Power Pedestals
Power Pedestals
Construction Site and RV Parks
Marina Power and Lighting
Mobile Home Panels
5.1 Introduction
Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .V1-T5-2
Application Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .V1-T5-2
Optional Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .V1-T5-2
5.2 Temporary Power/RV Park
Product Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .V1-T5-3
Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .V1-T5-3
Application Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .V1-T5-4
Standards and Certifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .V1-T5-5
Catalog Number Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .V1-T5-6
Product Selection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .V1-T5-7
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .V1-T5-7
Renewal Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .V1-T5-8
Surface Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .V1-T5-10
Product Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .V1-T5-10
Product Selection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .V1-T5-10
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .V1-T5-13
Pedestal Units. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .V1-T5-16
Product Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .V1-T5-16
Product Selection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .V1-T5-16
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .V1-T5-18
5.3 Mobile Home Panels
Product Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .V1-T5-21
Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .V1-T5-21
Catalog Number Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .V1-T5-22
Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .V1-T5-22
Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .V1-T5-23
Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .V1-T5-24
5.4 RV Park Hook-Ups
Power Pedestals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .V1-T5-28
Powerhouse Power Pedestal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .V1-T5-30
Powerhouse—Stainless Steel (SS) Power Pedestal . . . . . . . . . . . . . . .V1-T5-33
Newport Camp Mate Power Pedestal . . . . . . . . . . . . . . . . . . . . . . . . .V1-T5-36
Firehouse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .V1-T5-39
Digital Electronic Kilowatthour Meters . . . . . . . . . . . . . . . . . . . . . . . . .V1-T5-41
Distribution Equipment—Ground Fault Monitor . . . . . . . . . . . . . . . . . .V1-T5-42
Distribution Equipment—Substations. . . . . . . . . . . . . . . . . . . . . . . . . .V1-T5-43
Distribution Equipment—Panels. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .V1-T5-46
Distribution Equipment—Transformers. . . . . . . . . . . . . . . . . . . . . . . . .V1-T5-47
5.5 Marina Power and Lighting Equipment
Power Pedestals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .V1-T5-48
Lighthouse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .V1-T5-51
Lighthouse–SS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .V1-T5-55
Admiral–SS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .V1-T5-59
Newport Harbor Mate. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .V1-T5-62
Hatteras Light . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .V1-T5-66
Firehouse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .V1-T5-70
Smart Start . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .V1-T5-76
Mariner . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .V1-T5-77
Digital Electronic Kilowatthour Meters . . . . . . . . . . . . . . . . . . . . . . . . .V1-T5-78
Distribution Equipment—Ground Fault Monitor . . . . . . . . . . . . . . . . . .V1-T5-79
Distribution Equipment—Mega Yacht Powerpoint . . . . . . . . . . . . . . . .V1-T5-80
Distribution Equipment—Substations. . . . . . . . . . . . . . . . . . . . . . . . . .V1-T5-83
Distribution Equipment—Panels. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .V1-T5-86
Distribution Equipment—Transformers. . . . . . . . . . . . . . . . . . . . . . . . .V1-T5-87
Don’t Give Up!
If you don’t find the product you want in this catalog, try the Flex Center at 1-800-330-6479.
Volume 1—Residential and Light Commercial, CA08100002E
Tab 5—Power Pedestals
Revision date Section Change page(s) Description
03/29/2019 V1-T5-1 Update Tab TOC
03/29/2019 5.4 V1-T5-31 Content edit to Catalog Number Selection
03/29/2019 5.4 V1-T5-34 Content edit to Catalog Number Selection
03/29/2019 5.4 V1-T5-37 Content edit to Catalog Number Selection
03/29/2019 5.4 V1-T5-39–V1-T5-41 Delete Park Light Power Pedestal
03/29/2019 5.4 V1-T5-39 Content edit to Catalog Number Selection; update to page numbering
03/29/2019 5.5 V1-T5-53 Content edit to Catalog Number Selection; update to page numbering
03/29/2019 5.5 V1-T5-57 Content edit to Catalog Number Selection; update to page numbering
03/29/2019 5.5 V1-T5-60 Content edit to Catalog Number Selection; update to page numbering
03/29/2019 5.5 V1-T5-64 Content edit to Catalog Number Selection; update to page numbering
03/29/2019 5.5 V1-T5-71 Content edit to Catalog Number Selection; update to page numbering
03/29/2019 5.5 V1-T5-74 Content edit to Catalog Number Selection; update to page numbering
03/29/2019 5.5 V1-T5-77 Content edit to Catalog Number Selection; update to page numbering
Revision notes
V1-T5-2 Volume 1—Residential and Light Commercial CA08100002E—March 2019 www.eaton.com
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5.1
Power Pedestals
Introduction
Power Pedestals
Contents
Description
Introduction
Product Description
A power pedestal is a device
designed for outdoor service
to meet temporary power
requirements at construction
sites, marinas, recreational
vehicle (RV parks, marinas
and mobile home parks).
Power pedestals provide a
safe and reliable means for
users to access electricity
at such locations.
Application Description
Construction Site and
RV Parks
Power outlet panels on
construction sites and in
RV parks provide a safe and
reliable means for users to
access electricity. A wide
range of products are available
with multiple features and
enclosure material options.
Construction Site and RV Parks
Mobile Home Panels
Eaton’s versatile mobile home
panels have a user-friendly
design that allows for a faster,
cleaner installation. Mobile
home panels are designed for
service entrance distribution,
and include a meter and
distribution section with
breaker and receptacle
configuration options.
Mobile Home Panels
Marina Power and Lighting
Park lighting and marina
pedestals offer robust
enclosure options with
premium features to enhance
user convenience at marinas
and campgrounds.
Marina Power and Lighting
Optional Features
Product can ship from the
factory completely
assembled and prewired
External light
TV and telephone jacks
Ground fault monitors
Digital electronic
kilowatthour meters
Water faucet
Available GFI (ground fault
interrupter) protection
Weatherproof engineered
resin enclosure (will never
rust or deteriorate)
Stainless steel to meet
and exceed all applicable
codes, and withstand
harsh inland and coastal
environments
Volume 1—Residential and Light Commercial CA08100002E—March 2019 www.eaton.com V1-T5-3
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5.2
Power Pedestals
Temporary Power/RV Park
Power Outlet Panels
Contents
Description Page
Product Description . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-2
Application Description . . . . . . . . . . . . . . . . . . . V1-T5-4
Optional Features . . . . . . . . . . . . . . . . . . . . . . . V1-T5-2
Standards and Certifications . . . . . . . . . . . . . . . V1-T5-5
Catalog Number Selection . . . . . . . . . . . . . . . . V1-T5-6
Product Selection . . . . . . . . . . . . . . . . . . . . . . . V1-T5-7
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-7
Renewal Parts . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-8
Surface Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-10
Pedestal Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-16
Product Overview
A power outlet panel (or POP)
is a device designed for
outdoor service to meet
temporary power
requirements at construction
sites and RV parks. POPs
provide a safe and reliable
means for users to access
electricity at such locations.
Product Description
Power outlet panels shall be
designed for outdoor service
to meet temporary power
outlet requirements at
construction sites and provide
high quality, economical
power to individual sites
at RV parks. POPs shall be
provided with means to bond
the neutral for temporary
service entrance applications.
RV panels shall have a factory-
installed insulated neutral bar.
Receptacles and
Circuit Protection
Circuit protection shall be
Eaton’s UL listed full-size
Type BR or half-size Type BD
circuit breakers. The
receptacles shall be NEMA
commercial/industrial grade
devices. Ground fault
protection (GFCB) shall be
provided at the 20 A duplex
NEMA 5-20R receptacle or
20 A single-pole circuit
breaker per UL standards.
Ground fault protection shall
be provided at the circuit
breaker for receptacles above
20 A per UL standards.
Construction
The power outlet panel
pedestal shall be of deadfront
design and constructed of
heavy gauge, 100 percent
galvanized steel. Baked-on
polyester powder coating
shall be used for excellent
mechanical strength, plus
resistance to chalking caused
by the sun’s ultraviolet rays.
The power outlet panel
surface and pedestal units
shall have NEMA Type 3R
rainproof enclosures.
Ease of Installation
Panels shall ship from the
factory completely assembled
,
prewired with aluminum wire,
and tested in accordance with
UL Standard 231. The door
shall swing up and open for
user convenience and ease
of access to breakers and
receptacles. When required,
a means for securing the
door in the open position
shall be provided. Panels
shall be bottom fed through
knockouts in endwall or top
fed using a bolt-on raintight
hub. Knockouts shall range
from 1/2-inch (12.7 mm) to
1-1/2 inches (38.1 mm).
Grounding provisions
(#4–14 Cu/Al) shall be
provided on all panels.
V1-T5-4 Volume 1—Residential and Light Commercial CA08100002E—March 2019 www.eaton.com
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5.2
Power Pedestals
Temporary Power/RV Park
Application Description
POPs are also sometimes
called temporary power
panels, temporary site
service equipment or
RV panels.
Construction Site Application
When POPs are used at a
construction site, they are
installed on a temporary basis
until permanent electrical
power is available at the
building. The most common
reason for needing a POP
at a construction site is to
provide a power source for
the contractor’s tools.
Construction Site Application
RV Park Applications
When POPs are used at an
RV park, they are installed
for more permanent use
and serve the purpose of
providing power to the
recreational vehicles. Many
RV parks now supply
customers with amenities
such as lighted POPs with TV
and telephone jacks.
RV Park Application
Service Applications
Suitable for use as temporary
Service Entrance Equipment,
temporary power service
equipment and recreational
vehicle site supply.
Features and Benefits
Designed for outdoor
service to meet power
outlet requirements
Receptacles conform
to NEMA and/or ANSI
configurations as specified
by the National Electrical
Code® (NEC)
Includes a factory-installed
insulated neutral bar with
provisions for bonding
when used for temporary
service entrance
applications
125 A rated meter socket
Temporary power and RV
park POPs are CSA listed.
