Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715 28 V Maxi Family Rev. 2.2 Page 1 of 11
Set your site on VICOR at vicorpower.com
Features
DC input range: 9 – 36 V*
Isolated output
Input surge withstand: 50 V for 100 ms
DC output: 3.3 – 48 V
Programmable output: 10 to 110%
Regulation: ±0.2% no load to full load
Efficiency: Up to 85%
Maximum operating temp: 100°C
Power density: up to 40 W per cubic inch
Height above board: 0.43 in. (10,9 mm)
Parallelable, with N+M fault tolerance
Low noise ZCS/ZVS architecture
RoHS Compliant (with F or G pin option)
Product Overview
These DC-DC converter modules use
advanced power processing, control and
packaging technologies to provide the
performance, flexibility, reliability and cost
effectiveness of a mature power component.
High frequency ZCS/ZVS switching
provides high power density with low
noise and high efficiency.
Applications
Industrial and process control, distributed
power, medical, ATE, communications,
defense, aerospace.
*10-36 V DC input range for 3.3, 6.5, 8, 36
and 48 V outputs. All others derate power
to 75% for Vin 9 – 10 V.
For details on proper operation please refer
to the Design Guide & Applications Manual
for Maxi, Mini, Micro Family.
Parameter Rating Unit Notes
+In to –In voltage -0.5 to +53 Vdc
PC to –In voltage -0.5 to +7.0 Vdc
PR to –In voltage -0.5 to +7.0 Vdc
SC to -Out voltage -0.5 to +1.5 Vdc
-Sense to -Out voltage 1.0 Vdc
+Out to -Out, +Sense to -Out See Module Output
Specifications
Isolation voltage
in to out 3000 Vrms Test voltage
in to base 1500 Vrms Test voltage
out to base 500 Vrms Test voltage
Operating Temperature -55 to +100 °C M-Grade
Storage Temperature -65 to +125 °C M-Grade
Pin soldering temperature 500 (260) °F (°C) <5 sec; wave solder
750 (390) °F (°C) <7 sec; hand solder
Mounting torque 5 (0.57) in-lbs (N-m) 6 each
Output Voltage
3 V 3 = 3.3 V
5= 5 V
6.5 = 6.5 V
8= 8 V
12 = 12 V
15 = 15 V
24 = 24 V
28 = 28 V
36 = 36 V
48 = 48 V
Product Grade Temperatures (°C)
Grade Operating Storage
C=
-
20 to +100
-
40 to +125
T=
-
40 to +100
-
40 to +125
H=
-
40 to +100
-
55 to +125
M=
-
55 to +100
-
65 to +125
Output Power
Vout Pout
3.3 V 150 W
5 V 175 W
6.5 V 200 W
8 V 200 W
12 V 200 W
15 V 200 W
24 V 200 W
28 V 200 W
36 V 200 W
48 V 200 W
Data Sheet
28V Wide Input Maxi Family
DC-DC Converter Module
Shown actual size:
4.6 x 2.2 x 0.5 in
117 x 56 x 12,7 mm
Absolute Maximum Ratings
Part Numbering
e.g. V28A12T200BL2
V28AB
Pin Style Finish
Blank: Short Tin/Lead
L: Long Tin/Lead
S: Short ModuMate Gold
N: Long ModuMate Gold
F: Short RoHS Gold
G: Long RoHS Gold
Baseplate
Blank: Slotted
2: Threaded
3: Through-hole
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715 28 V Maxi Family Rev. 2.2 Page 2 of 11
Set your site on VICOR at vicorpower.com
MODULE OUTPUT SPECIFICATIONS
Electrical characteristics apply over the full operating range of input voltage, output load (resistive) and baseplate temperature,
unless otherwise specified. All temperatures refer to the operating temperature at the center of the baseplate.
Parameter Min Typ Max Unit
Baseplate to sink; flat, greased surface 0.08 °C / Watt
Baseplate to sink; thermal pad (P/N 20263) 0.07 °C /Watt
Baseplate to ambient 4.9 °C / Watt
Baseplate to ambient; 1000 LFM 1.1 °C / Watt
Thermal capacity 165 Watt-sec/°C
THERMAL RESISTANCE AND CAPACITY
MODULE FAMILY ELECTRICAL CHARACTERISTICS
Parameter Min Typ Max Unit Notes
Output voltage set point ±1% Vout nom Nominal input; full load; 25°C
Line regulation ±0.02 ±0.20 % Low line to high line; full load
Temperature regulation ±0.002 ±0.005 % / °C Over operating temperature range
Power sharing accuracy ±2 ±5 % 10 to 100% of full load
Of nominal output voltage. For trimming below 90%
Programming range 10 110 % of nominal, a minimum load of 10% of maximum
rated power may be required.
