LARGE CAPACITANCE ALUMINUM ELECTROLYTIC CAPACITORS
@350 to 550Vdc
@Load life with ripple current : 85C 2000 hours
Inverter-use screw terminal 85C
?SPECIFICATIONS
(at 20C, 120Hz)
(at 20C after 5 minutes)
(at 20C, 120Hz)
(at 120Hz)
Operating
Temperature Range
Rated Voltage Range
Capacitance Tolerance
Leakage Current
Dissipation Factor
(tane)
Low Temperature
Characteristics
Insulation Resistance
Insulation
Withstanding Voltage
Load Life
Shelf Life
Items
-
25 to +85C
350 to 550V
dc
P20% (M)
I=0.02CV or 5mA, whichever is smaller.
Where, I : Max. leakage current (MA), C : Nominal capacitance (MF), V : Rated voltage (V)
0.25 max.
Capacitance change Rated Voltage (V
dc
) 350 to 450V 500 & 550V
C(
-
25C)/C(+20C) 0.7min. 0.6min.
When measured between the terminals shorted each other and the mounting clamp on the insulating sleeve covering the case by using
an insulation resistance meter of 500Vdc, the insulation resistance shall not be less than 100MO.
When a voltage of 2000Vac is applied for 1 minute between the terminals shorted each other and the mounting clamp on the insulating
sleeve covering the case, there shall not be electrical damage.
The following specifications shall be satisfied when the capacitors are restored to 20C after subjected to DC voltage with the maximum
ripple current is applied for 2000 hours at 85C.
Capacitance change [P20% of the initial value
DF (tanE)[300% of the initial specified value
Leakage current [The initial specified value
The following specifications shall be satisfied when the capacitors are restored to 20C after exposing them for 500 hours at 85C
without voltage applied.
Capacitance change [P20% of the initial value
DF (tanE)[300% of the initial specified value
Leakage current [The initial specified value
Characteristics
?PART NUMBERING SYSTEM
RWE 550 LG 820 M C C13
Case code
Type of mounting clamp, if required
Cap tolerance (P20%)
Nominal cap in MF
Screw terminal type
Rated voltage in volts
Series name
?DIMENSIONS (Terminal type=LG) [mm]
@B type of mounting clamp
* The screw and the mounting clamp are separately supplied and not attached to the product.
L+4max. GP1
Sleeve
FD+1.8max.
FP1
6
AP1
WP1
H
BP1
30°P5°
360°
3
45°P5°
8
J
KP1
EP1
4.5
@C type of mounting clamp
fD
35
50
63.5
76
A
58
78
90
104.5
B
44
64
76
90
W
48
68
80
93.5
H
3.5
4.5
4.5
4.5
F
12.7
22.4
28.0
31.5
fD
50
63.5
76
89
E
32.5
38.1
44.5
50.8
K
37.0
43.5
50.0
56.5
F
22.4
28.0
31.5
31.5
J
14.0
14.0
14.0
16.0
<Screw specifications>
Plus hexagon-headed screw:
M5B0.8B10
Maximum screw tightening torque:
3.23Nm
F35 to F63.5 : G=6
F76 & F89 : G=5
longer life
RWF
RWE
LARGE CAPACITANCE ALUMINUM ELECTROLYTIC CAPACITORS
Inverter-use screw terminal 85C
100
120
180
270
330
390
470
560
680
820
1,000
1,200
1,500
1,800
2,200
2,700
3,300
3,900
4,700
5,600
6,800
8,200
10,000
12,000
350 400 450 500 550
Case code
Ripple current (Arms) at 85C, 120Hz
mFVdc
A5
A8
A10
A12
C7
C9
D11
E11
E13
E15
F15
C13
D13
D9
E9
1.9
2.9
3.8
4.2
4.7
6.3
10.3
12.6
15.9
19.0
22.5
A5
A8
A10
A12
C7
C9
C13
D9
D11
E11
E13
E15
F15
1.7
2.7
3.4
3.9
4.2
5.7
7.2
7.9
9.5
12.6
14.5
17.3
20.5
8.8
12.0
8.8
11.7
D13 E9 10.9 10.6
A5
A8
A10
A12
C7
C9
C11
C13
D9
D11
E11
E13
E15
F15
1.6
2.4
3.1
3.5
3.9
4.7
5.6
6.5
7.2
8.6
11.5
13.3
15.7
18.6
A5
A8
A10
A12
C7
C9
C11
D13
E11
E15
F15
0.7
1.2
1.4
1.7
1.8
2.5
2.9
5.2
6.1
7.7
10.1
D13 E9 10.0 9.8
C13
D11
D9
E9
3.4
4.5
3.4
4.6
A5
A8
A10
A12
C7
E9
E11
E13
E15
F15
0.6
1.0
1.3
1.6
1.7
4.2
5.0
5.8
7.0
9.3
C9
C11
C13
D9
D11
D13
2.1
2.7
3.1
2.5
3.0
3.5
?STANDARD RATINGS
?RIPPLE CURRENT MULTIPLIERS
@Frequency Multipliers
Frequency (Hz)
Coefficient
50
0.8 120
1300
1.1 1k
1.3 3k
1.4
fD (mm) L (mm)
35
50
63.5
76
89
50
A5
-
-
-
-
80
A8
-
-
-
-
100
A10
-
-
-
-
120
A12
-
-
-
-
75
-
C7
-
-
-
96
-
C9
D9
E9
-
115
-
C11
D11
E11
-
130
-
C13
D13
E13
-
155
-
-
-
E15
F15
?CASE CODE
Note : The lifetime of capacitors is shorted with internal heating produced by ripple currents at the rate of halving the lifetime with every 5 to 10 C
rise. When long life performance is required in actual use, the rms ripple current has to be reduced. Also, for the RWE series capacitors,
using them at operating voltage less than their rated voltage can extend their lifetime. For the details, please contact a representative of
Nippon Chemi-Con.