Pin 113.”
112 SPIS_N Ipu All Active low. (1) SPI data transfer start in SPI slave mode. When SPIS_N
is high, the KS8995MA is deselected and SPIQ is held in high
impedance state, a high-to-low transition to initiate the SPI data
transfer; (2) Not used in I2C master mode.
128 TEST2 NC No connect for normal operation. Factory test pin.
118 TESTEN Ipd No connect for normal operation. Factory test pin.
8TXM1 O 1 Physical transmit signal – (differential).
14 TXM2 O 2 Physical transmit signal – (differential).
23 TXM3 O 3 Physical transmit signal – (differential).
29 TXM4 O 4 Physical transmit signal – (differential).
36 TXM5 O 5 Physical transmit signal – (differential).
7TXP1 O 1 Physical transmit signal + (differential).
13 TXP2 O 2 Physical transmit signal + (differential).
22 TXP3 O 3 Physical transmit signal + (differential).
28 TXP4 O 4 Physical transmit signal + (differential).
35 TXP5 O 5 Physical transmit signal + (differential).
123 VDDAP P 1.8V analog VDD for PLL.
41 VDDAR P 1.8V analog VDD.
43 VDDAR P 1.8V analog VDD.
3VDDAR P 1.8V analog VDD.
15 VDDAR P 1.8V analog VDD.
31 VDDAR P 1.8V analog VDD.
125 VDDAR P 1.8V analog VDD.
18 VDDAT P 2.5V or 3.3V analog VDD.
9VDDAT P 2.5V or 3.3V analog VDD.
24 VDDAT P 2.5V or 3.3V analog VDD.
37 VDDAT P 2.5V or 3.3V analog VDD.
50 VDDC P 1.8V digital core VDD.
Note:
1. P = Power supply.
I = Input.
O = Output.
I/O = Bidirectional.
Gnd = Ground.
Ipu = Input w/ internal pull-up.
Ipd = Input w/ internal pull-down.
Ipd/O = Input w/ internal pull-down during reset, output pin otherwise.
Ipu/O = Input w/ internal pull-up during reset, output pin otherwise.
Otri = Output tristated.
NC = No connect.
KS8995MA Micrel, Inc.
M9999-051305 20 May 2005
Pin Number Pin Name Type(1) Port Pin Function
89 VDDC P 1.8V digital core VDD.
117 VDDC P 1.8V digital core VDD.
59 VDDIO P 3.3V digital VDD for digital I/O circuitry.
77 VDDIO P 3.3V digital VDD for digital I/O circuitry.
100 VDDIO P 3.3V digital VDD for digital I/O circuitry.
121 X1 I 25MHz crystal clock connection/or 3.3V tolerant oscillator input.
Oscillator should be ±100ppm.
122 X2 O 25MHz crystal clock connection.
Note:
1. P = Power supply.
I = Input.
O = Output.
May 2005 21 M9999-051305
KS8995MA Micrel, Inc.
Pin Configuration
MDIXDIS
GNDA
VDDAR
RXP1
RXM1
GNDA
TXP1
TXM1
VDDAT
RXP2
RXM2
GNDA
TXP2
TXM2
VDDAR
GNDA
ISET
VDDAT
RXP3
RXM3
GNDA
TXP3
TXM3
VDDAT
RXP4
RXM4
GNDA
TXP4
TXM4
GNDA
VDDAR
RXP5
RXM5
GNDA
TXP5
TXM5
VDDAT
FXSD5
LED2-1
LED2-2
VDDIO
GNDD
LED3-0
LED3-1
LED3-2
LED4-0
LED4-1
LED4-2
LED5-0
LED5-1
LED5-2
VDDC
GNDD
SCONF0
SCONF1
SCRS
SCOL
SMRXD0
SMRXD1
SMRXD2
SMRXD3
SMRXDV
SMRXC
VDDIO
GNDD
SMTXC
SMTXER
SMTXD0
SMTXD1
SMTXD2
SMTXD3
SMTEXN
PCOL
PCRS
PMRXER
PMRXD0
PMRXD1
PMRXD2
PMRXD3
PMRXDV
PMRXC
VDDIO
GNDD
PMTXC
PMTXER
PMTXD0
PMTXD1
PMTXD2
PMTXD3
PMTXEN
VDDC
GNDD
RESERVE
PWRDN_N
MUX2
MUX1
GNDA
VDDAR
GNDA
VDDAR
GNDA
FXSD4
LED2-0
LED1-2
LED1-1
LED1-0
MDC
MDIO
SPIQ
SPIC/SCL
SPID/SDA
SPIS_N
PS1
PS0
RST_N
GNDD
VDDC
TESTEN
SCANEN
NC
X1
X2
VDDAP
GNDA
VDDAR
GNDA
GNDA
TEST2
65
39
1
103
128-Pin PQFP (PQ)
KS8995MA Micrel, Inc.
M9999-051305 22 May 2005
Introduction
The KS8995MA contains five 10/100 physical layer transceivers and five media access control (MAC) units with an integrated
Layer 2 managed switch. The device runs in three modes. The first mode is as a five-port integrated switch. The second is
as a five-port switch with the fifth port decoupled from the physical port. In this mode, access to the fifth MAC is provided through
a media independent interface (MII) . This is useful for implementing an integrated broadband router. The third mode uses the
dual MII feature to recover the use of the fifth PHY. This allows the additional broadband gateway configuration, where the fifth
PHY may be accessed through the MII-P5 port.
The KS8995MA has the flexibility to reside in a managed or unmanaged design. In a managed design, a host processor has
complete control of the KS8995MA via the SPI bus, or partial control via the MDC/MDIO interface. An unmanaged design is
achieved through I/O strapping or EEPROM programming at system reset time.
On the media side, the KS8995MA supports IEEE 802.3 10BASE-T, 100BASE-TX on all ports, and 100BASE-FX on ports 4
and 5. The KS8995MA can be used as two separate media converters.
Physical signal transmission and reception are enhanced through the use of patented analog circuitry that makes the design
more efficient and allows for lower power consumption and smaller chip die size.
The major enhancements from the KS8995E to the KS8995MA are support for host processor management, a dual MII
interface, tag as well as port based VLAN, spanning tree protocol support, IGMP snooping support, port mirroring support and
rate limiting functionality.
Functional Overview: Physical Layer Transceiver
100BASE-TX Transmit
The 100BASE-TX transmit function performs parallel-to-serial conversion, 4B/5B coding, scrambling, NRZ-to-NRZI conver-
sion, MLT3 encoding and transmission. The circuit starts with a parallel-to-serial conversion, which converts the MII data from
the MAC into a 125MHz serial bit stream. The data and control stream is then converted into 4B/5B coding followed by a
scrambler. The serialized data is further converted from NRZ-to-NRZI format, and then transmitted in MLT3 current output.
The output current is set by an external 1% 3.01k resistor for the 1:1 transformer ratio. It has a typical rise/fall time of 4ns
and complies with the ANSI TP-PMD standard regarding amplitude balance, overshoot, and timing jitter. The wave-shaped
10BASE-T output is also incorporated into the 100BASE-TX transmitter.
100BASE-TX Receive
The 100BASE-TX receiver function performs adaptive equalization, DC restoration, MLT3-to-NRZI conversion, data and clock
recovery, NRZI-to-NRZ conversion, de-scrambling, 4B/5B decoding, and serial-to-parallel conversion. The receiving side
starts with the equalization filter to compensate for inter-symbol interference (ISI) over the twisted pair cable. Since the
amplitude loss and phase distortion is a function of the length of the cable, the equalizer has to adjust its characteristics to
optimize the performance. In this design, the variable equalizer will make an initial estimation based on comparisons of
incoming signal strength against some known cable characteristics, then tunes itself for optimization. This is an ongoing
process and can self-adjust against environmental changes such as temperature variations.
The equalized signal then goes through a DC restoration and data conversion block. The DC restoration circuit is used to
compensate for the effect of baseline wander and improve the dynamic range. The differential data conversion circuit converts
the MLT3 format back to NRZI. The slicing threshold is also adaptive.
The clock recovery circuit extracts the 125MHz clock from the edges of the NRZI signal. This recovered clock is then used to
convert the NRZI signal into the NRZ format. The signal is then sent through the de-scrambler followed by the 4B/5B decoder.
Finally, the NRZ serial data is converted to the MII format and provided as the input data to the MAC.
PLL Clock Synthesizer
The KS8995MA generates 125MHz, 42MHz, 25MHz, and 10MHz clocks for system timing. Internal clocks are generated from
an external 25MHz crystal or oscillator.
Scrambler/De-scrambler (100BASE-TX only)
The purpose of the scrambler is to spread the power spectrum of the signal in order to reduce EMI and baseline wander. The
data is scrambled through the use of an 11-bit wide linear feedback shift register (LFSR). This can generate a 2047-bit non-
repetitive sequence. The receiver will then de-scramble the incoming data stream with the same sequence at the transmitter.
100BASE-FX Operation
100BASE-FX operation is very similar to 100BASE-TX operation except that the scrambler/de-scrambler and MLT3 encoder/
decoder are bypassed on transmission and reception. In this mode the auto-negotiation feature is bypassed since there is no
standard that supports fiber auto-negotiation.
100BASE-FX Signal Detection
The physical port runs in 100BASE-FX mode if FXSDx >0.6V for ports 4 and 5 only. This signal is internally referenced to 1.25V.
The fiber module interface should be set by a voltage divider such that FXSDx ‘H’ is above this 1.25V reference, indicating signal
May 2005 23 M9999-051305
KS8995MA Micrel, Inc.
detect, and FXSDx ‘L’ is below the 1.25V reference to indicate no signal. When FXSDx is below 0.6V then 100BASE-FX mode
is disabled. Since there is no auto-negotiation for 100BASE-FX mode, ports 4 and 5 must be forced to either full or half-duplex.
Note that strap-in options exist to set duplex mode for port 4, but not for port 5.
100BASE-FX Far End Fault
Far end fault occurs when the signal detection is logically false from the receive fiber module. When this occurs, the
transmission side signals the other end of the link by sending 84 1s followed by a zero in the idle period between frames. The
far end fault may be disabled through register settings.
10BASE-T Transmit
The output 10BASE-T driver is incorporated into the 100BASE-T driver to allow transmission with the same magnetics. They
are internally wave-shaped and pre-emphasized into outputs with a typical 2.3V amplitude. The harmonic contents are at least
27dB below the fundamental when driven by an all-ones Manchester-encoded signal.
10BASE-T Receive
On the receive side, input buffer and level detecting squelch circuits are employed. A differential input receiver circuit and a
PLL perform the decoding function. The Manchester-encoded data stream is separated into clock signal and NRZ data. A
squelch circuit rejects signals with levels less than 400mV or with short pulsewidths in order to prevent noises at the RXP or
RXM input from falsely triggering the decoder. When the input exceeds the squelch limit, the PLL locks onto the incoming signal
and the KS8995MA decodes a data frame. The receiver clock is maintained active during idle periods in between data
reception.
Power Management
The KS8995MA features a per port power down mode. To save power the user can power down ports that are not in use by
setting port control registers or MII control registers. In addition, it also supports full chip power down mode. When activated,
the entire chip will be shutdown.
MDI/MDI-X Auto Crossover
The KS8995MA supports MDI/MDI-X auto crossover. This facilitates the use of either a straight connection CAT-5 cable or
a crossover CAT-5 cable. The auto-sense function will detect remote transmit and receive pairs, and correctly assign the
transmit and receive pairs from the Micrel device. This can be highly useful when end users are unaware of cable types and
can also save on an additional uplink configuration connection. The auto crossover feature may be disabled through the port
control registers.
Auto-Negotiation
The KS8995MA conforms to the auto-negotiation protocol as described by the 802.3 committee. Auto-negotiation allows
unshielded twisted pair (UTP) link partners to select the best common mode of operation. In auto-negotiation the link partners
advertise capabilities across the link to each other. If auto-negotiation is not supported or the link partner to the KS8995MA
is forced to bypass auto-negotiation, then the mode is set by observing the signal at the receiver. This is known as parallel mode
because while the transmitter is sending auto-negotiation advertisements, the receiver is listening for advertisements or a fixed
signal protocol.
The flow for the link setup is shown in Figure 4.
Start
Auto Negotiation
Force Link Setting
Listen for 10BASE-T
Link Pulses
Listen for
100BASE-TX Idles
Attempt
Auto-Negotiation
Link Mode Set
Bypass
Auto-Negotiation
and Set Link Mode
Link Mode Set ?
Parallel
Operation
Join Flow
No
Ye s
Ye s
No
Figure 4. Auto-Negotiation
KS8995MA Micrel, Inc.
M9999-051305 24 May 2005
Functional Overview: Switch Core
Address Look-Up
The internal look-up table stores MAC addresses and their associated information. It contains a 1K unicast address table plus
switching information. The KS8995MA is guaranteed to learn 1K addresses and distinguishes itself from a hash-based look-
up table, which depending on the operating environment and probabilities, may not guarantee the absolute number of
addresses it can learn.
Learning
The internal look-up engine updates its table with a new entry if the following conditions are met:
The received packet’s source address (SA) does not exist in the look-up table.
The received packet is good; the packet has no receiving errors and is of legal length.
The look-up engine inserts the qualified SA into the table, along with the port number and time stamp. If the table is full, the
last entry of the table is deleted first to make room for the new entry.
Migration
The internal look-up engine also monitors whether a station is moved. If this occurs, it updates the table accordingly. Migration
happens when the following conditions are met:
The received packet’s SA is in the table but the associated source port information is different.
The received packet is good; the packet has no receiving errors and is of legal length.
The look-up engine will update the existing record in the table with the new source port information.
Aging
The look-up engine will update the time stamp information of a record whenever the corresponding SA appears. The time stamp
is used in the aging process. If a record is not updated for a period of time, the look-up engine will remove the record from the
table. The look-up engine constantly performs the aging process and will continuously remove aging records. The aging period
is 300 + 75 seconds. This feature can be enabled or disabled through Register 3 or by external pull-up or pull-down resistors
on LED[5][2]. See “Register 3” section.
Forwarding
The KS8995MA will forward packets using an algorithm that is depicted in the following flowcharts. Figure 5 shows stage one
of the forwarding algorithm where the search engine looks up the VLAN ID, static table, and dynamic table for the destination
address, and comes up with “port to forward 1” (PTF1). PTF1 is then further modified by the spanning tree, IGMP snooping,
port mirroring, and port VLAN processes to come up with “port to forward 2” (PTF2), as shown in Figure 6. This is where the
packet will be sent.