+Out to -Out, +Sense to -Out – Absolute Maximum Ratings
3.3 V -0.5 to 4.7 Vdc Externally Applied
5 V -0.5 to 7.0 Vdc Externally Applied
6.5 V -0.5 to 9.0 Vdc Externally Applied
8 V -0.5 to 10.9 Vdc Externally Applied
12 V -0.5 to 16.1 Vdc Externally Applied
15 V -0.5 to 20.0 Vdc Externally Applied
24 V -0.5 to 31.7 Vdc Externally Applied
28 V -0.5 to 36.9 Vdc Externally Applied
36 V -0.5 to 47.2 Vdc Externally Applied
48 V -0.5 to 62.9 Vdc Externally Applied
Parameter Min Typ Max Unit Notes
Operating input voltage 9 28 36 Vdc
Input surge withstand 50 Vdc <100 ms
Undervoltage turn-on 8.75 8.9 Vdc
Undervoltage turn-off 7.8 8.1 8.4 Vdc
Overvoltage turn-off/on 36.3 37.8 39.6 Vdc
Disabled input current 12 14 mA PC pin low
MODULE INPUT SPECIFICATIONS
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715 28 V Maxi Family Rev. 2.2 Page 3 of 11
Set your site on VICOR at vicorpower.com
Parameter Min Typ Max Unit Notes
PRIMARY SIDE (PC = Primary Control; PR = Parallel)
PC bias voltage 5.50 5.75 6.00 Vdc PC current = 1.0 mA
current limit 1.5 2.1 3.0 mA PC voltage = 5.5 V During normal operation
PC module disable 2.3 2.6 2.9 Vdc Switch must be able to sink 4 mA. See Fig. 2
PC module enable delay 4 7 ms
PC module alarm 0.5 Vavg UV, OV, OT, module fault. See Figs. 3 and 5
PC resistance 0.9 1.0 1.1 MSee Fig. 3, converter off or fault mode
PR emitter amplitude 5.7 5.9 6.1 Volts PR load >30 , <30 pF
PR emitter current 150 mA
PR receiver impedance 375 500 625 25°C
PR receiver threshold 2.4 2.5 2.6 Volts Minimum pulse width: 20 ns
PR drive capability 12 modules Without PR buffer amplifier
SECONDARY SIDE (SC = Secondary Control)
SC bandgap voltage 1.21 1.23 1.25 Vdc Referenced to –Sense
SC resistance 990 1000 1010
SC capacitance 0.033 µF
SC module alarm 0 Vdc With open trim; referenced toSense. See Fig. 7
Parameter Min Typ Max Unit Notes
Remote sense (total drop) 0.5 Vdc 0.25 V per leg (sense leads must be connected to
respective, output terminals)
Isolation test voltage (in to out)* 3000 Vrms Complies with reinforced insulation requirements
Isolation test voltage (in to base)* 1500 Vrms Complies with basic insulation requirements
Isolation test voltage (out to base)* 500 Vrms Complies with operational insulation requirements
Isolation resistance 10 Min to out, in to baseplate, out to baseplate
Weight (E, C, T grade) 6.5 7.3 8.1 ounces
(184.3) (207.5) (230.7) (grams)
Weight (H, M grade) 7.4 8.2 9.0 ounces
(209.3) (232.5) (255.7) (grams)
Temperature limiting 100 115 °C See Figs. 3 and 5. Do not operate coverter >100C.
Agency approvals cURus, cTÜVus, CE UL60950-1, EN60950-1, CSA60950-1, IEC60950-1.
With appropriate fuse in series with the +Input
MODULE CONTROL SPECIFICATIONS
MODULE GENERAL SPECIFICATIONS
* Isolation test voltage, 1 minute or less.
Note:
Specifications are subject to change without notice.
