SLUS503B – MARCH 2002 – REVISED AUGUST 2002
  
 
1
www.ti.com
FEATURES
Enables Hot Swap in CompactPCI High
Availability Systems
Programmable Current Slew Rate
Power Supply Sequencing
Sense Resistors Set Peak Current (IMAX)
Overcurrent Circuit Breaker at 2× IMAX
Precharge Output
HEALTHY# Signal of Board Power Good
BD_SEL# Signal for Peripheral Enable
On-Chip Charge Pump
Low Sleep Mode Current
Undervoltage Lockout (UVLO)
Minimal External Parts Count
24-pin TSSOP Package
DESCRIPTION
The TPS2345 CompactPCI Hot Swap Power
Manager (HSPM) provides highly-integrated
supply control of three positive (3.3-V, 5-V, and
12-V) and one negative (–12-V) supply rails with
a minimum number of external components. A
linear current amplifier (LCA) in each of the four
device channels provides closed-loop control of
load current during insertion and extraction
events. This allows the designer to configure the
plug-in card’s maximum inrush slew rate and
magnitude according to the requirements of the
CompactPCI Hot Swap Specification
PICMG 2.1.
CompactPCI PLUG-IN MODULE
BACK-END POWER PLANES
R7
1.2 k
R6
10 k
C5
0.33 µF
C4
0.1 µF
C3
0.1 µF
C2
0.1 µF
C1
0.1 µF
R2
3 m
C6
0.1 µF
R3
2.5 m
R4
0.25 R5
10 k
R1
0.025
R8
10
CompactPCI BACKPLANE
EARLY
VIO
12V
5V
GND
3.3 V
–12 V
12 V
5 V
3.3 V
–12 V
PCI DEVICE
AD[00]
AD[XX:01]
CS1
VIN1
BD_SEL#
HEALTHY#
RGND
VIN4 CS4
GATE1 VS1 VIN2
PRECHG
CS2 GATE2
VS2
CPUMP
CPGND
VS3
GATE3
VIN3
IRAMP
CS3VS4GATE4
TPS2345 AGND
AD[00]
AD[XX:01]
Q1
Q2
Q3
Q4
EXAMPLE SIGNAL LINE
D2
D1
MAZ3140
RP
CompactPCI Bus
UDG–01128
TYPICAL APPLICATION
BD_SEL#
HEALTHY#
MAZ3140
PICMG, CompactPCI, and the PICMG and CompactPCI logos are registered trademarks of the PCI Industrial Computer Manufacturers Group.
Copyright 2002, Texas Instruments Incorporated        
         
       
   

SLUS503B MARCH 2002 REVISED AUGUST 2002
2www.ti.com
description (continued)
Fully programmed sequencing control ramps the back-end plane voltages in order, and during shutdown from
a healthy state, turns off the back-end supplies in the reverse order. In addition, electronic circuit breakers
provide continuous protection for the system supplies during the plug-in operation. The control and status pins
can interface directly to the back-plane BD_SEL# and HEALTHY# signals. A precharge pin (PRECHG) provides
a 1-V bias supply for the I/O signals.
absolute maximum ratings over operating free-air temperature (unless otherwise noted)
Input voltage range, VIN1, VIN2, VIN3, BD_SEL#, HEALTHY#, PRECHG 0.3 V to 15 V. . . . . . . . . . . . . . . .
VS1, VS2, VS3, CS1, CS2, CS3 0.3 V to VIN +0.3 V of corresponding channel. . . . .
CPUMP, GATE1, GATE2, GATE3 0.3 V to 25 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
VIN4, VS4, GATE4, CS4 15 V to 0.3 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
IRAMP 0.3 V to VI(VIN1) +0.3 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Operating junction temperature range, TJ55°C to 150°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Storage temperature range, Tstg 65°C to 150°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Lead temperature soldering 1,6 mm (1/16 inch) from case for 10 seconds 300°C. . . . . . . . . . . . . . . . . . . . . . .
Stresses beyond those listed under absolute maximum ratings may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under recommended operating conditions is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability. All voltages are with respect to GND.
Currents are positive into, and negative out of the specified terminal.
AVAILABLE OPTIONS
T
PACKAGED DEVICES
TATSSOP (PW)
40C to 85C TPS2345PW
The PW package is available taped and reeled. Add TR suffix to device type
(e.g. TPS2345PWTR) to order quantities of 2,000 devices per reel and 90
units per tube.
1
2
3
4
5
6
7
8
9
10
11
12
24
23
22
21
20
19
18
17
16
15
14
13
GATE1
VS1
VIN1
CS1
IRAMP
BD_SEL#
RGND
PRECHG
CS3
VIN3
VS3
GATE3
GATE2
VS2
VIN2
CS2
CPUMP
CPGND
AGND
HEALTHY#
CS4
VIN4
VS4
GATE4
PW PACKAGE
(TOP VIEW)

SLUS503B MARCH 2002 REVISED AUGUST 2002
3
www.ti.com
electrical characteristics VI(VIN1) = 12 V, VI(VIN2) = 5 V, VI(VIN3) = 3.3 V, VI(VIN4) = 12 V,
TA = 40C to 85C (unless otherwise noted)
input supply
PARAMETER TEST CONDITIONS MIN TYP MAX UNIT
ICC1 Supply current, VIN1 6 8
ICC2 Supply current, VIN2 1 2
ICC3 Input current, VIN3 0.5 1
mA
ICC4 Input current, VIN4 1.5 3mA
ICC1(SLP) Sleep mode current, VIN1 VI(BD_SEL#) = 5 V 0.5
ICC2(SLP) Sleep mode current, VIN2 VI(BD_SEL#) = 5 V 1
ICC3(SLP) Sleep mode current, VIN3 VI(BD_SEL#) = 5 V 100
A
ICC4(SLP) Sleep mode current, VIN4 VI(BD_SEL#) = 5 V 400 µA
charge pump
PARAMETER TEST CONDITIONS MIN TYP MAX UNIT
VO(MAX) Maximum output voltage IO(CPUMP) = 25 µA 17 23 V
ISOURCE Peak output current VO(CPUMP) = 15 V 120 µA
ZOCharge pump source impedance 1V
ǒIO (CPUMP+17 V)Ǔ*ǒIO (CPUMP+16 V)Ǔ200 k
precharge output
PARAMETER TEST CONDITIONS MIN TYP MAX UNIT
VO(PCHG)1 Output voltage VI(VIN2) = 4 V, VI(VIN1/3/4) = 0 V 0.9 1 1.1
VO(PCHG)2 Output voltage, sourcing VI(VIN2) = 4 V, VI(VIN1/3/4) = 0 V,
IO(PRECHG) = 5 mA 0.8 1 1.2 V
VO(PCHG)3 Output voltage, sinking VI(VIN2) = 4 V, VI(VIN1/3/4) = 0 V,
IO(PRECHG) = 5 mA 0.8 1 1.2
V
tSTART Startup time VI(VIN2) = 4 V, VI(VIN1/3/4) = 0 V 200 µs
linear current amplifiers 1, 2, 3
PARAMETER TEST CONDITIONS MIN TYP MAX UNIT
VMAX1 IMAX sense voltage (VIN1 CS1) 16 20 24
VMAX2 IMAX sense voltage (VIN2 CS2) 17 20 23 mV
VMAX3 IMAX sense voltage (VIN3 CS3) 17 20 23
mV
IPK Output peak current 25 5
ISINK Output current sink 0.2 10 mA
IFAULT Output current sink Fault shutdown 150
mA
VOL Low-level output voltage Fault shutdown, IO(GATEx) = 10 mA 0.5
V
VOH High-level output voltage IO(GATEx) = 4 µA VCPUMP1V
linear current amplifier 4
PARAMETER TEST CONDITIONS MIN TYP MAX UNIT
VMAX4 IMAX sense voltage (VIN4 CS4) 75 150 225 mV
IOL1 Output leakage current Fault shutdown 10 10
A
IOL2 Output leakage current Sleep mode 10 10 µA