Compact POP and single
receptacle devices are not
CSA listed
Designed for Easy Installation
and Protection
Panels come from the
factory completely
assembled, prewired
with aluminum wire and
tested… ready for easy
installation
Door swings up and open
for user convenience and
ease of access to breakers
and receptacles
Panels can be bottom fed
through knockouts in the
endwall or top fed using a
bolt-on raintight hub
Two-piece deadfront cover
allows field wiring without
interfering with factory
wiring
Lower deadfront cover
permits easy field wiring to
circuit protective devices
Available GFI (ground fault
interrupter) single- and
two-pole protection
through 50 A
Volume 1—Residential and Light Commercial CA08100002E—March 2019 www.eaton.com V1-T5-5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5.2
Power Pedestals
Temporary Power/RV Park
Two Styles to Meet Your
Power Outlet Needs
Surface mount: User
mounts unit to a post
Pedestal mount:
User mounts with an
underground pedestal
extension or pad-mounting
bracket. (Underground
pedestal extension and
pad-mounting bracket are
sold separately. See
accessories Page V1-T5-7
for part numbers and
options)
Compact Design Available in Certain
Configurations for Added Convenience
Standards and Certifications
UL Standard 231
UL File Number E163588
Receptacles conform to
NEMA and/or ANSI
configurations as specified
by the NEC.
Standard Compliance
All power outlet panels for
temporary construction site
power and RV (recreational
vehicle) application shall be
UL listed for the U.S. per UL
Standard 231, File E163588.
Receptacles shall conform
to NEMA and/or ANSI
configurations as specified
by the National Electrical
Code (NEC).
Surface Units
Pedestal Units
Lighted option for site
location and nighttime
panel operations
Three-point mounting
100 percent galvanized
steel with baked-on
polyester powder coating
GFI circuit breakers
available through 50 A
One-piece case back for
metered and unmetered
panels
Unique steel barrier
prevents unauthorized
operation of breakers
when door is closed
and padlocked
Lower deadfront cover
can be removed for easy
routing of incoming wires or
receptacle changeouts
Padlock provisions to prevent
unauthorized entry
Utility grade metering available
for construction site or RV park
applications
Removable upper deadfront
cover for easy incoming wire
connections to breaker terminals
Units are factory wired
and assembled
NEMA 3R construction for
rainproof installation
Door swings up when opening
and allows cords to remain
connected when closed.
Metered units available with
meter on top or on bottom
Units are factory wired
and assembled
100 percent galvanized
steel with baked-on
polyester powder coating
GFI circuit breakers
(single- and two-pole)
available through 50 A
One-piece case back for
metered and unmetered
panels
Removable upper deadfront cover for
easy incoming wire connections to
breaker terminals
Door swings up when
opening and allows
cords to remain connected
when closed
Unique steel barrier prevents
unauthorized operation of breakers
when door is closed and padlocked
Lower deadfront cover can be
removed for easy routing of
incoming wires or receptacle
changeouts
Padlock provisions to prevent
unauthorized entry
Loop-feed lug assembly
with 350 kcmil lugs
included as standard
Pad-mounted bracket
option also available
Pedestal extension available
for underground services
Utility grade metering
available for construction
site or RV park applications
NEMA 3R construction for
rainproof installation
V1-T5-6 Volume 1—Residential and Light Commercial CA08100002E—March 2019 www.eaton.com
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5.2
Power Pedestals
Temporary Power/RV Park
Catalog Number Selection
Notes
1For receptacle configurations, see table below.
2Weather-resistant.
3Weather-resistant/tamper resistant.
Receptacle Configuration
Twist-Lock and Custom Receptacle/Breaker Combinations
150 A, 125/250 V,
three-pole, four-wire, NEMA 14-50R
Two-pole, 50 A breaker
430 A, 125 V,
two-pole, three-wire, NEMA TT-30R
Single-pole, 30 A breaker
720 A, 125 V,
two-pole, three-wire, NEMA 5-20R2GFI
Single-pole, 20 A breaker
220 A, 125 V,
two-pole, three-wire, weather-resistant (WR),
NEMA 5-20R2
Single-pole, 20 A breaker
520 A, 250 V,
two-pole, three-wire, NEMA 6-20R2
Two-pole, 20 A breaker
820 A, 125 V,
two-pole, three-wire,
weather-resistant (WR), NEMA 5-20R2GFI
330 A, 125/250 V,
three-pole, four-wire, NEMA 14-30R
Two-pole, 30 A breaker
620 A, 125 V,
two-pole, three-wire, NEMA 5-20R2
Single-pole, 20 A breaker
920 A, 125 V,
two-pole, three-wire, weather-resistant/
tamper-resistant (WR TR), NEMA 5-20R2GFI
K20 A, 250 V,
two-pole, three-wire, weather-resistant (WR),
NEMA 6-20R2
Two-pole, 20 A breaker
A50 A, 125/250 V,
three-pole, three-wire, NEMA L14-50R
Two-pole, 50 A breaker
D30 A, 125/250 V,
three-pole, four-wire, NEMA L14-30R
Two-pole, 30 A breaker
H20 A, 250 V,
two-pole, three-wire, NEMA L6-20R
Two-pole, 20 A breaker
B50 A, 250 V,
two-pole, three-wire, NEMA L6-50R
Two-pole, 50 A breaker
E30 A, 250 V,
two-pole, three-wire, NEMA L6-30R
Two-pole, 30 A breaker
J20 A, 125 V,
two-pole, three-wire, NEMA L5-20R
Single-pole, 20 A breaker
C50 A, 125 V,
two-pole, three-wire, NEMA L5-50R
Single-pole, 50 A breaker
F30 A, 125 V,
two-pole, three-wire, NEMA L5-30R
Single-pole, 30 A breaker
Metering Type
U= Unmetered
M= Metered-ring
R= Metered-ringless
Receptacle Type
Left Position 1
1 = NEMA 14-50R
2 = NEMA 5-20R2 2
3 = NEMA 14-30R
4 = NEMA TT-30R
5 = NEMA 6-20R2
6 = NEMA 5-20R2
7 = NEMA 5-20R2GFI
8 = NEMA 5-20R2GFI 2
9 = NEMA 5-20R2GFI 3
K = NEMA 6-20R2 2
A = NEMA L14-50R
B = NEMA L6-50R
C = NEMA L5-50R
D = NEMA L14-30R
E = NEMA L6-30R
F = NEMA L5-30R
H = NEMA L6-20R
J = NEMA L5-20R
Blank = No receptacle
Receptacle Type
Right Position 1
See “Receptacle Type
Left Position” for
code selection
Circuit Breaker Type
Position 2
N = Non-ground fault
G = Ground fault
Meter Location
(for Metered
Devices Only)
U = Bottom
location
Blank = Top location
Circuit Breaker Type
Position 3
N = Non-ground fault
G = Ground fault
Circuit Breaker Type
Position 1
N = Non-ground fault
G = Ground fault
Eaton’s
Cutler-Hammer®
Series
Receptacle Type
Center Position 1
See “Receptacle Type
Left Position” for
code selection
C H M 1 N 7 N 4 N P X L T Z U
Mounting
S=Surface
P= Pedestal
B= Back-to-back
pedestal
Interior
X = Six circuit
Blank = Standard
Four circuit
Lighting
L=Lighted
Pedestal Extension
TZ= Factory installed
pedestal extension
with lay-in
ground lug
WR
Volume 1—Residential and Light Commercial CA08100002E—March 2019 www.eaton.com V1-T5-7
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5.2
Power Pedestals
Temporary Power/RV Park
Product Selection
When quoting or selecting
a power outlet panel, the
following questions should
be answered:
Unmetered, ring or
ringless style
Number and types of
receptacles (seven
standard and eight
twist-lock options)
Standard or ground
fault breakers
Surface, pedestal or
back-to-back mounting
Are any factory or field
options required?
Power Outlet Panel Receptacle
Configuration Rules
Note: All Power Outlet Panel
Configurations using NEMA
5-20R2 receptacles, including
2 and 6, must be paired with a
ground fault breaker.
Four Receptacles/Unit
All receptacles must
be NEMA 5-20R2 or
NEMA 5-20R2GFI,
surface mount only.
Three Receptacles/Unit
One or more of the
receptacles must be
NEMA 6-20R2,
NEMA 5-20R2 or
NEMA 5-20R2GFI
NEMA 6-20R2,
NEMA 5-20R2, or
NEMA 5-20R2GFI must
go in the second position
If two receptacles consist
of types NEMA 14-50R,
NEMA 10-50R,
NEMA 14-30R or
NEMA 6-20R2 a six-circuit
interior must be added
Example:
CHUIN5N2NSX
Note: Configuration 1 and 2 were
chosen so a six-circuit interior
needs to be added (suffix X) to
the end of the catalog number.
Also, configuration 5 is in the
second position.
Two, One and Zero
Receptacles/Unit
Any configuration.
