ORDER FORMAT TERMINAL FUNCTION ROCKER BODY BODY ROCKER LEGEND &
CODE CODE CODE CODE COLOR COLOR OPTIONS
H 8800 V A B B 133W
BBLACK BBLACK
WWHITE WWHITE
8
Phone: 760-343-3650
Arcolectric E
mail: americas@elektron-technology.com
rocker
switches
10
8800/8800
V
Curved
Switches are ON when pressed over terminal 1
8800 Thinline Rocker Switches 10A 250Vac
ROCKERFUNCTION
ON - OFF
Single pole
TERMINAL
8800
ON - OFF
Twin (Single pole)
Switches are ON when pressed over terminals 1 or 3
H
4.8 x 0.8
T
3.5 x 0.8
Solder
X
0.8Sq
Solder *
10(6)A 250Vac T100
6(2)A 250Vac T100 5E4 (50,000 Operations)
Inrush 50A to EN60065:1998
UL CSA 15A 250Vac (Twin unit is 10A 250Vac)
UL CSA 125Vac 1/2hp
UL 100˚C, file E45221, CSA file LR10990
RoHS compliant
3mm contact gap.
Technical data on pages 4 & 5.
9.7
2.6
8.8
1.5
1
1a
3
4
1
2
Ultra thin rocker switch
Ratings up to 15A,
250Vac
Single and twin gang
Panel cut out:
Single 19.3 x 6.8
Twin 19.3 x 13.4
RoHS
7.5
4.0
*Available for single switch only, not twin
CAT 170 P10-17 88-85-12-86_2_11-0328:CAT 170 P10-17 88/85/12/86 20/5/11 13:15 Page 10
Finish
Matt finish only
Color
Call factory for custom colors.
A full range is available for large orders
Legend printing
Select from the examples or call the
factory for custom legends
9
8800 8800VA (H terminals shown)
132(W) 133(W)
H8800VA
T8800VA
H8800 8800VA
T8800 8800VA
Examples of our range of legend printing
( ) is legend color B-Black, W-White, R-Red
H8800VA
T8800VA
H8800 8800VA
T8800 8800VA
Phone: 760-343-3650
Arcolectric E
mail: americas@elektron-technology.com
rocker
switches
11
6.3
5.0
9.7
2.0
9.0
14.5
5.0
9.7
2.0
9.0
14.5
BODY
A Single pole
Panel cut-out Bezel
A Single pole - Twin
Panel cut-out Bezel
Panel thickness Dim X
0.75-1.24 19.1/19.2
1.25-1.99 19.3/19.4
2.00-3.00 19.7/19.8
Dimensions (mm)
8800VA (H terminals shown)
OPTIONS
Cut-outs must be punched in the direction of insertion
21.0
9.5
6.2
6.3
6.8
6.9
17.4
17.5
X
*
*
*Optional profile for orientation
*Optional profile for orientation
21.0
15.5
9.9
10.0
X
13.4/
13.5
17.4
17.5
*
*
X8800VA ---
CAT 170 P10-17 88-85-12-86_2_11-0328:CAT 170 P10-17 88/85/12/86 20/5/11 13:15 Page 11
10
ORDER FORMAT TERMINAL FUNCTION ROCKER BODY BODY ROCKER LAMP VOLTAGE LEGEND &
CODE CODE CODE CODE COLOR COLOR OR ON LIGHT” OPTIONS
H 8553 V B B R 2 551W
NON-LIT LIT
BBLACK BBLACK AAMBER ‘X’ ROCKER COLOR R,G,W,B
RRED RRED CCLEAR 2125V NEON
WWHITE WWHITE GGREEN 3250V NEON
RRED 712V INCANDESCENT
Phone: 760-343-3650
Arcolectric E
mail: americas@elektron-technology.com
rocker
switches
12
HSlotted for custom caps
RSemi-rotary (not lit)
DPaddle lever (not lit)
VCurved (not lit)
VCurved (lit)
XTwo colour (not lit)
ASoftline lens
PPush button operation
(8500 only)
See drawing opposite
ON OFF Switches are ON when pressed over terminal 1
8550
8503
8500 Rocker Switches - Miniature 10A 250Vac Single & Double Pole
ROCKERFUNCTION
Approvals &
ratings vary
with function
ON - OFF
Single pole
(Uses terminals 1a & 2a)
ON (lit) - OFF
Double pole
Indicator
ON (lit) - OFF
Single pole
ON - OFF
Double pole
TERMINAL
8553
8500
8580
Available with
H terminals only
H
4.8 x 0.8
K
2.8 x 0.8
L
2.8 x 0.8
Right angle version of K terminal
available on 8500 only
R
4.8 x 0.8
T
Solder
8.5
4.5
1.5
3.1
10(6)A 250Vac T125 (non lit types)
6(4)A 250Vac T125 5E4 (50,000 Operations) (non lit types)
10(6)A 250Vac T100 (lit types)
UL CSA 15A Non Ind 250Vac, 14A Ind 250Vac, 10A 277Vac
UL CSA 250Vac 1/2hp, 125Vac 1/4hp
UL 105˚C, (non lit) file E45221, CSA file LR10990
RoHS compliant
3mm contact gap.
Technical data on pages 4 & 5 (switches), 6 (indicators).