SLUS503B MARCH 2002 REVISED AUGUST 2002
4www.ti.com
electrical characteristics VI(VIN1) = 12 V, VI(VIN2) = 5 V, VI(VIN3) = 3.3 V, VI(VIN4) = 12 V,
TA = 40C to 85C (unless otherwise noted) (continued)
overcurrent comparators 1, 2, 3
PARAMETER TEST CONDITIONS MIN TYP MAX UNIT
VOC1 Overcurrent threshold voltage
(VIN1 CS1) 34 45 56
VOC2 Overcurrent threshold voltage
(VIN2 CS2) 29 40 51 mV
VOC3 Overcurrent threshold voltage
(VIN3 CS3) 29 40 51
tRResponse time 1 5 µs
overcurrent comparator 4
PARAMETER TEST CONDITIONS MIN TYP MAX UNIT
VOC4 Overcurrent threshold voltage
(VIN4 CS4) relative to VMAX4 50 225 mV
tRResponse time 1 5 µs
undervoltage (UV)
PARAMETER TEST CONDITIONS MIN TYP MAX UNIT
VUV1 Channel 1 undervoltage limit 10.37 10.80 11.23
VUV2 Channel 2 undervoltage limit 4.22 4.40 4.58
V
VUV3 Channel 3 undervoltage limit 2.78 2.90 3.02 V
VUV4 Channel 4 undervoltage limit -11.23 -10.80 -10.37
overvoltage (OV)
PARAMETER TEST CONDITIONS MIN TYP MAX UNIT
VOV1 Channel 1 overvoltage limit 12.77 13.20 13.63
VOV2 Channel 2 overvoltage limit 5.38 5.60 5.82
V
VOV3 Channel 3 overvoltage limit 3.55 3.70 3.85 V
VOV4 Channel 4 overvoltage limit -13.63 -13.20 -12.77
IRAMP output
PARAMETER TEST CONDITIONS MIN TYP MAX UNIT
ICHG Source current, charging VO(IRAMP) = 0.5 V 46 58 68
A
IDSG Sink current, discharging VO(IRAMP) = 0.5 V 1.3 1.8 2.5 µA
undervoltage lockout (UVLO)
PARAMETER TEST CONDITIONS MIN TYP MAX UNIT
VUVLOLVIN1 UVLO, input rising 2.1 2.4 2.9
VUVLOHVIN1 UVLO, input falling VI
(
VIN2
)
= VI
(
VIN3
)
= VI
(
VIN4
)
= 0 V 1.90 2.25 2.70 V
VHYS VIN1 UVLO hysteresis
VI(VIN2)
VI(VIN3)
VI(VIN4)
0
V
0.05
V
BD_SEL# input
PARAMETER TEST CONDITIONS MIN TYP MAX UNIT
VIL Low-level input voltage 0.8
V
VIH High-level input voltage 2V
IIH High-level input leakage current VI(BD_SEL#) = 5 V 50 µA

SLUS503B MARCH 2002 REVISED AUGUST 2002
5
www.ti.com
electrical characteristics VI(VIN1) = 12 V, VI(VIN2) = 5 V, VI(VIN3) = 3.3 V, VI(VIN4) = 12 V,
TA = 40C to 85C (unless otherwise noted) (continued)
HEALTHY# output
PARAMETER TEST CONDITIONS MIN TYP MAX UNIT
IOH Highlevel output (leakage) current VI(BD_SEL#) = 5 V, VOH = 5 V 1µA
VOL Low-level output voltage VI(BD_SEL#) = 0 V, ISINK = 0.1 mA 0.5 V
IOL Low-level output (sink) current VI(BD_SEL#) = 0 V, VOL = 0.5 V 4 10 mA
Terminal Functions
TERMINAL
I/O
DESCRIPTION
NAME NO. I/O DESCRIPTION
AGND 18 I Analog ground
BD_SEL# 6 I Logic low enable input for back-end power
CPGND 19 I Charge pump ground
CPUMP 20 I/O Charge pump resevoir capacitor connection
CS1 4 I Channel 1 (12-V) current sense input
CS2 21 I Channel 2 (5-V) current sense input
CS3 9 I Channel 3 (3.3-V) current sense input
CS4 16 I Channel 4 (12-V) current sense input
GATE1 1 O Gate drive for Channel 1 (12-V) external pass FET
GATE2 24 O Gate drive for Channel 2 (5-V) external pass FET
GATE3 12 O Gate drive for Channel 3 (3.3V) external pass FET
GATE4 13 O Gate drive for Channel 4 (12V) external pass FET
HEALTHY# 17 O Open drain output asserted low for back-end power good
IRAMP 5 O Current ramp programming pin
PRECHG 8 O Bias supply of 1V for bus signal precharge
RGND 7 I Reference ground
VIN1 3 I Channel 1 supply (12-V) input voltage sense
VIN2 22 I Channel 2 supply (5-V) input voltage sense
VIN3 10 I Channel 3 supply (3.3-V) input voltage sense
VIN4 15 I Channel 4 supply (12-V) input voltage sense
VS1 2 I 12-V supply back-end voltage sense
VS2 23 I 5-V supply back-end voltage sense
VS3 11 I3.3-V supply back-end voltage sense
VS4 14 I 12-V supply back-end voltage sense
DISSIPATION RATING TABLE
PACKAGE TA 25CDERATING FACTOR TA = 85C
TSSOP (PW) 800 mW 10 mW/C200 mW

SLUS503B MARCH 2002 REVISED AUGUST 2002
6www.ti.com
pin descriptions
AGND: Analog ground reference for the device.
BD_SEL#: Logic low enable input for back-end power. In the CompactPCI application, this pin ties to the
shortpin BD_SEL# input to the plug-in slot. When the input supplies are above the device minimums, and this
pin is asserted low the TPS2345 begins the sequential rampup of the back-end supplies. Pulling this input high
(>2 V) turns off power to the back-end planes, and puts the TPS2345 into low-power sleep mode.
CPGND: Charge pump ground pin for the device.
CPUMP: Charge pump resevoir capacitor connection. An external capacitor of value 0.1 µF to 1 µF must be
connected between this pin and CPGND. The capacitor provides charge storage for the internal charge pump
for gate drive of the four external N-channel FETs.
CS1, CS 2 , C S 3 : These pins tie to the load side of the Channel 1, 2, and 3 current sense resistors, respectively.
They are used in conjunction with the VIN1, VIN2 and VIN3 inputs to provide load current magnitude information
to each of the positive rail LCAs.
CS4: This pin ties to the more positive side of the Channel 4 current sense resistor (common with the pass FET
source). It is used in conjunction with the VIN4 input to provide Channel 4 current magnitude information to the
negative rail LCA.
GATE1, GATE2, GATE3, GATE4: Gate drive outputs for the Channel 1 through Channel 4 pass FETs,
respectively. The gates are driven according to the supply voltage, enable, sequence programming and load
current conditions of the add-in board.
HEALTHY#: Open-drain output asserted low to signal a back-end power good condition. In the CompactPCI
application, this signal is an indication of the boards suitablility to be connected to the CompactPCI bus. The
output is false when back-end power is not enabled, if any of the back-end voltage is not within the
factory-programmed tolerances of the undervoltage and overvoltage comparators, or as a result of an
overcurrent indication on any supply controller, or a fault time-out on any supply during linear ramp-up.
IRAMP: Current ramp programming pin. A capacitor connected between this pin and ground determines the
maximum slew rate of the load current during ramp-up and ramp-down of the three positive back-end voltages.
This same capacitor is also used to establish the time limit for ramping each of the supply outputs.
PRECHG: Bias supply of 1 V for bus signal precharge. During plug-in insertion events, this output provides bias
supply to precharge the bus signal lines according to the requirements of the CompactPCI Hot Swap
specification.
RGND: Reference ground input for the device.
VIN1: Channel 1 supply (12-V) input voltage sense. This pin is connected to the 12-V power supply input to
the add-in card. The supply potential is tested against the undervoltage limits prior to ramping voltage to the
back-end 12-V plane. The input supply also serves as the reference potential for the internally generated current
limit (IMAX) reference of the Channel 1 LCA. This pin also serves as the VCC supply for the TPS2345.
VIN2: Channel 2 supply (5-V) input voltage sense. This pin is connected to the 5-V power supply input to the
add-in card. The supply potential is tested against the undervoltage limits prior to ramping voltage to the
back-end 5-V plane. The input supply also serves as the reference potential for the internally generated current
limit (IMAX) reference of the Channel 2 LCA. This pin also serves as the supply input for the precharge bias
output.
VIN3: Channel 3 supply (3.3-V) input voltage sense. This pin is connected to the 3.3-V power supply input to
the add-in card. The supply potential is tested against the undervoltage limits prior to ramping voltage to the
back-end 3.3-V plane. The input supply also serves as the reference potential for the internally generated
current limit (IMAX) reference of the Channel 3 LCA.