Accessories
Accessories
Fluorescent Light Kit
Description
Catalog
Number
Underground pedestal extension CHPEDEXT
Stainless steel underground pedestal extension CHPEDEXTSS
Pad-mount bracket CHPADEXT
Cable TV and telephone bracket CHTELTV
Rainproof conduit hub 0.75 inch (19.1 mm) DS075H1
Rainproof conduit hub 1.00 inch (25.4 mm) DS100H1
Rainproof conduit hub 1.25 inch (31.8 mm) DS125H1
Rainproof conduit hub 1.50 inch (38.1 mm) DS150H1
Description
Catalog
Number
Converts power outlet panel to lighted unit, must also order CHOUTCVRL CHFLGTKIT
Underground Pedestal
Extension
Pad-Mount Bracket
DS Hub
Cable TV/Telephone
Bracket
Fluorescent Light Kit
V1-T5-8 Volume 1—Residential and Light Commercial CA08100002E—March 2019 www.eaton.com
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5.2
Power Pedestals
Temporary Power/RV Park
Renewal Parts
Renewal Parts
Description
Catalog
Number
See this volume, Tab 1, section 1.2
Ring style replacement meter socket CHPOPMSRING
Ringless style replacement meter socket CHPOPMSRL
5th jaw kit ARP00035CHJ
Horn bypass (one lug cap per kit; four kits required per device) ARP00777CH
Bonding strap and mounting hardware CHBONDST
Inner lens for lighted power outlet panels CHINLENS
Loop feed lug assembly for single pedestal CHLOOPFDP
Loop feed lug assembly for back-to-back pedestal CHLOOPFDB
Blank lower deadfront cover CHLDFCVR
Lower deadfront cover with duplex receptacle opening CHLDFCVR1
Lower deadfront cover with duplex, duplex receptacle opening CHLDFCVR2
Lower deadfront cover with duplex, duplex, duplex receptacle opening CHLDFCVR3
Lower deadfront cover with rectangle receptacle opening CHLDFCVR4
Lower deadfront cover with rectangle, rectangle receptacle opening CHLDFCVR5
Lower deadfront cover with rectangle, rectangle, rectangle receptacle opening CHLDFCVR6
Lower deadfront cover with duplex, rectangle receptacle opening CHLDFCVR7
Lower deadfront cover with duplex, rectangle, duplex receptacle opening CHLDFCVR8
Lower deadfront cover with rectangle, rectangle, duplex receptacle opening CHLDFCVR9
Lower deadfront cover with round receptacle opening CHLDFCVR10
Lower deadfront cover with round, round receptacle opening CHLDFCVR11
Lower deadfront cover with round, duplex receptacle opening CHLDFCVR12
Meter Socket
Bonding Strap and
Mounting Hardware
Lower Deadfront Cover
Inner Lens
Circuit Breaker
(BR/GFTCB)
Loop Feed
Lug Assembly
Volume 1—Residential and Light Commercial CA08100002E—March 2019 www.eaton.com V1-T5-9
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5.2
Power Pedestals
Temporary Power/RV Park
Renewal Parts, continued
Description
Catalog
Number
Lower deadfront cover with round, duplex, duplex receptacle opening CHLDFCVR13
Lower deadfront cover with round, duplex, round receptacle opening CHLDFCVR14
Lower deadfront cover with round, rectangle receptacle opening CHLDFCVR15
Lower deadfront cover with round, rectangle, rectangle receptacle opening CHLDFCVR16
Lower deadfront cover with round, rectangle, round receptacle opening CHLDFCVR17
Lower deadfront cover with round, rectangle, duplex receptacle opening CHLDFCVR18
Upper deadfront cover with six breaker twistouts CHUDFCVR
Upper deadfront cover with provisions for lighted option CHUDFCVRL
Outer door CHOUTCVR
Outer door with lens CHOUTCVRL
Six-hole neutral assembly with 2/0 lug CHNEUT
Seven-hole neutral assembly with 2/0 lug CHNEUT1
Five-hole ground bar kit GBK5
10-hole ground bar kit GBK10
Replacement Meter Cover
Replacement meter cover—ring type CHPOPRMC
Replacement meter cover—ringless CHPOPRLMC
Replacement meter cover—ringless CHPOPRLMCN
Replacement meter cover—ringless CHPOPRLMCN2
Upper Deadfront Cover
Outer Door with Lens
Outer Door
Neutral Assemblies
V1-T5-10 Volume 1—Residential and Light Commercial CA08100002E—March 2019 www.eaton.com
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5.2
Power Pedestals
Temporary Power/RV Park
Power Outlet Panels
Contents
Description Page
Product Description . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-2
Surface Units
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-13
Pedestal Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-16
Surface Units
Product Overview
A power outlet panel (or POP)
is a device designed for
outdoor service to meet
temporary power
requirements at construction
sites and recreation vehicle
(RV) parks. POPs provide a
safe and reliable means for
users to access electricity
at such locations.
Product Selection
Power Outlet Panel Receptacle Configuration Rules
Note: All Power Outlet Panel
Configurations using NEMA
5-20R2 receptacles, including
2 and 6, must be paired with a
ground fault breaker.
See Page V1-T5-7 for
complete list.
Four Receptacles/Unit
All receptacles must be
NEMA 5-20R2 and/or
NEMA 5-20R2GFI, surface
mount only.
Three Receptacles/Unit
One or more of the
receptacles must be
NEMA 6-20R2,
NEMA 5-20R2 or
NEMA 5-20R2GFI
NEMA 6-20R2,
NEMA 5-20R2, or
NEMA 5-20R2GFI must
go in the second position
If two receptacles consist
of types NEMA 14-50R,
NEMA 10-50R,
NEMA 14-30R or
NEMA 6-20R2 a six-circuit
interior must be added
Example:
CHUIN5N2NSX
Note: Configuration 1 and 2 were
chosen so a six-circuit interior
needs to be added (suffix X) to
the end of the catalog number.
Also, configuration 5 is in the
second position.
Two, One and Zero
Receptacles/Unit
Any configuration.
Options
Six-circuit interior
Factory-mounted
pedestal extension
Lighted
Bottom fed
Volume 1—Residential and Light Commercial CA08100002E—March 2019 www.eaton.com V1-T5-11
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5.2
Power Pedestals
Temporary Power/RV Park
Surface Type
Notes
1 The “X” suffix indicates that a six circuit interior is provided, instead of the standard four circuit interior.
2 Includes 60 A two-pole main breaker for service disconnect ratings.
Contact your local Eaton sales office for configurations not listed.
Ampere
Series
Receptacle Description Breaker Description
Catalog
Number
Position
1st 2nd 3rdLeft Center Right
Unmetered Single Receptacle
50 14-50R No breaker No breaker No breaker CHU1S
30 14-30 R No breaker No breaker No breaker CHU3S
30 TT-30R No breaker No breaker No breaker CHU4S
20 6-20R2 No breaker No breaker No breaker CHU5S
20 5-20R2 No breaker No breaker No breaker CHU6S
20 5-20R2GFI No breaker No breaker No breaker CHU7S
Unmetered
20/20/20 5-20R2 5-20R2 6-20R2 GFI GFI GFI CHU6G6G5GS
20/20/20 5-20R2WR 5-20R2WR 6-20R2WR GFI GFI GFI CHU2G2GKGS
20/20/20 5-20R2GFI 5-20R2GFI 6-20R2 Non-GFI Non-GFI Non-GFI CHU7N7N5NS
20/20/20 5-20R2GFIWR 5-20R2GFIWR 6-20R2WR Non-GFI Non-GFI Non-GFI CHU8N8NKNS
20/20/20 5-20R2GFI 5-20R2GFI 6-20R2 Non-GFI Non-GFI GFI CHU7N7N5GS
20/20/20 5-20R2GFIWR 5-20R2GFIWR 6-20R2WR Non-GFI Non-GFI GFI CHU8N8NKGS
50/20/30 14-50R 5-20R2GFI TT-30R Non-GFI Non-GFI Non-GFI CHU1N7N4NS
50/20/30 14-50R 5-20R2GFI 6-20R GFI Non-GFI Non-GFI CHU1G7N7NS
50/20 14-50R 5-20RGFI GFI Non-GFI CHU1G7NS
50/20 14-50R 5-20RGFI Non-GFI Non-GFI CHU1N7NS
50/20/50 14-50R 5-20R2GFI 14-50R Non-GFI Non-GFI Non-GFI CHU1N7N1NSX 1
30/30/20 TT-30R 5-20R2GFI TT-30R Non-GFI Non-GFI Non-GFI CHU4N7N4NS
20/20/20 5-20R2 5-20R2 6-20R2 GFI GFI GFI CHU6G6G5GS6OM 2
Unmetered (Compact Version)
50 14-50R Non-GFI CHU1NS
20 5-20R2 Non-GFI CHU2NS
30 TT-30R GFI CHU4GS
30/30 TT-30R TT-30R Non-GFI Non-GFI CHU4N4NS
30/20 TT-30R 5-20R2GFI Non-GFI Non-GFI CHU4N7NS
30 TT-30R Non-GFI CHU4NS
20 6-20R2 GFI CHU5GS
20/20 5-20R2 5-20R2 GFI GFI CHU6G6GS
20 5-20R2 GFI CHU6GS
20/20 5-20R2GFI 5-20R2GFI Non-GFI Non-GFI CHU7N7NS
20 5-20R2GFI Non-GFI CHU7NS
Single Receptacle
CHU4S
Unmetered Type
CHU1N7N4NS
Unmetered
(Compact Version)
V1-T5-12 Volume 1—Residential and Light Commercial CA08100002E—March 2019 www.eaton.com
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5.2
Power Pedestals
Temporary Power/RV Park
Surface Type, continued
Accessories
See Page V1-T5-7.