1a
3b
2a
4b
8.5
2.6
1.5
3.2
2.6
8.5
3.5
R1.0
R0.8
Miniature rocker switch
Ratings up to 15A,
250Vac
Single & double pole in
same body size
Illuminated & non-
illuminated
Matching indicators
Industry standard panel
cut-out
Rotary and push button
actuator options
Panel cut out: 19.3 x 12.9
RoHS
CAT 170 P10-17 88-85-12-86_2_11-0328:CAT 170 P10-17 88/85/12/86 20/5/11 13:16 Page 12
11
Finish
Matt finish only
Color
Call factory for custom colors
A full range is available for large orders
Legend printing
Select from the examples or call the
factory for custom legends
Lamp voltage
Call factory for details of other
available voltages
Protective cover L167
(designed to IP65)
Snaps on to bodies with V or X style
rockers and A lens but reduces panel
thickness by 0.8mm
551(W) 080(W)
Examples of our range of legend printing
( ) is legend color B-Black, W-White, R-Red
H8550XB ---
T8550XB ---T8550HB ---
H8550HB ---H8500VB ---
T8500VB ---
H8550VB ---
T8550VB ---
H8553VB ---
T8553VB ---
H8580AB ---
H8550RB Semi-rotary
A splash proofing option
H8500PO ---
Pushbutton option
Phone: 760-343-3650
Arcolectric E
mail: americas@elektron-technology.com
rocker
switches
13
BODY
B
Standard body with terminal barrier
Panel cut-out Bezel
BC
Body without terminal barrier
Panel cut-out Bezel
Dimensions for snap-in fixing
Panel
thickness Dim X
0.75-1.25 19.1/19.2
1.25-2.00 19.3/19.4
2.00-3.00 19.7/19.8
DIMENSIONS (mm)
5.1
22.5
9.0
2.0
9.0
14.0
6.0
9.5
OPTIONS
21.0
15.0
X
12.9
21.0
15.0
X
12.9
“B” body with barrier for
H, T and K terminals
5.1
16.0
4.5
2.0
9.0
14.0
“BC” body w/o barrier primarily
for L or R terminals
(can be used for all terminals)
Cut-outs must be punched in the direction of insertion
23.2
max
20.5
max
1
12.7 9.5
18.0
23.3
5.0
8.0
12.0
‘PO’ Actuator and body - push button function (8500 only)
CAT 170 P10-17 88-85-12-86_2_11-0328:CAT 170 P10-17 88/85/12/86 20/5/11 13:16 Page 13
12
ORDER FORMAT TERMINAL FUNCTION ROCKER BODY BODY ROCKER LAMP VOLTAGE LEGEND &
CODE CODE CODE CODE COLOR COLOR (if required) OPTIONS
H 8653 V B B R 2 551W
NON-LIT LIT
BBLACK BBLACK AAMBER 2125V NEON
RRED RRED CCLEAR 3250V NEON
WWHITE WWHITE GGREEN 712V INCANDESCENT
RRED
Miniature rocker switch
Ratings up to 16A,
250Vac
Single & double pole
Single throw or double
throw
Momentary Options
187 TAB, solder and PCB
terminals
Illuminated and non-
illuminated
Matching indicators
Panel cut out
single: 19.3 x 12.9
double: 19.3 x 21.9
Phone: 760-343-3650
Arcolectric E
mail: americas@elektron-technology.com
rocker
switches
14
VCurved
VCurved (lit)
DPaddle lever
(Single pole non-lit only)
HSlotted for actuator
(8600 and 8610 only)
FFlat
Indicator only (Single pole)
8600 Rocker Switches - Miniature 10A 250Vac Single & Double Pole
ROCKERFUNCTION
Approvals &
ratings vary
with function
ON OFF Switches
are ON when pressed
over terminal 3
ON - OFF
8600
10(4)A
16A 250V, 10A 277V
1/2HP 277V,1/4HP 125V
8650
10(4)A
10A 277V
1/2HP 277V,1/4HP 125V
ON - OFF
(momentary ON)
8601
6(1)A
16A 250V, 6A 277V
8651
6(1)A
6A 277V
ON - OFF
(momentary OFF)
8602
10A
16A 250V, 10A 277V
8652
10(4)A
6A 277V
ON - OFF
Lit
N/A 8653
10(4)A
6A 277V
ON - ON
8610
6(1)A
10A 277V
1/2HP 277V,1/4HP 125V
8660
6(1)A
10A 277V, 1/2HP 277V
1/2HP 277V,1/4HP 125V
ON - ON
(momentary 1 side)
8611
6A 277V
8661
6A 277V
ON - OFF - ON
8620 µ
See page 16
8670 µ
See page 16
Indicator
8630
TERMINAL
H
4.8 x 0.8
T
3.5 x 0.8
Solder
X
PCB
0.8 Sq
Double Pole switches with “X”
terminals are supplied without
terminal barriers
7.4
10(4)A 250Vac T90 (unless noted below)
UL CSA See ratings below
UL 65˚C, file E45221, CSA file LR10990
Inrush 50A to EN61058-1 & 10A 24Vdc
RoHS compliant
3mm contact gap except where marked µ.
Technical data on pages 4 & 5 (switches), 6 (indicators).
6.4
O/ 2.2
5.3
3.7
2
13
2
13
5
46
In house test
RoHS
CAT 170 P10-17 88-85-12-86_2_11-0328:CAT 170 P10-17 88/85/12/86 20/5/11 13:17 Page 14
13
142(W) 059(W) 058(W)
H8600VB
T8600VB
H8600VB
T8600VB
H8660VB
T8660VB
H8630FB
T8630FB
H8653VB
T8653VB
H8650VB
T8650VB
Finish
Matt finish only
Color
Call factory for custom colors
A full range is available for large orders
Legend printing
Select from the examples or call the
factory for custom legends
Lamp voltage
Call factory for details of other
available voltages
Hole Plug 8630FBBB Black Standard
Dummy unit to fill unused panel holes
Single pole size only
White available contact factory
Protective covers
L167 for SP
L180 for DP
(designed to IP65)
Snap on to bodies with V rocker or F lens but
reduce panel thickness by 0.8mm.
Not for use with momentary types
Single Pole options
Most switches shown can have single
pole switching in double pole bodies
577(W) 080(W) 141(W)
Examples of our range of legend printing
( ) is legend color B-Black, W-White, R-Red
Phone: 760-343-3650
Arcolectric E
mail: americas@elektron-technology.com
rocker
switches
15
BODY
BSingle pole
Panel cut-out Bezel
Single Pole dimensions for snap-in fixing
Panel thickness Dimension X
0.75-1.24 19.1/19.2
1.25-1.99 19.3/19.4
2.00-3.00 19.7/19.8
B(Double Pole) with terminal barrier
BC (Double Pole) w/o terminal barrier
Panel cut-out Bezel
Double Pole dimensions for snap-in fixing
Panel thickness Dimension X
0.75-1.24 19.1/19.2
1.25-1.99 19.3/19.4
2.00-3.00 19.7/19.8
DIMENSIONS (mm)
Single pole Double pole
5.8
12.5
2.0 7.4
7.0
7.0
OPTIONS
21.0
15.0
X
12.9
21.0
24.0
X
21.9
Terminals shown
are “H” 4.8 push on type
For 8620 and 8670 dimensions see page 16
5.8
19.8
to barrier
2.0
12.5
T
7.0
7.0
Terminal spacing
10.2 between pole centres
Cut-outs must be punched in the direction of insertion
CAT 170 P10-17 88-85-12-86_2_11-0328:CAT 170 P10-17 88/85/12/86 20/5/11 13:18 Page 15
ORDER FORMAT TERMINAL FUNCTION ROCKER BODY BODY ROCKER LEGEND &
CODE CODE CODE CODE COLOR COLOR OPTIONS
H 8620 V B B B 141W
BBLACK BBLACK
WWHITE WWHITE
3 position miniature
rocker switch
Ratings up to 15A,
250Vac
Single & double pole
Center off switching
187 TAB, solder and PCB
terminals
Matching indicators
Panel cut out:
single: 19.3 x 12.9
double: 19.3 x 21.9
Finish
Matt finish only.
Color
Call factory for custom
colors.
A full range is available for
large orders.
Legend printing
Select from the examples
or call factory for custom
legends.
Protective covers
IP65
L167 for SP
L180 for DP
(designed to IP65)
Snaps on to body, this
reduces maximum
acceptable panel thickness
to 2.2mm.
Phone: 760-343-3650
Arcolectric E
mail: americas@elektron-technology.com
rocker
switches
16
8620 & 8670 Rocker Switches - 3 Positions 10A 250Vac
OPTIONSFUNCTION
VCurved
HSlotted for actuator
(8620 only)
BSingle pole
Panel thickness Dim X
0.75-1.24 19.1/19.2
1.25-1.99 19.3/19.4
2.00-3.00 19.7/19.8
BDouble pole
Panel thickness Dim X
0.75-1.24 19.1/19.2
1.25-1.99 19.3/19.4
2.00-3.00 19.7/19.8
8620
ON - OFF - ON
Single pole
ROCKER BODYTERMINAL
H
4.8 x 0.8
T
Solder
X
PCB 0.8sq
Double pole switches with X
terminals are supplied without
terminal barriers
8.5
10(4)A 250Vac T90
UL CSA 15A 277Vac (Single pole)
UL CSA 250Vac 1/2hp (Single pole)
UL CSA 125Vac 1/4hp (Single pole)
UL CSA 10A 277Vac (Double pole)
UL CSA 277Vac 1/2hp (Single & Double pole)
UL 90˚C, file E45221, CSA file LR10990
RoHS compliant
µ contact gap.