SLUS503B MARCH 2002 REVISED AUGUST 2002
7
www.ti.com
pin descriptions (continued)
VIN4: Channel 4 supply (12-V) input voltage sense. This pin is connected to the 12-V power supply input
to the add-in card. The supply potential is tested against the undervoltage limits prior to ramping voltage to the
back-end 12-V plane. The input supply also serves as the reference potential for the internally generated
current limit (IMAX) reference of the Channel 4 LCA.
VS1, VS2, VS3: Voltage sense inputs for the positive back-end power busses. These pins connect to the source
nodes (load side) of the external pass FETs. After the programmed voltage ramp period for each supply, these
inputs are monitored to verify that the load voltages remain within the specified tolerances.
VS4: Voltage sense input for the negative back-end power bus. This pin connects to the drain (load side) of
the Channel 4 external pass FET. After the programmed voltage ramp period for the negative supply, this input
is monitored to verify that the load voltage remains within the specified tolerance.
functional overview
When an add-in CompactPCI printed circuit board (PCB) is inserted into a live chassis slot, the discharged
supply bulk capacitance on the board can draw huge transient currents from the system supplies. Limited only
by the ESR of the bulk capacitors and the impedance of the interconnect, these transients can reach suf ficient
magnitude to cause immediate damage to connector pins, PCB etch and plug-in and supply components, or
cause latent defects reducing long-term reliability. In addition, current spikes can cause glitches on the power
busses, causing other boards in the system to reset.
The TPS2345 is designed for use with the connector pin staging and insertion/extraction processes defined in
the CompactPCI Hot Swap Specification, to enable full hot-swap capability in CompactPCI add-in cards.
Nchannel MOSFETs in series with each supply input provide isolation between the early power planes and
the back-end power planes during insertion and extraction events. Low ohmic-value sense resistors between
each input and pass MOSFET feed back current information to the device. The TPS2345 uses load current
sensing along with the peripheral slot enable command, BD_SEL#, to determine the appropriate gate drive
status for each of the four pass MOSFETs. In this manner, the device provides for the controlled application
of power to and removal from the back-end planes during hot swap.
When the add-in PCB is inserted into the slot, the long 5-V, 3.3-V and GND power pins make contact first (see
typical application diagram). At this stage of the insertion process, the TPS2345 precharge circuitry becomes
active, and biases the I/O pins to a nominal 1.0 V. Next, the medium length pins make contact, which includes
the 12-V, 12-V supplies, and the majority of the 5-V and 3.3-V supply pins. The TPS2345 derives VCC power
from the 12-V supply; however, the pull-up on the BD_SEL# input pin causes the device to maintain pull-downs
on the four gate pins, keeping the pass MOSFETs off. The short BD_SEL# pin is one of the last pins to mate;
at that point a logic low on the signal starts the turn-on of power to the back-end loads.
During a ramp-up sequence, the four supply inputs are validated against the pre-programmed undervoltage
(UV) and overvoltage (OV) thresholds. As each positive voltage load is enabled, current to the load is ramped
at a user-programmable rate, easily set by a capacitor on the current ramp control pin, IRAMP. The supplies
are sequenced up in the following order: 12-V, 5-V, 3.3-V and 12-V. The ramp of supply current on each
channel is limited to a maximum value, herein referred to as IMAX. The IMAX limit is individually selectable for
each channel, by selecting the appropriate value of the sense resistor. If the IMAX current level is attained on
any channel during an insertion, charging of that channels input bulk capacitance completes at that current limit,
as required.

SLUS503B MARCH 2002 REVISED AUGUST 2002
8www.ti.com
functional overview (continued)
As each back-end voltage is ramped, its level is validated to ensure it is within the established UV and OV
tolerances at the expiration of a programmable time period, protecting against start-up into faulted loads. The
same capacitor at the IRAMP pin which sets the current ramp rate is also used to establish this ramp-up time
limit. If all four supplies successfully reach a known good state, the HEALTHY# output signal is pulled low to
allow enumeration of the add-in card.
To protect the backplane power bus, the TPS2345 provides an electronic circuit breaker that trips upon detecting
an overcurrent event. The detection threshold of an overcurrent event is internally set to approximately two
times (2x) IMAX. The 12-V channel also includes a circuit breaker function; its trip threshold is always a
minimum of 50 mV above the current-limit sense voltage. If any channel trips the circuit breaker, all supply
outputs are rapidly turned off, and remain latched off. Also, the HEALTHY# output becomes high-impedance.
The TPS2345 can be reset by cycling either the BD_SEL# input or power to the device.
The low, 20-mV (150 mV on the 12-V channel) nominal sense voltage limit allows the use of low-value sense
resistors, or for high-current applications, the use of PC board copper trace. This helps minimize the insertion
loss across the hot swap interface. Further insertion loss reduction is achieved via the on-chip charge pump,
which ensures maximum gate overdrive on each of the three external pass MOSFETs on the positive supply
channels. This feature helps users obtain lower RDS(on) characteristics with their preferred N-channel
MOSFETs.
Under a normal PC board shutdown event, the TPS2345 also turns of f power in a controlled manner. To initiate
a shutdown, BD_SEL# is brought to a logic high during a HEALTHY# state (outputs on and no faults present).
The supply outputs are then sequentially ramped off in the reverse order of the ramp-up sequence. After all
supply outputs are off, the TPS2345 goes into a low-current sleep mode.

SLUS503B MARCH 2002 REVISED AUGUST 2002
9
www.ti.com
detailed description
The primary circuit blocks of the TPS2345 include internal supply generation, a charge pump, a state machine,
programmable ramp generator , precharge circuitry, and a ROM data cell. In addition, each of the four channels
contains a gate control block which includes the linear control amplifier (LCA), programmable current source,
and the voltage sense circuitry (see Figure 1). The gate drive blocks are virtually identical, except that the
Channel 4 block, controlling the negative voltage channel, adds some scaling and level shift circuitry to adjust
the polarity of the sense signals to that of the internal circuitry.
+
1V
+
2.5V
SUPPLY
SECTION CHARGE
PUMP
CPOK
UVLO
VIN1
UVOV1
LEVEL[15:0]
IRAMP
VIN2
STATE
MACHINE
UVOV[4:1]
100 µS
ROM
DATA
PRE
CHARGE
+
+
VIMAX3 LCA/
VSNS3 VIMAX4
LS
+
+
LCA/
VSNS4
VIMAX2
+
+
LCA/
VSNS2
VIMAX1
+
+
LCA/
VSNS1
EN1
EN2
EN3
EN4
/FLT
OC[4:1]
UVLO
CPOK
EN
ORD[8:0]FS
VS1
OC1
UVOV3
OC3
UVOV2
OC2
UVOV4
OC4
VIN2
VA
VA
EN1 EN2
EN3 EN4
BD_SEL#
HEALTHY#
VIN1
VIN3
VIN4
3
12 11 148 1613
15
5
22
23 24 212024 1
6
17
10
VS2
VS4VS3
GATE1CS1 CS2
CS4CS3
GATE2
GATE4GATE3
19
7
18
/CHG
RGND
AGND PRECHG
CPGND CPUMP
+
DAC
RAMP
GENERATOR
3
UP
CH_SEL[4:1]
9
MUX
Figure 1. TPS2345 block diagram
The supply generation block contains voltage regulators and references to generate the various bias voltages
used internally by the TPS2345. An undervoltage lockout (UVLO) function is used to ensure proper device
turn-on once the VIN1 input has attained the UVLO threshold of about 2.5 V. In addition, an on-chip charge pump
steps up t h e V I N 1 i nput to generate the high voltage used by the LCAs to drive the pass MOSFET gates. Burst
regulation of the charge pump limits the output to about 20.5 V (peak), with about a 1-V hysteresis. During
steady-state load operation, sufficient gate overdrive is ensured to fully enhance the external MOSFETs, while
not exceeding the typical 20-V VGS rating of common N-channel MOSFETs, even on the low-voltage channels.
The state machine block contains the logic to control the ramp-up and ramp-down sequencing, ramp generator
operation, and fault management. It uses voltage and current monitor outputs, along with the device enable
status and programmed order information to determine which channel is to be acted on, whether ramp-up,
ramp-down or steady-state operation is required, and the present healthy or faulted states of the back-end
supplies. A n o m inal 100µS digital filter is applied to the BD_SEL# input to help protect against false triggering
in systems not implementing hardware connection control. The filter acts on both high-to-low and low-to-high
transitions of the enable input.