Ampere
Series
Receptacle Description Breaker Description
Catalog
Number
Position
1st 2nd 3rdLeft Center Right
Metered—Ring
50/20/20 14-50R 5-20R2GFI 5-20R2GFI GFI Non-GFI Non-GFI CHM1G7N7NS
20/20 5-20R2GFI 5-20R2GFI Non-GFI Non-GFI CHM7N7NS
20/20/20 5-20R2GFI 5-20R2GFI 6-20R2 Non-GFI Non-GFI GFI CHM7N7N5GS
20/20/20 5-20R2GFI 5-20R2GFI 6-20R2 Non-GFI Non-GFI Non-GFI CHM7N7N5NS
50/30/20 14-50R 5-20R2GFI TT-30R Non-GFI Non-GFI Non-GFI CHM1N7N4NS
50/20 14-50R 5-20R2GFI Non-GFI Non-GFI CHM1N7NS
20/20 6-20R2 5-20R2GFI Non-GFI Non-GFI Non-GFI CHM5N7NS
Metered—Ringless
50/20 14-50R 5-20R2GFI GFI Non-GFI CHR1G7NS
20/20 5-20R2GFI 5-20R2GFI Non-GFI Non-GFI CHR7N7NS
50/20/20 14-50R 5-20R2GFI 5-20R2GFI GFI Non-GFI Non-GFI CHR1G7N7NS
50/20 14-50R 5-20R2GFI Non-GFI Non-GFI CHR1N7NS
20/20/20 5-20R2GFI 5-20R2GFI 5-20R2GFI Non-GFI Non-GFI Non-GFI CHR7N7N7NS
20/20/20 5-20R2WR 5-20R2WR 6-20R2WR GFI GFI GFI CHR2G2GKGS
30/20/20 14-30R 5-20R2GFI 5-20R2GFI Non-GFI Non-GFI Non-GFI CHR3N7N7NS
50/30/20 14-50R 5-20R2GFI TT-30R Non-GFI Non-GFI Non-GFI CHR1N7N4NS
Metered—Ring—Bottom Fed
20/20 5-20R2GFI 5-20R2GFI Non-GFI Non-GFI CHM7N7NSU
20/20/20 5-20R2GFI 5-20R2GFI 6-20R2 Non-GFI Non-GFI GFI CHM7N7N5GSU
50/20/20 14-50R 5-20R2GFI 5-20R2GFI GFI Non-GFI Non-GFI CHM1G7N7NSU
Metered—Ringless—Bottom Fed
20/20 5-20R2GFI 5-20R2GFI Non-GFI Non-GFI CHR7N7NSU
50/20 14-50R 5-20R2GFI GFI Non-GFI CHR1G7NSU
50/20 10-50R 5-20R2GFI GFI Non-GFI CHR2G7NSU
20/20/20 5-20R2WR 5-20R2WR 6-20R2WR GFI GFI GFI CHR2G2GKGSU
20/20/20 5-20R2GFI 5-20R2GFI 6-20R2 Non-GFI Non-GFI GFI CHR7N7N5GSU
20/20/20 5-20R2GFI 5-20R2GFI 6-20R2 Non-GFI Non-GFI Non-GFI CHR7N7N5NSU
20/20/20 5-20R2GFI 5-20R2GFI 5-20R2GFI Non-GFI Non-GFI Non-GFI CHR7N7N7NSU
30/20/20 14-30R 5-20R2GFI 5-20R2GFI Non-GFI Non-GFI Non-GFI CHR3N7N7NSU
30/20/20 14-30R 5-20R2GFI 5-20R2GFI GFI Non-GFI Non-GFI CHR3G7N7NSU
50/20/20 14-50R 5-20R2GFI 5-20R2GFI GFI Non-GFI Non-GFI CHR1G7N7NSU
50/20/30 14-50R 5-20R2GFI TT-30R Non-GFI Non-GFI Non-GFI CHR1N7N4NSU
Metered Ringless Type
CHR4N7NS
Metered Ring or
Ringless Type
Bottom Feed
Metered Ring
CHM1G7NS
Volume 1—Residential and Light Commercial CA08100002E—March 2019 www.eaton.com V1-T5-13
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5.2
Power Pedestals
Temporary Power/RV Park
Dimensions
Approximate Dimensions in Inches (mm)
Single Receptacle
6.58
(167.1)
2.63
(66.8)
0.24
(6.1)
7. 1 0
(108.3)
4.50
(114.3)
1.30
(33.0)
6.23
(158.2)
2.50
(63.5)
1.87
(47.5 )
3.18
(80.8)
4.79
(121.7)
4.27
(108.5) 0.13
(3.3)
V1-T5-14 Volume 1—Residential and Light Commercial CA08100002E—March 2019 www.eaton.com
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5.2
Power Pedestals
Temporary Power/RV Park
Approximate Dimensions in Inches (mm)
Compact Design Option
Unmetered Units
Unmetered Surface Type
6.94
(176.3)
6.58
(167.1)
11.66
(296.2)
0.30
(7.62)
Center Line
for Receptacle
4.27
(108.5) 0.13
(3.3)
7.26
(184.4)
2.43
(61.7)
4.89
(124.2)
1.89
(48.0) 2.14
(54.4)
Locking
Provision
9.50
(241.3)
17.10
(434.3)
6.70
(170.2) 1.30
(33.0)
14.50
(368.3)
4.30
(109.2) 0.07
(1.7)
Volume 1—Residential and Light Commercial CA08100002E—March 2019 www.eaton.com V1-T5-15
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5.2
Power Pedestals
Temporary Power/RV Park
Approximate Dimensions in Inches (mm)
Metered Units (Ring and Ringless)
Metered Surface Type
Bottom Fed Type
Sealing
Provision
Locking
Provision
9.50
(241.3)
22.50
(571.5)
30.00
(762.0)
4.50
(114.3)
0.07
(1.7)
4.30
(109.2)
6.70
(170.1)
9.49
(241.1)
30.10
(764.6)
Sealing
Provision
6.15
(156.2)
17.11
(434.7) 12.97
(329.4)
4.93
(125.2)
Locking
Provision
6.80
(172.8)
4.31
(109.5) 0.06
(1.6)
V1-T5-16 Volume 1—Residential and Light Commercial CA08100002E—March 2019 www.eaton.com
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5.2
Power Pedestals
Temporary Power/RV Park
Power Outlet Panels
Contents
Description Page
Product Description . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-2
Surface Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-10
Pedestal Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-16
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-18
Pedestal Units
Product Overview
A power outlet panel (or POP)
is a device designed for
outdoor service to meet
temporary power
requirements at construction
sites and recreation vehicle
(RV) parks. POPs provide a
safe and reliable means for
users to access electricity
at such locations.
Product Selection
Power Outlet Panel Receptacle Configuration Rules
Note: All Power Outlet Panel
Configurations using NEMA
5-20R2 receptacles, including
2 and 6, must be paired with a
ground fault breaker.
See Page V1-T5-7 for
complete list.
Four Receptacles/Unit
All receptacles must be
NEMA 5-20R2 and/or
NEMA 5-20R2GFI, surface
mount only.
Three Receptacles/Unit
One or more of the
receptacles must be
NEMA 6-20R2,
NEMA 5-20R2 or
NEMA 5-20R2GFI
NEMA 6-20R2,
NEMA 5-20R2, or
NEMA 5-20R2GFI must
go in the second position
If two receptacles consist
of types NEMA 14-50R,
NEMA 10-50R,
NEMA 14-30R or
NEMA 6-20R2 a six-circuit
interior must be added
Example:
CHUIN5N2NSX
Note: Configuration 1 and 2 were
chosen so a six-circuit interior
needs to be added (suffix X) to
the end of the catalog number.
Also, configuration 5 is in the
second position.
Two, One and Zero
Receptacles/Unit
Any configuration.
Options
Six-circuit interior
Factory-mounted
pedestal extension
Lighted
Bottom fed
Volume 1—Residential and Light Commercial CA08100002E—March 2019 www.eaton.com V1-T5-17
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5.2
Power Pedestals
Temporary Power/RV Park
Pedestal Type
Back-to-Back Pedestal Type
Notes
1 The pedestal back-to-back units have receptacles and circuit breakers as shown for each panel and share one common pedestal with loop feed lugs.
Contact your local Eaton sales office for configurations not listed.
Accessories
See Page V1-T5-7.
Ampere
Series
Receptacle Description Breaker Description
Catalog
Number
Position
1st 2nd 3rdLeft Center Right
Unmetered
50/30/20 14-50R 5-20R2GFI TT-30R Non-GFI Non-GFI Non-GFI CHU1N7N4NP
30/20 TT-30R 5-20R2GFI Non-GFI Non-GFI CHU4N7NP
50/30/20 14-50R 5-20R2GFI TT-30R Non-GFI Non-GFI Non-GFI CHU1N7N4NPTZ
30/30/20 TT-30R 5-20R2GFI TT-30R Non-GFI Non-GFI Non-GFI CHU4N7N4NP
30/20 TT-30R 5-20R2GFI Non-GFI Non-GFI CHU4N7NPTZ
Metered—Ring
50/30/20 14-50R 5-20R2GFI TT-30R Non-GFI Non-GFI Non-GFI CHM1N7N4NP
50/20 14-50R 5-20R2GFI Non-GFI Non-GFI CHM1N7NP
50/30/20 14-50R 5-20R2GFI TT-30R Non-GFI Non-GFI Non-GFI CHM1N7N4NPTZ
30/20 TT-30R 5-20R2GFI Non-GFI Non-GFI CHM4N7NPTZ
Metered—Ringless
50/30/20 14-50R 5-20R2GFI TT-30R Non-GFI Non-GFI Non-GFI CHR1N7N4NP
50/20/50 14-50R 5-20R2GFI 14-50R Non-GFI Non-GFI Non-GFI CHR1N7N1NPX
50/20/30 14-50R 5-20R2GFI 14-30R Non-GFI Non-GFI Non-GFI CHR1N7N3NPX
50/20/30 14-50R 5-20R2 14-30R Non-GFI Ground fault Non-GFI CHR1N6G3NPX
Ampere
Series
Receptacle Description Breaker Description
Catalog
Number
Position
1st 2nd 3rdLeft Center Right
Unmetered 1
30/30/20 TT-30R 5-20R2GFI TT-30R Non-GFI Non-GFI Non-GFI CHU4N7N4NB
50/30/20 14-50R 5-20R2GFI TT-30R Non-GFI Non-GFI Non-GFI CHU1N7N4NBTZ
Metered—Ring 1
30/20 TT-30R 5-20R2GFI Non-GFI Non-GFI CHM4N7NB
50/30/20 14-50R 5-20R2GFI TT-30R Non-GFI Non-GFI Non-GFI CHM1N7N4NB
Metered—Ringless 1
50/30/20 14-50R 5-20R2GFI TT-30R Non-GFI Non-GFI Non-GFI CHR1N7N4NBTZ
Unmetered Type
CHM1N7N4NPTZ
CHU1N7N4NBTZ
V1-T5-18 Volume 1—Residential and Light Commercial CA08100002E—March 2019 www.eaton.com
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5.2
Power Pedestals
Temporary Power/RV Park
Dimensions
Approximate Dimensions in Inches (mm)
Metered Units
100 A Pedestal
ÿ2.50
(63.5)
Gasket
CURRENT INTERRUPTING RATING
AT 120/240 VOLTS AC
10,000
MAX. RMS SYM. AMPERES
STRIP
.438
100A
1"
100A100A
100A100A
1" 1"
1" 1"
100A
1"
.63
(15.9)
100A 100A
Ringless
U.G. Feed Pedestal-Mount
Sections Through at
Meter Socket
6.10
(154.9)
33.00
(838.2)
18.02
(457.7)
Secondary
Hit Exit
Hole B/B
Only
A N B
7.44
(188.9)
ÿ1.50
10.24
(260.0)
3.077
4.108
4.00
(101.6)
.12
(3.1)
10.78
(273.7)
.904
4.46
(113.3)
ÿ2.500
Sections Through
At Upper Barrier
Sections Through
At Lower Barrier
.79
(20.1)
4.00
(101.6)
.92 (23.4)
33.00
(838.2)
Volume 1—Residential and Light Commercial CA08100002E—March 2019 www.eaton.com V1-T5-19
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5.2
Power Pedestals
Temporary Power/RV Park
Approximate Dimensions in Inches (mm)
Metered Units (Ring and Ringless)
Metered Back-to-Back Pedestal Type
Bottom Fed Type
0.75
(19.1)
9.49
(241.1)
30.10
(764.6)
Sealing
Provision
6.15
(156.2)
17.11
(434.7) 12.97
(329.4)
4.93
(125.2)
Locking
Provision
6.80
(172.8)
4.31
(109.5) 0.06
(1.6)
V1-T5-20 Volume 1—Residential and Light Commercial CA08100002E—March 2019 www.eaton.com
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5.2
Power Pedestals
Te m p ora r y Pow er/ R V Pa r k
Approximate Dimensions in Inches (mm)
Unmetered Back-to-Back Pedestal Type
Unmetered Pedestal Type Metered Pedestal Type
Locking
Provision
13.60
(345.4)
8.60 (218.4)
19.20
(487.7)
3.30
(83.8)
0.75
(19.1)
9.50
(241.3)
39.90
(1013.5)
39.10
(993.1)
9.40
(238.8)
9.20
(233.7)
Sealing
Provision
Locking
Provision
9.50
(241.3)
52.00
(1320.8)
25.80
(655.3)
16.90
(429.3)
44.50
(1130.3)
22.00
(558.8)
6.80
(172.7)
5.00
(127.0) 4.30
(109.2)
Volume 1—Residential and Light Commercial CA08100002E—March 2019 www.eaton.com V1-T5-21
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5.3
Power Pedestals
Mobile Home Panels
Power Outlet Panels
Contents
Description Page
Mobile Home Panels
Catalog Number Selection . . . . . . . . . . . . . . . . V1-T5-22
Product Selection . . . . . . . . . . . . . . . . . . . . . . . V1-T5-22
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-23
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-24
Product Overview
Eaton’s versatile Mobile
Home Panels have a user-
friendly design that allows for
a faster, cleaner installation.