KS8995MA will not forward the following packets:
•Error packets. These include framing errors, FCS errors, alignment errors, and illegal size packet errors.
802.3x pause frames. The KS8995MA will intercept these packets and perform the appropriate actions.
•“Local” packets. Based on destination address (DA) look-up. If the destination port from the look-up table matches
the port where the packet was from, the packet is defined as “local”.
Switching Engine
The KS8995MA features a high-performance switching engine to move data to and from the MAC’s, packet buffers. It operates
in store and forward mode, while the efficient switching mechanism reduces overall latency.
The KS8995MA has a 64kB internal frame buffer. This resource is shared between all five ports. The buffer sharing mode can
be programmed through Register 2. See “Register 2.” In one mode, ports are allowed to use any free buffers in the buffer pool.
In the second mode, each port is only allowed to use 1/5 of the total buffer pool. There are a total of 512 buffers available. Each
buffer is sized at 128B.
Media Access Controller (MAC) Operation
The KS8995MA strictly abides by IEEE 802.3 standards to maximize compatibility.
Inter Packet Gap (IPG)
If a frame is successfully transmitted, the 96-bit time IPG is measured between the two consecutive MTXEN. If the current
packet is experiencing collision, the 96-bit time IPG is measured from MCRS and the next MTXEN.
Backoff Algorithm
The KS8995MA implements the IEEE Std 802.3 binary exponential back-off algorithm, and optional “aggressive mode” back
off. After 16 collisions, the packet will be optionally dropped depending on the chip configuration in Register 3. See “Register
3.”
May 2005 25 M9999-051305
KS8995MA Micrel, Inc.
Spanning Tree
Process
PTF1
IGMP Process
Port Mirror
Process
Port VLAN
Membership
Check
PTF2
-Check receiving port's receive enable bit
-Check destination port's transmit enable bit
-Check whether packets are special (BPDU
or specified)
-Applied to MAC #1 to #4
-MAC#5 is reserved for microprocessor
-IGMP will be forwarded to port 5
-RX Mirror
-TX Mirror
-RX or TX Mirror
-RX and TX Mirror
Figure 6. DA Resolution Flowchart–Stage 2
Start
VLAN ID
VALID?
PTF1=NULL
Search Static
Table
Search complete.
Get PTF1 from
static table.
Dynamic
Table
Search
Search complete.
Get PTF1 from
VLAN table.
Search complete.
Get PTF1 from
dynamic table.
PTF1
-Search VLAN table.
-Ingress VLAN filtering
-Discard NPVID check
YES
NO
FOUND
NOT
FOUND
FOUND
NOT
FOUND
Search based on
DA or DA+FID
This search is based on
DA+FID
Figure 5. DA Look-Up Flowchart–Stage 1
KS8995MA Micrel, Inc.
M9999-051305 26 May 2005
Late Collision
If a transmit packet experiences collisions after 512-bit times of the transmission, the packet is dropped.
Illegal Frames
The KS8995MA discards frames of less than 64 bytes and can be programmed to accept frames up to 1536 bytes in Register
4. For special applications, the KS8995MA can also be programmed to accept frames up to 1916 bytes in Register 4. Since
the KS8995MA supports VLAN tags, the maximum size is adjusted when these tags are present.
Flow Control
The KS8995MA supports standard 802.3x flow control frames on both transmit and receive sides.
On the receive side, if the KS8995MA receives a pause control frame, the KS8995MA will not transmit the next normal frame
until the timer, specified in the pause control frame, expires. If another pause frame is received before the current timer expires,
the timer will be updated with the new value given in the second pause frame. During this period of flow control, only flow
controlled packets from the KS8995MA are transmitted.
On the transmit side, the KS8995MA has intelligent and efficient ways to determine when to invoke flow control. The flow control
is based on availability of the system resources, including available buffers, available transmit queues, and available receive
queues.
The KS8995MA flow controls a port that has just received a packet if the destination port resource is busy. The KS8995MA
issues a flow control frame (XOFF), containing the maximum pause time defined in IEEE standard 802.3x. Once the resource
is freed up, the KS8995MA sends out the other flow control frame (XON) with zero pause time to turn off the flow control (turn
on transmission to the port). A hysteresis feature is also provided to prevent over-activation and deactivation of the flow control
mechanism.
The KS8995MA flow controls all ports if the receive queue becomes full.
Half-Duplex Back Pressure
The KS8995MA also provides a half-duplex back pressure option (note: this is not in IEEE 802.3 standards). The activation
and deactivation conditions are the same as the ones given for full-duplex mode. If back pressure is required, the KS8995MA
sends preambles to defer the other station's transmission (carrier sense deference). To avoid jabber and excessive deference
as defined in IEEE 802.3 standard, after a certain period of time, the KS8995MA discontinues carrier sense but raises it quickly
after it drops packets to inhibit other transmissions. This short silent time (no carrier sense) is to prevent other stations from
sending out packets and keeps other stations in a carrier sense deferred state. If the port has packets to send during a back
pressure situation, the carrier-sense-type back pressure is interrupted and those packets are transmitted instead. If there are
no more packets to send, carrier-sense-type back pressure becomes active again until switch resources are free. If a collision
occurs, the binary exponential backoff algorithm is skipped and carrier sense is generated immediately, reducing the chance
of further colliding and maintaining carrier sense to prevent reception of packets.
To ensure no packet loss in 10BASE-T or 100BASE-TX half-duplex modes, the user must enable the following:
Aggressive backoff (Register 3, bit 0)
No excessive collision drop (Register 4, bit 3)
Back pressure (Register 4, bit 5)
These bits are not set as the default because this is not the IEEE standard.
Broadcast Storm Protection
The KS8995MA has an intelligent option to protect the switch system from receiving too many broadcast packets. Broadcast
packets are normally forwarded to all ports except the source port and thus use too many switch resources (bandwidth and
available space in transmit queues). The KS8995MA has the option to include “multicast packets” for storm control. The
broadcast storm rate parameters are programmed globally and can be enabled or disabled on a per port basis. The rate is based
on a 50ms interval for 100BT and a 500ms interval for 10BT. At the beginning of each interval, the counter is cleared to zero
and the rate limit mechanism starts to count the number of bytes during the interval. The rate definition is described in Registers
6 and 7. The default setting for Registers 6 and 7 is 0x4A (74 decimal). This is equal to a rate of 1%, calculated as follows:
148,800 frames/sec ¥ 50ms/interval ¥ 1% = 74 frames/interval (approx.) = 0x4A
MII Interface Operation
The media independent interface (MII) is specified by the IEEE 802.3 committee and provides a common interface between
physical layer and MAC layer devices. The KS8995MA provides two such interfaces. The MII-P5 interface is used to connect
to the fifth PHY, whereas the MII-SW interface is used to connect to the fifth MAC. Each of these MII interfaces contains two
distinct groups of signals, one for transmission and the other for receiving. Table 1 describes the signals used in the MII-P5
interface.
May 2005 27 M9999-051305
KS8995MA Micrel, Inc.
PHY Mode Connection MAC Mode Connection
External KS8995MA External KS8995MA
MAC Signal Description PHY Signal
MTXEN SMTXEN Transmit enable MTXEN SMRXDV
MTXER SMTXER Transmit error MTXER Not used
MTXD3 SMTXD[3] Transmit data bit 3 MTXD3 SMRXD[3]
MTXD2 SMTXD[2] Transmit data bit 2 MTXD2 SMRXD[2]
MTXD1 SMTXD[1] Transmit data bit 1 MTXD1 SMRXD[1]
MTXD0 SMTXD[0] Transmit data bit 0 MTXD0 SMRXD[0]
MTXC SMTXC Transmit clock MTXC SMRXC
MCOL SCOL Collision detection MCOL SCOL
MCRS SCRS Carrier sense MCRS SCRS
MRXDV SMRXDV Receive data valid MRXDV SMTXEN
MRXER Not used Receive error MRXER SMTXER
MRXD3 SMRXD[3] Receive data bit 3 MRXD3 SMTXD[3]
MRXD2 SMRXD[2] Receive data bit 2 MRXD2 SMTXD[2]
MRXD1 SMRXD[1] Receive data bit 1 MRXD1 SMTXD[1]
MRXD0 SMRXD[0] Receive data bit 0 MRXD0 SMTXD[0]
MRXC SMRXC Receive clock MRXC SMTXC
Table 2. MII SW Signals
SNI Signal Description KS8995MA Signal
MTXEN Transmit enable PMTXEN
MTXER Transmit error PMTXER
MTXD3 Transmit data bit 3 PMTXD[3]
MTXD2 Transmit data bit 2 PMTXD[2]
MTXD1 Transmit data bit 1 PMTXD[1]
MTXD0 Transmit data bit 0 PMTXD[0]
MTXC Transmit clock PMTXC
MCOL Collision detection PCOL
MCRS Carrier sense PCRS
MRXDV Receive data valid PMRXDV
MRXER Receive error PMRXER
MRXD3 Receive data bit 3 PMRXD[3]
MRXD2 Receive data bit 2 PMRXD[2]
MRXD1 Receive data bit 1 PMRXD[1]
MRXD0 Receive data bit 0 PMRXD[0]
MRXC Receive clock PMRXC
MDC Management data clock MDC
MDIO Management data I/O MDIO
Table 1. MII P5 Signals (PHY Mode)
KS8995MA Micrel, Inc.
M9999-051305 28 May 2005
The MII-P5 interface operates in PHY mode only, while the MII-SW interface operates in either MAC mode or PHY mode. These
interfaces are nibble-wide data interfaces and therefore run at 1/4 the network bit rate (not encoded). Additional signals on the
transmit side indicate when data is valid or when an error occurs during transmission. Likewise, the receive side has indicators
that convey when the data is valid and without physical layer errors. For half-duplex operation there is a signal that indicates
a collision has occurred during transmission.
Note that the signal MRXER is not provided on the MII-SW interface for PHY mode operation and the signal MTXER is not
provided on the MII-SW interface for MAC mode operation. Normally MRXER would indicate a receive error coming from the
physical layer device. MTXER would indicate a transmit error from the MAC device. These signals are not appropriate for this
configuration. For PHY mode operation, if the device interfacing with the KS8995MA has an MRXER pin, it should be tied low.
For MAC mode operation, if the device interfacing with the KS8995MA has an MTXER pin, it should be tied low.
SNI Interface Operation
The serial network interface (SNI) is compatible with some controllers used for network layer protocol processing. This interface
can be directly connected to these types of devices. The signals are divided into two groups, one for transmission and the other
for reception. The signals involved are described in Table 3.
SNI Signal Description KS8995MA Signal
TXEN Transmit enable SMTXEN
TXD Serial transmit data SMTXD[0]
TXC Transmit clock SMTXC
COL Collision detection SCOL
CRS Carrier sense SMRXDV
RXD Serial receive data SMRXD[0]
RXC Receive clock SMRXC
Table 3. SNI Signals
This interface is a bit-wide data interface and therefore runs at the network bit rate (not encoded). An additional signal on the
transmit side indicates when data is valid. Likewise, the receive side also has an indicator that shows if the data it is receiving
is valid.
For half-duplex operation, there is a signal that indicates if a collision has occurred during transmission.
Advanced Functionality
Spanning Tree Support
Port 5 is the designated port for spanning tree support.
The other ports (port 1 – port 4) can be configured in one of the five spanning tree states via “transmit enable,” “receive enable,”
and “learning disable” register settings in Registers 18, 34, 50, and 66 for ports 1, 2, 3, and 4, respectively. The following
description shows the port setting and software actions taken for each of the five spanning tree states.
Disable state: the port should not forward or receive any packets. Learning is disabled.
Port setting: "transmit enable = 0, receive enable = 0, learning disable = 1."
Software action: the processor should not send any packets to the port. The switch may still send specific packets to the
processor (packets that match some entries in the static table with “overriding bit” set) and the processor should discard those
packets. Note: processor is connected to port 5 via MII interface. Address learning is disabled on the port in this state.
Blocking state: only packets to the processor are forwarded. Learning is disabled.
Port setting: "transmit enable = 0, receive enable = 0, learning disable = 1"
Software action: the processor should not send any packets to the port(s) in this state. The processor should program the
“Static MAC table” with the entries that it needs to receive (e.g., BPDU packets). The “overriding” bit should also be set so that
the switch will forward those specific packets to the processor. Address learning is disabled on the port in this state.
Listening state: only packets to and from the processor are forwarded. Learning is disabled.
Port setting: "transmit enable = 0, receive enable = 0, learning disable = 1."
Software action: The processor should program the static MAC table with the entries that it needs to receive (e.g. BPDU
packets). The “overriding” bit should be set so that the switch will forward those specific packets to the processor. The processor
may send packets to the port(s) in this state, see “Special Tagging Mode” section for details. Address learning is disabled on
the port in this state.
May 2005 29 M9999-051305
KS8995MA Micrel, Inc.
Learning state: only packets to and from the processor are forwarded. Learning is enabled.
Port setting: “transmit enable = 0, receive enable = 0, learning disable = 0.”
Software action: The processor should program the static MAC table with the entries that it needs to receive (e.g., BPDU
packets). The “overriding” bit should be set so that the switch will forward those specific packets to the processor. The processor
may send packets to the port(s) in this state, see “Special Tagging Mode” section for details. Address learning is enabled on
the port in this state.
Forwarding state: packets are forwarded and received normally. Learning is enabled.
Port setting: “transmit enable = 1, receive enable = 1, learning disable = 0.”
Software action: The processor should program the static MAC table with the entries that it needs to receive (e.g., BPDU
packets). The “overriding” bit should be set so that the switch will forward those specific packets to the processor. The processor
may send packets to the port(s) in this state, see “Special Tagging Mode” section for details. Address learning is enabled on
the port in this state.
Special Tagging Mode
The special tagging mode is designed for spanning tree protocol IGMP snooping and is flexible for use in other applications.
The special tagging mode, similar to 802.1q, requires software to change network drivers to insert/modify/strip/interpret the
special tag. This mode is enabled by setting both Register 11 bit 0 and Register 80 bit 2.