Technical data on pages 4 & 5.
6.4
O/ 2.15
8.0
4.0
Dimensions (mm)
8620VB (H terminals shown) 8670VB (H terminals shown) 8670VB (X terminals shown)
8670
ON - OFF - ON
Double pole
213
5b
4b 6b
2a1a3a
15.0
2.0
8.5
7.0
Ctrs
14.0
X
12.9
21.0
15.0
21.0
24.0
X
21.9
15.0
2.0
8.9
7.0
Ctrs
14.0
10.2
Ctrs
15.0
2.0
8.0
7.0
Ctrs
14.0
10.2
Ctrs
Cut-outs must be punched in the direction of insertion
RoHS
H8620VB ---
T8620VB ---
H8670VB ---
T8670VB ---
CAT 170 P10-17 88-85-12-86_2_11-0328:CAT 170 P10-17 88/85/12/86 20/5/11 13:19 Page 16
ORDER FORMAT TERMINAL FUNCTION ROCKER BODY BODY ROCKER LEGEND &
CODE CODE CODE CODE COLOR COLOR OPTIONS
C 1250 A P B B 085W
BBLACK BBLACK
WWHITE WWHITE
GGREY
Finish
Matt finish only.
Color
Call factory
for custom colors.
A full range is available for
large orders.
Legend printing
Select from the
examples or call factory for
custom legends.
Contact factory for
suggested terminals.
Phone: 760-343-3650
Arcolectric E
mail: americas@elektron-technology.com
rocker
switches
17
1250 Rocker Switches 10A 250Vac
OPTIONSFUNCTION
On when pressed over terminal 1
ACurved
Shown in N body
Shown in P body
N
Panel thickness Dim X
0.75-1.24 26.1/26.2
1.25-1.99 26.3/26.4
2.00-3.00 26.7/26.8
P
Panel thickness
0.75-3.00
1250
ON - OFF
Double pole
Poles are 9.0mm
between centres.
ROCKER BODYTERMINAL
C
6.3 x 0.8
X
PCB 0.8sq
(N body only)
9.0
10(6)A 250Vac T100
6A 400Vac T100
1A 30Vdc
UL CSA 10A 250Vac
UL CSA 16A 250Vac Resistive
UL CSA 125Vac 1/2hp
UL CSA 1A 30Vdc
UL 100˚C, file E45221, CSA file LR10990
Inrush 75A to EN61058-1
RoHS compliant
3mm contact gap
Technical data on pages 4 & 5
9.0
5.2
Dimensions (mm)
1250AN (C terminals shown) 1250AN (X terminals shown) 1250AP (C terminals shown) Connector Housing F1344
2a
1a
2
1
1250SP
ON - OFF
Single pole
1a 1
1
2
1
2a
1a
On when pressed over terminal 1
11a
11.0 21.0
Sub-panelFacia
10.6
9.8
4.0
6.0 26.0
Panel
10.6
9.8
4.0
11.0 17.0
Sub-panelFacia
10.6
4.0 3.2
29.5
15.0
29.5
13.0
4
13.1
nom
23.8
nom
R3.5
12.4/
12.5
X
12.4/
12.5
27.2/
27.3
Panel cut-out Bezel
Panel cut-out Bezel
Sub-panel Facia
Cut-outs must be punched in the direction of insertion
In house test
Standard rocker switch
Double pole in single
pole body
Snap in or sub panel
mount
Integral terminal barrier
Push on or PCB
terminals
High inrush tolerance
Panel cut out:
27.2 x 12.4 (snap in)
26.3 x 12.4 (sub panel
mount)
RoHS
C1250AP --- C1250AN ---
CAT 170 P10-17 88-85-12-86_2_11-0328:CAT 170 P10-17 88/85/12/86 20/5/11 13:19 Page 17
ORDER FORMAT
16
TERMINAL FUNCTION ROCKER BODY BODY ROCKER LAMP VOLTAGE LEGEND &
CODE CODE CODE CODE COLOR COLOR IF REQUIRED OPTIONS
C 6003 A L B R 2 1197W
NON-LIT LIT
BBLACK BBLACK AAMBER
RRED RRED CCLEAR 2125V NEON
WWHITE WWHITE GGREEN 3250V NEON
RRED 712V INCANDESCENT
Phone: 760-343-3650
Arcolectric E
mail: americas@elektron-technology.com
rocker
switches
18
C
6.3 x 0.8
H
4.8 x 0.8
S
Screw & Clamp
N/A for assemblies
with 3 terminals
European 16(4)A 250Vac T125, 10A 400Vac T125
UL CSA 20A 277Vac, 250Vac 11/2hp, 125Vac 1hp
UL 100˚C, file E45221, CSA file LR10990
Inrush 150A* to EN61058-1 (ON - OFF only)
*applies to non-momentary types
RoHS compliant
3mm contact gap with Positive Break switching.
Call factory for IP details.
Technical data on pages 4 & 5 (switches), 6 (indicators).
ASoftline
Matt
ASoftline
Matt
PLit window
Matt
ALens
Matt (6030 indicator only)
6000 SP Splash Resistant Rocker Switches 16A 250Vac
ROCKERFUNCTION
Approvals & ratings vary with function
ON OFF Switches - ON when pressed over terminal 3
TERMINAL
6000 ON - OFF
9.7
9.7
9.7
12 3
6001 ON - OFF (momentary ON)
6002 ON - OFF (momentary OFF)
6003 ON - OFF Lit
6008 ON - OFF Lit (Unswitched neutral)
6009 ON - OFF (momentary ON) Lit
(Unswitched neutral)
6010 ON - ON
6011 ON - ON (momentary 1 side)
6030 Indicator
For twin switches and double pole circuits see pages 20 & 21
Lit
In house test
Ratings up to 20A,
277Vac
High in-rush (ON-OFF
types)
Positive switch action
Distinctive styling
Illuminated & non-
illuminated
Single pole
Matching indicator
Panel cut out:
30.1 x 11.1mm
RoHS
CAT 170 P18-29 1500-6000_2_11-0328:CAT 170 P18-29 1500/6000 23/5/11 08:40 Page 18
1224(W) 1223(W)
Examples of our range of legend printing
( ) is legend color B-Black, W-White, R-Red
17
Finish Matt is standard
Color Call factory for custom colors.
A full range is available for large orders
Legend printing Select from the examples or
call factory for custom legends
Lamp voltage Call factory for details
Protective cover (designed to IP65 #)
The 6000 series is a water thru design.
For a higher level of sealing, a snap on cover is
available (add suffix G74). This reduces panel
thickness by 1mm.
Panel sealing washer W46 is available but reduces
panel thickness by a further 0.8mm.
Covers are not suitable for momentary types.