100 and 200 A panels come
complete with the main
breaker and a 4/8 or 8/16
interior, respectively. The
200 A units are designed with
ample width to ensure plenty
of room for wire bending and
an easier installation.
Receptacle Deadfront Kits
Optional receptacle
deadfront kits enable the
field installation of contractor
supplied receptacles and
breakers that can supply
power for a variety of
applications including:
Visiting RVs
Temporary power
Lawn equipment
Air compressors
Anything else that requires
cord-connected power
Features
Fastenerless Socket Design
Eliminates overheating
caused by loose socket
connections
Pedestal Unit
Convenient and sturdy
ground mounting
Loop feed feature allows
several units to be
connected in series
Easier, Better and
Faster Installation
More wire bending and
viewing room
Additional circuits mean
more flexibility
V1-T5-22 Volume 1—Residential and Light Commercial CA08100002E—March 2019 www.eaton.com
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5.3
Power Pedestals
Mobile Home Panels
Catalog Number Selection
Mobile Home Panels
Product Selection
Mobile Home Panels 1
Note
1 Pedestal Extension included with Mobile Home Panels.
Amperes Security Interior Main
Branch
Breakers Mounting Receptacles
Catalog
Number
100 Ring 4/8 BR2100 BR Pedestal None MHM100P
100 Ring 4/8 BR2100 BR Back-to-back None MHM100B
100 Ringless 4/8 BR2100 BR Pedestal None MHR100P
100 Ringless 4/8 BR2100 BR Back-to-back None MHR100B
150 Ring 8/16 CSR2150 BR Pedestal None MHM150P
150 Ring 8/16 CSR2150 BR Back-to-back None MHM150B
150 Ringless 8/16 CSR2150 BR Pedestal None MHR150P
150 Ringless 8/16 CSR2150 BR Back-to-back None MHR150B
200 Ring 8/16 CSR2200 BR Pedestal None MHM200P
200 Ring 8/16 CSR2200 BR Back-to-back None MHM200B
200 Ringless 8/16 CSR2200 BR Pedestal None MHR200P
200 Ringless 8/16 CSR2200 BR Back-to-back None MHR200B
200 Ringless 8/16 CSR2200 BR Pedestal Qty 1 14-50R
Qty 2 TT-30R
MHM200P1N4N4N
Amperes
100
150
200
Type
MH = Mobile Home Panel
Metering Type
M= Metered-ring
R= Metered-ringless
Mounting
P= Pedestal
B= Back-to-back
Optional Receptacle Type
Position 1
1 = NEMA 14-50R
3 = NEMA 14-30R
4 = NEMA TT-30R
5 = NEMA 6-20R2
6 = NEMA 5-20R2
7 = NEMA 5-20R2GFI
8 = NEMA 5-20R2GFI (WR)
9 = NEMA 5-20R2GFI (WR/TR)
Blank = No receptacle
Circuit Breaker Type
Position 1
N = Non-ground fault
G = Ground fault Optional Receptacle Type
Position 2
1 = NEMA 14-50R
3 = NEMA 14-30R
4 = NEMA TT-30R
5 = NEMA 6-20R2
6 = NEMA 5-20R2
7 = NEMA 5-20R2GFI
8 = NEMA 5-20R2GFI (WR)
9 = NEMA 5-20R2GFI (WR/TR)
Blank = No receptacle
Circuit Breaker Type
Position 2
N = Non-ground fault
G = Ground fault
MH M100 P 1 N 4 N
Mobile Home Panel
Volume 1—Residential and Light Commercial CA08100002E—March 2019 www.eaton.com V1-T5-23
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5.3
Power Pedestals
Mobile Home Panels
Mobile Home Panel Deadfronts for 200 A Units 1
Available Receptacle Deadfront Kits—Receptacles and
Breakers Not Included
Accessories
Mobile Home Panels
Hubs not used on mobile home panels.
Note
1For 100 A units, the accessory Catalog Number would be MHD1___. For example, to order
a deadfront to accept one 30 A receptacle (round) in a 100 ampere device, the Catalog
Number would be MHD1X.
Description Amperes
Catalog
Number
Direct feed kit MHDFK
Pedestal extension 200 MHPEDEXT
Stainless steel pedestal extension 200 MHPEDEXTSS
Padmount adapter 200 MHPADEXT
Padmount adapter 100 CHPADEXT100
V1-T5-24 Volume 1—Residential and Light Commercial CA08100002E—March 2019 www.eaton.com
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5.3
Power Pedestals
Mobile Home Panels
Dimensions
Approximate Dimensions in Inches (mm)
Mobile Home Panel—Ringless—Pedestal Mounting
ON
OFF
ON
OFF
Grade Level
5.31
(134.8)
5.98
(152.0) 14.45
(367.0)
27.87
(708.0)
28.01
(711.5) 23.69
(601.8)
50.08
(1272.1)
Ringless
Socket
Rated 200 A
Continuous
200A
Main
Breaker
57.81
(1468.3)
Sealing
Provision
1-1/4, 1-1/2,
2, 2-1/2
(31.8, 38.1,
50.8, 63.5)
Knockout
1, 1-1/4, 1-1/2, 2
(25.4, 31.8, 38.1, 50.8)
Knockout
5/16 (7.9)
Diameter KO
Opposite
Side Only
43.20
(1097.4)
28.70
(729.0)
1.21
(30.7)
2.00
(50.8)
24.65
(626.1)
Optional Direct
Feed Kit
Shown Installed
(Cover Not Shown)
Door Not
Shown
Bottom Endwall
Direct Feed Kit
1/2, 3/4,1
(12.7, 19.1, 25.4)
KO (2 Required)
1, 1-1/4, 1-1/2, 2
(25.4, 31.8, 38.1,
50.8) KO
1/2, 3/4, 1, 1-1/4,
1-1/2 (12.7, 19.1,
25.4, 31.8, 38.1) KO
Sealing Provision
Volume 1—Residential and Light Commercial CA08100002E—March 2019 www.eaton.com V1-T5-25
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5.3
Power Pedestals
Mobile Home Panels
Approximate Dimensions in Inches (mm)
Mobile Home Panel—Ringless—Back-to-Back Mounting
Sealing
Provision
Door
Not
Shown
ON
OFF
ON
OFF
ON
OFF
ON
OFF
12.09
(307.2) 10.75
(272.9)
27.87
(708.0)
22.01
(711.5) 18.69
(474.6)
25.00
(635.0)
Front View
Optional Direct
Feed Kit Shown
Installed
(Cover Not
Shown)
200A
Main
Breaker
Sealing
Provision
1-1/4, 1-1/2,
2, 2-1/2
(31.8, 38.1,
50.8, 63.5)
Knockout
5/16 (7.9)
Diameter
KO Opposite
Side Only 5/16 (7.9)
Diameter
KO
Opposite
Side Only
1,1-1/4,
1-1/2, 2
(25.4, 31.8,
38.1, 50.8)
Knockout
Grade Level
Door Not
Shown
23.69
(601.8)
50.08
(1272.1)
57.81
(1468.3)
43.20
(1097.4)
28.70
(729.0)
1.21
(30.7)
2.00
(50.8)
14.45
(367.0)
Bottom Endwall Direct Feed Kit
1/2, 3/4, 1 (12.7,
19.1, 25.4) KO
(2) Required
1/2, 3/4, 1, 1-1/4, 1-1/2
(12.7, 19.1, 25.4, 31.8,
38.1) KO
1, 1-1/4, 1-1/2, 2
(25.4, 31.8, 38.1, 50.8) KO
Bottom Endwall Back Unit
1-1/2, 2, 2-1/2, 3
(38.1, 50.8, 63.5, 76.2) KO
5/16 (7.9) Diameter
KO (3) Required
1/2 (12.7) KO
(3) Required
3/4, 1 (19.1, 25.4) KO
1-1/4, 1-1/2, 2, 2-1/2
(31.8, 38.1, 50.8, 63.5) KO
(2) Required
1/2, 3/4 (12.7, 19.1)
KO (2) Required
Ringless
Socket
Rated 200 A
Continuous
Back View
V1-T5-26 Volume 1—Residential and Light Commercial CA08100002E—March 2019 www.eaton.com
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5.3
Power Pedestals
Mobile Home Panels
Approximate Dimensions in Inches (mm)
Mobile Home Panel—Ring—Pedestal Mounting
ON
OFF
ON
OFF
Ring Type Socket
Rated 200 A Continuous
200A
Main
Breaker
Door
Not
Shown
5/16 (7.9)
Diameter
KO
Opposite
Side Only
1-1/4,
1-1/2, 2,
2-1/2
(31.8, 38.1,
50.8, 63.5)
Knockout
Sealing
Provision
24.64
(626.0)
Optional Direct Feed Kit
Shown Installed
(Cover Not Shown)
28.01
(711.5)
1, 1-1/4,
1-1/2, 2
(25.4,
31.8, 38.1,
50.8) KO
1/2, 3/4, 1 (12.7,
19.1, 25.4) KO
(2 Required)
Bottom Endwall
Direct Feed Kit