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715 28 V Maxi Family Rev. 2.2 Page 4 of 11
Set your site on VICOR at vicorpower.com
Parameter Min Typ Max Unit Notes
Efficiency 77.3 78.6 % Nominal input; full load; 25°C
Ripple and noise 80 100 mV p-p; Nominal input; full load; 20 MHz bandwidth
Output OVP set point 4.14 4.30 4.46 Volts 25°C; recycle input voltage or PC to restart (>100 ms off)
Dissipation, stand-by 11.4 12.7 Watts No load
Load regulation ±0.02 ±0.2 % No load to full load; nominal input
Load Current 0 45.45 Amps
Current limit 46.4 52.3 61.5 Amps Output voltage 95% of nominal
Short circuit current 31.8 52.3 61.5 Amps Output voltage <250 mV
3.3 Vout, 150 W (e.g. V28A3V3C150BL)
Parameter Min Typ Max Unit Notes
Efficiency 75.7 76.8 % Nominal input; full load; 25°C
Ripple and noise 280 350 mV p-p; Nominal input; full load; 20 MHz bandwidth
Output OVP set point 6.03 6.25 6.47 Volts 25°C; recycle input voltage or PC to restart (>100 ms off)
Dissipation, stand-by 14.4 15.5 Watts No load
Load regulation ±0.02 ±0.2 % No load to full load; nominal input
Load Curent 0 35 Amps
Current limit 35.7 40.3 49.0 Amps Output voltage 95% of nominal
Short circuit current 24.5 40.3 47.3 Amps Output voltage <250 mV
5 Vout, 175 W (e.g. V28A5C175BL)
Parameter Min Typ Max Unit Notes
Efficiency 76.8 78.8 % Nominal input; full load; 25°C
Ripple and noise 275 344 mV p-p; Nominal input; full load; 20 MHz bandwidth
Output OVP setpoint 7.7 7.98 8.26 Volts 25°C; recycle input voltage or PC to restart (>100 ms off)
Dissipation, standby 11.6 12.2 Watts No load
Load regulation ±0.02 ±0.2 % No load to full load; nominal input
Output Current 0 30.77 Amps
Current limit 31.4 35.4 41.6 Amps Output voltage 95% of nominal
Short circuit current 21.5 35.4 41.6 Amps Output voltage <250 mV
6.5 Vout, 200 W (e.g. V28A6V5C200BL)
Parameter Min Typ Max Unit Notes
Efficiency 79.5 80.9 % Nominal input; full load; 25°C
Ripple and noise 325 407 mV p-p; Nominal input; full load; 20 MHz bandwidth
Output OVP setpoint 9.36 9.7 10.1 Volts 25°C; recycle input voltage or PC to restart (>100 ms off)
Dissipation, standby 15.6 16.5 Watts No load
Load regulation ±0.02 ±0.2 % No load to full load; nominal input
Output Current 0 25 Amps
Current limit 25.5 28.8 33.8 Amps Output voltage 95% of nominal
Short circuit current 17.5 28.8 33.8 Amps Output voltage <250 mV
8 Vout, 200 W (e.g. V28A8C200BL)
MODULE SPECIFIC OPERATING SPECIFICATIONS
Parameter Min Typ Max Unit Notes
Efficiency 81.0 83.0 % Nominal input; full load; 25°C
Ripple and noise 280 350 mV p-p; Nominal input; full load; 20 MHz bandwidth
Output OVP set point 13.7 14.3 14.9 Volts 25°C; recycle input voltage or PC to restart (>100 ms off)
Dissipation, stand-by 11.0 12.2 Watts No load
Load regulation ±0.02 ±0.2 % No load to full load; nominal input
Load Current 0 16.67 Amps
Current limit 17.0 19.2 22.6 Amps Output voltage 95% of nominal
Short circuit current 11.6 19.2 22.6 Amps Output voltage < 250mV
12 Vout, 200 W (e.g. V28A12C200BL)
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715 28 V Maxi Family Rev. 2.2 Page 5 of 11
Set your site on VICOR at vicorpower.com
Parameter Min Typ Max Unit Notes
Efficiency 83.5 85.0 % Nominal input; full load; 25°C
Ripple and noise 200 250 mV p-p; Nominal input; full load; 20 MHz bandwidth
Output OVP set point 31.5 32.7 33.9 Volts 25°C; recycle input voltage or PC to restart (>100 ms off)