802.1q Tag Format Special Tag Format
TPID (tag protocol identifier, 0x8100) + TCI STPID (special tag identifier, 0x8100) + TCI 0x810 + 4 bit for “port mask”) + TCI
Table 4. Special Tagging Mode Format
The STPID will only be seen and used on the port 5 interface, which should be connected to a processor. Packets from the
processor to the switch should be tagged with STPID and the port mask defined as below:
“0001” packet to port 1 only
“0010” packet to port 2 only
“0100” packet to port 3 only
“1000” packet to port 4 only
“0011” packet broadcast to port 1 and port 2.
.....
“1111” packet broadcast to port 1, 2, 3 and 4.
“0000” normal tag, will use the KS8995MA internal look-up result. Normal packets should use this setting. If packets from the
processors do not have a tag, the KS8995MA will treat them as normal packets and an internal look-up will be performed.
The KS8995MA uses a non-zero “port mask” to bypass the look-up result and override any port setting, regardless of port states
(blocking, disable, listening, learning). Table 5 shows the egress rules when dealing with STPID.
KS8995MA Micrel, Inc.
M9999-051305 30 May 2005
Tx Port Tx Port
Ingress Tag Field “Tag Insertion” “Tag Removal” Egress Action to Tag Field
(0x810+ port mask) 0 0 Modify tag field to 0x8100.
Recalculate CRC.
No change to TCI if not null VID.
Replace VID with ingress (port 5) port VID if null VID.
(0x810+ port mask) 0 1 (STPID + TCI) will be removed.
Padding to 64 bytes if necessary.
Recalculate CRC.
(0x810+ port mask) 1 0 Modify tag field to 0x8100.
Recalculate CRC.
No change to TCI if not null VID.
Replace VID with ingress (port 5) port VID if null VID.
(0x810+ port mask) 1 1 Modify tag field to 0x8100.
Recalculate CRC.
No change to TCI if not null VID.
Replace VID with ingress (port 5) port VID if null VID.
Not tagged Don’t care Don’t care Determined by the dynamic MAC address table.
Table 5. STPID Egress Rules (Processor to Switch Port 5)
For packets from regular ports (port 1 - port 4) to port 5, the port mask is used to tell the processor which port the packet was
received on, defined as:
“0001” from port 1,
“0010” from port 2,
“0100” from port 3,
“1000” from port 4
No values other than the previous four defined should be received in this direction in the special mode. Table 6 shows the egress
rule for this direction.
Ingress Packets Egress Action to Tag Field
Tagged with 0x8100 + TCI Modify TPID to 0x810 + “port mask,” which indicates source port.
No change to TCI, if VID is not null.
Replace null VID with ingress port VID.
Recalculate CRC.
Not tagged Insert TPID to 0x810 + “port mask,” which indicates source port.
Insert TCI with ingress port VID.
Recalculate CRC.
Table 6. STPID Egress Rules (Switch to Processor)
IGMP Support
There are two parts involved to support IGMP in Layer 2. The first part is “IGMP” snooping. The switch will trap IGMP packets
and forward them only to the processor port. The IGMP packets are identified as IP packets (either Ethernet IP packets or IEEE
802.3 SNAP IP packets) AND IP version = 0x4 AND protocol number = 0x2. The second part is “multicast address insertion”
in the static MAC table. Once the multicast address is programmed in the static MAC table, the multicast session will be trimmed
to the subscribed ports, instead of broadcasting to all ports. To enable this feature, set Register 5 bit 6 to 1. Also “special tag
mode” needs to be enabled, so that the processor knows which port the IGMP packet was received on. Enable “special tag
mode” by setting both Register 11 bit 0 and Register 80 bit 2.
May 2005 31 M9999-051305
KS8995MA Micrel, Inc.
Port Mirroring Support
KS8995MA supports “port mirror” comprehensively as:
1. “Receive Only” mirror on a port. All the packets received on the port will be mirrored on the sniffer port. For example,
port 1 is programmed to be “rx sniff,” and port 5 is programmed to be the “sniffer port.” A packet, received on port
1, is destined to port 4 after the internal look-up. The KS8995MA will forward the packet to both port 4 and port 5.
KS8995MA can optionally forward even “bad” received packets to port 5.
2. “Transmit Only” mirror on a port. All the packets transmitted on the port will be mirrored on the sniffer port. For
example, port 1 is programmed to be “tx sniff,” and port 5 is programmed to be the “sniffer port.” A packet, received
on any of the ports, is destined to port 1 after the internal look-up. The KS8995MA will forward the packet to both
ports 1 and 5.
3. “Receive and Transmit” mirror on two ports. All the packets received on port A AND transmitted on port B will be
mirrored on the sniffer port. To turn on the “AND” feature, set Register 5 bit 0 to 1. For example, port 1 is programmed
to be “rx sniff,” port 2 is programmed to be “transmit sniff,” and port 5 is programmed to be the “sniffer port.” A packet,
received on port 1, is destined to port 4 after the internal look-up. The KS8995MA will forward the packet to port 4
only, since it does not meet the “AND” condition. A packet, received on port 1, is destined to port 2 after the internal
look-up. The KS8995MA will forward the packet to both port 2 and port 5.
Multiple ports can be selected to be “rx sniffed” or “tx sniffed.” And any port can be selected to be the “sniffer port.” All these
per port features can be selected through Register 17.
VLAN Support
KS8995MA supports 16 active VLANs out of 4096 possible VLANs specified in IEEE 802.1q. KS8995MA provides a 16-entry
VLAN table, which converts VID (12 bits) to FID (4 bits) for address look-up. If a non-tagged or null-VID-tagged packet is
received, the ingress port VID is used for look-up. In the VLAN mode, the look-up process starts with VLAN table look-up to
determine whether the VID is valid. If the VID is not valid, the packet will be dropped and its address will not be learned. If the
VID is valid, FID is retrieved for further look-up. FID+DA is used to determine the destination port. FID+SA is used for learning
purposes.
DA found in DA+FID found in
Static MAC table USE FID Flag? FID Match? Dynamic MAC table Action
No Don’t care Don’t care No Broadcast to the membership ports defined in the
VLAN table bit [20:16].
No Don’t care Don’t care Yes Send to the destination port defined in the
dynamic MAC table bit [54:52].
Yes 0 Don’t care Don’t care Send to the destination port(s) defined in the
static MAC table bit [52:48].
Yes 1 No No Broadcast to the membership ports defined in
the VLAN table bit [20:16].
Yes 1 No Yes Send to the destination port defined in the
dynamic MAC table bit [54:52].
Yes 1 Yes Don’t care Send to the destination port(s) defined in the
static MAC table bit [52:48].
Table 7. FID+DA Look-Up in the VLAN Mode
KS8995MA Micrel, Inc.
M9999-051305 32 May 2005
SA+FID found in
Dynamic MAC table Action
No The SA+FID will be learned into the dynamic table.
Yes Time stamp will be updated.
Table 8. FID+SA Look-Up in the VLAN Mode
Advanced VLAN features are also supported in KS8995MA, such as “VLAN ingress filtering” and “discard non PVID” defined
in Register 18 bit 6 and bit 5. These features can be controlled on a port basis.
Rate Limit Support
KS8995MA supports hardware rate limiting on “receive” and “transmit” independently on a per port basis. It also supports rate
limiting in a priority or non-priority environment. The rate limit starts from 0Kbps and goes up to the line rate in steps of 32Kbps.
The KS8995MA uses one second as an interval. At the beginning of each interval, the counter is cleared to zero, and the rate
limit mechanism starts to count the number of bytes during this interval.
For receive, if the number of bytes exceeds the programmed limit, the switch will stop receiving packets on the port until the
“one second” interval expires. There is an option provided for flow control to prevent packet loss. If the rate limit is programmed
greater than or equal to 128Kbps and the byte counter is 8K bytes below the limit, the flow control will be triggered. If the rate
limit is programmed lower than 128Kbps and the byte counter is 2K bytes below the limit, the flow control will be triggered.
For transmit, if the number of bytes exceeds the programmed limit, the switch will stop transmitting packets on the port until
the “one second” interval expires.
If priority is enabled, the KS8995MA can support different rate controls for both high priority and low priority packets. This can
be programmed through Registers 21–27.
May 2005 33 M9999-051305
KS8995MA Micrel, Inc.
Configuration Interface
The KS8995MA can function as a managed switch or unmanaged switch. If no EEPROM or micro-controller exists, the
KS8995MA will operate from its default setting. Some default settings are configured via strap in options as indicated in the
table below.
Pin # Pin Name PU/PD(1) Description(1)
1MDI-XDIS Ipd Disable auto MDI/MDI-X.
PD = (default) = normal operation.
PU = disable auto MDI/MDI-X on all ports.
45 MUX1 NC Factory test pins. MUX1 and MUX2 should be left unconnected for normal operation.
46 MUX2 NC
Mode MUX1 MUX2
Normal Operation NC NC
62 PMRXD3 Ipd/O PHY[5] MII receive bit 3. Strap option: PD (default) = enable flow control;
PU = disable flow control.
63 PMRXD2 Ipd/O PHY[5] MII receive bit 2. Strap option: PD (default) = disable back pressure;
PU = enable back pressure.
64 PMRXD1 Ipd/O PHY[5] MII receive bit 1. Strap option: PD (default) = drop excessive collision
packets; PU = does not drop excessive collision packets.
65 PMRXD0 Ipd/O PHY[5] MII receive bit 0. Strap option: PD (default) = disable aggressive back-off
algorithm in half-duplex mode; PU = enable for performance enhancement.
66 PMRXER Ipd/O PHY[5] MII receive error. Strap option: PD (default) = 1522/1518 bytes;
PU = packet size up to 1536 bytes.
67 PCRS Ipd/O PHY[5] MII carrier sense/force duplex mode. See “Register 76” for port 4 only.
PD (default) = force half-duplex if auto-negotiation is disabled or fails. PU = force
full-duplex if auto-negotiation is disabled or fails.
68 PCOL Ipd/O PHY[5] MII collision detect/force flow control. See “Register 66” for port 4 only.
PD (default) = no force flow control. PU = force flow control.
80 SMRXD3 Ipd/O Switch MII receive bit 3. Strap option: PD (default) = disable switch MII full-duplex
flow control; PU = enable switch MII full-duplex flow control.
81 SMRXD2 Ipd/O Switch MII receive bit 2. Strap option: PD (default) = switch MII in full-duplex mode;
PU = switch MII in half-duplex mode.
82 SMRXD1 Ipd/O Switch MII receive bit 1. Strap option: PD (default) = switch MII in 100Mbps mode;
PU = switch MII in 10Mbps mode.
83 SMRXD0 Ipd/O Switch MII receive bit 0; Strap option: LED mode PD (default) = mode 0;
PU = mode 1. See “Register 11.”
Mode 0 Mode 1
LEDX_2 Lnk/Act 100Lnk/Act
LEDX_1 Fulld/Col 10Lnk/Act
LEDX_0 Speed Fulld
Note:
1. NC = No connect.
Ipd = Input w/ internal pull-down.
Ipd/O = Input w/ internal pull-down during reset, output pin otherwise.
Fulld = Full duplex.
KS8995MA Micrel, Inc.
M9999-051305 34 May 2005
Pin # Pin Name PU/PD(1) Description1)
86 SCONF1 Ipd Dual MII configuration pin.
Pins 91, 86, 87 Switch MII PHY [5] MII
000 Disable, Otri Disable, Otri
001 PHY Mode MII Disable, Otri
010 MAC Mode MII Disable, Otri
011 PHY Mode SNI Disable, Otri
100 Disable Disable
101 PHY Mode MII PHY Mode MII
110 MAC Mode MII PHY Mode MII
111 PHY Mode SNI PHY Mode MII
87 SCONF0 Ipd Dual MII configuration pin.
90 LED5-2 Ipu/O LED indicator 2. Strap option: Aging setup. See “Aging” section
PU (default) = aging enable; PD = aging disable.
91 LED5-1 Ipu/O LED indicator 1. Strap option: PU (default): enable PHY MII I/F. PD: tristate all PHY
MII output. See “Pin 86 SCONF1.”
113 PS1 Ipd Serial bus configuration pin.
For this case, if the EEPROM is not present, the KS8995MA will start
itself with the PS[1:0] = 00 default register values .
Pin Configuration Serial Bus Configuration
PS[1:0]=00 I2C Master Mode for EEPROM
PS[1:0]=01 Reserved
PS[1:0]=10 SPI Slave Mode for CPU Interface
PS[1:0]=11 Factory Test Mode (BIST)
114 PS0 Ipd Serial bus configuration pin. See “Pin 113.”
128 TEST2 NC NC for normal operation. Factory test pin.
Note:
1. NC = No connect.
Ipd = Input w/ internal pull-down.
Ipu/O = Input w/ internal pull-up during reset, output pin otherwise.
Otri = Output tristated.
May 2005 35 M9999-051305
KS8995MA Micrel, Inc.
I2C Master Serial Bus Configuration
If a 2-wire EEPROM exists, the KS8995MA can perform more advanced features like broadcast storm protection and rate
control. The EEPROM should have the entire valid configuration data from Register 0 to Register 109 defined in the “Memory
Map,” except the status registers. After reset, the KS8995MA will start to read all 110 registers sequentially from the EEPROM.
The configuration access time (tprgm) is less than 15ms as shown in Figure 7.
....
....
....
RST_N
SCL
SDA
t
prgm
<15 ms
Figure 7. KS8995MA EEPROM
Configuration Timing Diagram
To configure the KS8995MA with a pre-configured EEPROM use the following steps:
1. At the board level, connect pin 110 on the KS8995MA to the SCL pin on the EEPROM. Connect pin 111 on the
KS8995MA to the SDA pin on the EEPROM.
2. Set the input signals PS[1:0] (pins 113 and 114, respectively) to “00.” This puts the KS8995MA serial bus
configuration into I2C master mode.
3. Be sure the board-level reset signal is connected to the KS8995MA reset signal on pin 115 (RST_N).
4. Program the contents of the EEPROM before placing it on the board with the desired configuration data. Note that
the first byte in the EEPROM must be “95” for the loading to occur properly. If this value is not correct, all other data
will be ignored.
5. Place EEPROM on the board and power up the board. Assert the active-low board level reset to RST_N on the
KS8995MA. After the reset is de-asserted, the KS8995MA will begin reading configuration data from the EEPROM.
The configuration access time (tprgm) is less than 15ms.
Note: For proper operation, make sure that pin 47 (PWRDN_N) is not asserted during the reset operation.