1/2, 3/4, 1, 1-1/4,
1-1/2 (12.7, 19.1,
25.4, 31.8, 38.1) KO
1, 1-1/4, 1-1/2,
2 (25.4, 31.8,
38.1, 50.8) KO
Grade Level
27.87
(708.0) 23.69
(601.8)
50.08
(1272.1)
57.81
(1468.3)
28.70
(729.0)
1.21
(30.7)
2.00
(50.8)
5.56
(141.3) 5.31
(134.8)
43.20
(1097.4)
14.45
(367.0)
Volume 1—Residential and Light Commercial CA08100002E—March 2019 www.eaton.com V1-T5-27
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5.3
Power Pedestals
Mobile Home Panels
Approximate Dimensions in Inches (mm)
Mobile Home Panel—Ring—Back-to-Back Mounting
ON
OFF
ON
OFF
Grade Level
1-1/4,
1-1/2, 2,
2-1/2
(31.8,
38.1, 50.8,
63.5)
Knockout
1, 1-1/4, 1-1/2, 2
(25.4, 31.8,
38.1, 50.8)
Knockout
Sealing Provision
5/16 (7.9)
Diameter KO
Back View Front View
1-1/4, 1-1/2, 2, 2-1/2
(31.8, 38.1, 50.8, 63.5)
KO (2) Required
Bottom Endwall
Back Unit
Bottom Endwall
Direct Feed Kit
1/2, 3/4, 1 (12.7,
19.1, 25.4) KO
(2) Required
1/2, 3/4, 1, 1-1/4,
1-1/2 (12.7, 19.1,
25.4, 31.8, 38.1) KO
1, 1-1/4, 1-1/2, 2 (25.4,
31.8, 38.1, 50.8) KO
1-1/2, 2, 2-1/2, 3 (38.1,
50.8, 63.5, 76.2) KO
3/4, 1 (19.1, 25.4) KO
Optional Direct
Feed Kit
Shown Installed
(Cover Not
Shown)
Door Not
Shown
200A
Main
Breaker
Door
Not
Shown
23.69
(601.8)
50.08
(1272.1)
57.81
(1468.3)
43.20
(1097.4)
28.70
(729.0)
11.25
(285.8) 10.75
(273.0) 14.45
(367.0) Ring Type Socket
Rated 200 A Continuous
27.87
(708.0)
18.69
(474.6)
25.00
(635.0)
22.01
(711.5)
5/16 (7.9) Diameter
KO (3) Required
1/2 (12.7) KO
(3) Required
1/2, 3/4 (12.7, 19.1)
KO (2) Required
V1-T5-28 Volume 1—Residential and Light Commercial CA08100002E—March 2019 www.eaton.com
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5.4
Power Pedestals
RV Park Hook-Ups
High-Quality, Weatherproof Electrical Equipment
Recreational Vehicle/Campground Products
Contents
Description Page
Power Pedestals
Product Selection Guide . . . . . . . . . . . . . . . . . . V1-T5-29
Powerhouse Power Pedestal . . . . . . . . . . . . . . . . . V1-T5-30
Powerhouse—Stainless Steel (SS) Power Pedestal V1-T5-33
Newport Camp Mate Power Pedestal . . . . . . . . . . V1-T5-36
Firehouse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-39
Digital Electronic Kilowatthour Meters. . . . . . . . . . V1-T5-41
Distribution Equipment—Ground Fault Monitor. . . V1-T5-42
Distribution Equipment—Substations . . . . . . . . . . V1-T5-43
Distribution Equipment—Panels . . . . . . . . . . . . . . V1-T5-46
Distribution Equipment—Transformers . . . . . . . . . V1-T5-47
Power Pedestals
Product Overview
On March 24, 2006, RV Park
Hook-Ups® joined together
with Eaton to provide
unmatched products and
services in the recreational
vehicle industry, as well as
the marina industry. Known
as the leader in electrical
control, power distribution,
and industrial automation
products and services, Eaton
is a quality driven company
that constantly looks for ways
to provide enhanced products
and service solutions for their
customers. Eaton will be able
to provide RV park developers
a complete electrical solution.
For more information on the
other products available from
Eaton, visit us online at
www.eaton.com or
www.rvparkhookups.com
What Eaton has to Offer
Complementary
comprehensive in-house
electrical designs for your
complete RV or marina
development
RV and marina power
pedestals
Custom substations
Tr a n s fo r m e r s
Panels
Wire
Digital electronic meters
Receptacles and breakers
Specialized electrical parts
and equipment
Volume 1—Residential and Light Commercial CA08100002E—March 2019 www.eaton.com V1-T5-29
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5.4
Power Pedestals
RV Park Hook-Ups
Product Selection Guide
Power Receptacles
Power Outlets Maximum GFI
Side One Side Two Phase Powerhouse Powerhouse–SS Newport Camp Mate
None None 1 2 2 2
3020001221
30–20 30–20 1 2 2
30–30–20 30–30–20 1 2 2
30–20 50–20 1 2 2
30–30–20 50–20 1 2 2
30–30–20 30–50–20 1 2 2
30–30–20 50–50–20 1 2 2
30–50–20 30–50–20 1 2 2
30–50–20 50–50–20 1 2 2
50–20 None 1 2 2
50–20 50–20 1 2 2
50–50–20 50–20 1 2 2
50–50–20 50–50–20 1 2 2
30–50–20 None 1 2 2 0
V1-T5-30 Volume 1—Residential and Light Commercial CA08100002E—March 2019 www.eaton.com
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5.4
Power Pedestals
RV Park Hook-Ups
Powerhouse Power Pedestal
Contents
Description Page
Power Pedestals . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-28
Powerhouse Power Pedestal
Standards and Certifications . . . . . . . . . . . . . . . V1-T5-31
Catalog Number Selection . . . . . . . . . . . . . . . . V1-T5-31
Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-32
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-32
Powerhouse—Stainless Steel (SS) Power Pedestal V1-T5-33
Newport Camp Mate Power Pedestal . . . . . . . . . . V1-T5-36
Firehouse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-39
Digital Electronic Kilowatthour Meters. . . . . . . . . . V1-T5-41
Distribution Equipment—Ground Fault Monitor. . . V1-T5-42
Distribution Equipment—Substations . . . . . . . . . . V1-T5-43
Distribution Equipment—Panels . . . . . . . . . . . . . . V1-T5-46
Distribution Equipment—Transformers . . . . . . . . . V1-T5-47
Powerhouse Power Pedestal
Product Description
The Powerhouse® RV utility
center is our most popular
pedestal for single or double
RV sites because of its full
complement of standard
features and available option
packages able to meet any
user requirement. The
housing is made of durable
weatherproof engineered
resin and will never rust or
deteriorate.
That’s why it comes with a
limited lifetime warranty.
Since the Powerhouse can
accommodate two RV sites,
it’s an economical pedestal
for double site installation.
This unit is ideal for new, or
when retrofitting, full-service
RV parks.
Features
Photocell controlled
13 watt fluorescent light
with amber lens
Lockable weatherproof
doors that protect
receptacles and breakers
Hose and cable brackets
Engineered resin
housing with a two-part
polyurethane coating for a
UV-resistant, long-lasting
finish
Limited lifetime warranty
on the housing
Loop-feed mechanical
busbars that can accept up
to 250 kcmil wire
Hinged pedestal base
providing easy access
for installation and
maintenance
Surge Protection
SurgeTrap is designed
to protect electrical and
electronic loads from
transients and surge
disturbances on your AC
power line, such as voltage
surges, spikes and lighting.
The SurgeTrap has a lifetime
warranty where Eaton will
replace the SurgeTrap device
at no charge.