SLUS503B MARCH 2002 REVISED AUGUST 2002
10 www.ti.com
detailed description (continued)
The ramp generator consists of a series of multiplexers feeding a digital-to-analog converter (DAC) circuit which
sets the magnitude of an internal current source. When active, the current source is used to establish a constant
value source or sink current at the IRAMP pin. This current is used to alternately charge and discharge a
capacitor connected between IRAMP and ground, generating a series of sawtooth timing pulses. During turn-on
of the back-end voltages, the capacitor is charged with a 58-µA current, then subsequently discharged with a
1.8-µA load. A comparator in the ramp generator circuit monitors the IRAMP voltage against two alternating
thresholds, such that the voltage charges up to 1.5 V and back down to 0 V. During the rising edge of this
waveform, the voltage at IRAMP is used to develop the reference threshold at the inverting input of the active
channels LCA. The other input is connected to the channels current sense (CSx) input. The LCA slews the
GATEx output to maintain the CSx pin at the reference value. Since the CSx voltage is developed as the drop
across the external sense resistor due to load current, the current to the load is therefore ramped at a linear rate
set by the dV/dt on the IRAMP pin. Therefore, inrush slew rate limiting is easily programmed by the user with
the IRAMP capacitor , C IRAMP. For Channel 4, internal device of fsets may cause the inrush profile to deviate from
the programmed curve, particularly at initial turn-on. However, the maximum sourcing limit imposed by the
VMAX4 threshold still applies.
During a load turn-on, the current sense voltage, if required in order to fully charge the back-end plane, can track
the IRAMP waveform up to approximately 1.35 V on the IRAMP pin. If the charging current achieves that level,
the LCA reference is switched automatically to the fixed IMAX reference. Load charging then continues at that
fixed level until complete or until timer expiration, whichever occurs first. For Channels 1, 2 and 3, the IMAX level
has been set to 20 mV at the CSx pin, referenced to VINx. For Channel 4, the IMAX level is 150 mV.
The precharge circuitry is powered from the VIN2 supply input, or 5-V for cPCI systems. Therefore, when the
long pins mate during an insertion, or until they break contact during an extraction, the precharge actively biases
the bus signal lines to 1.0 V. The precharge block consists of a 1-V reference generator and a unity gain amplifier.
The amplifier provides source and sink capability up to 5 mA.
The ROM data cell sets the configuration information for the TPS2345. These parameters include the order of
channel sequencing, the magnitude of the charge and discharge currents at IRAMP, and the nominal voltage
range of each channel. This information is all pre-programmed at the factory; no programming by the user is
necessary.

SLUS503B MARCH 2002 REVISED AUGUST 2002
11
www.ti.com
detailed description (continued)
The basic functional blocks of the LCA/voltage sense circuits is shown in greater detail in Figure 2. The LCA
has as its inputs the reference voltage generated by the current sources, and the current sense input. During
a supply turn-on, it slews the pass MOSFET gate to force the load current to track the selected source. After
load charging completes, and the current decays to the nominal operating level, the LCA drives the GATEx
output to its input supply level, the charge pump output voltage.
UDG02004
+
R
LCA
OCA
OV
UV
UV
OV
R
DAC
DAC
5
5
REF_Vx
VSEL
VINx
CSx
VSx
GATEx
OCx
UVOVx
MUX
2:1
VCPUMP
VIMAX
IRAMP
10
VINX
Figure 2. Linear Control Amplifier Block
The supply voltage is monitored by the undervoltage (UV) and overvoltage (OV) comparators. A voltage
multiplexer (MUX) selects from either the input supply voltage (VINx) or the load voltage (VSx), and provides
that signal to the comparator inputs. Once the Channel 1 supply is above the UVLO threshold, and the BD_SEL#
input has been pulled low, but prior to the ramp-up of the first channel, the comparators monitor the input
supplies. Any supply outside its UV/OV window causes all pass MOSFETs to be h el d o ff. If all inputs are within
tolerance, a ramp-up sequence can start, at which time the comparator inputs are switched over to the load,
or VSx, voltages. Within the state machine, monitoring of the ORed status of the UV and OV comparators of
any channel is enabled at the turn-on of the next channel, or approximately at the leading edge of the next
IRAMP pulse.
Finally, a fast overcurrent comparator (OCA in the diagram) also monitors the CSx input. This comparator
threshold is set to approximately 2 times the current limit threshold, (2 × IMAX) for the three positive supplies.
In the event of a short-circuit or other fast overcurrent event, the OCA trips, disabling the LCA, and causing
additional gate discharge paths to be turned on for a rapid shutdown of the loads.
A 1 -µS to 2-µS filter is applied to all overcurrent and voltage faults to guard against nuisance trips. If the duration
of a fault condition on any one channel exceeds the filter length, the fault is latched, the open-drain device at
the HEALTHY# output is turned off, and all four channels are shut down.

SLUS503B MARCH 2002 REVISED AUGUST 2002
12 www.ti.com
TYPICAL CHARACTERISTICS
NORMAL TURN-ON SEQUENCE NORMAL TURN-OFF SEQUENCE
Figure 3 Figure 4
t Time 10 ms/div
IRAMP
(500 mV/div)
BD_SEL#
(5 V/div)
BE_12V
(5 V/div)
BE_5V
(5 V/div)
BE_3.3V
(5 V/div)
BE_N12V
(5 V/div)
HEALTHY#
(5 V/div)
CIRAMP = 0.01 µF
CL1 = 69 µF
CL2 = 690 µF
CL3 = 690 µF
CL4 = 69 µF
CIRAMP = 0.39 µF
CL1 = 69 µF
CL2 = 690 µF,
CL3 = 690 µF
CL4 = 69 µF
RL1 = 39
RL2 = 2.5 ,
RL3 = 1.6
RL4 = 39
t Time 5 ms/div

SLUS503B MARCH 2002 REVISED AUGUST 2002
13
www.ti.com
TYPICAL CHARACTERISTICS
Figure 5
LOAD CURRENT LINEAR RAMP
EXAMPLE: 12-V LOAD
BE_12V (5 V/div)
IRAMP (1 V/div)
12V_LOAD (200 mA/div)
CIRAMP = 0.39 µF
CLOAD1 = 169 µF
t Time 1 ms/div
.Figure 6
TURN-ON INTO A SHORT
ON BACK-END 3.3 V
CIRAMP = 0.39 µF
CLOAD1 = 69 µF
RLOAD1 = 39
CLOAD2 = 690 µF
RLOAD2 = 7
BE_3.3V: Shorted
IRAMP (1 V/div)
BE_12V (5 V/div)
BE_5V (5 V/div)
BE_3.3V
(500 mV/div)
t Time 50 ms/div
3.3V_LOAD
(2 A/div)

SLUS503B MARCH 2002 REVISED AUGUST 2002
14 www.ti.com
Figure 7
UNDERVOLTAGE FAULT RESPONSE
5-V FAULT
CLOAD1 = 69 µF
RLOAD1 = 39
CLOAD2 = 22 µF
RLOAD2 = 2.5
GATE3 (10V/div)
CLOAD3 = 690 µF
RLOAD3 = 1.6
CLOAD4 = 69 µF
RLOAD4 = 39
GATE1 (10V/div)
t Time 5 µs/div
GATE4 (10V/div)
BE_5V (2 V/div)
Figure 8
HIGH LEVEL OUTPUT VOLTAGE
vs
AMBIENT TEMPERATURE, LCA1
40 15 10 35 60 85
0
5
10
15
20
25
TA Ambient Temperature C
VOH GATE1 Voltage V
VI(VIN1) = 12 V
IO(GATE1) = 4 µA

SLUS503B MARCH 2002 REVISED AUGUST 2002
15
www.ti.com
TYPICAL CHARACTERISTICS
40 15 10 35 60 85
0
5
10
15
20
25
Figure 9
HIGH LEVEL OUTPUT VOLTAGE
vs
AMBIENT TEMPERATURE, LCA2
TA Ambient Temperature C
VOH GATE2 Voltage V
VI(VIN1) = 12 V
IO(GATE2) = 4 µA
40 15 10 35 60 85
0
5
10
15
20
25
Figure 10
HIGH LEVEL OUTPUT VOLTAGE
vs
AMBIENT TEMPERATURE, LCA3
TA Ambient Temperature C
VOH GATE3 Voltage V
VI(VIN1) = 12 V
IO(GATE3) = 4 µA
40 15 10 35 60 85
12
9
6
3
0
Figure 11
HIGH LEVEL OUTPUT VOLTAGE
vs
AMBIENT TEMPERATURE, LCA4
TA Ambient Temperature C
VOH GATE4 Voltage V
IO(GATE4) = 8 mA
40 15 10 35 60 85
62
58
54
52
48
60
56
50
Figure 12
IRAMP OUTPUT CURRENT
vs
AMBIENT TEMPERATURE
TA Ambient Temperature C
ICHG IRAMP Output Current µA
VO(IRAMP) = 0.5 V
Current Source Mode