For all options call the factory
Phone: 760-343-3650
Arcolectric E
mail: americas@elektron-technology.com
rocker
switches
19
L
Panel cut-out ** Bezel
BODY DIMENSIONS (mm)
OPTIONS
2.0 30.0
10.0
8.0
2A 1A
11.0/11.1
30.0/
30.1
14.0
31.5
R2.0
Panel thickness
L0.75 to 2.5mm
** For cut-out details
on momentary switches
call sales
Cut-outs must be punched in the direction of insertion
Integral Splash Resistance
Current carrying parts are protected from moisture.
Droplets which may enter the switch are channelled out
through ports in the switch body.
For IP65 see options below
C6000AL --- C6000AL ---
C6003PL ---
C6010AL ---
C6030AL ---
C6003AL ---
CAT 170 P18-29 1500-6000_2_11-0328:CAT 170 P18-29 1500/6000 23/5/11 08:40 Page 19
ORDER FORMAT
18
TERMINAL FUNCTION ROCKER BODY BODY ROCKER LAMP VOLTAGE LEGEND &
CODE CODE CODE CODE COLOR COLOR IF REQUIRED OPTIONS
C 6053 A L B R 2 1197W
NON-LIT LIT
BBLACK BBLACK AAMBER
RRED RRED CCLEAR 2125V NEON
WWHITE WWHITE GGREEN 3250V NEON
RRED 712V INCANDESCENT
Phone: 760-343-3650
Arcolectric E
mail: americas@elektron-technology.com
rocker
switches
20
C
6.3 x 0.8
H
4.8 x 0.8
S
Screw & Clamp
N/A for assemblies
with 3 terminals in either pole
ASoftline
Matt
ASoftline
Matt
PLit Window
Matt
6050 DP Splash Resistant Switches - & Twins #16A 250Vac
ROCKERFUNCTION
Approvals & ratings vary with function
ON OFF Switches - ON when pressed over terminals 3 & 6
TERMINAL
6050 ON - OFF
9.7
9.7
9.7
123
45 6
6060 ON - ON
6051 ON - OFF
(momentary ON)
6061 ON - ON
(momentary 1 side)
6062 2 Circuit ON - ON
In house tests only
6052 ON - OFF
(momentary OFF)
6066 ON - ON (Single pole)
Isolated light
6053 ON - OFF
Lit
6067 ON - ON
Lit
ON - OFF
6054 (momentary ON)
Lit
6068 ON - ON 1pole
ON - OFF Lit 1pole
ON - OFF (Single pole)
6055 (momentary ON)
Lit
6090 ON - OFF 1pole
ON - OFF Lit 1pole
6056 ON - OFF (Single pole)
Isolated light
ON - OFF
6091 (momentary ON)
Lit
6057 ON - OFF
Isolated light
ON - OFF 1 pole
6092 ON - ON 1 pole
Lit
6058 ON - OFF (Single pole)
Lit
ON - OFF (Single pole)
6059 (momentary ON)
Isolated light
Circuits are Double Pole
unless described otherwise
European 16(4)A 250Vac T125, 10A 400Vac T125
UL CSA 20A 277Vac, 250Vac 11/2hp, 125Vac 1hp
UL 100˚C, file E45221, CSA file LR10990
Inrush 150A* to EN61058-1
8(8)A 250Vac T125 5E4 on 6050 only
*applies to non-momentary types
RoHS compliant
3mm contact gap with Positive Break switching.
# Call sales for IP details on Twin units.
Technical data on pages 4 & 5 (switches), 6 (indicators).
Patent app.
In house test
Lit Window
Lit
Ratings up to 20A,
277V ac
High in-rush (ON-OFF
types)
Positive switch action
Distinctive styling
Illuminated & non-
illuminated
Double pole
Panel cut out:
30.1 x 22.2mm
RoHS
CAT 170 P18-29 1500-6000_2_11-0328:CAT 170 P18-29 1500/6000 23/5/11 08:41 Page 20
C6003P/6030AL
C6050AL C6053AL C6053PL
1196(W) 1197(W)
Examples of our range of legend printing
( ) is legend color B-Black, W-White, R-Red
19
Finish Matt is standard
Color Call factory for custom colors
A full range is available for large orders
Legend printing Select from the examples or
call factory for custom legends
Lamp voltage Call factory for details
Protective cover (designed to IP65 #)
The 6000 series is a water thru design.
For a higher level of sealing, a snap on cover is
available (add suffix G72). This reduces panel
thickness by 1mm.
Panel sealing washer W42 is available but reduces
panel thickness by a further 1.00mm.
Covers are not suitable for momentary types.
IP Ratings Call the factory for details
Jumper Terminal P1067 connects the poles
of a double pole switch or twin unit
# Mounting orientation may affect IP rating
For all options call the factory
C6003/60003PL
C6000/6000AL
Phone: 760-343-3650
Arcolectric E
mail: americas@elektron-technology.com
rocker
switches
21
LDouble pole
Panel cut-out * Bezel
LTwin units
Contact sales for information on
splash resistance and IP ratings
Panel cut-out * Bezel
BODY DIMENSIONS (mm)
OPTIONS
Panel thickness
L 0.75 to 3.0mm
* For cut-out details on
momentary switches
call sales
Terminal spacing - Poles 10.5 between centres
2.0 30.0
10.0
8.0
5B 4B
22.1/22.2
30.0/
30.1
25.0
31.5
R2.0
22.1/22.2
30.0/
30.1
25.0
31.5
R2.0
For IP65 see options below
Integral Splash Resistance
Current carrying parts are protected from moisture.
Droplets which may enter the switch are channelled out through
ports in the switch body
Cut-outs must be punched in the direction of insertion
CAT 170 P18-29 1500-6000_2_11-0328:CAT 170 P18-29 1500/6000 23/5/11 08:41 Page 21
ASoftline Matt
BSplash resistant (with Arcshield)
HSlotted (for custom Adaptors)
not momentary
VCurved Matt or gloss
WSplash resistant (with Arcshield)
XTwo color Matt
ON - OFF only (not momentary)
FFlat lens Gloss (0430 only)
ASoftline lens Matt (0430 only)
as F but with raised profile
20
ORDER FORMAT TERMINAL FUNCTION ROCKER BODY BODY ROCKER LAMP VOLTAGE LEGEND &
CODE CODE CODE CODE COLOR COLOR OR ON LIGHT” OPTIONS
C 1300 A L B B - 602AW
NON-LIT LIT
BBLACK BBLACK AAMBER X ROCKER COLOR R,G,W,B
RRED RRED CCLEAR 2125V NEON
WWHITE WWHITE GGREEN 3250V NEON
RRED 712V INCANDESCENT
Standard rocker switch
Non-illuminated
1300 high inrush current
Choice of switching
circuits including 3
position
Choice of bezel styles
Choice of 6 panel cut
outs
We match all major
brands
Matching indicator
Single pole
Splash resistant option
Panel cut out A style:
27.3 x 12.3mm
430
X terminal N/A
Phone: 760-343-3650
Arcolectric E
mail: americas@elektron-technology.com
rocker
switches
22
ON - OFF
1500 Standard & 1300 High Inrush Switches 150A to EN61058-1 and 16A 250Vac
ROCKERFUNCTION
Approvals & ratings vary with function
ON OFF Switches - ON when pressed over terminal 1
TERMINAL
Standard
1500
ON - OFF
(momentary ON)
1501
HP rating N/A
C
6.3 x 0.8
H
4.8 x 0.8*
K
2.8 x 0.8*
T
Solder
U
Right angle “T” solder terminal
X
PCB 0.8Sq*
*N/A for 1300 series
9.1
7.0
Ø2.1
1500 Series 16(4)A 250Vac T125
UL CSA 16A Non Ind 250Vac, (2 posn) 250Vac 1hp, 125Vac
1/2hp, (3 posn) 250Vac 1/2hp, 125Vac 1/4hp
UL 10A 14Vdc ‘T’ (1500 and 1510 only)
UL 85˚C, file E45221, CSA file LR10990
10A 24Vdc
1300 series 16(6)A 250Vac T125 5E4 (50,000 Ops.)