SPI Slave Serial Bus Configuration
The KS8995MA can also act as an SPI slave device. Through the SPI, the entire feature set can be enabled, including “VLAN,”
“IGMP snooping,” “MIB counters,” etc. The external master device can access any register from Register 0 to Register 127
randomly. The system should configure all the desired settings before enabling the switch in the KS8995MA. To enable the
switch, write a "1" to Register 1 bit 0.
Two standard SPI commands are supported (00000011 for “READ DATA,” and 00000010 for “WRITE DATA”). To speed
configuration time, the KS8995MA also supports multiple reads or writes. After a byte is written to or read from the KS8995MA,
the internal address counter automatically increments if the SPI Slave Select Signal (SPIS_N) continues to be driven low. If
SPIS_N is kept low after the first byte is read, the next byte at the next address will be shifted out on SPIQ. If SPIS_N is kept
low after the first byte is written, bits on the Master Out Slave Input (SPID) line will be written to the next address. Asserting
SPIS_N high terminates a read or write operation. This means that the SPIS_N signal must be asserted high and then low again
before issuing another command and address. The address counter wraps back to zero once it reaches the highest address.
Therefore the entire register set can be written to or read from by issuing a single command and address.
The KS8995MA is able to support a 5MHz SPI bus. A high performance SPI master is recommended to prevent internal counter
overflow.
KS8995MA Micrel, Inc.
M9999-051305 36 May 2005
To use the KS8995MA SPI:
1. At the board level, connect KS8995MA pins as follows:
KS8995MA KS8995MA Microprocessor Signal
Pin Number Signal Name Description
112 SPIS_N SPI Slave Select
110 SPIC SPI Clock
111 SPID Master Out Slave Input
109 SPIQ Master In Slave Output
Table 9. SPI Connections
2. Set the input signals PS[1:0] (pins 113 and 114, respectively) to “10” to set the serial configuration to SPI slave mode.
3. Power up the board and assert a reset signal. After reset wait 100µs, the start switch bit in Register 1 will be set to
‘0’. Configure the desired settings in the KS8995MA before setting the start register to ‘1.'
4. Write configuration to registers using a typical SPI write data cycle as shown in Figure 8 or SPI multiple write as shown
in Figure 10. Note that data input on SPID is registered on the rising edge of SPIC.
5. Registers can be read and configuration can be verified with a typical SPI read data cycle as shown in Figure 9 or
a multiple read as shown in Figure 11. Note that read data is registered out of SPIQ on the falling edge of SPIC.
6. After configuration is written and verified, write a ‘1’ to Register 1 bit 0 to begin KS8995MA operation.
May 2005 37 M9999-051305
KS8995MA Micrel, Inc.
SPIQ
SPIC
SPID
SPIS_N
00000010X A7 A6 A5 A4 A3 A2 A1 A0
WRITE COMMAND WRITE ADDRESS WRITE DATA
D2 D0D1D3D4D5D6D7
Figure 8. SPI Write Data Cycle
SPIQ
SPIC
SPID
SPIS_N
00000011XA7 A6 A5 A4 A3 A2 A1 A0
D7 D6 D5 D4 D3 D2 D1 D0
READ COMMAND READ ADDRESS READ DATA
Figure 9. SPI Read Data Cycle
KS8995MA Micrel, Inc.
M9999-051305 38 May 2005
SPIQ
SPIC
SPID
SPIS_N
00000010X A7 A6 A5 A4 A3 A2 A1 A0
WRITE COMMAND WRITE ADDRESS Byte 1
D2 D0D1D3D4D5D6D7
SPIQ
SPIC
SPID
SPIS_N
D7 D6 D5 D4 D4 D2 D1 D0 D7 D6 D5 D4 D3 D2 D1 D0
Byte 2 Byte 3 ... Byte N
D2 D0D1D3D4D5D6D7
Figure 10. SPI Multiple Write
SPIQ
SPIC
SPID
SPIS_N
00000011XA7 A6 A5 A4 A3 A2 A1 A0
D7 D6 D5 D4 D3 D2 D1 D0
READ COMMAND READ ADDRESS Byte 1
XXXXXXXXXXXXXXXX
Byte 2 Byte 3 ... Byte N
X X X X X X X X
XXXXXXXX
D7 D6 D5 D4 D3 D2 D1 D0
D7 D6 D5 D4 D3 D2 D1 D0 D7 D6 D5 D4 D3 D2 D1 D0
SPIQ
SPIC
SPID
SPIS_N
Figure 11. SPI Multiple Read
MII Management Interface (MIIM)
A standard MIIM interface is provided for all five PHY devices in the KS8995MA. An external device with MDC/MDIO capability
is able to read PHY status or to configure PHY settings. For details on the MIIM interface standard please reference the IEEE
802.3 specification (section 22.2.4.5). The MIIM interface does not have access to all the configuration registers in the
KS8995MA. It can only access the standard MII registers. See “MIIM Registers.” The SPI interface, on the other hand, can
be used to access the entire KS8995MA feature set.
May 2005 39 M9999-051305
KS8995MA Micrel, Inc.
Register Description
Offset
Decimal Hex Description
0-1 0x00-0x01 Chip ID Registers
2-11 0x02-0x0B Global Control Registers
12-15 0x0C-0x0F Reserved
16-29 0x10-0x1D Port 1 Control Registers
30-31 0x1E-0x2F Port 1 Status Registers
32-45 0x20-0x2D Port 2 Control Registers
46-47 0x2E-0x2F Port 2 Status Registers
48-61 0x30-0x3D Port 3 Control Registers
62-63 0x3E-0x3F Port 3 Status Registers
64-77 0x40-0x4D Port 4 Control Registers
78-79 0x4E-0x4F Port 4 Status Registers
80-93 0x50-0x5D Port 5 Control Registers
94-95 0x5E-0x5F Port 5 Status Registers
96-103 0x60-0x67 TOS Priority Control Registers
104-109 0x68-0x6D MAC Address Registers
110-111 0x6E-0x6F Indirect Access Control Registers
112-120 0x70-0x78 Indirect Data Registers
121-122 0x79-0x7A Digital Testing Status Registers
123-124 0x7B-0x7C Digital Testing Control Registers
125-126 0x7D-0x7E Analog Testing Control Registers
127 0x7F Analog Testing Status Register
Global Registers
Address Name Description Mode Default
Register 0 (0x00): Chip ID0
7-0 Family ID Chip family. RO 0x95
Register 1 (0x01): Chip ID1 / Start Switch
7-4 Chip ID 0x0 is assigned to M series. (95MA) RO 0x0
3-1 Revision ID Revision ID RO 0x2
0Start Switch 1, start the chip when external pins (PS1, PS0) = (1,0) RW
or (0,1). Note: in (PS1,PS0) = (0,0) mode, the chip will
start automatically, after trying to read the external
EEPROM. If EEPROM does not exist, the chip will use
default values for all internal registers. If EEPROM is
present, the contents in the EEPROM will be checked.
The switch will check: (1) Register 0 = 0x95,
(2) Register 1 [7:4] = 0x0. If this check is OK, the
contents in the EEPROM will override chip register
default values =0, chip will not start when external pins
(PS1, PS0) = (1,0) or (0,1).
Note: (PS1, PS0) = (1,1) for factory test only.
KS8995MA Micrel, Inc.
M9999-051305 40 May 2005
Address Name Description Mode Default
Register 2 (0x02): Global Control 0
7Reserved Reserved. R/W 0x0
6-4 802.1p Base Priority Used to classify priority for incoming 802.1q packets R/W 0x4
“User priority” is compared against this value
: classified as high priority.
< : classified as low priority.
3Enable PHY MII 1, enable PHY MII interface. R/W Pin LED[5][1]
Note: if not enabled, the switch will tri-state all outputs. strap option.
Pull-down (0):
isolate. Pull-up
(1): Enable.
Note: LED[5][1]
has internal
pull-up.
2Buffer Share Mode 1, buffer pool is shared by all ports. A port can use R/W 0x1
more buffer when other ports are not busy.
0, a port is only allowed to use 1/5 of the buffer pool.
1UNH Mode 1, the switch will drop packets with 0x8808 in T/L R/W 0
filed, or DA=01-80-C2-00-00-01.
0, the switch will drop packets qualified as “flow control”
packets.
0Link Change Age 1, link change from “link” to “no link” will cause fast R/W 0
aging (<800µs) to age address table faster. After an
age cycle is complete, the age logic will return to
normal (300 + 75 seconds ). Note: If any port is
unplugged, all addresses will be automatically aged
out.
Register 3 (0x03): Global Control 1
7Pass All Frames 1, switch all packets including bad ones. Used solely R/W 0
for debugging purpose. Works in conjunction with
sniffer mode.
6Reserved Reserved. R/W 0
5IEEE 802.3x Transmit 0, will enable transmit flow control based on AN result. R/W Pin PMRXD3
Flow Control Disable 1, will not enable transmit flow control regardless of strap option.
AN result. Pull-down(0):
Enable Tx flow
control. Pull-up(1):
Disable Tx/Rx
flow control.
Note: PMRXD3
has internal pull-
down.
4IEEE 802.3x Receive 0, will enable receive flow control based on AN result. R/W Pin PMRXD3 strap
Flow Control Disable 1, will not enable receive flow control regardless of option. Pull-down
AN result. (0): Enable Rx flow
control. Pull-up (1):
Note: Bit 5 and bit 4 default values are controlled by Disable Tx/Rx flow
the same pin, but they can be programmed control.
independently. Note: PMRXD3
has internal pull-
down.
3Frame Length Field Check 1, will check frame length field in the IEEE packets R/W 0
If the actual length does not match, the packet will be
dropped (for L/T <1500) .
May 2005 41 M9999-051305
KS8995MA Micrel, Inc.
Address Name Description Mode Default
2Aging Enable 1, Enable age function in the chip. R/W Pin LED[5][2] strap
0, Disable aging function. option. Pull-down
(0): Aging disable
Pull-up (1): Aging
enable.
Note: LED[5][2]
has internal pull
up.
1Fast age Enable 1 = Turn on fast age (800µs). R/W 0
0Aggressive Back 1 = Enable more aggressive back-off algorithm in half R/W Pin PMRXD0 strap
Off Enable duplex mode to enhance performance. This is not an option. Pull-down
IEEE standard. (0): Disable
aggressive back
off. Pull-up (1):
Aggressive back
off.
Note: PMRXD0
has internal pull
down.
Register 4 (0x04): Global Control 2
7Unicast Port-VLAN This feature is used for port VLAN R/W 1
Mismatch Discard (described in Register 17, Register 33...).
1, all packets can not cross VLAN boundary.
0, unicast packets (excluding unknown/
multicast/broadcast) can cross VLAN boundary.
6Multicast Storm 1, “Broadcast Storm Protection” does not include R/W 1
Protection Disable multicast packets. Only DA=FFFFFFFFFFFF packets
will be regulated.
0, “Broadcast Storm Protection” includes DA =
FFFFFFFFFFFF and DA[40] = 1 packets.
5Back Pressure Mode 1, carrier sense based backpressure is selected. R/W 1
0, collision based backpressure is selected.
4Flow Control and Back 1, fair mode is selected. In this mode, if a flow control R/W 1
Pressure Fair Mode port and a non-flow control port talk to the same
destination port, packets from the non-flow control port
may be dropped. This is to prevent the flow control port
from being flow controlled for an extended period of time.
0, in this mode, if a flow control port and a non-flow
control port talk to the same destination port, the flow
control port will be flow controlled. This may not be “fair”
to the flow control port.
3No Excessive Collision Drop 1, the switch will not drop packets when 16 or more R/W Pin PMRXD1 strap
collisions occur. option. Pull-down
0, the switch will drop packets when 16 or more (0): Drop
collisions occur. excessive collision
packets. Pull-up (1):
Don’t drop
excessive collision
packets.
Note: PMRXD1
has internal pull
down.
2Huge Packet Support 1, will accept packet sizes up to 1916 bytes (inclusive). R/W 0
This bit setting will override setting from bit 1 of the
same register.
0, the max packet size will be determined by bit 1 of this
register.
KS8995MA Micrel, Inc.
M9999-051305 42 May 2005
Address Name Description Mode Default
1Legal Maximum Packet 1, will accept packet sizes up to 1536 bytes (inclusive). R/W Pin PMRXER
Size Check Disable 0, 1522 bytes for tagged packets (not including packets strap option.
with STPID from CPU to ports 1-4), 1518 bytes for Pull-down (0):
untagged packets. Any packets larger than the specified 1518/1522 byte
value will be dropped. packets. Pull-up
(1): 1536 byte
packets.
Note: PMRXER
has internal pull-
down.
0Priority Buffer Reserve 1, each output queue is pre-allocated 48 buffers, R/W 0
used exclusively for high priority packets. It is
recommended to enable this when priority queue
feature is turned on.
0, no reserved buffers for high priority packets.
Register 5 (0x05): Global Control 3
7802.1q VLAN Enable 1, 802.1q VLAN mode is turned on. VLAN table needs R/W 0
to set up before the operation.
0, 802.1q VLAN is disabled.
6IGMP Snoop Enable on 1, IGMP snoop enabled. All the IGMP packets will be R/W 0
Switch MII Interface forwarded to Switch MII port.
0, IGMP snoop disabled.
5Enable Direct Mode on 1, direct mode on port 5. This is a special mode for the R/W 0
Switch MII Interface Switch MII interface. Using preamble before MRXDV to
direct switch to forward packets, bypassing internal
look-up.
0, normal operation.
4Enable Pre-Tag on 1, packets forwarded to Switch MII interface will be R/W 0
Switch MII Interface pre-tagged with the source port number (preamble
before MRXDV).
0, normal operation.
3-2 Priority Scheme Select 00 = always deliver high priority packets first. R/W 00
01 = deliver high/low packets at ratio 10/1.
10 = deliver high/low packets at ratio 5/1.
11 = deliver high/low packets at ratio 2/1.
1Enable “Tag” Mask 1, the last 5 digits in the VID field are used as a mask R/W 0
to determine which port(s) the packet should be
forwarded to.
0, no tag masks.
0Sniff Mode Select 1, will do Rx AND Tx sniff (both source port and R/W 0
destination port need to match).
0, will do Rx OR Tx sniff (Either source port or destination
port needs to match).
This is the mode used to implement Rx only sniff.
Register 6 (0x06): Global Control 4
7Switch MII Back 1, enable half-duplex back pressure on switch MII R/W 0
Pressure Enable interface.
0, disable back pressure on switch MII interface.
