Approval sheet
Page 6 of 8 ASC_WA06Y_V08 Jul.2010
REQUIREMENT
TEST PROCEDURE Resistor Jumper
DC resistance
Clause 4.5
DC resistance values measured at the test voltages
specified below :
<10Ω@0.1V, <100Ω@0.3V, <1KΩ@1.0V,
<10KΩ@3V, <100KΩ@10V, <1MΩ@25V,
<10MΩ@30V
Within the specified
tolerance < 50mΩ
Temperature
Coefficient of
Resistance(T.C.R)
Clause 4.8
Natural resistance change per change in degree
centigrade.
( )
6
121
12 10×
−
ttR RR
(ppm/°C) t
1
: 20°C+5°C-1°C
R
1
: Resistance at reference temperature
R
2
: Resistance at test temperature
Refer to
“QUICK REFERENCE DATA”
N/a
Short time overload
(S.T.O.L)
Clause 4.13
Permanent resistance change after a 5second
application of a voltage 2.5 times RCWV or the
maximum overload voltage specified in the above list,
whichever is less.
∆R/R max. ±(2%+0.10Ω) < 50mΩ
Resistance to
soldering
heat(R.S.H)
Clause 4.18
Un-mounted chips completely immersed for
10±1second in a SAC solder bath at 260℃±5ºC no visible damage
∆ R/R max. ±(1.0%+0.05Ω)
no visible
damage,
< 50mΩ
Solderability
Clause 4.17
Un-mounted chips completely immersed for
2±0.5second in a SAC solder bath at 235℃±5℃ good tinning (>95% covered)
no visible damage
Temperature cycling
Clause 4.19
30 minutes at -55°C±3°C, 2~3 minutes at 20°C+5°C-
1°C, 30 minutes at +155°C±3°C, 2~3 minutes at
20°C+5°C-1°C, total 5 continuous cycles
no visible damage
∆R/R max. ±(1%+0.05Ω)
no visible
damage,
< 50mΩ
Load life (endurance)
Clause 4.25 1000 +48/-0 hours, loaded with RCWV or Vmax in
chamber controller 70±2ºC, 1.5 hours on and 0.5
hours off
10Ω~1MΩ ±(3%+0.1Ω)
<10Ω ±(5%+0.1Ω)
< 50mΩ
Load life in Humidity
Clause 4.24 1000 +48/-0 hours, loaded with RCWV or Vmax in
humidity chamber controller at 40°C±2°
relative humidity, 1.5hours on and 0.5 hours off
10Ω~1MΩ ±(3%+0.1Ω)
<10Ω ±(5%+0.1Ω)
< 50mΩ
Adhesion Clause
4.32 Pressurizing force: 5N, Test time: 10±1sec. No remarkable damage or removal of the
terminations
Insulation Resistance
Clause 4.6
Apply the maximum overload voltage (DC) for
1minute R≧10GΩ
Dielectric Withstand
Voltage
Clause 4.7
Apply the maximum overload voltage (AC) for 1
minute No breakdown or flashover