150A Inrush to EN61058-1
UL CSA 20A 250Vac 1hp, 125Vac 1/2hp
UL 85˚C, file E45221, CSA file LR10990
20A 24Vdc
RoHS compliant
3mm contact gap except if marked µ.
Technical data on pages 4 & 5 (switches), 6 (indicators).
9.1
9.1
2.0
1.2
3.2
Ø2.1
9.1
4.0
123
ON - OFF
(momentary OFF)
1502
HP rating N/A
ON - ON
1510 µ
HP rating N/A
ON - ON
(momentary 1 side)
1511 µ
HP rating N/A
ON - OFF - ON
1520 µ
125V & 250V 1/2 HP
H terminal rated
T100 only
ON - OFF - ON
(momentary 1 side)
1521 µ
HP rating N/A
H terminal rated
T100 only
ON - OFF - ON
(momentary 2 sides)
1522 µ
HP rating N/A
H terminal rated
T100 only
Indicator
Technical data on page 6
In house test
In house test
Matt
Matt
High Inrush
1300
‘L body only
Approvals apply to C & T
terminals only
RoHS
CAT 170 P18-29 1500-6000_2_11-0328:CAT 170 P18-29 1500/6000 23/5/11 08:41 Page 22
21
C1500AR
T1500AR
C1500AL
T1500AL
C1520AL
T1520AL
C1500XL
T1500XL
C430AL
T430AL
C1510AL
T1520AL
Finish Matt is standard
Color Call factory for custom colors
A full range is available for large orders
Legend printing Select from the examples or
call factory for custom legends
Lamp voltage Call factory for details
Hole Plug 1530BB Dummy units
to fill unused panel holes
Protective cover (designed to IP65)
Snaps on to A, L, Q or T bodies
(add G74 as a suffix).
This reduces panel thickness by 1mm.
Panel sealing washer W46 is available for the
same body sizes but reduces panel thickness by a
further 0.8mm.
Covers are not suitable for momentary types.
For all options call the factory
602A(W) 730(W) 822(W)
Examples of our range of legend printing
( ) is legend color B-Black, W-White, R-Red
Phone: 760-343-3650
Arcolectric E
mail: americas@elektron-technology.com
rocker
switches
23
A
Gloss or Matt
B
Matt only
L
Matt only
Q
Gloss or Matt
R
Matt only
T
Matt only
BODY DIMENSIONS (mm)
Panel cut-out *Bezel
OPTIONS
12.2/12.3
27.2
27.3
11.0/11.1
30.0
30.1
11.5/11.6
28.2
28.3
11.5/11.6
28.2
28.3
14.0/14.1
28.5
28.6
11.0/11.1
30.0
30.1
14.0
30.2
14.0
33.4
R3.5
14.0
32.0
R1.0
14.0
30.2
R1.6
17.0
31.5
14.0
30.2
R1.6
Cut-outs must be punched in the direction of insertion
feather-edge seal
collar
Splash Resistant
1500 W and B splash resistant options
Feather edge seals and a close fitting collar protect current
carrying parts from moisture.
B option has Hytrel collar/seals for enhanced protection.
Panel thickness
A,Q 0.75 to 3.3mm
L,B,T 0.75 to 2.5mm
R 0.75 to 3.0mm
* For cut-out details
on momentary switches
call sales
2.0 25.3 Max
9.2
13.2
7.6
plunger tube
1300 High inrush, positive break switching
The 1300 series mechanism
ensures contact welds formed at
switch-on are positively separated
by the plunger tube acting directly
on the step in the moving contact.
step
CAT 170 P18-29 1500-6000_2_11-0328:CAT 170 P18-29 1500/6000 23/5/11 08:41 Page 23
ORDER FORMAT TERMINAL FUNCTION ROCKER BODY BODY ROCKER LAMP VOLTAGE LEGEND &
CODE CODE CODE CODE COLOR COLOR (if required) OPTIONS
C 5503 A L B R 2 602W
NON-LIT LIT
BBLACK BBLACK AAMBER
RRED RRED CCLEAR 2125V NEON
WWHITE WWHITE GGREEN 3250V NEON
RRED 712V INCANDESCENT
Standard rocker switch
Illuminated
Choice of switching
circuits
Choice of bezel styles
Choice of 6 panel cut
outs
We match all major
brands
Matching indicator
Single pole
Splashproof option
Panel cut out A style:
27.3 x 12.3mm
Phone: 760-343-3650
Arcolectric E
mail: americas@elektron-technology.com
rocker
switches
24
ASoftline (Matt only)
PLit window (Matt only)
ON - OFF
ON - OFF
Lit
Unswitched neutral
5500 Lit Rocker Switches - Single Pole 16A 250Vac
ROCKERFUNCTION
Approvals & ratings vary with function
ON OFF Switches - ON when pressed over terminal 3
TERMINAL
5500 µ
5508 µ
for special
applications
C
6.3 x 0.8
H
4.8 x 0.8
T
Solder
9.1
7.0
Ø2.1
16(4)A 250Vac T85
10(3)A 250Vac T100, (12A 250Vac T125 for P rocker only)
UL CSA 15A 250Vac, CSA 16A Non Ind 250Vac
UL CSA 250Vac 1hp, 125Vac 1/2hp
UL 85˚C, file E45221, CSA file LR10990
Inrush 24A to EN61058-1
RoHS compliant
µ contact gap.
Technical data on pages 4 & 5 (switches), 6 (indicators).
For Twin units repeat the order details for both the left and right sides.
9.1
12 3
ON - OFF
Lit
Switched neutral
5503 µ
preferred option
In house test
Lit
RoHS
CAT 170 P18-29 1500-6000_2_11-0328:CAT 170 P18-29 1500/6000 23/5/11 08:41 Page 24
Finish Matt is standard
Color Call factory for custom colors
A full range is available for large orders
Legend printing Select from the examples or
call factory for custom legends
Lamp voltage Call factory for details
Hole Plugs 1530ABB (SP) 1580ABB (DP)
Dummy units to fill unused panel holes
Protective covers (designed to IP65)
Snap on to A, L, Q or T bodies.
(add G74 suffix for single & G72 for double pole).
This reduces panel thickness by 1mm.
Panel sealing washers W46 (Single Pole) and
W42 (Double Pole) are available for these
body types but reduce panel thickness by a further
1.00mm.