175 kA maximum
surge current
3500 joules
Type 3R enclosure
Comes with a protection
working indicator light
Factory installed integral
to pedestal or available
for retrofit
Available Options
Clear lens
Photocell controlled single
or dual 7 watt or 13 watt
fluorescent light
Telephone (RJ-11) for
each side
Cable TV for each side
High-speed Internet
connector (RJ-45) for
each side
Water—single or dual
1/4-turn brass ball valves
(brass “T” connection)
with 3/4-inch hose bibs
Water meters with remote
capability
Water—anti-siphon faucet
Loop-feed 3/8-inch stud
lug copper busbar for
up to 250 kcmil wire
(recommended for salt
water environments)
Single-feed mechanical
busbars for up to
250 kcmil wire
Digital electronic meter
for each side
Wireless remote reading of
electronic kilowatt meters
Meter socket for each side
powered (to accept glass
style meter)
Direct burial ground
mounting stand stainless
or galvanized
Custom paint color
Volume 1—Residential and Light Commercial CA08100002E—March 2019 www.eaton.com V1-T5-31
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5.4
Power Pedestals
RV Park Hook-Ups
Standards and Certifications
UL/CSA listed
Catalog Number Selection
Receptacle: R1S1 = Receptacle 1, Side 1
R2S1 = Receptacle 2, Side 1
R3S1 = Receptacle 3, Side 1
R1S2 = Receptacle 1, Side 2
R2S2 = Receptacle 2, Side 2
R3S2 = Receptacle 3, Side 2
Notes
1Number represents the quantity of 1/4-turn ball valves with 3/4-inch hose bibs.
Internet option also available. Contact factory for details.
Type
P= Powerhouse
Z=PHSS
Metering Type
U= Unmetered
1= Digital electronic meters (side 1)
2= Digital electronic meters (side 2)
E= Digital electronic metering (entire pedestal)
B= Digital electronic metering (both sides)
R= Receptacles metered individually (one/rec.)
Lighting and Lens Color
D= LED Amber
I= LED Clear
N= LED Special
F= No lighting Amber
L= No lighting Clear
Y= No lighting Special
Phone Cable TV and Internet Options
Phone
Jack
Cable
TV Jack
Internet
Option
A
B
C
D
E
F
G
H
I
J
K
L
M
N
O
P
Q
R
S
T
U
V
W
X
Y
Z
0
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
1
1
1
1
1
1
1
1
1
2
2
2
2
2
2
2
2
2
0
0
0
0
0
0
0
0
0
0
0
0
1
1
1
2
2
2
0
0
0
1
1
1
2
2
2
2
0
0
1
1
1
2
2
0
0
1
2
0
1
2
0
1
2
0
1
2
0
1
2
0
1
2
2
1
2
0
1
2
0
1
0
P D U 2 0 x x 2 0 x x 2 0 R S
Sides and Receptacles
R1S1
R2S1
R3S1
R4S1
R1S2
R2S2
R3S2
R4S2
0
1
2
4
0
1
2
4
xx0
1
2
4
0
1
2
4
xx
x=None
0=None
1= 20 A GFI duplex
2= 30 A, 125 V
4= 50 A, 125/250 V
Water Option 1
0=0
1=1
2=2
3= Single water meter
4= Dual water meter
5= Single meter for
two valves
Extra Unmetered
GFI Receptacles
0= None
1=1
2=2
Bus
S= Single-phase 3/8-inch copper bus bar
F= Three-phase 3/8-inch copper bus bar
M= Single-phase 300 kcmil mechanical lug bus
Z= Three-phase 300 kcmil mechanical lug bus
L= Single-phase 350 kcmil mechanical lug bus
P= Three-phase 350 kcmil mechanical lug bus
N= Single-phase 1/4-inch copper bus bar
Q= Single-phase 3/8-16-inch copper bus bar
R= Three-phase 3/8-16-inch copper bus bar
T= Single-phase 300 kcmil mechanical lug Canadian bus
U= Single-phase 350 kcmil mechanical lug Canadian bus
V= Single-phase 350 kcmil mechanical lug Canadian bus
W= Three-phase 350 kcmil mechanical lug Canadian bus
V1-T5-32 Volume 1—Residential and Light Commercial CA08100002E—March 2019 www.eaton.com
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5.4
Power Pedestals
RV Park Hook-Ups
Accessories
See Page V1-T5-7.
Dimensions
Approximate Dimensions in Inches (mm)
Powerhouse
To p
Front ViewSide View
Broken View
44.00
(1117.6)
13.75
(349.2)
Volume 1—Residential and Light Commercial CA08100002E—March 2019 www.eaton.com V1-T5-33
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5.4
Power Pedestals
RV Park Hook-Ups
Powerhouse—Stainless Steel (SS) Power Pedestal
Contents
Description Page
Power Pedestals. . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-28
Powerhouse Power Pedestal . . . . . . . . . . . . . . . . . V1-T5-30
Powerhouse—Stainless Steel (SS) Power Pedestal
Catalog Number Selection . . . . . . . . . . . . . . . . V1-T5-34
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-35
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-35
Newport Camp Mate Power Pedestal . . . . . . . . . . V1-T5-36
Firehouse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-39
Digital Electronic Kilowatthour Meters . . . . . . . . . . V1-T5-41
Distribution Equipment—Ground Fault Monitor . . . V1-T5-42
Distribution Equipment—Substations . . . . . . . . . . V1-T5-43
Distribution Equipment—Panels. . . . . . . . . . . . . . . V1-T5-46
Distribution Equipment—Transformers . . . . . . . . . V1-T5-47
Powerhouse—Stainless Steel (SS) Power Pedestal
Product Description
For long-lasting durability
and low maintenance,
the new stainless steel
Powerhouse–SS pedestal
is the most resilient power
center offered.
We have designed a stainless
steel pedestal that will meet
and exceed all applicable
codes and withstand harsh
inland and coastal
environments.
Features
Stainless steel housing
with a limited lifetime
warranty
Photocell controlled
13 watt fluorescent light
with amber lens
Large removable access
panel for easy installation
and maintenance
Weatherproof doors
that protect receptacles
and breakers
Backlit faceplate to aid in
hooking up at night
Hose and cable brackets
Powder-coated finish
Loop-feed mechanical bus
bars that can accept up to
350 kcmil wire
Available Options
Clear lens
Photocell controlled single
or dual 7 watt or 13 watt
fluorescent light
Telephone (RJ-11) for
each side
Cable TV for each side
High-speed Internet
connection (RJ-45) for each
side
Water–single or dual
1/4-turn brass ball valves
(brass “T” connection)
with 3/4-inch hose bibs
Water meters with
remote capability
Water—anti-siphon faucet
Direct burial stainless steel
ground mounting stand
Lockable doors
Loop-feed 3/8-inch stud
lug copper busbar for
up to 350 kcmil wire
(recommended for salt
water environments)
Single-feed mechanical
busbars for up to
350 kcmil wire
Digital electronic metering
for each side
Wireless remote reading of
electronic kilowatt meters
Meter socket for each side
powered (to accept glass
style meter)
Four door design to add
more outlets per pedestal
V1-T5-34 Volume 1—Residential and Light Commercial CA08100002E—March 2019 www.eaton.com
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5.4
Power Pedestals
RV Park Hook-Ups
Catalog Number Selection
Receptacle: R1S1 = Receptacle 1, Side 1
R2S1 = Receptacle 2, Side 1
R3S1 = Receptacle 3, Side 1
R1S2 = Receptacle 1, Side 2
R2S2 = Receptacle 2, Side 2
R3S2 = Receptacle 3, Side 2
Notes
1Number represents the quantity of 1/4-turn ball valves with 3/4-inch hose bibs.
Internet option also available. Contact factory for details.
Extra Unmetered
GFI Receptacles
0= None
1=1
2=2
Water Option 1
0=0
1=1
2=2
3= Single water meter
4= Dual water meter
5= Single meter for
two valves
Type
P= Powerhouse
Z= PHSS
Lighting and Lens Color
D= LED Amber
I= LED Clear
N= LED Special
F= No lighting Amber
L= No lighting Clear
Y= No lighting Special
Bus
S= Single-phase 3/8-inch copper bus bar
F= Three-phase 3/8-inch copper bus bar
M= Single-phase 300 kcmil mechanical lug bus
Z= Three-phase 300 kcmil mechanical lug bus
L= Single-phase 350 kcmil mechanical lug bus
P= Three-phase 350 kcmil mechanical lug bus
N= Single-phase 1/4-inch copper bus bar
Q= Single-phase 3/8-16-inch copper bus bar
R= Three-phase 3/8-16-inch copper bus bar
T= Single-phase 300 kcmil mechanical lug Canadian bus
U= Single-phase 350 kcmil mechanical lug Canadian bus
V= Single-phase 350 kcmil mechanical lug Canadian bus
W= Three-phase 350 kcmil mechanical lug Canadian bus
Phone Cable TV and Internet Options
Phone
Jack
Cable
TV Jack
Internet
Option
A
B
C
D
E
F
G
H
I
J
K
L
M
N
O
P
Q
R
S
T
U
V
W
X
Y
Z
0
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
1
1
1
1
1
1
1
1
1
2
2
2
2
2
2
2
2
2
0
0
0
0
0
0
0
0
0
0
0
0
1
1
1
2
2
2
0
0
0
1
1
1
2
2
2
2
0
0
1
1
1
2
2
0
0
1
2
0
1
2
0
1
2
0
1
2
0
1
2
0
1
2
2
1
2
0
1
2
0
1
0
Z D U 2 0 x x 2 0 x x 2 0 R S
Sides and Receptacles
R1S1
R2S1
R3S1
R4S1
R1S2
R2S2
R3S2
R4S2
0
1
2
4
0
1
2
4
xx0
1
2
4
0
1
2
4
xx
x=None
0=None
1= 20 A GFI duplex
2= 30 A, 125 V
4= 50 A, 125/250 V
Metering Type
U= Unmetered
1= Digital electronic meters (side 1)
2= Digital electronic meters (side 2)
E= Digital electronic metering (entire pedestal)
B= Digital electronic metering (both sides)
R= Receptacles metered individually (one/rec.)