SLUS503B MARCH 2002 REVISED AUGUST 2002
16 www.ti.com
TYPICAL CHARACTERISTICS
40 15 10 35 60 85
1.4
1.6
1.8
2.0
2.2
2.4
Figure 13
IRAMP INPUT CURRENT
vs
AMBIENT TEMPERATURE
TA Ambient Temperature C
IDSG IRAMP Input Current µA
VI(IRAMP) = 0.5 V
Current Sink Mode
Figure 14
IRAMP MODE TRIP THRESHOLD
vs
AMBIENT TEMPERATURE
TA Ambient Temperature C
VTRIP IRAMP Trip Threshold V
40 15 10 35 60 85
1.44
1.46
1.48
1.52
1.54
1.56
1.50
Figure 15
PRECHG OUTPUT VOLTAGE
vs
AMBIENT TEMPERATURE
TA Ambient Temperature C
VO(PCHG) Output Voltage V
40 15 10 35 60 85
0.0
0.2
0.4
0.6
0.8
1.2
1.0
IO(PRECHG) = 5 mA
IO(PRECHG) = 5 mA
VI(VIN2) = 4 V
VI(VIN1) = VI(VIN3) = VI(VIN4) = 0 V
Figure 16
PRECHG OUTPUT VOLTAGE
vs
SUPPLY VOLTAGE
4.0 4.5 5.0 5.5 6.0
0.90
0.92
0.98
1.06
1.10
0.94
0.96
1.00
1.02
1.08
1.04
VI(VIN2) Input Voltage V
VO(PCHG) Output Voltage V
VI(VIN3) = 3.3 V
VI(VIN1) = VI(VIN4) = FLOA T
TA = 25C
IOUT = 5 mA
IOUT = 5 mA

SLUS503B MARCH 2002 REVISED AUGUST 2002
17
www.ti.com
TYPICAL CHARACTERISTICS
Figure 17
PRECHARGE OUTPUT VOLTAGE
vs
OUTPUT CURRENT, SOURCING
IO(PCHG) Output Current mA
VO(PCHG) Output Voltage V
875
0.4
0.9
1.1
0.5
0.6
0.7
0.8
1.0
642310
VI(VIN2) = 4.75 V
VI(VIN3) = 3.30 V
VI(VIN1) = VI(VIN4) = FLOA T
TA = 25C
Figure 18
PRECHARGE OUTPUT VOLTAGE
vs
OUTPUT CURRENT, SINKING
IO(PCHG) Output Current mA
VO(PCHG) Output Voltage V
0.8
1.0
1.1
1.2
1.4
0.9
1.3
20486 10121416
VI(VIN2) = 5.25 V
VI(VIN3) = 3.30 V
VI(VIN1) = VI(VIN4) = FLOA T
TA = 25C

SLUS503B MARCH 2002 REVISED AUGUST 2002
18 www.ti.com
APPLICATION INFORMATION
The connections to set up the TPS2345 for operation in a CompactPCI plug-in are shown in the typical
application diagram.The TPS2345 works in conjunction with four external N-channel MOSFETs to provide
isolation of the back-end power planes when disabled, and to provide a low-impedance power path when the
load voltages are at the full-input dc potential. For proper operation, each channel of the device must be
connected to the appropriate supply as listed in Table 1.
Table 1. TPS2345 Channel to cPCI Supply Connections
TPS2345 CHANNEL cPCI SUPPLY
112 V
25 V
33.3 V
412 V
Sense resistors R1 through R4 connect between the VINx and CSx pins of their respective supplies, and
provide load current magnitude information to the TPS2345. To turn on the negative voltage channel, the device
pulls the gate of MOSFET Q4 towards ground potential. Resistor R5 provides a gate pull down when the LCA
turns off, as the Channel 4 LCA does not drive to the negative rail.
Capacitors C1 through C4 provide decoupling at the plug-in power pins, and are required by the CompactPCI
hot swap specification. For the 5-V and 3.3-V supplies, the specification recommends an average value of
between 0.1 µF and 0.2 µF per 10 pins. This capacitance may be distributed along the connector, or provided
as a single chip on each supply. Since there are eight 5-V and ten 3.3-V power pins at each backplane slot, two
0.1-µF ceramic capacitors meet this requirement. The ±12-V supplies should also be decoupled as shown.
All four capacitors should be placed close to the J1 connector, with trace length less than or equal to 0.6 inch.
Resistor R7 provides the 1.2-k pull-up on the BD_SEL# pin required by the hot swap specification. The pull-up
resistor is shown connected to the early 5-V plane; alternatively, it could be connected to early VIO. Resistor
R6 provides a pull-up to early VIO on the HEALTHY# signal; a 10-k resistor should suffice.
A capacitor with a value between 0.1 µF and 1 µF (C6 in the diagram) is required between the CPUMP pin and
ground. This capacitor provides charge storage for the on-board charge pump. A 0.1-µF ceramic is sufficient
for most applications.
ramp-up sequence
A successful ramp-up of the four cPCI back-end supplies consists of five pulses on the TPS2345 IRAMP pin.
One load voltage is ramped up during each of the first four IRAMP pulses. The fifth pulse enables the fault logic
of the last channel (Channel 4) to turn on. This is shown graphically in Figure 19.

SLUS503B MARCH 2002 REVISED AUGUST 2002
19
www.ti.com
APPLICATION INFORMATION
UDG02006
t0: BD_SEL# input brought low to initiate a turn-on sequence.
t1: Channel 1 (12V) gate enabled; IRAMP capacitor starts charging with slow turn-on clamp.
Slow charging of load voltage (back-end 12V) begins.
t2: Slow turn-on period ends; linear ramp of current to the load begins.
t3: Constant di/dt period ends; load voltage ramping continues at IMAX rate.
t4: BackEnd 12V reaches input DC potential.
t5: Channel 2 (5V) gate is enabled. Slow charging of load voltage (back-end 5V) begins. Fault monitoring on Ch. 1 enabled.
t6: Slow turn-on period ends; linear ramp of current to load begins.
t7: Constant di/dt period ends. Load voltage ramping continues at IMAX rate.
t8: BackEnd 5V reaches input DC potential.
t9: Channel 3 (3.3V) gate is enabled. Slow charging of load voltage (back-end 3.3V) begins. Fault monitoring on Ch. 2 enabled.
t10: Slow turnon period ends; linear ramp of current to the load begins.
t11: Constant di/dt period ends. Load voltage ramping continues at IMAX rate.
t12: BackEnd 3.3V reaches input DC potential.
t13: Channel 4 (12V) gate is enabled. Slow charging of load voltage (back-end 12V) begins. Fault monitoring on Ch. 3 enabled.
t14: Slow turn-on period ends; linear ramp of current to load begins.
t15: Constant di/dt period ends; load voltage ramping continues at IMAX rate.
t16: Back-end 12V reaches input DC potential.
t17: Channel 4 UV/OV fault enable pulse.
t18: HEALTHY# output pulled low.
HEALTHY#
t0 t1 t2 t3 t4 t5 t6 t7 t8 t9 t10 t11 t12 t13t14 t15 t16 t17t18
0 V
0 V
0 V
5 V
0 V
12 V
12 V
0 V
1.35 V
1.5 V
BD_SEL#
3.3 V
VO(IRAMP)
BACK-END
12-V
BACK-END
5-V
BACK-END
3.3-V
BACK-END
12-V
Figure 19. TPS2345 Ramp-Up Sequence

SLUS503B MARCH 2002 REVISED AUGUST 2002
20 www.ti.com
APPLICATION INFORMATION
A turn-on sequence is initiated when the BD_SEL# input is brought low (less than 0.8 V), assuming that all four
input supplies (at the VINx pins) are within their UV/OV tolerance windows. A voltage fault at any input supply
causes all loads to be held off. When BD_SEL# is asserted, the Channel 1 amplifier is enabled, and a 58-µA
current source begins charging the IRAMP capacitor to generate the first IRAMP pulse. During the linear rising
edge portion of the IRAMP waveform, current is linearly ramped to the 12-V back-end plane. Once the voltage
at IRAMP reaches 1.5 V, the source is replaced with a 1.8-µA sink that discharges IRAMP to 0 V. During this
discharge period, load charging current, if still required, is limited to IMAX, the current sense voltage (VMAX)
divided by the sense resistor value, RSNSx, or IMAXx = VMAXx / RSNSx, where x refers to any of the four
channels.
At the completion of the first pulse on IRAMP, the TPS2345 moves to the second voltage to be ramped up,
Channel 2, enables its LCA and begins generating the second pulse in the IRAMP train. At this time, fault
monitoring is enabled on the Channel 1 output. Therefore, if Channel 1 has failed to attain at least the
undervoltage threshold potential, a fault is detected, any active channels turned off, and the turn-on sequence
aborted. In this manner, the maximum time allowed for ramp-up of any of the channels is the duration of one
(1) IRAMP pulse. This protects against indefinite sourcing into faulted loads. The TPS2345 latches off in
response to faults, and can be reset either by toggling the BD_SEL# input high and then low again, or by cycling
power to the device.
After the Channel 2 ramp pulse, the backend planes for Channel 3 and Channel 4 are ramped up in similar
fashion. Channel 2 fault detection is enabled at the start of the Channel 3 ramp pulse, and so on. Once all four
supplies are ramped up, Channel 4 fault detection is enabled on the fifth IRAMP pulse. This last pulse is of
relatively short duration, as charge and discharge currents of approximately 256 µA are selected for the UV/OV4
enable pulse. If all four channels reach a known good state, the HEALTHY# output is asserted low.
Each load current waveform, at load turn-on, may have up to three distinct periods, as shown in Figure 20.
Initially after being enabled, the ramp generator output voltage is clamped to less than 100 mV. This results in
a corresponding clamp on load current of about 7% of the programmed IMAX value (with some variance due
to internal device offset). This temporary limit applies during approximately the first 500 µs of output ramping
time. The purpose of this slow ramp period is to ensure the LCA is pulled out of saturation, and is closely tracking
the CS input, prior to enabling fast charging of the load. During this time, appreciable ramping of the back-end
voltage may or may not occur, depending on a number of factors including the IMAX value, the amount of bulk
capacitance on the load, and the magnitude and polarity of inherent offsets in the current control loop.