6Switch MII Half-Duplex 1, enable MII interface half-duplex mode. R/W Pin SMRXD2 strap
Mode 0, enable MII interface full-duplex mode. option. Pull-down
(0): Full-duplex
mode. Pull-up
(1): Half-duplex
mode. Note:
SMRXD2 has
internal pull-down.
May 2005 43 M9999-051305
KS8995MA Micrel, Inc.
Address Name Description Mode Default(1)
5Switch MII Flow 1, enable full-duplex flow control on switch MII interface. R/W Pin SMRXD3 strap
Control Enable 0, disable full-duplex flow control on switch MII interface. option. Pull-down
(0): disable flow
control. Pull-up(1):
enable flow control.
Note: SMRXD3
has internal pull-
down.
4Switch MII 10BT 1, the switch interface is in 10Mbps mode. R/W Pin SMRXD1 strap
0, the switch interface is in 100Mbps mode. option. Pull-down
(0): Enable
100Mbps. Pull-up
(1): Enable
10Mpbs.
Note: SMRXD1
has internal pull-
down.
3Null VID Replacement 1, will replace null VID with port VID (12 bits). R/W 0
0, no replacement for null VID.
2-0 Broadcast Storm This along with the next register determines how many R/W 000
Protection Rate Bit [10:8] “64 byte blocks” of packet data allowed on an input port
in a preset period. The period is 50ms for 100BT or
500ms for 10BT. The default is 1%.
Register 7 (0x07): Global Control 5
7-0 Broadcast Storm This along with the previous register determines how R/W 0x4A(1)
Protection Rate Bit [7:0] many “64 byte blocks” of packet data are allowed on an
input port in a preset period. The period is 50ms for
100BT or 500ms for 10BT. The default is 1%.
Note:
1. 148,800 frames/sec × 50ms/interval × 1% = 74 frames/interval (approximately) = 0x4A.
Register 8 (0x08): Global Control 6
7-0 Factory Testing Reserved. R/W 0x24
Register 9 (0x09): Global Control 7
7-0 Factory Testing Reserved. R/W 0x28
Register 10 (0x0A): Global Control 8
7-0 Factory Testing Reserved. R/W 0x24
Register 11 (0x0B): Global Control 9
7-4 Reserved N/A 0
3PHY Power 0 = disable PHY power save mode. R/W 0
Save 1 = enable PHY power save mode.
2Factory Setting Reserved. R/W 0
1LED Mode 0 = led mode 0. R/W Pin SMRXD0 strap
1 = led mode 1. option. Pull-down(0):
Enabled led mode 0.
Pull-up(1):
Enabled led mode 1.
Note: SMRXD0 has
internal pull-down 0.
Mode 0 Mode 1
LEDX_2 Lnk/Act 100Lnk/Act
LEDX_1 Fulld/Col 10Lnk/Act
LEDX_0 Speed Fulld
0Special TPID Mode Used for direct mode forwarding from port 5. R/W 0
See “Spanning Tree” functional description.
KS8995MA Micrel, Inc.
M9999-051305 44 May 2005
Port Registers
The following registers are used to enable features that are assigned on a per port basis. The register bit assignments are the
same for all ports, but the address for each port is different, as indicated.
Register 16 (0x10): Port 1 Control 0
Register 32 (0x20): Port 2 Control 0
Register 48 (0x30): Port 3 Control 0
Register 64 (0x40): Port 4 Control 0
Register 80 (0x50): Port 5 Control 0
Address Name Description Mode Default
7Broadcast Storm 1, enable broadcast storm protection for ingress packets R/W 0
Protection Enable on the port.
0, disable broadcast storm protection.
6DiffServ Priority 1, enable DiffServ priority classification for ingress R/W 0
Classification Enable packets on port.
0, disable DiffServ function.
5802.1p Priority 1, enable 802.1p priority classification for ingress R/W 0
Classification Enable packets on port.
0, disable 802.1p.
4Port-Based Priority 1, ingress packets on the port will be classified as high R/W 0
Classification Enable priority if “DiffServ” or “802.1p” classification is not
enabled or fails to classify.
0, ingress packets on port will be classified as low priority
if “DiffServ” or “802.1p” classification is not enabled or
fails to classify.
Note: “DiffServ”, “802.1p” and port priority can be
enabled at the same time. The OR’ed result of 802.1p
and DSCP overwrites the port priority.
3Reserved Reserved. R/W 0
2Tag Insertion 1, when packets are output on the port, the switch will R/W 0
add 802.1q tags to packets without 802.1q tags when
received. The switch will not add tags to packets already
tagged. The tag inserted is the ingress port’s “port VID.”
0, disable tag insertion.
1Tag Removal 1, when packets are output on the port, the switch will R/W 0
remove 802.1q tags from packets with 802.1q tags
when received. The switch will not modify packets
received without tags.
0, disable tag removal.
0Priority Enable 1, the port output queue is split into high and low R/W 0
priority queues.
0, single output queue on the port. There is no priority
differentiation even though packets are classified into
high or low priority.
Register 17 (0x11): Port 1 Control 1
Register 33 (0x21): Port 2 Control 1
Register 49 (0x31): Port 3 Control 1
Register 65 (0x41): Port 4 Control 1
Register 81 (0x51): Port 5 Control 1
Address Name Description Mode Default
7Sniffer Port 1, port is designated as sniffer port and will transmit R/W 0
packets that are monitored.
0, Port is a normal port.
6Receive Sniff 1, all the packets received on the port will be marked R/W 0
as “monitored packets” and forwarded to the designated
“sniffer port.”
0, no receive monitoring.
May 2005 45 M9999-051305
KS8995MA Micrel, Inc.
Address Name Description Mode Default
5Transmit Sniff 1, All the packets transmitted on the port will be marked R/W 0
as “monitored packets” and forwarded to the designated
“sniffer port.”
0, no transmit monitoring.
4-0 Port VLAN Membership Define the port’s “Port VLAN membership.” Bit 4 stands R/W 0x1f
for port 5, bit 3 for port 4...bit 0 for port 1. The port can
only communicate within the membership. A ‘1’ includes
a port in the membership, a ‘0’ excludes a port from
membership.
Register 18 (0x12): Port 1 Control 2
Register 34 (0x22): Port 2 Control 2
Register 50 (0x32): Port 3 Control 2
Register 66 (0x42): Port 4 Control 2
Register 82 (0x52): Port 5 Control 2
Address Name Description Mode Default
7Reserved Reserved. 0x0
6Ingress VLAN Filtering. 1, the switch will discard packets whose VID port R/W 0
membership in VLAN table bit[20:16] does not include
the ingress port.
0, no ingress VLAN filtering.
5Discard Non-PVID Packets. 1, the switch will discard packets whose VID does not R/W 0
match ingress port default VID.
0, no packets will be discarded.
4Force Flow Control 1, will always enable Rx and Tx flow control on the port, R/W 0
regardless of AN result. For port 4 only,
0, the flow control is enabled based on AN result. there is a special
Note: Setting a port for both half-duplex and forced configuration pin
flow control is an illegal configuration. For half-duplex to set the default,
enable back pressure. Pin PCOL strap
option. Pull-down
(0): No Force flow
control. Pull-up
(1): Force flow
control.
Note: PCOL has
internal pull-down.
3Back Pressure Enable 1, enable port’s half-duplex back pressure. R/W Pin PMRXD2 strap
0, disable port’s half-duplex back pressure. option. Pull-down
(0): disable back
pressure. Pull-up
(1): enable back
pressure.
Note: PMRXD2 has
internal pull-down.
2Transmit Enable 1, enable packet transmission on the port. R/W 1
0, disable packet transmission on the port.
1Receive Enable 1, enable packet reception on the port. R/W 1
0, disable packet reception on the port.
0Learning Disable 1, disable switch address learning capability. R/W 0
0, enable switch address learning.
Note:
Bits 2-0 are used for spanning tree support. See “Spanning Tree Support” section.
KS8995MA Micrel, Inc.
M9999-051305 46 May 2005
Register 19 (0x13): Port 1 Control 3
Register 35 (0x23): Port 2 Control 3
Register 51 (0x33): Port 3 Control 3
Register 67 (0x43): Port 4 Control 3
Register 83 (0x53): Port 5 Control 3
Address Name Description Mode Default
7-0 Default Tag [15:8] Port’s default tag, containing: R/W 0
7-5: user priority bits
4: CFI bit
3-0 : VID[11:8]
Register 20 (0x14): Port 1 Control 4
Register 36 (0x24): Port 2 Control 4
Register 52 (0x34): Port 3 Control 4
Register 68 (0x44): Port 4 Control 4
Register 84 (0x54): Port 5 Control 4
Address Name Description Mode Default
7-0 Default Tag [7:0] Default port 1’s tag, containing: R/W 1
7-0: VID[7:0]
Note:
Registers 19 and 20 (and those corresponding to other ports) serve two purposes: (1) associated with the ingress untagged packets, and used for egress
tagging; (2) default VID for the ingress untagged or null-VID-tagged packets, and used for address look-up.
Register 21 (0x15): Port 1 Control 5
Register 37 (0x25): Port 2 Control 5
Register 53 (0x35): Port 3 Control 5
Register 69 (0x45): Port 4 Control 5
Register 85 (0x55): Port 5 Control 5
Address Name Description Mode Default
7-0 Transmit High Priority This along with port control 7, bits [3:0] form a 12-bit R/W 0
Rate Control [7:0] field to determine how many “32Kbps” high priority
blocks can be transmitted (in a unit of 4K bytes in a
one second period).
Register 22 (0x16): Port 1 Control 6
Register 38 (0x26): Port 2 Control 6
Register 54 (0x36): Port 3 Control 6
Register 70 (0x46): Port 4 Control 6
Register 86 (0x56): Port 5 Control 6
Address Name Description Mode Default
7-0 Transmit Low Priority This along with port control 7, bits [7:4] form a 12-bit R/W 0
Rate Control [7:0] field to determine how many “32Kbps” low priority
blocks can be transmitted (in a unit of 4K bytes in a
one second period).
Register 23 (0x17): Port 1 Control 7
Register 39 (0x27): Port 2 Control 7
Register 55 (0x37): Port 3 Control 7
Register 71 (0x47): Port 4 Control 7
Register 87 (0x57): Port 5 Control 7
Address Name Description Mode Default
7-4 Transmit Low Priority This along with port control 6, bits [7:0] form a 12-bit R/W 0
Rate Control [11:8] field to determine how many “32Kbps” low priority
blocks can be transmitted (in a unit of 4K bytes in a
one second period).
3-0 Transmit High Priority This along with port control 5, bits [7:0] form a 12-bit R/W 0
Rate Control [11:8] field to determine how many “32Kbps” high priority
blocks can be transmitted (in unit of 4K bytes in a
one second period).
May 2005 47 M9999-051305
KS8995MA Micrel, Inc.
Register 24 (0x18): Port 1 Control 8
Register 40 (0x28): Port 2 Control 8
Register 56 (0x38): Port 3 Control 8
Register 72 (0x48): Port 4 Control 8
Register 88 (0x58): Port 5 Control 8
Address Name Description Mode Default
7-0 Receive High Priority This along with port control 10, bits [3:0] form a 12-bit R/W 0
Rate Control [7:0] field to determine how many “32Kbps” high priority
blocks can be received (in a unit of 4K bytes in a one
second period).
Register 25 (0x19): Port 1 Control 9
Register 41 (0x29): Port 2 Control 9
Register 57 (0x39): Port 3 Control 9
Register 73 (0x49): Port 4 Control 9
Register 89 (0x59): Port 5 Control 9
Address Name Description Mode Default
7-0 Receive Low Priority This along with port control 10, bits [7:4] form a 12-bit R/W 0
Rate Control [7:0] field to determine how many “32Kbps” low priority
blocks can be received (in a unit of 4K bytes in a one
second period).
Register 26 (0x1A): Port 1 Control 10
Register 42 (0x2A): Port 2 Control 10
Register 58 (0x3A): Port 3 Control 10
Register 74 (0x4A): Port 4 Control 10
Register 90 (0x5A): Port 5 Control 10
Address Name Description Mode Default
7-4 Receive Low Priority This along with port control 9, bits [7:0] form a 12-bit R/W 0
Rate Control [11:8] field to determine how many “32Kbps” low priority
blocks can be received (in a unit of 4K bytes in a one
second period).
3-0 Receive High Priority This along with port control 8, bits [7:0] form a 12-bit R/W 0
Rate Control [11:8] field to determine how many “32Kbps” high priority
blocks can be received (in a unit of 4K bytes in a one
second period).
Register 27 (0x1B): Port 1 Control 11
Register 43 (0x2B): Port 2 Control 11
Register 59 (0x3B): Port 3 Control 11
Register 75 (0x4B): Port 4 Control 11
Register 91 (0x5B): Port 5 Control 11
Address Name Description Mode Default
7Receive Differential 1, If bit 6 is also ‘1’ this will enable receive rate control R/W 0
Priority Rate Control for this port on low priority packets at the low priority
rate. If bit 5 is also ‘1’, this will enable receive rate
control on high priority packets at the high priority rate.
0, receive rate control will be based on the low priority
rate for all packets on this port.
6Low Priority Receive 1, enable port’s low priority receive rate control feature. R/W 0
Rate Control Enable 0, disable port’s low priority receive rate control.
5High Priority Receive 1, If bit 7 is also ‘1’ this will enable the port’s high R/W 0
Rate Control Enable priority receive rate control feature. If bit 7 is a ‘0’ and
bit 6 is a ‘1’, all receive packets on this port will be rate
controlled at the low priority rate.
0, disable port’s high priority receive rate control feature.
4Low Priority Receive Rate 1, flow control may be asserted if the port’s low priority R/W 0
Flow Control Enable receive rate is exceeded.
0, flow control is not asserted if the port’s low priority
receive rate is exceeded.
KS8995MA Micrel, Inc.
M9999-051305 48 May 2005
Address Name Description Mode Default
3High Priority Receive 1, flow control may be asserted if the port’s high R/W 0
Rate Flow Control Enable priority receive rate is exceeded (to use this, differential
receive rate control must be on).
0, flow control is not asserted if the port’s high priority
receive rate is exceeded.
2Transmit Differential 1, will do transmit rate control on both high and low R/W 0
Priority Rate Control priority packets based on the rate counters defined by
the high and low priority packets respectively.
0, will do transmit rate control on any packets.
The rate counters defined in low priority will be used.
1Low Priority Transmit 1, enable the port’s low priority transmit rate control R/W 0
Rate Control Enable feature.