Dissipation, stand-by 15.5 18.0 Watts No load
Load regulation ±0.02 ±0.2 % No load to full load; nominal input
Load Current 0 7.14 Amps
Current limit 7.28 8.2 10.0 Amps Output voltage 95% of nominal
Short circuit current 4.99 8.2 10.0 Amps Output voltage <250 mV
28 Vout, 200 W (e.g. V28A28C200BL)
MODULE SPECIFIC OPERATING SPECIFICATIONS
Parameter Min Typ Max Unit Notes
Efficiency 82.8 86.0 % Nominal input; full load; 25°C
Ripple and noise 315 394 mV p-p; Nominal input; full load; 20 MHz bandwidth
Output OVP set point 27.1 28.1 29.1 Volts 25°C; recycle input voltage or PC to restart (>100 ms off)
Dissipation, stand-by 12.3 13.5 Watts No load
Load regulation ±0.02 ±0.2 % No load to full load; nominal input
Load Current 0 8.33 Amps
Current limit 8.49 9.6 11.3 Amps Output voltage 95% of nominal
Short circuit current 5.83 9.6 11.3 Amps Output voltage <250 mV
24 Vout, 200 W (e.g. V28A24C200BL)
Parameter Min Typ Max Unit Notes
Efficiency 82.2 84.5 % Nominal input; full load; 25°C
Ripple and noise 220 275 mV p-p; Nominal input; full load; 20 MHz bandwidth
Output OVP set point 17.1 17.8 18.5 Volts 25°C; recycle input voltage or PC to restart (>100 ms off)
Dissipation, stand-by 12.7 13.7 Watts No load
Load regulation ±0.02 ±0.2 % No load to full load; nominal input
Load Current 0 13.33 Amps
Current limit 13.5 15.3 20.6 Amps Output voltage 95% of nominal
Short circuit current 9.31 15.3 20.6 Amps Output voltage <250 mV
15 Vout, 200 W (e.g. V28A15C200BL)
Parameter Min Typ Max Unit Notes
Efficiency 80.9 82.6 % Nominal input; full load; 25°C
Ripple and noise 225 282 mV p-p; Nominal input; full load; 20 MHz bandwidth
Output OVP set point 40.4 41.9 43.4 Volts 25°C; recycle input voltage or PC to restart (>100 ms off)
Dissipation, stand-by 14.4 16.8 Watts No load
Load regulation ±0.02 ±0.2 % No load to full load; nominal input
Load Current 0 5.56 Amps
Current limit 5.67 7.7 8.06 Amps Output voltage 95% of nominal
Short circuit current 3.89 6.9 7.5 Amps Output voltage <250 mV
36 Vout, 200 W (e.g. V28A36C200BL)
Parameter Min Typ Max Unit Notes
Efficiency 81.8 82.6 % Nominal input; full load; 25°C
Ripple and noise 360 450 mV p-p; Nominal input; full load; 20 MHz bandwidth
Output OVP set point 53.7 55.7 57.7 Volts 25°C; recycle input voltage or PC to restart (>100 ms off)
Dissipation, stand-by 15.6 18.3 Watts No load
Load regulation ±0.02 ±0.2 % No load to full load; nominal input
Load Current 0 4.17 Amps
Current limit 4.25 4.4 5.84 Amps Output voltage 95% of nominal
Short circuit current 2.92 4.8 5.43 Amps Output voltage <250 mV
48 Vout, 200 W (e.g. V28A48C200BL)
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715 28 V Maxi Family Rev. 2.2 Page 6 of 11
Set your site on VICOR at vicorpower.com
+IN
PC
PR
IN
+OUT
+S
SC
S
OUT
C3*
4.7nF
C2*
4.7nF
For C1 – C5, keep leads and connections short.
C5*
4.7nF
C4*
4.7nF
F1*
C1*
0.2µF
Figure 1 Basic module operation requires fusing, grounding, bypassing capacitors.
* See Maxi, Mini, Micro Design Guide.
BASIC MODULE OPERATION
Comprehensive Online Application Information
The Design Guide and Applications Manual includes:
Application circuits
Design requirements
EMC considerations
Current sharing in power arrays
Thermal performance information
Recommended soldering methods
Accessory modules – filtering, rectification, front-ends
Mounting options
...and more.