SLUS503B MARCH 2002 REVISED AUGUST 2002
21
www.ti.com
APPLICATION INFORMATION
UDG02005
t1: Slow turn-on period
t2: Linear current ramp (di/dt)
t3: Constant-current load charging
tCHG: IRAMP capacitor charge time, (1.4 ×CIRAMP/58)
t1 t2 t3
0 V
VIN
0 A
IIMAX
0 V
0 V
1.5 V
TIME
IRAMP
VOLTAGE
GATE
VOLTAGE
LOAD
CURRENT
BACKEND
VOLTAGE
tCHG 32 x tCHG
Figure 20. Load Current at Startup
Once the slow ramp period has expired, the clamp is removed, and the IRAMP voltage continues to ramp up
at a constant rate of:
IO
CIRAMP +58 mA
CIRAMP
Since the linear amplifier acts to maintain equal voltages at its inputs (see Figure 2), it slews the GATEx output
such that the CSx voltage tracks the internally generated reference at its inverting input. Therefore, the linear
voltage ramp at the IRAMP pin results in a linear current ramp to the three positive loads.

SLUS503B MARCH 2002 REVISED AUGUST 2002
22 www.ti.com
APPLICATION INFORMATION
The LCA reference ramp tracks the IRAMP pin voltage up to a level of VO(IRAMP) ` 1.35 V. This corresponds
to the maximum sense voltage (VINx CSx) of 20 mV (150 mV for Channel 4). If charging of the load input bulk
capacitance completes during the constant di/dt section of channel turn-on (the set of dashed lines in Figure 20),
the load current decays to the steady-state operating level. With decreasing load current, the CSx input is pulled
to the VINx potential, and the pass MOSFET gate is driven to the LCA supply rail, fully enhancing the external
MOSFET. However, under certain combinations of bulk capacitance, IMAX, and inrush di/dt relative values,
the current ramp may reach the IMAX limit. The variable current source is switched out for the constant current
source which sets the VMAX reference level (see Figure 2). This defines the third stage of the load current
waveform. Load voltage ramping completes at the IMAX level, as shown by the set of solid lines in Figure 20.
Again, once the current demand rolls off, the LCA drives the pass MOSFET gate high to fully enhance the
MOSFET.
ramp-down sequence
A normal shutdown sequence occurs when the BD_SEL# input is brought high ( greater than 2 V) with the output
supplies in a healthy state (no overvoltage, undervoltage or overcurrent faults). HEALTHY# is deasserted and
the back-end voltages are sequenced off in the reverse order of turn on: 12-V, 3.3-V, 5-V and 12-V (Channel 4,
Channel 3, Channel 2 and then Channel 1). The turn of f is also controlled by five pulses at the IRAMP pin. The
first pulse, which is of short duration, disables the voltage fault monitoring on Channel 4 (12 V). Starting with
the second pulse, each supply is turned off in order. At the start of each pulse at IRAMP, voltage fault monitoring
is disabled for the next successive channel to be turned off. The IRAMP capacitor is charged rapidly, up to the
1.5-V threshold, at which point the variable current source in the LCA block is reselected to generate the current
limit reference. At the same time, the charging source at IRAMP is replaced with a 58-µA discharge load, such
that the IRAMP capacitor is discharged at the same rate used for di/dt control during turn on. This causes the
current limit to decrease linearly, so that available load current is forced off no faster than the falling edge at
IRAMP. The LCA is disabled, and additional pull-downs applied to the GATEx pin, when either the output voltage
has decayed to less than 0.9 V, or the IRAMP waveform has decayed to approximately 0.1 V. Under conditions
of light loading during turn off, the bulk capacitance may hold up the back-end voltage even after the MOSFET
switch i s turned of f. In this situation, the TPS2345 waits for load discharge to less than 0.9 V prior to proceeding
to the next channel. Channel 4 is the exception to this operation; the VS4 status is not monitored during turn off,
and the device sequences to Channel 3 turn-off once the second IRAMP pulse ends.
setting the sense resistor values
Due to the current limiting operation of the internal LCAs, the maximum allowable load current for the application
is easily programmed by selecting the appropriate value sense resistors. The LCA acts to limit the CSx voltage
(relative to VINx) to the internal reference, which during steady-state operation is VMAX. Therefore, a sense
resistor for each channel can be calculated from equation (1).
RSNSx +VMAXx
IMAXx
where
RSNSx is the the sense resistor value for Channel x,
VMAXx is the IMAX sense voltage limit, and
IMAXx is the Channel x maximum load current.
(1)

SLUS503B MARCH 2002 REVISED AUGUST 2002
23
www.ti.com
APPLICATION INFORMATION
When setting the current limits, it is important to consider the device minimum that may be imposed by the
TPS2345. Using the values given in the electrical tables, equations (2) through (4) follow from equation (1).
For Channel 1:
RSNS1 +16 mV
IMAX1
For Channels 2 and 3:
RSNSx +17 mV
IMAXx
where:
x = 2 or 3.
For Channel 4:
RSNS4 +75 mV
IMAX4
To ensure proper operation across the range of anticipated load currents on each channel, the maximum load
under normal operating conditions must also be considered. To avoid current-limit operation during steady-state
loading, the IMAX level must be set above the expected load. For example, if the 3.3-V (Channel 3) supply of
the typical application diagram needs to deliver up to 6.5 A, and a 500-mA margin is desired, using equation
(3) yields:
R3 +17 mV
7A +2.43 mW
This value is rounded up to 2.5 m in the schematic. Similarly, for up to 600-mA capability on Channel 1,
equation (2) indicates R1 ` 25 mΩ. Setting R4 = 250 m, provides some margin over a 250 mA load. Also,
these values limit the maximum load within the cPCI specification limits.
setting the inrush slew rate
The TPS2345 is easily programmed for the desired maximum current slew rate during turn-on and turn-off
events. A s in g l e capacitor at the IRAMP pin (C5 in the diagram) controls the di/dt for all three positive channels.
Once the sense resistor values have been established, the value for CIRAMP, in microfarads, can be determined
from equation (5).
For Channels 1, 2, and 3:
CIRAMPx +68
67.5 RSNSx ǒdi
dtǓx
where:
CIRAMPx = the capacitor value indicated to achieve the (di/dt)x limit value,
RSNSx = sense resistor in ohms and
(di/dt)x = the maximum di/dt rate, in amps/second.
(2)
(3)
(4)
(5)