0, disable the port’s low priority transmit rate control
feature.
0High Priority Transmit 1, enable the port’s high priority transmit rate control R/W 0
Rate Control Enable feature
0, disable the port’s high priority transmit rate control
feature.
Register 28 (0x1C): Port 1 Control 12
Register 44 (0x2C): Port 2 Control 12
Register 60 (0x3C): Port 3 Control 12
Register 76 (0x4C): Port 4 Control 12
Register 92 (0x5C): Port 5 Control 12
Address Name Description Mode Default
7Disable Auto-Negotiation 1, disable auto-negotiation, speed and duplex are R/W 0
decided by bit 6 and 5 of the same register.
0, auto-negotiation is on.
6Forced Speed 1, forced 100BT if AN is disabled (bit 7). R/W 1
0, forced 10BT if AN is disabled (bit 7).
5Forced Duplex 1, forced full-duplex if (1) AN is disabled or (2) AN is R/W 0
enabled but failed. For port 4 only,
0, forced half-duplex if (1) AN is disabled or (2) AN is there is a special
enabled but failed. configure pin to set
the default,
Pin PCRS strap
option.
Pull-down (0):
Force half-duplex.
Pull-up (1):
Force full-duplex.
Note: PCRS has
internal pull down.
4Advertised Flow 1, advertise flow control capability. R/W 1
Control Capability 0, suppress flow control capability from transmission
to link partner.
3Advertised 100BT 1, advertise 100BT full-duplex capability. R/W 1
Full-Duplex Capability 0, suppress 100BT full-duplex capability from
transmission to link partner.
2Advertised 100BT 1, advertise 100BT half-duplex capability. R/W 1
Half-Duplex Capability 0, suppress 100BT half-duplex capability from
transmission to link partner.
1Advertised 10BT 1, advertise 10BT full-duplex capability. R/W 0
Full-Duplex Capability 0, suppress 10BT full-duplex capability from
transmission to link partner.
May 2005 49 M9999-051305
KS8995MA Micrel, Inc.
Address Name Description Mode Default
0Advertised 10BT 1, advertise 10BT half-duplex capability. R/W 1
Half-Duplex Capability 0, suppress 10BT half-duplex capability from
transmission to link partner.
Note:
Port Control 12 and 13, and Port Status 0 contents can be accessed by MIIM (MDC/MDIO) interface via the standard MIIM register definition.
Register 29 (0x1D): Port 1 Control 13
Register 45 (0x2D): Port 2 Control 13
Register 61 (0x3D): Port 3 Control 13
Register 77 (0x4D): Port 4 Control 13
Register 93 (0x5D): Port 5 Control 13
Address Name Description Mode Default
7LED Off 1, Turn off all port’s LEDs (LEDx_2, LEDx_1, LEDx_0, R/W 0
where “x” is the port number). These pins will be driven
high if this bit is set to one.
0, normal operation.
6Txids 1, disable port’s transmitter. R/W 0
0, normal operation.
5Restart AN 1, restart auto-negotiation. R/W 0
0, normal operation.
4Disable Far End Fault 1, disable far end fault detection and pattern transmission. R/W 0
0, enable far end fault detection and pattern transmission.
3Power Down 1, power down. R/W 0
0, normal operation.
2Disable Auto MDI/MDI-X 1, disable auto MDI/MDI-X function. R/W 0
0, enable auto MDI/MDI-X function.
1Forced MDI 1, If auto MDI/MDI-X is disabled, force PHY into R/W 0
MDI mode.
0, Do not force PHY into MDI mode.
0MAC Loopback 1, Perform MAC loopback. R/W 0
0, normal operation.
Register 30 (0x1E): Port 1 Status 0
Register 46 (0x2E): Port 2 Status 0
Register 62 (0x3E): Port 3 Status 0
Register 78 (0x4E): Port 4 Status 0
Register 94 (0x5E): Port 5 Status 0
Address Name Description Mode Default
7MDI-X Status 1, MDI. RO 0
0, MDI-X.
6AN Done 1, AN done. RO 0
0, AN not done.
5Link Good 1, link good. RO 0
0, link not good.
4Partner Flow 1, link partner flow control capable. RO 0
Control Capability 0, link partner not flow control capable.
3Partner 100BT 1, link partner 100BT full-duplex capable. RO 0
Full-Duplex Capability 0, link partner not 100BT full-duplex capable.
2Partner 100BT 1, link partner 100BT half-duplex capable. RO 0
Half-Duplex Capability 0, link partner not 100BT half-duplex capable.
1Partner 10BT 1, link partner 10BT full-duplex capable. RO 0
Full-Duplex Capability 0, link partner not 10BT full-duplex capable.
0Partner 10BT 1, link partner 10BT half-duplex capable. RO 0
Half-Duplex Capability 0, link partner not 10BT half-duplex capable.
KS8995MA Micrel, Inc.
M9999-051305 50 May 2005
Register 31 (0x1F): Port 1 Control 14
Register 47 (0x2F): Port 2 Control 14
Register 63 (0x3F): Port 3 Control 14
Register 79 (0x4F): Port 4 Control 14
Register 95 (0x5F): Port 5 Control 14
Address Name Description Mode Default
7PHY Loopback 1, perform PHY loopback, i.e. loopback MAC’s Tx R/W 0
back to Rx.
0, normal operation.
6Remote Loopback 1, perform remote loopback, i.e. loopback PHY’s Rx R/W 0
back to Tx.
0, normal operation.
5PHY Isolate 1, electrical isolation of PHY from MII and Tx+/Tx-. R/W 0
0, normal operation.
4Soft Reset 1, PHY soft reset. R/W 0
0, normal operation.
3Force Link 1, Force link in the PHY. R/W 0
0, normal operation.
2-1 Reserved N/A RO 0
0Far End Fault 1, Far end fault status detected. RO 0
0, no far end fault status detected.
Advanced Control Registers
The IPv4 TOS priority control registers implement a fully decoded 64 bit differentiated services code point (DSCP) register used
to determine priority from the 6 bit TOS field in the IP header. The most significant 6 bits of the TOS field are fully decoded into
64 possibilities, and the singular code that results is compared against the corresponding bit in the DSCP register. If the register
bit is a 1, the priority is high; if the register bit is a 0, the priority is low.
Address Name Description Mode Default
Register 96 (0x60): TOS Priority Control Register 0
7-0 DSCP[63:56] R/W 00000000
Register 97 (0x61): TOS Priority Control Register 1
7-0 DSCP[55:48] R/W 00000000
Register 98 (0x62): TOS Priority Control Register 2
7-0 DSCP[47:40] R/W 00000000
Register 99 (0x63): TOS Priority Control Register 3
7-0 DSCP[39:32] R/W 00000000
Register 100 (0x64): TOS Priority Control Register 4
7-0 DSCP[31:24] R/W 00000000
Register 101 (0x65): TOS Priority Control Register 5
7-0 DSCP[23:16] R/W 00000000
Register 102 (0x66): TOS Priority Control Register 6
7-0 DSCP[15:8] R/W 00000000
Register 103 (0x67): TOS Priority Control Register 7
7-0 DSCP[7:0] R/W 00000000
Registers 104 to 109 define the switching engine’s MAC address. This 48-bit address is used as the source address in MAC pause control frames.
Register 104 (0x68): MAC Address Register 0
7-0 MACA[47:40] R/W 0x00
Register 105 (0x69): MAC Address Register 1
7-0 MACA[39:32] R/W 0x10
May 2005 51 M9999-051305
KS8995MA Micrel, Inc.
Address Name Description Mode Default
Register 106 (0x6A): MAC Address Register 2
7-0 MACA[31:24] R/W 0xA1
Register 107 (0x6B): MAC Address Register 3
7-0 MACA[23:16] R/W 0xff
Register 108 (0x6C): MAC Address Register 4
7-0 MACA[15:8] R/W 0xff
Register 109 (0X6D): MAC Address Register 5
7-0 MACA[7:0] R/W 0xff
Use registers 110 and 111 to read or write data to the static MAC address table, VLAN table, dynamic address table, or the MIB counters.
Address Name Description Mode Default
Register 110 (0x6E): Indirect Access Control 0
7-5 Reserved Reserved. R/W 000
4Read High Write Low 1, read cycle. R/W 0
0, write cycle.
3-2 Table Select 00 = static mac address table selected. R/W 0
01 = VLAN table selected.
10 = dynamic address table selected.
11 = MIB counter selected.
1-0 Indirect Address High Bit 9-8 of indirect address. R/W 00
Register 111 (0x6F): Indirect Access Control 1
7-0 Indirect Address Low Bit 7-0 of indirect address. R/W 00000000
Note:
Write to Register 111 will actually trigger a command. Read or write access will be decided by bit 4 of Register 110.
Address Name Description Mode Default
Register 112 (0x70): Indirect Data Register 8
68-64 Indirect Data Bit 68-64 of indirect data. R/W 00000
Register 113 (0x71): Indirect Data Register 7
63-56 Indirect Data Bit 63-56 of indirect data. R/W 00000000
Register 114 (0x72): Indirect Data Register 6
55-48 Indirect Data Bit 55-48 of indirect data. R/W 00000000
Register 115 (0x73): Indirect Data Register 5
47-40 Indirect Data Bit 47-40 of indirect data. R/W 00000000
Register 116 (0x74): Indirect Data Register 4
39-32 Indirect Data Bit 39-32 of indirect data. R/W 00000000
Register 117 (0x75): Indirect Data Register 3
31-24 Indirect Data Bit of 31-24 of indirect data R/W 00000000
Register 118 (0x76): Indirect Data Register 2
23-16 Indirect Data Bit 23-16 of indirect data. R/W 00000000
Register 119 (0x77): Indirect Data Register 1
15-8 Indirect Data Bit 15-8 of indirect data. R/W 00000000
Register 120 (0x78): Indirect Data Register 0
7-0 Indirect Data Bit 7-0 of indirect data. R/W 00000000
Do not write or read to/from Register isters 121 to 127. Doing so may prevent proper operation. Micrel internal testing only.
KS8995MA Micrel, Inc.
M9999-051305 52 May 2005
Address Name Description Mode Default
Register 121 (0x79): Digital Testing Status 0
7-0 Factory Testing Reserved. RO 0x0
Qm_split status
Register 122 (0x7A): Digital Testing Status 1
7-0 Factory Testing Reserved. RO 0x0
Dbg[7:0]
Register 123 (0x7B): Digital Testing Control 0
7-0 Factory Testing Reserved. R/W 0x0
Dbg[12:8]
Register 124 (0x7C): Digital Testing Control 1
7-0 Factory Testing Reserved. R/W 0x0
Register 125 (0x7D): Analog Testing Control 0
7-0 Factory Testing Reserved. R/W 0x0
Register 126 (0x7E): Analog Testing Control 1
7-0 Factory Testing Reserved. R/W 0x0
Register 127 (0x7F): Analog Testing Status
7-0 Factory Testing Reserved. RO 0x0
May 2005 53 M9999-051305
KS8995MA Micrel, Inc.
Static MAC Address
KS8995MA has a static and a dynamic address table. When a DA look-up is requested, both tables will be searched to make
a packet forwarding decision. When an SA look-up is requested, only the dynamic table is searched for aging, migration, and
learning purposes. The static DA look-up result will have precedence over the dynamic DA look-up result. If there are DA
matches in both tables, the result from the static table will be used. The static table can only be accessed and controlled by
an external SPI master (usually a processor). The entries in the static table will not be aged out by KS8995MA. An external
device does all addition, modification and deletion.
Note:
Register bit assignments are different for static MAC table reads and static MAC table write, as shown in the two tables below.
Address Name Description Mode Default
Format of Static MAC Table for Reads (8 entries)
60-57 FID Filter VLAN ID, representing one of the 16 active VLANs. RO 0000
56 Use FID 1, use (FID+MAC) to look-up in static table. RO 0
0, use MAC only to look-up in static table.
55 Reserved Reserved. RO N/A
54 Override 1, override spanning tree “transmit enable = 0” or RO 0
“receive enable = 0” setting. This bit is used for
spanning tree implementation.
0, no override.
53 Valid 1, this entry is valid, the look-up result will be used. RO 0
0, this entry is not valid.
52-48 Forwarding Ports The 5 bits control the forward ports, example: RO 00000
00001, forward to port 1
00010, forward to port 2
.....
10000, forward to port 5
00110, forward to port 2 and port 3
11111, broadcasting (excluding the ingress port)
47-0 MAC Address 48 bit MAC address. RO 0x0
Format of Static MAC Table for Writes (8 entries)
59-56 FID Filter VLAN ID, representing one of the 16 active VLANs. W 0000
55 Use FID 1, use (FID+MAC) to look-up in static table.
0, use MAC only to look-up in static table. W 0
54 Override 1, override spanning tree “transmit enable = 0” or W 0
“receive enable = 0” setting. This bit is used for
spanning tree implementation.
0, no override.
53 Valid 1, this entry is valid, the look-up result will be used. W 0
0, this entry is not valid.
52-48 Forwarding Ports The 5 bits control the forward ports, example: W 00000
00001, forward to port 1
00010, forward to port 2
.....
10000, forward to port 5
00110, forward to port 2 and port 3
11111, broadcasting (excluding the ingress port)
47-0 MAC Address 48-bit MAC address. W 0x0
Table 12. Static MAC Address Table
KS8995MA Micrel, Inc.
M9999-051305 54 May 2005
Examples:
(1) Static Address Table Read (read the 2nd entry)
Write to Register 110 with 0x10 (read static table selected)
Write to Register 111 with 0x1 (trigger the read operation)
Then
Read Register 113 (60-56)
Read Register 114 (55-48)
Read Register 115 (47-40)
Read Register 116 (39-32)
Read Register 117 (31-24)
Read Register 118 (23-16)
Read Register 119 (15-8)
Read Register 120 (7-0)
(2) Static Address Table Write (write the 8th entry)
Write Register 113 (59-56)
Write Register 114 (55-48)
Write Register 115 (47-40)
Write Register 116 (39-32)
Write Register 117 (31-24)
Write Register 118 (23-16)
Write Register 119 (15-8)
Write Register 120 (7-0)
Write to Register 110 with 0x00 (write static table selected)
Write to Register 111 with 0x7 (trigger the write operation)
May 2005 55 M9999-051305
KS8995MA Micrel, Inc.
Address Name Description Mode Default
Format of Static VLAN Table (16 entries)
21 Valid 1, the entry is valid. R/W 1
0, entry is invalid.
