IPT Integrated Pressure Transducer
FULL SCALE PRESSURE RANGE
DIGITAL INTERFACE VOLTAGE
Performance Specifications (1)
Total Error Band: (from -40 to 85ºC)
±0.04%FS absolute
±0.10%FS gauge, differential
±0.20%FS 1 psi gauge
Temperature Range:
Operating -40 to 85ºC (-40 to 185ºF)
Storage: -55 to 125ºC (-67 to 257ºF)
Long Term Stability:
0.025% FS max per year
Mechanical Specifications
Pressure Ranges and Type:
See Ordering Information at right
Pressure Units: PSI(2)
Media Compatibility: Suitable for non-condensing,
non-corrosive, and non-combustible gases.
Weight(3): ~8.0 grams (absolute)
~9.7 grams (gauge, differential)
Electrical Specifications
Output:
24-bit pressure value
16-bit temperature value
256 x 8 EEPROM configuration
Power Requirements:
Supply Voltage: 4 to 12 VDC
Current Consumption:
6 mA typical, 7.5 mA max
Interface: 3.3V SPI (mode 1,1) SCLK ≤5 Mhz
Update Rate: 166 samples/second
Overpressure: 3x FS
Burst Pressure: 3x FS
Mechanical Shock: DO-160E Section 7.0,
Category A, Figure 7.2, Operational Standard
Thermal Shock: Storage Temperature Cycling per
JESD22-104, Section 5.0: -55ºC to +125ºC
Vibration: DO-160E Section 8, Category H,
Aircraft Type 2, Aircraft Zones 1 & 2
RoHS Compliant (2002/05/EC): Yes
Honeywell Aerospace
Honeywell International Inc.
12001 Highway 55
Plymouth, MN 55441
www.honeywell.com
ADS-14184
December 2010
©2010 Honeywell International Inc.
(1) Total Error is the sum of worst case linearity, repeatability, hysteresis, thermal effects, and calibration errors
over the operating temperature range. Accuracy is only achieved after applying the correction coefficients and
algorithm as shown in section 3.2. of Product Specification (FS = Full Scale). For total error calculations of
differential units, “Full Scale” is the pressure difference between the minimum and maximum pressures. For
example, full scale for a 1 psid PPT is 2 psi (-1 to +1 psi). Pressure range 1psi gauge has total error of ±0.20%
FS. (2) After applying the correction coefficients stored in EEPROM, the resultant pressure reading is
expressed in PSI (pounds per square inch). (3) Not including mounting hardware. (4) Demonstration kit includes
RS-232 Cable, Demo Board, AC adapter, MS Windows Software, and User’s Manual.