SLUS503B MARCH 2002 REVISED AUGUST 2002
24 www.ti.com
APPLICATION INFORMATION
The CompactPCI hot swap specification requires the following maximum slew rates for the input supplies (see
Table 2).
Table 2. CompactPCI Hot Swap Slew Rate Specifications
SUPPLY NAME MAXIMUM
SLEW RATE
5 V 1.5 A/ms
3.3 V 1.5 A/ms
12 V 150 mA/ms
12 V 150 mA/ms
Since the 12-V supplies have the more stringent limit, they are useful for obtaining an initial estimate for the
IRAMP capacitor. Using the 12-V supply values, equation (5) produces the result shown in equation (6).
CIRAMP1 +68
67.5 (0.025 W) ǒ150 mAńmsǓ^0.27 mF
A value of 0.27 µF can be used, or the next available standard value of 0.33 µF provides some margin for
capacitor and sense-resistor tolerances. In either case, equation (5) can be rewritten as equation (7), which is
used here to verify that the 5-V and 3.3-V slew rates are within specification.
ǒdińdtǓ2,3 +68
67.5 RSNS2,3 CIRAMP
where:
RSNS2,3 is in ohms,
CIRAMP is in microfarads, and
(di/dt)2,3 is given in amps/second.
For a CIRAMP of 0.33 µF, the maximum di/dt for the 5-V and 3.3-V supplies is 1.02 A/ms and 1.22 A/ms,
respectively, which is well within the cPCI specification.
protection against faulted loads
The TPS2345 allows the time period of one IRAMP pulse for each back-end planes voltage to ramp-up to its
minimum level. After this delay period, the device latches off if an undervoltage fault is subsequently detected.
This nominal delay time, tTIMER, is set by the constant-current charging and subsequent discharging of CIRAMP,
and is therefore determined from equation (8).
tTIMER +CIRAMP 1.4 ǒ1
58 )1
1.8Ǔ
where:
CIRAMP is in microfarads.
The resultant fault timer period should be sufficient for most applications; however, it is good design practice
to verify that the delay is long enough for each load.
(6)
(7)
(8)

SLUS503B MARCH 2002 REVISED AUGUST 2002
25
www.ti.com
APPLICATION INFORMATION
Due to the potential three-phase nature of the load current ramp (refer to Figure 20), the increasing load voltage
may also have three distinct periods. The first phase is during the slow turn-on period at the start of each IRAMP
cycle. Depending on a number of factors, significant voltage ramping may or may not occur during this time.
Also, any appreciable voltage ramp is more likely on the 3.3-V and 5-V loads. For verification of the fault timeout
delay, the worst case situation is no appreciable load charging (i.e., a longer overall charge time); therefore it
is assumed that no voltage ramp occurs here.
The next phase is the linear load current ramp period. For any device channel x, if the IMAX level is not reached
while charging a given load capacitor of CLx, then the time to reach the input dc level, VINx, is estimated by
equation (9).
tSSx +2 CLx CIRAMP KX RSNSx VINx
58 mA
Ǹ
where:
KX = 67.5 for Channels 1, 2, and 3, and
KX = 7.5 for Channel 4.
For example, assuming the 5-V back-end plane in this application has 220-µF bulk capacitance, the anticipated
typical ramp-up time is about 1.6 ms.
During inrush slewing, the load current ramp tracks the voltage ramp on the IRAMP capacitor, up to a voltage
of about 1.35 V on the IRAMP pin. Therefore, the time duration of this ramp activity, tIRAMP, is given by
equation (10).
tIRAMP +CIRAMP (1.25 V)
58
where:
CIRAMP is in microfarads.
If, for any channel, the time for soft-start charging of the load voltage is greater than the current ramp period,
(tSSx > tIRAMP), back-end plane ramp-up completes at the dc IMAX level. In this case, the following procedure
can be used to estimate load ramp-up time.
First, equation (11) is used to determine the load voltage level, vLx(t), attained during the current ramp period.
vLxǒtIRAMPǓ+58 mA
2 CLx CIRAMP KX RSNSx ǒtIRAMPǓ2
Once this voltage level is known, it can be used to estimate the additional charging time required at constant
current to reach the input dc potential, tCCx. This time is calculated from equation (12).
tCCx +CLx ǒVINx *VLx ǒtIRAMPǓǓ
IMAXx
The sum of tIRAMP and tCCx can then be used to estimate the total load ramp-up time for Channel x.
(9)
(10)
(11)
(12)

SLUS503B MARCH 2002 REVISED AUGUST 2002
26 www.ti.com
APPLICATION INFORMATION
precharge circuit
The PRECHG pin can be used to generate the 1-V bias voltage which precharges the CompactPCI bus signals
during hot swap events. The pins output stage has both source and sink capability, enabling it to pull lines up
from 0 V or down from V(I/O) as needed. Typically, each I/O line requiring precharge is isolated from the
PRECHG source with a minimum 10-k resistor (RP in the typical application diagram). Depending on the
signaling level of a particular system (5 V or 3.3 V), other requirements for precharge resistor value and
disconnection may apply. Numerous manufacturers currently of fer integrated bus switches that may be useful
when disconnection is desired or required. A stub resistor (R8) is inserted in each I/O line as shown, which helps
provide some series damping. The value of this resistor is specified as 10 ±5%, placed within 0.6 inch of the
connector.
generating LOCAL_PCI_RST#
The LOCAL_PCI_RST# signal used to initialize the plug-ins PCI device in CompactPCI systems is easily
generated from the TPS2345s HEALTHY# output using as few as two logic gates. A suggested solution is
shown in Figure 21. The circuit functions such that LOCAL_PCI_RST# is asserted whenever back-end power
is not healthy, regardless of the status of PCI_RST#. Texas Instruments and several other manufacturers
produce a series of single-gate devices in small footprint, 5-pin packages. Table 3 lists some of the options
available within three of the technologies available from TI: AHC, AHCT, and LVC. The applicable device
numbers are shown sorted according to signaling environment and package type. Chip-scale packaging may
also be available for the LVC types.
UDG02015
EARLY
POWER
04
08
PCI_RST#
HEALTHY#
LOCAL_PCI_RST#
54
3
2
1
54
3
2
Figure 21. LOCAL_PCI_RST# Circuit
Table 3. Texas Instruments Little Logic Device Options
SIGNALING
DEVICE
PACKAGED DEVICES
SIGNALING
ENVIRONMENT DEVICE SOT23 (DBV) SC70 (DCK)
5V
04 SN74AHCT1G04DBVR SN74AHCT1G04DCKR
5V 08 SN74AHCT1G08DBVR SN74AHCT1G08DCKR
04 SN74AHC1G04DBVR SN74AHC1G04DCKR
33V
08 SN74AHC1G08DBVR SN74AHC1G08DCKR
3.3V 04 SN74LVC1G04DBVR SN74LVC1G04DCKR
08 SN74LVC1G08DBVR SN74LVC1G08DCKR

SLUS503B MARCH 2002 REVISED AUGUST 2002
27
www.ti.com
APPLICATION INFORMATION
protecting the TPS2345 from voltage transients
Parasitic inductance associated with the power distribution network can cause large voltage spikes on the
supply rails if the current is suddenly interrupted by the TPS2345 during a fault condition. It is important to protect
the TPS2345 against such spikes to avoid device damage. There are several practices that provide sufficient
protection.
Clamp the voltage at the supply pins of the TPS2345 with Zener diodes. Since the absolute maximum
voltage ra t i n g o f t h e d evice is 15 V, this is most important on the 12-V and 12-V rails. The typical application
diagram shows the connection of these devices (D1 and D2) in the circuit. The diodes should be placed
close to the TPS2345, with short trace lengths back to the VINx and GND pins. The maximum breakdown
of these devices must be less than 15 V to properly protect the TPS2345. Lower voltage Zeners can also
be placed on the 5-V and 3.3-V pins if desired, but the steady-state operating level of these pins provides
more margin from damage levels. In addition, it may be necessary to protect the sense inputs on the 12-V
and 12-V back-end planes, VS1 and VS4, depending on the PCB characteristics.
Use dedicated PCB planes for the four supplies and ground nodes and maximize the trace width of
high-current runs to minimize inductance associated with the power distribution. This is recommended on
both the backplane and plug-in modules.
layout considerations
To optimize the performance of the TPS2345, care should be taken to use good layout practice with the parts
placement and etch routing of the hot swap circuit components. This includes any protection devices as well
as the sense and pass elements. Protection devices should be located close to the hot swap controller, and
trace-lengths back to their respective pins kept to a minimum. If a decoupling capacitor is used on the VIN1
supply, it also should be placed close to the part.
Mount the charge pump reservoir capacitor (C6 in the application diagram) close to the TPS2345, with minimal
trace lengths back to the CPUMP and CPGND pins.
For proper operation, the three ground pins of the TPS2345 must be connected together near the device. The
ground leads of the ramp and charge pump capacitors, protection diodes, and any decoupling capacitors should
also tie into this node close to the part. This junction should be routed separately back to the J1 connector, where
it can tie into the PCB GND node, as opposed to tying into the ground plane elsewhere in the high-current return
path.
Use wide traces when connecting the sense resistors and power FETs into their respective current paths. When
feeding these connections through from an internal power plane, use multiple vias to reduce the overall
impedance of the current path. This helps reduce insertion loss across the hot swap interface, and improve the
thermal performance of the PCB. Additional copper plane used on the land patterns of these devices can
significantly reduce their thermal impedance, reducing temperature rise in the module and improving overall
reliability of the power devices.
Connections to the sense resistors for the VINx and CSx device pins should be made with good Kelvin
connections to optimize the accuracy of the current-limit thresholds and slew-rate control. This is especially
important for the 5-V and 3.3-V sense connections. Because typical load levels on these supplies are so high,
up to 10 A, board trace resistance between elements in the supply current paths becomes significant. The two
sense traces for each supply should connect symmetrically to the sense resistor land pattern, in close proximity
to the element leads, and not upstream or downstream from the device. Trace routing back to the TPS2345
should be fairly well balanced. Figure 22 illustrates two recommendations for the current sense layout.