Also at vicorpower.com
PowerBench online configurators
Over 20 Application Notes
Online calculators – thermal, trimming, hold-up
PDF data sheets for ALL Vicor products
CLICK HERE TO VIEW
DESIGN GUIDE
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715 28 V Maxi Family Rev. 2.2 Page 7 of 11
Set your site on VICOR at vicorpower.com
Module Enable / Disable
The module may be disabled by pulling PC below 2.3 V with
respect to the –Input. This may be done with an open collector
transistor, relay, or optocoupler. Multiple converters may be
disabled with a single transistor or relay either directly or via
“OR’ing” diodes. See Figure 2.
Primary Auxiliary Supply
At 5.7 V, PC can source up to 1.5 mA. In the example shown
in Figure 4, PC powers a module enabled LED.
Module Alarm
The module contains “watchdog” circuitry which monitors
input voltage, operating temperature and internal operating
parameters. In the event that any of these parameters are
outside of their allowable operating range, the module will
shut down and PC will go low. PC will periodically go high
and the module will check to see if the fault (as an example,
overtemperature ) has cleared. If the fault has not been cleared,
PC will go low again and the cycle will restart. The SC pin
will go low in the event of a fault and return to its normal
state after the fault has been cleared. See Figures 3 and 5.
+IN
PC
PR
–IN
Disable
Disable = PC <2.3 V
Figure 2 Module enable / disable.
Figure 4 LED on-state indicator.
+IN
PC
PR
–IN
4 kΩ
"Module
Enabled"
+IN
PC
PR
–IN
Optocoupler
4 kΩ
Alarm
1.00V
+OUT
+S
SC
–S
–OUT
Comparator
+OUT
+S
SC
–S
OUT
+IN
PC
PR
–IN
Input Undervoltage
2-20 ms typ.
f (VIN)
Auto
Restart
5.7 Vdc
(0-3 mA)
50 Ω
SW2 SW3
1.23
Vdc 6 K
1 K
SW1
SW1, 2, & 3
shown in
"Fault" position
Input Overvoltage (See Note 1)
Overtemperature
Module Faults
1 Not applicable for 300 Vdc input family
1 M
Figure 3 PC/SC module alarm logic.
Figure 6 Isolated on-state indicator.
2–20 ms typ.
Fault
SC
PC
1.23 V
5.7 V
40 μs typ.
Figure 5 PC/SC module alarm timing.
Figure 7 Secondary side on-state indicator.
PRIMARY CONTROL - PC PIN
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715 28 V Maxi Family Rev. 2.2 Page 8 of 11
Set your site on VICOR at vicorpower.com
Parallel Operation
The PR pin supports paralleling for increased power with N+1
(N+M) redundancy. Modules of the same input voltage, output
voltage, and power level will current share if all PR pins are
suitably interfaced.
Compatible interface architectures include the following:
AC coupled single-wire interface. All PR pins are connected
to a single communication bus through 0.001 µF (500 V)
capacitors. This interface supports current sharing and is fault
tolerant except for the communication bus. Up to three
converters may be paralleled by this method. See Figure 9.
Transformer coupled interface. For paralleling four or more
converters a transformer coupled interface is required. See
Figure 10.
For details on parallel operation please refer to the
Design Guide & Applications Manual for Maxi, Mini, Micro Family.
Figure 9 AC coupled single-wire interface.
* See Maxi, Mini, Micro Design Guide.
+IN
PC
PR
–IN
+IN
PC
PR
–IN
Module 2
Module 1
T1
T2
+
0.2 µF
0.2 µF
Parallel
Bus
4.7 nF
4.7 nF
4.7 nF
4.7 nF
Z1*
Z1*
Figure 10 Transformer-coupled interface.
PARALLEL BUS - PR PIN
Output Voltage Programming
The output voltage of the converter can be adjusted or
programmed via fixed resistors, potentiometers or voltage
DACs. See Figure 8.
Figure 8 Output voltage trim down and trim up circuit.
–OUT
+S
SC
Error Amplifier
+
0.033 uF
+
-S
+OUT
Load
Rd
Trim Down
Ru
Trim Up
1.23 V
1 kΩ
100 Ω typ.
1,000 Vout
Vnom – Vout
Rd (ohms) =
1,000 (Vout –1.23) Vnom
1.23 (Vout – Vnom)
RU (ohms) = – 1,000
Trim Down
1. This converter is not a constant power device – it has a
constant current limit. Hence, available output power is
reduced by the same percentage that output voltage is
trimmed down. Do not exceed maximum rated output current.
2. The trim down resistor must be connected between the SC
and -S pins. Do not bypass the SC pin directly with a
capacitor.
