C B 2 2 0 0 S e r i e s S u p p l e m e n t a l C i rc u i t B re a k e r s Circuit Breakers Thermal Magnetic Type CB2200 Series Single Pole CB2200 Series Double Pole CB2200 Series Triple Pole * Rated from 0.1 to 32.0 amps * Available in single, double and triple pole configurations * Offers normally open (N/O) and normally closed (N/C) auxiliary contacts * Lever-switch trip/reset function * Mounts on 32mm or 35mm DIN-rail * UL 1077 recognized * CSA C22.2 No. 235 Ordering Data Type: Single Pole* Type: Double Pole Type: Triple Pole Current Ratings (amps) 0.1 0.2 N/O Aux. Part No. 9911010005 9911020005 Current Ratings (amps) 0.1 0.2 N/O-N/C Part No. 9912010003 9912020003 Current Ratings (amps) 0.1 0.2 N/O-N/C Part No. 9913010003 9913020003 0.3 0.4 0.5 9911030005 9911040005 9911050005 0.3 0.4 0.5 9912030003 9912040003 9912050003 0.3 0.4 0.5 9913030003 9913040003 9913050003 0.6 0.8 1.0 9911060005 9911080005 9911100005 0.6 0.8 1.0 9912060003 9912080003 9912100003 0.6 0.8 1.0 9913060003 9913080003 9913100003 1.5 2.0 2.5 9911150005 9911200005 9911250005 1.5 2.0 2.5 9912150003 9912200003 9912250003 1.5 2.0 2.5 9913150003 9913200003 9913250003 3.0 4.0 5.0 9911300005 9911400005 9911500005 3.0 4.0 5.0 9912300003 9912400003 9912500003 3.0 4.0 5.0 9913300003 9913400003 9913500003 6.0 8.0 10 9911600005 9911800005 9921100005 6.0 8.0 10 9912600003 9912800003 9922100003 6.0 8.0 10 9913600003 9913800003 9923100003 12 15 16 9921120005 9921150005 9921160005 12 15 16 9922120003 9922150003 9922160003 12 15 16 9923120003 9923150003 9923160003 18 20 25 9921180005 9921200005 9921250005 18 20 9922180003 9922200003 18 20 9923180003 9923200003 32 9921320005 *All part numbers with N/O Auxiliary Contacts on each pole when the main breaker contact is open (in the OFF position) Ordering Data Type: Single Pole Type: Double Pole Type: Triple Pole All part numbers with N/C Auxiliary Contacts on each pole when the main breaker contact is open (in the OFF position) Current Ratings Current Ratings Current Ratings (amps) Part No. (amps) Part No. (amps) Part No. 60 0.1 0.2 0.3 9911010000 9911020000 9911030000 0.1 0.2 0.3 9912010000 9912020000 9912030000 0.1 0.2 0.3 9913010000 9913020000 9913030000 0.4 0.5 0.6 9911040000 9911050000 9911060000 0.4 0.5 0.6 9912040000 9912050000 9912060000 0.4 0.5 0.6 9913040000 9913050000 9913060000 0.8 1.0 1.5 9911080000 9911100000 9911150000 0.8 1.0 1.5 9912080000 9912100000 9912150000 0.8 1.0 1.5 9913080000 9913100000 9913150000 2.0 2.5 9911200000 9911250000 2.0 2.5 9912200000 9912250000 2.0 2.5 9913200000 9913250000 3.0 4.0 5.0 6.0 9911300000 9911400000 9911500000 9911600000 3.0 4.0 5.0 6.0 9912300000 9912400000 9912500000 9912600000 3.0 4.0 5.0 6.0 9913300000 9913400000 9913500000 9913600000 8.0 10 12 9911800000 9921100000 9921120000 8.0 10 12 9912800000 9922100000 9922120000 8.0 10 12 9913800000 9923100000 9923120000 15 16 18 9921150000 