20-16 Membership Specify which ports are members of the VLAN. R/W 11111
If a DA look-up fails (no match in both static and
dynamic tables), the packet associated with this VLAN
will be forwarded to ports specified in this field.
E.g., 11001 means port 5, 4, and 1 are in this VLAN.
15-12 FID Filter ID. KS8995MA supports 16 active VLANs R/W 0
represented by these four bit fields. FID is the mapped
ID. If 802.1q VLAN is enabled, the look-up will be based
on FID+DA and FID+SA.
11-0 VID IEEE 802.1q 12 bit VLAN ID. R/W 1
Table 13. VLAN Table
VLAN Address
The VLAN table is used for VLAN table look-up. If 802.1q VLAN mode is enabled (Register 5 bit 7 =1), this table is used to
retrieve VLAN information that is associated with the ingress packet. The information includes FID (filter ID), VID (VLAN ID),
and VLAN membership described below:
If 802.1q VLAN mode is enabled, KS8995MA assigns a VID to every ingress packet. If the packet is untagged or tagged with
a null VID, the packet is assigned with the default port VID of the ingress port. If the packet is tagged with non-null VID, the
VID in the tag is used. The look-up process starts from the VLAN table look-up. If the VID is not valid, the packet is dropped
and no address learning occurs. If the VID is valid, the FID is retrieved. The FID+DA and FID+SA lookups are performed. The
FID+DA look-up determines the forwarding ports. If FID+DA fails, the packet is broadcast to all the members (excluding the
ingress port) of the VLAN. If FID+SA fails, the FID+SA is learned.
Examples:
(1) VLAN Table Read (read the 3rd entry)
Write to Register 110 with 0x14 (read VLAN table selected)
Write to Register 111 with 0x2 (trigger the read operation)
Then
Read Register 118 (VLAN table bits 21-16)
Read Register 119 (VLAN table bits 15-8)
Read Register 120 (VLAN table bits 7-0)
(2) VLAN Table Write (write the 7th entry)
Write to Register 118 (VLAN table bits 21-16)
Write to Register 119 (VLAN table bits 15-8)
Write to Register 120 (VLAN table bits 7-0)
Write to Register 110 with 0x04 (write static table selected)
Write to Register 111 with 0x6 (trigger the write operation)
KS8995MA Micrel, Inc.
M9999-051305 56 May 2005
Address Name Description Mode Default
Format of Dynamic MAC Address Table (1K entries)
68 MAC Empty 1, there is no valid entry in the table. RO 1
0, there are valid entries in the table.
67-58 No of Valid Entries Indicates how many valid entries in the table. RO 0
0x3ff means 1K entries
0x1 means 2 entries
0x0 and bit 68 = 0: means 1 entry
0x0 and bit 68 = 1: means 0 entry
57-56 Time Stamp 2-bit counters for internal aging RO
55 Data Ready 1, The entry is not ready, retry until this bit is set to 0. RO
0, The entry is ready.
54-52 Source Port The source port where FID+MAC is learned. RO 0x0
000 port 1
001 port 2
010 port 3
011 port 4
100 port 5
51-48 FID Filter ID. RO 0x0
47-0 MAC Address 48-bit MAC address. RO 0x0
Table 14. Dynamic MAC Address Table
Examples:
(1) Dynamic MAC Address Table Read (read the 1st entry), and retrieve the MAC table size
Write to Register 110 with 0x18 (read dynamic table selected)
Write to Register 111 with 0x0 (trigger the read operation )
Then
Read Register 112 (68-64)
Read Register 113 (63-56); // the above two registers show # of entries
Read Register 114 (55-48) // if bit 55 is 1, restart (reread) from this register
Read Register 115 (47-40)
Read Register 116 (39-32)
Read Register 117 (31-24)
Read Register 118 (23-16)
Read Register 119 (15-8)
Read Register 120 (7-0)
(2) Dynamic MAC Address Table Read (read the 257th entry), without retrieving # of entries information
Write to Register 110 with 0x19 (read dynamic table selected)
Write to Register 111 with 0x1 (trigger the read operation)
Then
Read Register 114 (55-48) // if bit 55 is 1, restart (reread) from this register ister
Read Register 115 (47-40)
Read Register 116 (39-32)
Read Register 117 (31-24)
Read Register 118 (23-16)
Read Register 119 (15-8)
Read Register 120 (7-0)
Dynamic MAC Address
This table is read only. The contents are maintained by the KS8995MA only.
May 2005 57 M9999-051305
KS8995MA Micrel, Inc.
MIB Counters
The MIB counters are provided on per port basis. The indirect memory is as below:
For port 1
Offset Counter Name Description
0x0 RxLoPriorityByte Rx lo-priority (default) octet count including bad packets.
0x1 RxHiPriorityByte Rx hi-priority octet count including bad packets.
0x2 RxUndersizePkt Rx undersize packets w/good CRC.
0x3 RxFragments Rx fragment packets w/bad CRC, symbol errors or alignment errors.
0x4 RxOversize Rx oversize packets w/good CRC (max: 1536 or 1522 bytes).
0x5 RxJabbers Rx packets longer than 1522B w/either CRC errors, alignment errors, or symbol errors
(depends on max packet size setting).
0x6 RxSymbolError Rx packets w/ invalid data symbol and legal packet size.
0x7 RxCRCerror Rx packets within (64,1522) bytes w/an integral number of bytes and a bad CRC
(upper limit depends on max packet size setting).
0x8 RxAlignmentError Rx packets within (64,1522) bytes w/a non-integral number of bytes and a bad CRC
(upper limit depends on max packet size setting).
0x9 RxControl8808Pkts The number of MAC control frames received by a port with 88-08h in EtherType field.
0xA RxPausePkts The number of PAUSE frames received by a port. PAUSE frame is qualified with
EtherType (88-08h), DA, control opcode (00-01), data length (64B min), and a valid CRC.
0xB RxBroadcast Rx good broadcast packets (not including errored broadcast packets or valid multicast
packets).
0xC RxMulticast Rx good multicast packets (not including MAC control frames, errored multicast packets or
valid broadcast packets).
0xD RxUnicast Rx good unicast packets.
0xE Rx64Octets Total Rx packets (bad packets included) that were 64 octets in length.
0xF Rx65to127Octets Total Rx packets (bad packets included) that are between 65 and 127 octets in length.
0x10 Rx128to255Octets Total Rx packets (bad packets included) that are between 128 and 255 octets in length.
0x11 Rx256to511Octets Total Rx packets (bad packets included) that are between 256 and 511 octets in length.
0x12 Rx512to1023Octets Total Rx packets (bad packets included) that are between 512 and 1023 octets in length.
0x13 Rx1024to1522Octets Total Rx packets (bad packets included) that are between 1024 and 1522 octets in length
(upper limit depends on max packet size setting).
0x14 TxLoPriorityByte Tx lo-priority good octet count, including PAUSE packets.
0x15 TxHiPriorityByte Tx hi-priority good octet count, including PAUSE packets.
0x16 TxLateCollision The number of times a collision is detected later than 512 bit-times into the Tx of a packet.
0x17 TxPausePkts The number of PAUSE frames transmitted by a port.
0x18 TxBroadcastPkts Tx good broadcast packets (not including errored broadcast or valid multicast packets).
0x19 TxMulticastPkts Tx good multicast packets (not including errored multicast packets or valid broadcast
packets).
0x1A TxUnicastPkts Tx good unicast packets.
0x1B TxDeferred Tx packets by a port for which the 1st Tx attempt is delayed due to the busy medium.
0x1C TxTotalCollision Tx total collision, half-duplex only.
0x1D TxExcessiveCollision A count of frames for which Tx fails due to excessive collisions.
0x1E TxSingleCollision Successfully Tx frames on a port for which Tx is inhibited by exactly one collision.
0x1F TxMultipleCollision Successfully Tx frames on a port for which Tx is inhibited by more than one collision.
Table 15. Port-1 MIB Counter Indirect Memory Offsets
KS8995MA Micrel, Inc.
M9999-051305 58 May 2005
For port 2, the base is 0x20, same offset definition (0x20-0x3f)
For port 3, the base is 0x40, same offset definition (0x40-0x5f)
For port 4, the base is 0x60, same offset definition (0x60-0x7f)
For port 5, the base is 0x80, same offset definition (0x80-0x9f)
Address Name Description Mode Default
Format of Per Port MIB Counters (16 entries)
31 Overflow 1, Counter overflow. RO 0
0, No Counter overflow.
30 Count Valid 1, Counter value is valid. RO 0
0, Counter value is not valid.
29-0 Counter Values Counter value. RO 0
Offset Counter Name Description
0x100 Port1 Tx Drop Packets Tx packets dropped due to lack of resources.
0x101 Port2 Tx Drop Packets Tx packets dropped due to lack of resources.
0x102 Port3 Tx Drop Packets Tx packets dropped due to lack of resources.
0x103 Port4 Tx Drop Packets Tx packets dropped due to lack of resources.
0x104 Port5 Tx Drop Packets Tx packets dropped due to lack of resources.
0x105 Port1 Rx Drop Packets Rx packets dropped due to lack of resources.
0x106 Port2 Rx Drop Packets Rx packets dropped due to lack of resources.
0x107 Port3 Rx Drop Packets Rx packets dropped due to lack of resources.
0x108 Port4 Rx Drop Packets Rx packets dropped due to lack of resources.
0x109 Port5 Rx Drop Packets Rx packets dropped due to lack of resources.
Table 16. All Port Dropped Packet MIB Counters
Address Name Description Mode Default
Format of All Port Dropped Packet MIB Counters
30-16 Reserved Reserved. N/A N/A
15-0 Counter Values Counter value. RO 0
Note:
All port dropped packet MIB counters do not indicate overflow or validity; therefore the application must keep track of overflow and valid conditions.
Examples:
(1) MIB counter read (read port 1 rx 64 counter)
Write to Register 110 with 0x1c (read MIB counters
selected)
Write to Register 111 with 0xe (trigger the read operation)
Then
Read Register 117 (counter value 31-24)
// If bit 31 = 1, there was a counter overflow
// If bit 30 = 0, restart (reread) from this register
Read Register 118 (counter value 23-16)
Read Register 119 (counter value 15-8)
Read Register 120 (counter value 7-0)
May 2005 59 M9999-051305
KS8995MA Micrel, Inc.
(2) MIB counter read (read port 2 rx 64 counter)
Write to Register 110 with 0x1c
(read MIB counter selected)
Write to Register 111 with 0x2e
(trigger the read operation )
Then
Read Register 117 (counter value 31-24)
// If bit 31 = 1, there was a counter overflow
// If bit 30 = 0, restart (reread) from this register
Read Register 118 (counter value 23-16)
Read Register 119 (counter value 15-8)
Read Register 120 (counter value 7-0)
(3) MIB counter read (read port 1 tx drop packets)
Write to Register 110 with 0x1d
Write to Register 111 with 0x00
Then
Read Register 119 (counter value 15-8)
Read Register 120 (counter value 7-0)
Note:
To read out all the counters, the best performance over the SPI bus is (160+3) ×8×200 = 260ms, where there are 160 registers, 3 overhead, 8 clocks per
access, at 5MHz. In the heaviest condition, the byte counter will overflow in 2 minutes. It is recommended that the software read all the counters at least
every 30 seconds. The per port MIB counters are designed as “read clear.” A per port MIB counter will be cleared after it is accessed. All port dropped
packet MIB counters are not cleared after they are accessed. The application needs to keep track of overflow and valid conditions on these counters.
KS8995MA Micrel, Inc.
M9999-051305 60 May 2005
Address Name Description Mode Default
Register 0: MII Control
15 Soft Reset 1, PHY soft reset. R/W 0
0, Normal operation.
14 Loop Back 1, Loop back mode (loopback at MAC). R/W 0
0, Normal operation.
13 Force 100 1, 100Mbps. R/W 1
0, 10Mbps.
12 AN Enable 1, Auto-negotiation enabled. R/W 1
0, Auto-negotiation disabled.
11 Power Down 1, Power down. R/W 0
0, Normal operation.
10 PHY Isolate 1, Electrical PHY isolation of PHY from Tx+/Tx-. R/W 0
0, Normal operation.
9Restart AN 1, Restart Auto-negotiation. R/W 0
0, Normal operation.
8Force Full Duplex 1, Full duplex. R/W 0
0, Half duplex.
7Collision Test Not supported. RO 0
6Reserved RO 0
5Reserved RO 0
4Force MDI 1, Force MDI. R/W 0
0, Normal operation.
3Disable Auto MDI/MDI-X 1, Disable auto MDI/MDI-X. R/W 0
0, Normal operation.
2Disable Far End Fault 1, Disable far end fault detection. R/W 0
0, Normal operation.
1Disable Transmit 1, Disable transmit. R/W 0
0, Normal operation.
0Disable LED 1, Disable LED. R/W 0
0, Normal operation.
MIIM Registers
All the registers defined in this section can be also accessed via the SPI interface. Note: different mapping mechanisms used
for MIIM and SPI. The “PHYAD” defined in IEEE is assigned as “0x1” for port 1, “0x2” for port 2, “0x3” for port 3, “0x4” for port
4, and “0x5” for port 5. The “REGAD” supported are 0,1,2,3,4,5.
May 2005 61 M9999-051305
KS8995MA Micrel, Inc.
Address Name Description Mode Default
Register 1: MII Status
15 T4 Capable 0, Not 100 BASET4 capable. RO 0
14 100 Full Capable 1, 100BASE-TX full-duplex capable. RO 1
0, Not capable of 100BASE-TX full-duplex.
13 100 Half Capable 1, 100BASE-TX half-duplex capable. RO 1
0, Not 100BASE-TX half-duplex capable.
12 10 Full Capable 1, 10BASE-T full-duplex capable. RO 1
0, Not 10BASE-T full-duplex capable.
11 10 Half Capable 1, 10BASE-T half-duplex capable. RO 1
0, 10BASE-T half-duplex capable.
10-7 Reserved RO 0
6Preamble Suppressed Not supported. RO 0
5AN Complete 1, Auto-negotiation complete. RO 0
0, Auto-negotiation not completed.
4Far End Fault 1, Far end fault detected. RO 0
0, No far end fault detected.
3AN Capable 1, Auto-negotiation capable. RO 1
0, Not auto-negotiation capable.
2Link Status 1, Link is up. RO 0
0, Link is down.