Trim Up
1. The converter is rated for a maximum delivered power. To
ensure that maximum rated power is not exceeded, reduce
maximum output current by the same percentage increase in
output voltage.
2. The trim up resistor must be connected between the SC
and +S pins. Do not bypass the SC pin directly with a
capacitor.
3. Do not trim the converter above maximum trim range
(typically +10%) or the output over voltage protection
circuitry may be activated.
SECONDARY CONTROL - SC PIN
Trim resistor values calculated automatically:
On-line calculators for trim resistor values are available on the
vicor website at:
asp.vicorpower.com/calculators/calculators.asp?calc=1
Resistor values can be calculated for fixed trim up, fixed trim
down and for variable trim up or down.
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715 28 V Maxi Family Rev. 2.2 Page 9 of 11
Set your site on VICOR at vicorpower.com
Module 2
Module 1
Module N+1
+OUT
+S
SC
–S
–OUT
Load
+S
–S
+OUT
+S
SC
–S
–OUT
+OUT
+S
SC
–S
–OUT
Figure 11 N+1 module array output connections.
The +Out andOut power buses should be designed to
minimize and balance parasitic impedance from each
module output to the load.
The +Sense pins must be tied together to form a
+Sense bus. This must be Kelvin connected to +Out
at a single point. The –Sense pins should be tied
together to form a –Sense bus. This must be Kelvin
connected to –Out at a single point.
At the discretion of the power system designer,
a subset of all modules within an array may be
configured as slaves by connecting SC to –S.
OR’ing diodes may be inserted in series with the
+Out pins of each module to provide module
output fault tolerance.
The +Sense and -Sense leads should be routed in close
proximity to each other on the printed circuit board. If
wires are used to connect the converters on a PCB to
an external load, the Sense leads should be twisted
together to reduce noise pickup.
Designator Description Finish Notes
(None) Short Tin/Lead Requires in-board, mounting
L Long Tin/Lead On-board mounting for 0.065" boards
S Short ModuMate Gold SurfMate or in-board socket mounting
N Long ModuMate Gold On-board socket mounting
F Short RoHS Gold Select for RoHS compliant in-board solder, socket, or SurfMate mounting
G Long RoHS Gold Select for RoHS compliant on-board solder or socket mounting
* Pin style designator follows the “B” after the output power and precedes the baseplate designator.
Ex.
V48A12T500BN2
— Long ModuMate Pins
PARALLEL BUS OUTPUT
PIN STYLES*
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715 28 V Maxi Family Rev. 2.2 Page 10 of 11
Set your site on VICOR at vicorpower.com
ALL MARKINGS
THIS SURFACE
PINS STYLES
SOLDER:TIN/LEAD PLATED
MODUMATE: GOLD PLATED COPPER
RoHS: GOLD PLATED COPPER
ALUMINUM
BASEPLATE
0.195
4,95
1.400*
35,56
1.000*
25,40
0.700*
17,78
0.400*
10,16
3.844**
97,64
4.200*
106,68
1.790**
45,47
0.06
1,5
R (4X) 0.178
4,52
56789
1234
±0.003
±0,08
* DENOTES TOL =
PLATED
THRU HOLE
DIA
PCB THICKNESS 0.062 ±0.010
1,57 ±0,25
SHORT PIN STYLE
0.094 ±0.003
2,39 ±0,08
0.194 ±0.003
4,93 ±0,08
LONG PIN STYLE
0.094 ±0.003
2,39 ±0,08
0.194 ±0.003
4,93 ±0,08
INBOARD
SOLDER
MOUNT
0.43
10,9
ONBOARD
SOLDER
MOUNT
(7X)
(2X)
0.53
13,5
**PCB WINDOW
Converter Pins
No. Function Label
1 +In +
2Primary PC
Control
3 Parallel PR
4 –In
5 –Out
6 –Sense –S
7Secondary SC
Control
8 +Sense +S
9 +Out +
FOR SOLDERING METHODS AND PROCEDURES
PLEASE REFER TO THE MAXI, MINI, MICRO
DESIGN GUIDE.
MECHANICAL DRAWINGS
Figure 12 Module outline
Figure 13 PCB mounting specifications
Unless otherwise specified,
dimensions are in inches
mm
Decimals Tol. Angles
0.XX ±0.01
±0,25 ±1°
0.XXX ±0.005
±0,127
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715 28 V Maxi Family Rev. 2.2 08/12
Set your site on VICOR at vicorpower.com
Vicor’s comprehensive line of power solutions includes high density AC-DC and DC-DC modules and
accessory components, fully configurable AC-DC and DC-DC power supplies, and complete custom
power systems.