9921160000 9921180000 15 16 18 9922150000 9922160000 9922180000 15 16 18 9923150000 9923160000 9923180000 20 25 32 9921200000 9921250000 9921320000 20 25 32 9922200000 9922250000 9922320000 20 25 32 9923200000 9923250000 9923320000 C B 2 2 0 0 S e r i e s S u p p l e m e n t a l C i rc u i t B re a k e r s CB2200 Series Trip Curves--Thermal Magnetic Type Typical time/current characteristics at 23C CB2200 Series F1 0.1 to 32 A 10,000 -30C +23C +55C Trip time in seconds 1,000 100 10 1 0.1 0.01 0.001 .8 1 3 4 2 6 8 10 20 30 50 70 100 ...times rated current -M1 0.1 to 7.5 A 10,000 -30C AC +23C DC +23C +55C Voltage Ratings UL CSA VDE Current Ratings 277 / 480 VAC (50/60 Hz); 65 VDC 277 / 480 VAC (50/60 Hz); 65 VDC 250 / 415 VAC / 65 VDC Auxiliary contacts Creepage resistance Dielectric strength 250 VAC / 65 VDC, 1 A PTI 600 to IEC 112 3,000 VAC; IEC 664 & 664 A Insulation resistance Interrupting capacity (VDE 0660, Part 101, P-2) > 100 MM (DC 500 V) Rated current Rated voltage 0.05...0.8 A 250 / 415 VAC Rupture capacity (3 times) 400 A 6...32 A 800 A Interrupting capacity (UL 1077/EN 60934 PC1) 250 / 415 VAC Max. rupture capacity (3 times) 0.1...16 A 20...32 A 0.1...32 A 5000 A 2000 A 2000 A BDC 50, 20 A maximum 1 pole (CB2200) 2 pole (CB2200) 6 8 10 20 30 50 70 100 8 to 32 A -30C AC +23C DC +23C +55C 100 10 DC 0.1 0.001 0.6 (5.3) Auxiliary contact: 0.5 (4.4) 5 g (57 to 500 Hz / 0.38 mm, 10 to 57 Hz) to IEC 68-2-6, Test Fc -30...+60C (-22F...+140F) Type Daisy Chain 50 3 4 1,000 AC 0.01 .8 1 2 3 4 6 8 10 20 30 50 70 100 ...times rated current -T1 0.1 to 7.5 A 10,000 -30C +23C +55C 1,000 max 6 mm2...8 AWG max 1.5 mm2...14 AWG (Aux. contact) Accessories 2 -M1 96 hours at 5% salt spray, to IEC 68-2-11, Test Ka 240 hours at 95% RH, to IEC 68-2-3, Test Ca Approximately 60 g per pole Jumpers Busbars .8 1 10,000 Part No. 9970290000 9986510000 9987360000 Trip time in seconds Nm (lb. in.) DC AC 0.01 0.001 5,000 operations 25 g (11 ms) to IEC 68-2-27, Test Ea Typical life at 2 x rated current Shock Torque Vibration Temperature range Corrosion Humidity Weight Wire size (UL) 10 ...times rated current Rated current Rated voltage 277 / 480 VAC 277 / 480 VAC 65 VDC 10 0.1 0.1...32 A 0.1...32 A 0.1...32 A Trip time in seconds Technical Data Rated voltage & current 100 T Dimensions in mm Trip time in seconds 1,000 100 10 0.1 0.01 Marking Tags 1 2 3 4 5 6 Note: Part numbers shown are for a single card of pre-printed tags numbered 1-50. Special print only Consecutive horizontal Consecutive vertical DEK 5/6 DEK 5/6 DEK 5/6 0.001 0490360000* 0468660001 0468760001 .8 1 2 3 4 6 8 10 20 30 50 70 100 ...times rated current -T1 8 to 32 A 10,000 Note: Resistive and inductive loads (0.05 - 16 A) *Please specify horizontal or vertical print when ordering. -30C +23C +55C Trip time in seconds 1,000 100 10 1 0.1 0.01 0.001 .8 1 2 3 4 6 8 10 20 30 50 70 100 ...times rated current 61