SLUS503B MARCH 2002 REVISED AUGUST 2002
28 www.ti.com
APPLICATION INFORMATION
UDG02014
*Additional details ommited for clarity
LOAD CURRENT PATH LOAD CURRENT PATH
SENSE
RESISTOR
TPS2345*
22
21
TPS2345*
22
21
(a) (b)
Figure 22. Recommended Layout for SMD Chip-Sense Resistor for 5-V Rail
PACKAGE OPTION ADDENDUM
www.ti.com 11-Apr-2013
Addendum-Page 1
PACKAGING INFORMATION
Orderable Device Status
(1)
Package Type Package
Drawing Pins Package
Qty Eco Plan
(2)
Lead/Ball Finish MSL Peak Temp
(3)
Op Temp (°C) Top-Side Markings
(4)
Samples
TPS2345PW NRND TSSOP PW 24 TBD Call TI Call TI -40 to 85
TPS2345PWG4 NRND TSSOP PW 24 TBD Call TI Call TI -40 to 85
TPS2345PWR NRND TSSOP PW 24 TBD Call TI Call TI -40 to 85
TPS2345PWRG4 NRND TSSOP PW 24 TBD Call TI Call TI -40 to 85
(1) The marketing status values are defined as follows:
ACTIVE: Product device recommended for new designs.
LIFEBUY: TI has announced that the device will be discontinued, and a lifetime-buy period is in effect.
NRND: Not recommended for new designs. Device is in production to support existing customers, but TI does not recommend using this part in a new design.
PREVIEW: Device has been announced but is not in production. Samples may or may not be available.
OBSOLETE: TI has discontinued the production of the device.
(2) Eco Plan - The planned eco-friendly classification: Pb-Free (RoHS), Pb-Free (RoHS Exempt), or Green (RoHS & no Sb/Br) - please check http://www.ti.com/productcontent for the latest availability
information and additional product content details.
TBD: The Pb-Free/Green conversion plan has not been defined.
Pb-Free (RoHS): TI's terms "Lead-Free" or "Pb-Free" mean semiconductor products that are compatible with the current RoHS requirements for all 6 substances, including the requirement that
lead not exceed 0.1% by weight in homogeneous materials. Where designed to be soldered at high temperatures, TI Pb-Free products are suitable for use in specified lead-free processes.
Pb-Free (RoHS Exempt): This component has a RoHS exemption for either 1) lead-based flip-chip solder bumps used between the die and package, or 2) lead-based die adhesive used between
the die and leadframe. The component is otherwise considered Pb-Free (RoHS compatible) as defined above.
Green (RoHS & no Sb/Br): TI defines "Green" to mean Pb-Free (RoHS compatible), and free of Bromine (Br) and Antimony (Sb) based flame retardants (Br or Sb do not exceed 0.1% by weight
in homogeneous material)
(3) MSL, Peak Temp. -- The Moisture Sensitivity Level rating according to the JEDEC industry standard classifications, and peak solder temperature.
(4) Multiple Top-Side Markings will be inside parentheses. Only one Top-Side Marking contained in parentheses and separated by a "~" will appear on a device. If a line is indented then it is a
continuation of the previous line and the two combined represent the entire Top-Side Marking for that device.
Important Information and Disclaimer:The information provided on this page represents TI's knowledge and belief as of the date that it is provided. TI bases its knowledge and belief on information
provided by third parties, and makes no representation or warranty as to the accuracy of such information. Efforts are underway to better integrate information from third parties. TI has taken and
continues to take reasonable steps to provide representative and accurate information but may not have conducted destructive testing or chemical analysis on incoming materials and chemicals.
TI and TI suppliers consider certain information to be proprietary, and thus CAS numbers and other limited information may not be available for release.
In no event shall TI's liability arising out of such information exceed the total purchase price of the TI part(s) at issue in this document sold by TI to Customer on an annual basis.
IMPORTANT NOTICE
Texas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, enhancements, improvements and other
changes to its semiconductor products and services per JESD46, latest issue, and to discontinue any product or service per JESD48, latest
issue. Buyers should obtain the latest relevant information before placing orders and should verify that such information is current and
complete. All semiconductor products (also referred to herein as “components”) are sold subject to TI’s terms and conditions of sale
supplied at the time of order acknowledgment.
TI warrants performance of its components to the specifications applicable at the time of sale, in accordance with the warranty in TI’s terms
and conditions of sale of semiconductor products. Testing and other quality control techniques are used to the extent TI deems necessary
to support this warranty. Except where mandated by applicable law, testing of all parameters of each component is not necessarily
performed.
TI assumes no liability for applications assistance or the design of Buyers’ products. Buyers are responsible for their products and
applications using TI components. To minimize the risks associated with Buyers’ products and applications, Buyers should provide
adequate design and operating safeguards.
TI does not warrant or represent that any license, either express or implied, is granted under any patent right, copyright, mask work right, or
other intellectual property right relating to any combination, machine, or process in which TI components or services are used. Information
published by TI regarding third-party products or services does not constitute a license to use such products or services or a warranty or
endorsement thereof. Use of such information may require a license from a third party under the patents or other intellectual property of the
third party, or a license from TI under the patents or other intellectual property of TI.
Reproduction of significant portions of TI information in TI data books or data sheets is permissible only if reproduction is without alteration
and is accompanied by all associated warranties, conditions, limitations, and notices. TI is not responsible or liable for such altered
documentation. Information of third parties may be subject to additional restrictions.
Resale of TI components or services with statements different from or beyond the parameters stated by TI for that component or service
voids all express and any implied warranties for the associated TI component or service and is an unfair and deceptive business practice.
TI is not responsible or liable for any such statements.
Buyer acknowledges and agrees that it is solely responsible for compliance with all legal, regulatory and safety-related requirements
concerning its products, and any use of TI components in its applications, notwithstanding any applications-related information or support
that may be provided by TI. Buyer represents and agrees that it has all the necessary expertise to create and implement safeguards which
anticipate dangerous consequences of failures, monitor failures and their consequences, lessen the likelihood of failures that might cause
harm and take appropriate remedial actions. Buyer will fully indemnify TI and its representatives against any damages arising out of the use
of any TI components in safety-critical applications.
In some cases, TI components may be promoted specifically to facilitate safety-related applications. With such components, TI’s goal is to
help enable customers to design and create their own end-product solutions that meet applicable functional safety standards and
requirements. Nonetheless, such components are subject to these terms.
No TI components are authorized for use in FDA Class III (or similar life-critical medical equipment) unless authorized officers of the parties
have executed a special agreement specifically governing such use.
Only those TI components which TI has specifically designated as military grade or “enhanced plastic” are designed and intended for use in
military/aerospace applications or environments. Buyer acknowledges and agrees that any military or aerospace use of TI components
which have not been so designated is solely at the Buyer's risk, and that Buyer is solely responsible for compliance with all legal and
regulatory requirements in connection with such use.
TI has specifically designated certain components as meeting ISO/TS16949 requirements, mainly for automotive use. In any case of use of
non-designated products, TI will not be responsible for any failure to meet ISO/TS16949.
Products Applications
Audio www.ti.com/audio Automotive and Transportation www.ti.com/automotive
Amplifiers amplifier.ti.com Communications and Telecom www.ti.com/communications
Data Converters dataconverter.ti.com Computers and Peripherals www.ti.com/computers
DLP® Products www.dlp.com Consumer Electronics www.ti.com/consumer-apps
DSP dsp.ti.com Energy and Lighting www.ti.com/energy
Clocks and Timers www.ti.com/clocks Industrial www.ti.com/industrial
Interface interface.ti.com Medical www.ti.com/medical
Logic logic.ti.com Security www.ti.com/security
Power Mgmt power.ti.com Space, Avionics and Defense www.ti.com/space-avionics-defense
Microcontrollers microcontroller.ti.com Video and Imaging www.ti.com/video
RFID www.ti-rfid.com
OMAP Applications Processors www.ti.com/omap TI E2E Community e2e.ti.com
Wireless Connectivity www.ti.com/wirelessconnectivity
Mailing Address: Texas Instruments, Post Office Box 655303, Dallas, Texas 75265
Copyright © 2013, Texas Instruments Incorporated