Information furnished by Vicor is believed to be accurate and reliable. However, no responsibility is assumed by Vicor for its use. Vicor makes no
representations or warranties with respect to the accuracy or completeness of the contents of this publication. Vicor reserves the right to make
changes to any products, specifications, and product descriptions at any time without notice. Information published by Vicor has been checked and
is believed to be accurate at the time it was printed; however, Vicor assumes no responsibility for inaccuracies. Testing and other quality controls are
used to the extent Vicor deems necessary to support Vicor’s product warranty. Except where mandated by government requirements, testing of all
parameters of each product is not necessarily performed.
Specifications are subject to change without notice.
Vicor’s Standard Terms and Conditions
All sales are subject to Vicor’s Standard Terms and Conditions of Sale, which are available on Vicor’s webpage or upon request.
Product Warranty
In Vicor’s standard terms and conditions of sale, Vicor warrants that its products are free from non-conformity to its Standard Specifications (the
“Express Limited Warranty”). This warranty is extended only to the original Buyer for the period expiring two (2) years after the date of shipment
and is not transferable.
UNLESS OTHERWISE EXPRESSLY STATED IN A WRITTEN SALES AGREEMENT SIGNED BY A DULY AUTHORIZED VICOR SIGNATORY, VICOR DISCLAIMS
ALL REPRESENTATIONS, LIABILITIES, AND WARRANTIES OF ANY KIND (WHETHER ARISING BY IMPLICATION OR BY OPERATION OF LAW) WITH
RESPECT TO THE PRODUCTS, INCLUDING, WITHOUT LIMITATION, ANY WARRANTIES OR REPRESENTATIONS AS TO MERCHANTABILITY, FITNESS FOR
PARTICULAR PURPOSE, INFRINGEMENT OF ANY PATENT, COPYRIGHT, OR OTHER INTELLECTUAL PROPERTY RIGHT, OR ANY OTHER MATTER.
This warranty does not extend to products subjected to misuse, accident, or improper application, maintenance, or storage. Vicor shall not be liable
for collateral or consequential damage. Vicor disclaims any and all liability arising out of the application or use of any product or circuit and assumes
no liability for applications assistance or buyer product design. Buyers are responsible for their products and applications using Vicor products and
components. Prior to using or distributing any products that include Vicor components, buyers should provide adequate design, testing and operat-
ing safeguards.
Vicor will repair or replace defective products in accordance with its own best judgment. For service under this warranty, the buyer must contact
Vicor to obtain a Return Material Authorization (RMA) number and shipping instructions. Products returned without prior authorization will be
returned to the buyer. The buyer will pay all charges incurred in returning the product to the factory. Vicor will pay all reshipment charges if the
product was defective within the terms of this warranty.
Life Support Policy
VICOR’S PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT DEVICES OR SYSTEMS WITHOUT THE EXPRESS
PRIOR WRITTEN APPROVAL OF THE CHIEF EXECUTIVE OFFICER AND GENERAL COUNSEL OF VICOR CORPORATION. As used herein, life support
devices or systems are devices which (a) are intended for surgical implant into the body, or (b) support or sustain life and whose failure to perform
when properly used in accordance with instructions for use provided in the labeling can be reasonably expected to result in a significant injury to the
user. A critical component is any component in a life support device or system whose failure to perform can be reasonably expected to cause the
failure of the life support device or system or to affect its safety or effectiveness. Per Vicor Terms and Conditions of Sale, the user of Vicor products
and components in life support applications assumes all risks of such use and indemnifies Vicor against all liability and damages.
Intellectual Property Notice
Vicor and its subsidiaries own Intellectual Property (including issued U.S. and Foreign Patents and pending patent applications) relating to the prod-
ucts described in this data sheet. No license, whether express, implied, or arising by estoppel or otherwise, to any intellectual property rights is
granted by this document. Interested parties should contact Vicor's Intellectual Property Department.
Vicor Corporation
25 Frontage Road
Andover, MA, USA 01810
Tel: 800-735-6200
Fax: 978-475-6715
email
Customer Service: custserv@vicorpower.com
Technical Support: apps@vicorpower.com