For all options call the factory
C5503AL C5500AL C5503PL
C5503/5503AL C5503/5503PL
C5503/5430AL
602(W) 3064(W) 706(W)
Examples of our range of legend printing
( ) is legend color B-Black, W-White, R-Red
Phone: 760-343-3650
Arcolectric E
mail: americas@elektron-technology.com
rocker
switches
25
APanel cut-outs Bezel
Matt only
B
Matt only
L
Matt only
Q
Matt
R
Matt only
T
Matt only
BODY DIMENSIONS (mm)
OPTIONS
Panel thickness
A,Q 0.75 to 3.3mm
L,B,T 0.75 to 2.5mm
R0.75 to 3.0mm
7.6
2.0 28.6 Max
9.2
13.2
12.2/12.3
27.2
27.3
11.0/11.1
30.0
30.1
11.5/11.6
28.2
28.3
11.5/11.6
28.2
28.3
14.0/14.1
28.5
28.6
11.0/11.1
30.0
30.1
14.0
30.2
14.0
33.4
R3.5
14.0
31.9
R1.0
14.0
30.2
R1.6
17.0
31.5
14.0
30.2
R1.6
Twin units
Two single switches or a switch and an indicator light can be
assembled side by side in one double pole body.
For 5500 range panel cut-out details (L, B and T) call sales.
For twin units the first set of order format details refer to the
left hand unit, when looking at the front of the assembly.
(This has terminal numbers 1, 2 & 3)
1
2
3
4
5
6
1
2
3
4
5
6
Terminal spacing - Poles 10.8 between centres (twin units)
Cut-outs must be punched in the direction of insertion
CAT 170 P18-29 1500-6000_2_11-0328:CAT 170 P18-29 1500/6000 23/5/11 08:41 Page 25
24
ORDER FORMAT TERMINAL FUNCTION ROCKER BODY BODY ROCKER LAMP VOLTAGE LEGEND &
CODE CODE CODE CODE COLOR COLOR OR ON LIGHT” OPTIONS
C 1500/1500 A L B R 2 602AW
NON-LIT LIT*
BBLACK BBLACK AAMBER ‘X’ ROCKER COLOR R,G
RRED RRED CCLEAR 2125V NEON* *Indicator only
WWHITE WWHITE GGREEN 3250V NEON*
RRED 712V INCANDESCENT*
Twin unit rocker switch
Choice of switching
circuits including 3
position
Push-on, solder and
PCB terminals
Choice of bezel styles
Choice of 6 panel cut
outs
We match all major
brands
Matching indicator
Single pole switches
Splashproof option
Panel cut out A style:
27.2 x 22.3mm
430
X terminal N/A
Phone: 760-343-3650
Arcolectric E
mail: americas@elektron-technology.com
rocker
switches
26
16(4)A 250Vac T125
UL CSA 16A 250Vac
UL CSA (2 posn) 250Vac 1hp, 125Vac 1/2hp, (3 posn) 250 Vac
1/2hp, 125Vac 1/4hp
UL 85˚C, file E45221, CSA file LR10990
Inrush 36A to EN61058-1
For versions with High Inrush or for 50,000 operations, see page 20.
RoHS compliant
3mm contact gap except where marked µ.
Technical data on pages 4 & 5 (switches), 6 (indicators).
ON - OFF
ON - ON
ON - OFF - ON
Indicator
Technical data on page 6
ASoftline (Matt)
BSoftline splash resistant (Matt)
WCurved splash resistant (Matt)
XTwo colour (Matt) (not momentary)
ON - OFF only
ASoftline lens (Matt) (Indicator)
1500 Twin Units Switches and Indicators 16A 250Vac
ROCKERFUNCTION
Approvals & ratings vary with function
ON OFF Switches - ON when pressed over terminal 1 or 4
TERMINAL
1500
1510 µ
HP rating N/A
1520 µ
125V & 250V 1/2 HP
H terminal rated T100 only
C
6.3 x 0.8
H
4.8 x 0.8
K
2.8 x 0.8
T
Solder
X
PCB 0.8Sq
9.1
7.0
Ø2.1
9.1
9.1
2.0
1.2
9.1
4.0
12 3
45 6
In house test
RoHS
CAT 170 P18-29 1500-6000_2_11-0328:CAT 170 P18-29 1500/6000 23/5/11 08:42 Page 26
Finish Matt is standard
Color Call factory for custom colors
A full range is available for large orders
Legend printing Call factory for custom
legends. State if a legend is to appear on the
right or left hand unit (viewed from the front)
Lamp voltage Call factory for details
For all options call the factory
602A(W) 1091(W)
C1500/1500AL C1500/0430AL
C1500/1520AL
C1500/1500XL
C430/430AL
C1520/1510AL
Examples of our range of legend printing
( ) is legend color B-Black, W-White, R-Red
25
Phone: 760-343-3650
Arcolectric E
mail: americas@elektron-technology.com
rocker
switches
27
APanel cut-outs Bezel
Gloss or Matt
B
Matt only
L
Matt only
Q
Gloss or matt
R
Matt only
T
Matt only
BODY DIMENSIONS (mm)
OPTIONS
22.3/22.4
27.2
27.3
22.1/22.2
30.0
30.1
22.3/22.4
28.2
28.3
22.3/22.4
28.2
28.3
23.0/25.4
28.4
28.5
22.1/22.2
30.0
30.1
25.0
30.2
25.0
33.4
R3.5
32.0
25.0
R1.0
25.0
30.2
R1.6
28.9
33.2
30.2
25.0
R1.6
Panel thickness
A,Q 0.75 to 3.3mm
L,B,T 0.75 to 2.5mm
R0.75 to 3.0mm
2.0 25.3 Max
9.2
13.2
7.6
Call sales for terminal spacing details
feather-edge seal
collar
Splash Resistant
1500 W and B splash resistant options
Feather edge seals and a close fitting collar protect current
carrying parts from moisture.
B option has Hytrel collar/seals for enhanced protection.
Cut-outs must be punched in the direction of insertion
Twin units
Two single switches or a switch and an indicator light can be
assembled side by side in one double pole body.
For twin units the first set of order format details refer to the
left hand unit, when looking at the front of the assembly.
(This has terminal numbers 1, 2 & 3)
1
2
3
4
5
6
1
2
3
4
5
6
CAT 170 P18-29 1500-6000_2_11-0328:CAT 170 P18-29 1500/6000 23/5/11 08:42 Page 27
26
ASoftline Matt
BSplash resistant (with Arcshield)
VCurved
WSplash resistant (with Arcshield)
PLit window Matt
XTwo color Matt
FFlat lens Gloss (0480 only)
ASoftline lens Matt (0480 only)
as F but with raised profile
RRound
ORDER FORMAT TERMINAL FUNCTION ROCKER BODY BODY ROCKER LAMP VOLTAGE LEGEND &
CODE CODE CODE CODE COLOR COLOR OR ON LIGHT” OPTIONS
C 1353 A L B R 2 602AW
NON-LIT LIT
BBLACK BBLACK AAMBER X ROCKER COLOR R,G,W,B
RRED RRED CCLEAR 2125V NEON
WWHITE WWHITE GGREEN 3250V NEON
RRED 712V INCANDESCENT
Standard rocker switch
1350/53 high inrush
Choice of switching
circuits including 3
position
Push-on, solder and
PCB terminals
Choice of bezel styles
Choice of 6 panel cut
outs
We match all major
brands
Matching indicator
Double pole
Splashproof option
Panel cut out A style:
27.2 x 22.3mm
Phone: 760-343-3650
Arcolectric E
mail: americas@elektron-technology.com
rocker
switches
28
1550 Series 16(4)A 250Vac T125
UL CSA 16A 250Vac, (2 posn) 250Vac 1hp, 125Vac 1/2hp,
(3 posn) 250 Vac 1/2hp, 125Vac 1/4hp.
