STANDARD
MICROCIRCUIT DRAWING
SIZE
A
5962-87650
DEFENSE SUPPLY CENTER COLUMBUS
COLUMBUS, OHIO 43218-3990 REVISION LEVEL
F SHEET 4
DSCC FORM 2234
APR 97
3.3 Electrical performance characteristics. Unless otherwise specified herein, the electrical performance characteristics are
as specified in table I and shall apply over the full case operating temperature range.
3.4 Electrical test requirements. The electrical test requirements shall be the subgroups specified in table II. The electrical
tests for each subgroup are described in table I.
3.5 Marking. Marking shall be in accordance with MIL-PRF-38535, appendix A. The part shall be marked with the PIN listed
in 1.2 herein. In addition, the manufacturer's PIN may also be marked. For packages where marking of the entire SMD PIN
number is not feasible due to space limitations, the manufacturer has the option of not marking the "5962-" on the device.
3.5.1 Certification/compliance mark. A compliance indicator “C” shall be marked on all non-JAN devices built in compliance
to MIL-PRF-38535, appendix A. The compliance indicator “C” shall be replaced with a "Q" or "QML" certification mark in
accordance with MIL-PRF-38535 to identify when the QML flow option is used.
3.6 Processing EPROMS. All testing requirements and quality assurance provisions herein shall be satisfied by the
manufacturer prior to delivery.
3.6.1 Erasure of EPROMS. When specified, devices shall be erased in accordance with the procedures and characteristics
specified in 4.4.
3.6.2 Programmability of EPROMS. When specified, devices shall be programmed to the specified pattern using the
procedures and characteristics specified in 4.5.
3.6.3 Verification of erasure or programmability of EPROMS. When specified, devices shall be verified as either
programmed to the specified pattern or erased. As a minimum, verification shall consist of performing a functional test
(subgroups 7 and 8) to verify that all bits are in proper state. Any bit that does not verify to be in the proper state shall
constitute a device failure and shall be removed from the lot.
3.7 Certificate of compliance. A certificate of compliance shall be required from a manufacturer in order to be listed as an
approved source of supply in MIL-HDBK-103 (see 6.6 herein). The certificate of compliance submitted to DSCC-VA prior to
listing as an approved source of supply shall affirm that the manufacturer's product meets the requirements of MIL-PRF-38535,
appendix A and the requirements herein.
3.8 Certificate of conformance. A certificate of conformance as required in MIL-PRF-38535, appendix A shall be provided
with each lot of microcircuits delivered to this drawing.
3.9 Notification of change. Notification of change to DSCC-VA shall be required for any change that affects this drawing
3.10 Verification and review. DSCC, DSCC's agent, and the acquiring activity retain the option to review the manufacturer's
facility and applicable required documentation. Offshore documentation shall be made available onshore at the option of the
reviewer.
3.11 Data retention. A data retention stress test shall be completed as part of the vendor's reliability monitors. This test shall
be done for initial characterization and after any design or process change which may affect data retention. The methods and
procedures may be vendor specific, but shall guarantee the number of years listed in section 1.3 herein over the full military
temperature range. The vendor's procedure shall be kept under document control and shall be made available upon request of
the acquiring or preparing activity, along with test data.
3.12 Endurance. A reprogrammability test shall be completed as part of the vendor's reliability monitors. This test shall be
done for initial characterization and after any design or process change which may affect the reprogrammability of the device.
The methods and procedures may be vendor specific, but shall guarantee the number of program/erase endurance cycles listed
in section 1.3 herein over the full military temperature range. The vendor's procedure shall be kept under document control and
shall be made available upon request of the acquiring or preparing activity, along with test data.