1Jabber Test Not supported. RO 0
0Extended Capable 0, Not extended register capable. RO 0
Register 2: PHYID HIGH
15-0 Phyid High High order PHYID bits. RO 0x0022
Register 3: PHYID LOW
15-0 Phyid Low Low order PHYID bits. RO 0x1450
Register 4: Advertisement Ability
15 Next Page Not supported. RO 0
14 Reserved RO 0
13 Remote Fault Not supported. RO 0
12-11 Reserved RO 0
10 Pause 1, Advertise pause ability. R/W 1
0, Do not advertise pause ability.
9Reserved R/W 0
8Adv 100 Full 1, Advertise 100 full-duplex ability. R/W 1
0, Do not advertise 100 full-duplex ability.
7Adv 100 Half 1, Advertise 100 half-duplex ability. R/W 1
0, Do not advertise 100 half-duplex ability.
6Adv 10 Full 1, Advertise 10 full-duplex ability. R/W 1
0, Do not advertise 10 full-duplex ability.
5Adv 10 Half 1, Advertise 10 half-duplex ability. R/W 1
0, Do not advertise 10 half-duplex ability.
4-0 Selector Field 802.3 RO 00001
KS8995MA Micrel, Inc.
M9999-051305 62 May 2005
Address Name Description Mode Default
Register 5: Link Partner Ability
15 Next Page Not supported. RO 0
14 LP ACK Not supported. RO 0
13 Remote Fault Not supported. RO 0
12-11 Reserved RO 0
10 Pause Link partner pause capability. RO 0
9Reserved RO 0
8Adv 100 Full Link partner 100 full capability. RO 0
7Adv 100 Half Link partner 100 half capability. RO 0
6Adv 10 Full Link partner 10 full capability. RO 0
5Adv 10 Half Link partner 10 half capability. RO 0
4-0 Reserved RO 00001
May 2005 63 M9999-051305
KS8995MA Micrel, Inc.
Absolute Maximum Ratings(1)
Supply Voltage
(VDDAR, VDDAP, VDDC)............................. –0.5V to +2.4V
(VDDAT, VDDIO)........................................ –0.5V to +4.0V
Input Voltage ............................................... –0.5V to +4.0V
Output Voltage ............................................ –0.5V to +4.0V
Lead Temperature (soldering, 10 sec.) ..................... 270°C
Storage Temperature (TS) ....................... –55°C to +150°C
Operating Ratings(2)
Supply Voltage
(VDDAR, VDDAP, VDDC)............................. +1.7V to +1.9V
(VDDAT)................... +3.15V to +3.45V or +2.4V to +2.6V
(VDDIO)................................................ +3.15V to +3.45V
Ambient Temperature (TA)
Commercial .............................................. –0°C to +70°C
Industrial ................................................. –40°C to +85°C
Package Thermal Resistance(3)
PQFP (θJA) No Air Flow ................................. 59.47°C/W
Electrical Characteristics(4, 5)
Symbol Parameter Condition Min Typ Max Units
100BASE-TX Operation All Ports 100% Utilization
IDX 100BASE-TX (Transmitter) VDDAT 229 250 mA
IDDC
100BASE-TX (Digital Core/PLL + Analog Rx)
VDDC, VDDAP, VDDAR 157 230 mA
IDDIO 100BASE-TX (Digital IO) VDDIO 17 30 mA
10BASE-TX Operation All Ports 100% Utilization
IDX 10BASE-TX (Transmitter) VDDAT 350 375 mA
IDDC
10BASE-TX (Digital Core + Analog Rx)
VDDC, VDDAP 102 180 mA
IDDIO 10BASE-TX (Digital IO) VDDIO 615mA
Auto-Negotiation Mode
IDX 10BASE-TX (Transmitter) VDDAT 25 40 mA
IDDC 10BASE-TX (Digital Core + Analog Rx) VDDC, VDDAP 108 180 mA
IDDIO 10BASE-TX (Digital IO) VDDIO 17 20 mA
TTL Inputs
VIH Input High Voltage +2.0 V
VIL Input Low Voltage +0.8 V
IIN Input Current VIN = GND ~ VDDIO –10 10 V
(Excluding Pull-up/Pull-down)
TTL Outputs
VOH Output High Voltage IOH = –8mA +2.4 V
VOL Output Low Voltage IOL = 8mA +0.4 V
|IOZ|Output Tri-State Leakage VIN = GND ~ VDDIO 10 µA
100BASE-TX Transmit (measured differentially after 1:1 transformer)
VOPeak Differential Output Voltage 100 termination on the differential output 0.95 1.05 V
VIMB Output Voltage Imbalance 100 termination on the differential output 2 %
tr, ttRise/Fall Time 35ns
Rise/Fall Time Imbalance 0 0.5 ns
Notes:
1. Exceeding the absolute maximum rating may damage the device.
2. The device is not guaranteed to function outside its operating rating. Unused inputs must always be tied to an appropriate logic voltage level
(ground to VDD).
3. No heat spreader in package.
4. Specification for packaged product only.
5. Measurements were taken within operating ratings.
KS8995MA Micrel, Inc.
M9999-051305 64 May 2005
Symbol Parameter Condition Min Typ Max Units
100BASE-TX Transmit (measured differentially after 1:1 transformer)
Duty Cycle Distortion ±0.5 ns
Overshoot 5%
VSET Reference Voltage of ISET 0.5 V
Output Jitters Peak-to-peak 0.7 1.4 ns
10BASE-TX Receive
VSQ Squelch Threshold 5MHz square wave 400 mV
10BASE-T Transmit (measured differentially after 1:1 transformer) VDDAT = 2.5V
VPPeak Differential Output Voltage 100 termination on the differential output 2.3 V
Jitters Added 100 termination on the differential output 16 ns
Rise/Fall Times 28 30 ns
May 2005 65 M9999-051305
KS8995MA Micrel, Inc.
Timing Diagrams
SCL
SDA
tcyc1ts1 th1
Receive Timing
Figure 12. EEPROM Interface Input Receive Timing Diagram
SCL
SDA
tcyc1
Tr a n s m it Timing
tov1
Figure 13. EEPROM Interface Output Transmit Timing Diagram
Symbol Parameter Min Typ Max Units
tCYC1 Clock Cycle 16384 ns
tS1 Set-Up Time 20 ns
tH1 Hold Time 20 ns
tOV1 Output Valid 4096 4112 4128 ns
Table 17. EEPROM Timing Parameters
KS8995MA Micrel, Inc.
M9999-051305 66 May 2005
tcyc2ts2 th2
MTXC
MTXEN
MTXD[0]
Receive Timing
Figure 14. SNI Input Timing
MRXC
MRXDV
tcyc2
Tr a nsmit Timing
tov2
MRXD[0]
MCOL
Figure 15. SNI Output Timing
Symbol Parameter Min Typ Max Units
tCYC2 Clock Cycle 100 ns
tS2 Set-Up Time 10 ns
tH2 Hold Time 0ns
tO2 Output Valid 036ns
Table 18. SNI Timing Parameters
May 2005 67 M9999-051305
KS8995MA Micrel, Inc.
MRXCLK
MTXEN
MTXER
MTXD[3:0]
tcyc3ts3 th3
Receive Timing
Figure 16. MAC Mode MII Timing Data Received from MII
MTXCLK
MRXDV
MRXD[3:0]
tcyc3
Tr a nsmit Timing
tov3
Figure 17. MAC Mode MII Timing Data Transmitted from MII
Symbol Parameter Min Typ Max Units
tCYC3 Clock Cycle (100BASE-T) 40 ns
tCYC3 Clock Cycle (10BASE-T) 400 ns
tS3 Set-Up Time 10 ns
tH3 Hold Time 5ns
tOV3 Output Valid 71116ns
Table 19. MAC Mode MII Timing Parameters
KS8995MA Micrel, Inc.
M9999-051305 68 May 2005
MTXCLK
MTXEN
MTXER
MTXD[3:0]
tcyc4ts4 th4
Receive Timing
Figure 18. PHY Mode MII Timing Data Received from MII
MRXCLK
MRXDV
MRXD[3:0]
tcyc4
Transmit Timing
tov4
Figure 19. PHY Mode MII Timing Data Transmitted from MII
Symbol Parameter Min Typ Max Units
tCYC4 Clock Cycle (100BASE-T) 40 ns
tCYC4 Clock Cycle (10BASE-T) 400 ns
tS4 Set-Up Time 10 ns
tH4 Hold Time 0ns
tOV4 Output Valid 18 25 28 ns
Table 20. PHY Mode MII Timing Parameters
May 2005 69 M9999-051305
KS8995MA Micrel, Inc.
SPIQ
SPIC
SPID
SPIS_N
High Impedance
MSB
tCHSL tSLCH
tDVCH
tCHDX
tDLDH
tDHDL
LSB
tCLCH
tCHCL
tSHCH
tCHSH
tSHSL
Figure 20. SPI Input Timing
Symbol Parameter Min Typ Max Units
fCClock Frequency 5MHz
tCHSL SPIS_N Inactive Hold Time 90 ns
tSLCH SPIS_N Active Set-Up Time 90 ns
tCHSH SPIS_N Active Hold Time 90 ns
tSHCH SPIS_N Inactive Set-Up Time 90 ns
tSHSL SPIS_N Deselect Time 100 ns
tDVCH Data Input Set-Up Time 20 ns
tCHDX Data Input Hold Time 30 ns
tCLCH Clock Rise Time 1µs
tCHCL Clock Fall Time 1µs
tDLDH Data Input Rise Time 1µs
tDHDL Data Input Fall Time 1µs
Table 21. SPI Input Timing Parameters
KS8995MA Micrel, Inc.
M9999-051305 70 May 2005
SPID
SPIC
SPIQ
SPIS_N
tQLQH
tQHQL
LSB
tCH
tCL tSHQZtCLQV
tCLQX
Figure 21. SPI Output Timing
Symbol Parameter Min Typ Max Units
fCClock Frequency 5MHz
tCLQX SPIQ Hold Time 00ns
tCLQV Clock Low to SPIQ Valid 60 ns
tCH Clock High Time 90 ns
tCL Clock Low Time 90 ns
tQLQH SPIQ Rise Time 50 ns
tQHQL SPIQ Fall Time 50 ns
tSHQZ SPIQ Disable Time 100 ns
Table 22. SPI Output Timing Parameters
May 2005 71 M9999-051305
KS8995MA Micrel, Inc.
tsr
tcs tch
trc
Supply
Voltage
RST_N
Strap-In
Value
Strap-In /
Output Pin
Figure 22. Reset Timing
Symbol Parameter Min Typ Max Units
tSR Stable Supply Voltages to Reset High 10 ms
tCS Configuration Set-Up Time 50 ns
tCH Configuration Hold Time 50 ns
tRC Reset to Strap-In Pin Output 50 ns
Table 23. Reset Timing Parameters
Reset Circuit Diagram
Micrel recommendeds the following discrete reset circuit as shown in Figure 23 when powering up the KS8895MA device. For
the application where the reset circuit signal comes from another device (e.g., CPU, FPGA, etc), we recommend the reset circuit
as shown in Figure 24.
VCC
R
10k
D2
C
10µF
D1 CPU/FPGA
RST_OUT_n
KS8995MA
RST
D1, D2: 1N4148
Figure 23. Recommended Reset Circuit.
VCC
R
10k
C
10µF
D1
KS8995MA
RST
D1: 1N4148
Figure 24. Recommended Circuit for Interfacing with CPU/FPGA Reset
At power-on-reset, R, C, and D1 provide the necessary ramp rise time to reset the Micrel device. The reset out from CPU/FPGA
provides warm reset after power up. It is also recommended to power up the VDD core voltage earlier than VDDIO voltage.
At worst case, the both VDD core and VDDIO voltages should come up at the same time.
KS8995MA Micrel, Inc.
M9999-051305 72 May 2005
Selection of Isolation Transformer(1)
One simple 1:1 isolation transformer is needed at the line interface. An isolation transformer with integrated common-mode
choke is recommended for exceeding FCC requirements. The following table gives recommended transformer characteristics.
Characteristics Name Value Test Condition
Turns Ratio 1 CT : 1 CT
Open-Circuit Inductance (min.) 350µH100mV, 100kHz, 8mA
Leakage Inductance (max.) 0.4µH1MHz (min.)
Inter-Winding Capacitance (max.) 12pF
D.C. Resistance (max.) 0.9
Insertion Loss (max.) 1.0dB 0MHz to 65MHz
Hipot (min.) 1500Vrms
Note:
1. The IEEE 802.3u standard for 100BASE-TX assumes a transformer loss of 0.5dB. For the transmit line transformer, insertion loss of up to 1.3dB
can be compensated by increasing the line drive current by means of reducing the ISET resistor value.
The following transformer vendors provide compatible magnetic parts for Micrel’s device:
4-Port IntegratedAuto Number Single Port AutoNumber
Vendor Part MDI-X of Port Vendor Part MDI-X of Port
Pulse H1164 Yes 4 Pulse H1102 Yes 1
Bel Fuse 558-5999-Q9 Yes 4 Bel Fuse S558-5999-U7 Yes 1
YCL PH406466 Yes 4 YCL PT163020 Yes 1
Transpower HB826-2 Yes 4 Transpower HB726 Yes 1
Delta LF8731 Yes 4 Delta LF8505 Yes 1
LanKom SQ-H48W Yes 4 LanKom LF-H41S Yes 1
Table 24. Qualified Magnetics Vendors
May 2005 73 M9999-051305
KS8995MA Micrel, Inc.
Package Information
128-Pin PQFP (PQ)
MICREL INC. 2180 FORTUNE DRIVE SAN JOSE, CA 95131 USA
TEL + 1 (408) 944-0800 FAX + 1 (408) 474-1000 WEB http://www.micrel.com
This information furnished by Micrel in this data sheet is believed to be accurate and reliable. However no responsibility is assumed by Micrel for its use.
Micrel reserves the right to change circuitry and specifications at any time without notification to the customer.
Micrel Products are not designed or authorized for use as components in life support appliances, devices or systems where malfunction of a product can
reasonably be expected to result in personal injury. Life support devices or systems are devices or systems that (a) are intended for surgical implant into
the body or (b) support or sustain life, and whose failure to perform can be reasonably expected to result in a significant injury to the user. A Purchaser’s
use or sale of Micrel Products for use in life support appliances, devices or systems is a Purchaser’s own risk and Purchaser agrees to fully indemnify
Micrel for any damages resulting from such use or sale.
© 2003 Micrel, Incorporated.