UL 85˚C, file E45221, CSA file LR10990.
10A 24Vdc.
1350 series 16(4)A 250Vac T85 1E4 (10,000 Ops.)
1330 series 16(6)A 250Vac T125 5E4 (50,000 Ops.)
150A Inrush to EN61058-1.
UL CSA 20A 250Vac 1hp, 125Vac 1/2hp.
UL 72Vdc 7A, 36Vdc 14A.
UL 85˚C, file E45221, CSA file LR10990.
20A 24Vdc
RoHS compliant
3mm contact gap except if marked µ.
Technical data on pages 4 & 5 (switches), 6 (indicators).
ON - OFF
1550 Standard & 1350 High Inrush Switches150A to EN61058-1 and 16A 250Vac
ROCKERFUNCTION
Approvals & ratings vary with function
ON OFF Switches - ON when pressed over terminal 1
TERMINAL
High Inrush
1350
Not W, X or B rocker
C
6.3 x 0.8
H
4.8 x 0.8*
K
2.8 x 0.8*
T
Solder
U
Right angle T Solder (Not DP)
X
PCB 0.8Sq*
*Contact sales for details on 1350 series
9.1
7.0
Ø2.1
9.1
9.1
2.0
1.2
3.2
Ø2.1
9.1
4.0
12 3
45 6
In house test
In house test
Standard
1550
ON - OFF
(momentary ON)
1551
HP rating N/A
ON - OFF
(momentary OFF)
1552
HP rating N/A
ON - OFF
Lit
1353
Not W, X or B rocker
1553
Not W, X or B rocker
ON - ON
1560 µ
ON - ON
(momentary 1 side)
1561 µ
HP rating N/A
2 Circuit
ON - ON
1562 µ
In house tests only
ON - OFF - ON
1570 µ
125V & 250V 1/2 HP
H terminal rated T100 only
ON - OFF - ON
(momentary 1 side)
1571 µ
HP rating N/A
H terminal rated T100 only
ON - OFF - ON
(momentary 2 sides)
1572 µ
HP rating N/A
H terminal rated T100 only
3 position selective
1484 µ
In-house tested to 10(3)A 250Vac
(B rocker only)
3 position selective
(Consult sales for other switch options)
1487 µ
In-house tested to 10(3)A 250Vac
(B rocker only)
Indicator
Technical data on page 6
0480
X terminal N/A
12
4
5
3
6
12
4
5
3
6
12
4
5
3
6
12
4
5
3
6
12
4
5
3
6
12
4
5
3
6
Lit (not momentary)
Lit (not momentary)
Lit (not momentary)
Matt or gloss Gloss only
Top view
RoHS
CAT 170 P18-29 1500-6000_2_11-0328:CAT 170 P18-29 1500/6000 23/5/11 08:42 Page 28
602A(W) 730(W) 822(W)
Examples of our range of legend printing
( ) is legend color B-Black, W-White, R-Red
27
Finish Matt is standard
Color Call factory for custom colors.
A full range is available for large orders
Legend printing Select from the examples or
call factory for custom legends
Lamp voltage Call factory for details
Hole plug 1580ABB
Dummy units to fill unused panel holes
Protective cover (designed to IP65)
Snaps on to A, L, Q or T bodies
(add G72 as a suffix). This reduces panel
thickness by 1mm.
Panel sealing washer W42 is available for the
above body sizes but reduces panel thickness
by a further 1.00mm.
Covers are not suitable for momentary types.
For all options call the factory
Phone: 760-343-3650
Arcolectric E
mail: americas@elektron-technology.com
rocker
switches
29
A
Gloss or Matt
B
Matt only
L
Matt only
Q
Gloss or matt
R
Matt only
T
Matt only
BODY DIMENSIONS (mm)
Panel cut-out * Bezel
OPTIONS
Panel thickness
A,Q 0.75 to 3.3mm
L,B,T 0.75 to 2.5mm
R0.75 to 3.0mm
* For cut-out details on
momentary switches call sales.
2.0 25.3 Max
9.2
13.2
7.6
Terminal spacing - Poles 10.2 between centres
22.3/22.4
27.2
27.3
22.1/22.2
30.0
30.1
22.3/22.4
28.2
28.3
22.3/22.4
28.2
28.3
23.0/25.4
28.4
28.5
22.1/22.2
30.0
30.1
25.0
30.2
25.0
33.4
R3.5
32.0
25.0
R1.0
25.0
30.2
R1.6
28.9
33.2
30.2
25.0
R1.6
Cut-outs must be punched in the direction of insertion
plunger tube
1350 High inrush, positive break switching
The 1350 series mechanism ensures
contact welds formed at switch-on,
are positively separated by the
plunger tube acting directly on the
step in the moving contact.
step
C1350AL ---
C0480AL ---
C1550XL --- C1553PL --- C1553RA ---
Shown with M614 bezel cover
C0480RA ---
Shown with M614 bezel cover
C1553AA with M616 guard
Cut-out 22.0/22.1 x 29.4/29.5
Guard accepts “A body only
Optional snap-in M441 barrier
CAT 170 P18-29 1500-6000_2_11-0328:CAT 170 P18-29 1500/6000 23/5/11 08:42 Page 29
26
ASoftline Matt
VCurved
PLit window Matt
ORDER FORMAT TERMINAL FUNCTION ROCKER BODY BODY ROCKER LAMP VOLTAGE LEGEND &
CODE CODE CODE CODE COLOR COLOR OR “ON LIGHT” OPTIONS
C 1353 A G B R 2 602AW
NON-LIT LIT
BBLACK BBLACK AAMBER X ROCKER COLOR R,G,W,B
RRED RRED CCLEAR 2125V NEON
WWHITE WWHITE GGREEN 3250V NEON
RRED 712V INCANDESCENT
With Integral Guard or Cover
Standard rocker switch
1350/53 high inrush
Choice of switching
circuits including 3
position
Push-on, solder and
PCB terminals
Choice of bezel styles
Choice of panel cut outs
Matching indicator
Double pole
Option with integral
guard & cover
Bezel size ‘G’ style
32.0 x 25.0
Phone: 760-343-3650
Arcolectric E
mail: americas@elektron-technology.com
GGUARD
HCOVER
rocker
switches
30
1550 Series 16(4)A 250Vac T125
UL CSA 16A 250Vac, (2 posn) 250Vac 1hp, 125Vac 1/2hp,
(3 posn) 250 Vac 1/2hp, 125Vac 1/4hp.
UL 85˚C, file E45221, CSA file LR10990.
10A 24Vdc.
1350 Series
UL CSA 20A 250Vac 1hp, 125Vac 1/2hp.
UL 72Vdc 7A, 36Vdc 14A.
UL 85˚C, file E45221, CSA file LR10990.
20A 24Vdc
RoHS compliant
3mm contact gap except if marked µ.
Technical data on pages 4 & 5 (switches), 6 (indicators).
ON - OFF
1550 Standard & 1350 High Inrush Switches 150A to EN61058-1 and 16A 250Vac
ROCKERFUNCTION
Approvals & ratings vary with function
ON OFF Switches - ON when pressed over terminal 1
TERMINAL
High Inrush
1350
C
6.3 x 0.8
H
4.8 x 0.8*
K
2.8 x 0.8*
T
Solder
U
Right angle T Solder (Not DP)
X
PCB 0.8Sq*
*Contact sales for details on 1350 series
9.1
7.0
Ø2.1
9.1
9.1
2.0
1.2
3.2
Ø2.1
9.1
4.0
12 3
45 6
In house test
In house test
Standard
1550
ON - OFF
(momentary ON)
1551
HP rating N/A
ON - OFF
(momentary OFF)
1552
HP rating N/A
ON - OFF
Lit
1353
1553
ON - ON
1560 µ
ON - ON
(momentary 1 side)
1561 µ
HP rating N/A
2 Circuit
ON - ON
1562 µ
In house tests only
ON - OFF - ON
1570 µ
125V & 250V 1/2 HP
H terminal rated T100 only
ON - OFF - ON
(momentary 1 side)
1571 µ
HP rating N/A
H terminal rated T100 only
ON - OFF - ON
(momentary 2 sides)
1572 µ
HP rating N/A
H terminal rated T100 only
Lit (not momentary)
Lit (not momentary)
Lit (not momentary)
Matt or gloss Gloss only
RoHS
CAT 170 P30-31 1500G_11-0328:1500 with Guard DS 23/5/11 08:49 Page 30
602A(W) 730(W) 822(W)
Examples of our range of legend printing
( ) is legend color B-Black, W-White, R-Red
27
Finish Matt is standard
Color Call sales for custom colors.
A full range is available for large orders
Legend printing Select from the examples or
call sales for custom legends
GGuard color must match body color
HClear cover standard with lighted switches.
Black standard with non-lighted
Phone: 760-343-3650
Arcolectric E
mail: americas@elektron-technology.com
rocker
switches
GWith Guard
Matt only
HWith Cover
Matt only
BODY DIMENSIONS (mm)
Panel cut-out * Bezel
OPTIONS
Panel thickness
G, H 0.75 to 2.5mm
* For cut-out details on
momentary switches call sales.
2.0 25.3 Max
9.2
13.2
7.6
9.2
Terminal spacing - Poles 10.2 between centres
22.1/22.2
30.0
30.1
22.1/22.2
30.0
30.1
32.0
25.0
25.0
32.0
Cut-outs must be punched in the direction of insertion
plunger tube
1350 High inrush, positive break switching
The 1350 series mechanism ensures
contact welds formed at switch-on,
are positively separated by the
plunger tube acting directly on the
step in the moving contact.
step
C1550AH --- C1553AH ---
31
CAT 170 P30-31 1500G_11-0328:1500 with Guard DS 23/5/11 08:49 Page 31
rocker
switches
32
R13 Round Rocker Switches 10A 250Vac
PRODUCT
DETAILS DIMENSIONS (mm)
7.1 7.1
8.1
14.5
5.5
123
Ø23.0
2.0
0.9
Ø20.2
2.2
Ø17.0
4.8x0.8
1 2
12
R
12
R
123
1
123
1
123
123
123
Snap fixing into panel thickness up to 3.0
* R13 208F has 12.5mm deep body
*
5.0
8.5
15.8
5.5
12
Ø23.5
2.0
7.8
Ø17.0
only
Double pole
Panel cut-out
Single pole
Miniature round rocker
switch
Ratings up to 10A,
250Vac
Single & double pole
Illuminated & non-
illuminated, neon and
LED
Choice of actuators
Matching indicator
Panel cut out:
20.2 dia.
RoHS
SP ON - OFF µ
Cat no.
R13 112ABB-602AW
SP ON - OFF µ
Cat no.
R13 112AWW-602AB
SP ON - OFF µ
Lit 110V
Cat no.
R13 112BBBR2
SP ON - OFF µ
Lit 110V
Cat no.
R13 112BBG2
DP ON - OFF
Lit 110V
Cat no.
R13 244ABB-602AW
SP ON - OFF µ
Lit 110V
Cat no.
R13 112BWR2
SP ON - ON µ
Cat no.
R13 112CBB
SP ON - OFF - ON µ
Cat no.
R13 112DBB-730W
SP ON - OFF µ
(Momentary On)*
Cat no.
R13 208FBB
DP ON - OFF
Lit 110V
Cat no.
R13 244BBR2
SP 6A 250Vac T85,
DP 10(4)A 250Vac T85
UL CSA SP 10A 125Vac & 6A 250Vac (For 16A call the factory)
UL CSA DP 8A 125/250Vac
UL 85˚C, file E67774(S)
CSA file LR45128
RoHS compliant
Single pole has µ contact gap.
Technical data on pages 4 & 5.
Standard products
Are supplied with the body and rocker color, print & lamp voltage shown in
the product illustration and description.
Phone: 760-343-3650
Arcolectric E
mail: americas@elektron-technology.com
CAT 170 P32-33 R13 ROUND_2_11-0328:CAT 170 P32-33 R13 ROUND 23/5/11 08:51 Page 32
rocker
switches
33
PRODUCT
DETAILS PANEL CUT-OUT (mm)
0.9
Ø20.2
2.2
1 2
123
12 3+
3
-
13
Snap fixing into panel thickness up to 3.0
approvals - contact sales
Ø17.0
4.8x0.8
7.1
8.1
14.5
321
Ø23.0
2.0 5.5
Ø17.0
4.8x0.8
7.1 7.1
8.1
14.5
5.5
123
Ø23.0
2.0
Ø15.0
4.8x0.8
7.1 7.1
8.1
14.5
10.0
123
Ø23.0
Ø
2.0
Ø17.0
4.8x0.8
14.2
8.1
14.5
4.0
13
Ø23.0
2.0
Protective cover L188
Snaps on to bodies (not R13 211 or R13 112LP), this
reduces maximum acceptable panel thickness to
2.4mm.
SP ON - OFF µ
Bright colour ON signal
Cat no.
R13 112A2BBR
SP ON - OFF µ
Lit Window 110V
Cat no.
R13 112B2BR2
SP ON - OFF µ
Paddle tip has red LED
Cat no.
R13 112LPBBR
Indicator light 110V
Cat no.
R9 92B BR2
ORDER FORMAT
SERIES HOUSING FUNCTION BODY ROCKER LAMP VOLTAGE IMPRINT
COLOR COLOR
R13 112 A B B 2 602A
BBLACK
WWHITE
22125V NEON
3250V NEON
712V LED
824V LED
BBLACK
WWHITE
RRED LIGHTED
GGREEN LIGHTED
AAMBER LIGHTED
BL BLUE LIGHTED
A2 X ROCKER 2nd
AON-OFF
A2 X ROCKER
BLIGHTED ON-OFF
B2 WINDOW LENS
CON-NONE-ON
DON-OFF-ON
EON-(OFF)
F(ON)-OFF
GON-(ON)
HON-OFF-(ON)
I(ON)-OFF-(ON)
LP LIGHTED PADDLE 602A IO VERTICAL
112 SP Snap in 23mm round
244 DP Snap in 23mm round
135 SP Snap in 23x23 square
112 Sub Panel 13x19mm cut out
R13 SWITCH
R9 INDICATOR
Phone: 760-343-3650
Arcolectric • E
mail: americas@elektron-technology.com
R13 112B R13 112A R13 112A2 ---