M= One 100 A meter socket (ring-type)
N= One 100 A meter socket (ringless)
V= One meter socket (200 A)
O= Two 100 A meter socket (ring-type)
P= Two 100 A meter socket (ringless)
Volume 1—Residential and Light Commercial CA08100002E—March 2019 www.eaton.com V1-T5-35
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5.4
Power Pedestals
RV Park Hook-Ups
Accessories
See Page V1-T5-7.
Dimensions
Approximate Dimensions in Inches (mm)
PowerhouseStainless Steel (SS)
9.88
(251.0)
40.00
(1016.0)
V1-T5-36 Volume 1—Residential and Light Commercial CA08100002E—March 2019 www.eaton.com
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5.4
Power Pedestals
RV Park Hook-Ups
Newport Camp Mate Power Pedestal
Contents
Description Page
Power Pedestals . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-28
Powerhouse Power Pedestal . . . . . . . . . . . . . . . . . V1-T5-30
Powerhouse—Stainless Steel (SS) Power Pedestal V1-T5-33
Newport Camp Mate Power Pedestal
Catalog Number Selection . . . . . . . . . . . . . . . . V1-T5-37
Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-38
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-38
Firehouse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-39
Digital Electronic Kilowatthour Meters. . . . . . . . . . V1-T5-41
Distribution Equipment—Ground Fault Monitor. . . V1-T5-42
Distribution Equipment—Substations . . . . . . . . . . V1-T5-43
Distribution Equipment—Panels . . . . . . . . . . . . . . V1-T5-46
Distribution Equipment—Transformers . . . . . . . . . V1-T5-47
Newport Camp Mate Power Pedestal
Product Description
The Newport Camp Mate
provides many of the features
and options of our other full-
size pedestals, but in a
compact self-contained unit.
This model provides more
mounting options to RV park
owners than any other model.
It can be mounted to our
stainless steel stand either
flanged or direct burial, a
post or any wall.
It comes standard with a resin
housing that will never rust or
deteriorate and provides area
lighting as well as aiding in
hooking up at night. This unit
is especially suitable to many
RV park renovation projects
as well as new RV parks.
Features
Photocell controlled 7 watt
fluorescent light with
amber lens
Lockable weatherproof
door that protects
receptacles and breakers
Engineered resin housing
Limited lifetime warranty
on the housing
Designed to mount on a
post, wall or an optional
custom stand
Loop-feed 1/4-inch copper
stud lug
busbars that can
accept 2/0 AWG wire
for
Camp Mate without
optional stand
Loop-feed mechanical
busbars that can accept up
to
2/0 AWG
wire for Camp
Mate on optional stand
Available Options
36-inch stainless
steel stand
40-inch stainless steel
pad-mounted stand
60-inch direct burial
stainless steel stand
Telephone (RJ-11)
Cable TV
High-speed Internet
connector (RJ-45)
Water—single or dual
1/4-turn brass ball valves
(brass “T” connection)
with 3/4-inch hose bibs
mounted on optional stand
Water—anti-siphon
backflow preventer
Loop feed 3/8-inch stud lug
copper busbar for up to
350 kcmil wire with stand
(recommended for salt
water environments)
Single-feed mechanical
busbars for up to 350 kcmil
wire available with stand
Digital electronic meter
Wireless remote reading of
electronic kilowatt meter
Meter socket available with
aluminum
stands (to accept
glass style meter)
Standards and Certifications
The Newport Camp Mate is
UL listed and comes with a
limited lifetime warranty on
the housing.
Volume 1—Residential and Light Commercial CA08100002E—March 2019 www.eaton.com V1-T5-37
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5.4
Power Pedestals
RV Park Hook-Ups
Catalog Number Selection
Receptacle: R1 = Receptacle 1
R2 = Receptacle 2
R3 = Receptacle 3
Notes
120 A GFIs not metered.
2Number represents the quantity of 1/4-turn ball valves with 3/4-inch hose bibs (with stand only).
Water
Option 2
0=0
1=1
2=2
Phone Cable TV and Internet Options
Phone
Jack
Cable
TV Jack
Internet
Option
A
B
C
D
E
F
G
H
I
S
T
U
V
W
X
Y
Z
0
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
1
1
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
1
1
1
2
2
2
2
0
0
1
1
1
2
2
0
0
1
2
0
1
2
0
1
2
2
1
2
0
1
2
0
1
0
Stand
0=0
S=Stand
Bus
S= Single-phase 3/8-inch copper bus bar
F= Three-phase 3/8-inch copper bus bar
M= Single-phase 300 kcmil mechanical lug bus
Z= Three-phase 300 kcmil mechanical lug bus
L= Single-phase 350 kcmil mechanical lug bus
P= Three-phase 350 kcmil mechanical lug bus
N= Single-phase 1/4-inch aluminum Canadian bus
O= Single-phase 1/4-inch split bus bar
Q= Single-phase 3/8-16-inch copper bus bar
R= Three-phase 3/8-16-inch copper bus bar
T= Single-phase 300 kcmil mechanical lug Canadian bus
U= Three-phase 300 kcmil mechanical lug Canadian bus
V= Single-phase 350 kcmil mechanical lug Canadian bus
W= Three-phase 350 kcmil mechanical lug Canadian bus
H= Single-phase 1/4-20 stud copper bus bar
I= Three-phase 1/4-20 stud copper bus bar
K= Single-phase 2/0 mechanical lug bus
J= Three-phase 2/0 mechanical lug bus
A= Canadian single-phase 1/4-20 stud copper bus bar
B= Canadian three-phase 1/4-20 stud copper bus bar
C= Canadian single-phase 2/0 mechanical lug
D= Canadian three-phase 2/0 mechanical lug
Sides and
Receptacles
R1S1 R2S1 R3S1
0
1
2
4
0
1
2
4
0
1
0=None
1= 20 A GFI duplex
2= 30 A, 125 V
4= 50 A, 125/250 V
Type
N= NP Harbor Mate
C= NP Camp Mate
Lighting and Lens Color
D= LED Amber
I= LED Clear
N= LED Special
B= LED Blue
F= No lighting Amber
L= No lighting Clear
Y= No lighting Special
P= No lighting Blue
Metering Type 1
U= Unmetered
E= Digital electronic meters
R= Receptacles metered
individually
C D U 2 0 1 S 2 A S
V1-T5-38 Volume 1—Residential and Light Commercial CA08100002E—March 2019 www.eaton.com
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5.4
Power Pedestals
RV Park Hook-Ups
Accessories
See Page V1-T5-72.
Dimensions
Approximate Dimensions in Inches (mm)
Newport Camp Mate
9.18 (233.0)
0.12
(3.2)
10.38
(263.7)
Newport Redesign Newport Redesign With Meters
10.52 (267.2)
9.59 (243.6) 10.38 (263.7)
14.53
(369.0)
13.63
(346.2)
7.44
(189.1)
6.70
(170.2)
3.40
(86.4)
1.68
(42.7)
2.37
(60.3)
4.02
(102.2)
1.54
(39.1)
6.70
(170.2)
3.40
(86.4)
1.68
(42.7)
2.37
(60.3)
4.02
(102.2)
1.54
(39.1)
9.18 (233.0)
0.12
(3.2)
10.38
(263.7)
10.52 (267.2) 7.44
(189.1)
14.53
(369.0)
15.28
(388.0)
10.38 (263.7)
12.88
(327.2)
Volume 1—Residential and Light Commercial CA08100002E—March 2019 www.eaton.com V1-T5-39
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5.4
Power Pedestals
RV Park Hook-Ups
Firehouse
Contents
Description Page
Power Pedestals. . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-28
Powerhouse Power Pedestal . . . . . . . . . . . . . . . . . V1-T5-30
Powerhouse—Stainless Steel (SS) Power Pedestal V1-T5-33
Newport Camp Mate Power Pedestal . . . . . . . . . . V1-T5-36
Firehouse
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-40
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-40
Digital Electronic Kilowatthour Meters . . . . . . . . . . V1-T5-41
Distribution Equipment—Ground Fault Monitor . . . V1-T5-42
Distribution Equipment—Substations . . . . . . . . . . V1-T5-43
Distribution Equipment—Panels. . . . . . . . . . . . . . . V1-T5-46
Distribution Equipment—Transformers . . . . . . . . . V1-T5-47
Firehouse
Product Description
The Firehouse is designed to
provide added fire safety to
RV parks and campgrounds.
The Firehouse provides a
convenient location and easy
access to fire extinguishers
and to an optional life ring
when installed around pools
and waterfront amenities.
In addition, the Firehouse
provides area lighting for easy
identification during an
emergency and for security
lighting around the unit. The
Firehouse can be equipped
with an alarm strobe light and
siren, which are automatically
activated when the fire
extinguisher cabinet door is
opened or the optional life
ring is removed.
Features
Photocell controlled
13 watt fluorescent light
Amber lens for bug
reduction
10 lb ABC Type fire
extinguisher
Stainless steel housing
with oven-baked enamel
finish with an engineered
resin base and top
Limited lifetime warranty
on the housing
Available Options
Alarm strobe light
and siren
Optional 24-inch white or
orange life ring for poolside
or dockside installations
20 lb ABC Type fire
extinguisher
Catalog Number Selection
Fire Extinguisher
E= Include 10 lb extinguisher
N= No extinguisher
X= Include 20 lb extinguisher
Type
F = Firehouse
Photocell
Y=Yes
N=No
Alarm/Strobe
A= Include alarm/strobe
N= No alarm/strobe
24-Inch Life Ring
R= Include life ring
N= No life ring
Lighting and Lens Color
R = LED Red
X= No lighting Red
F R Y A E R
V1-T5-40 Volume 1—Residential and Light Commercial CA08100002E—March 2019 www.eaton.com
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5.4
Power Pedestals
RV Park Hook-Ups
Accessories
See Page V1-T5-72.
Dimensions
Approximate Dimensions in Inches (mm)
Firehouse–SS
40.74
(1034.9)
9.88
(250.8)
11.54
(293.0)
Volume 1—Residential and Light Commercial CA08100002E—March 2019 www.eaton.com V1-T5-41
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5.4
Power Pedestals
RV Park Hook-Ups
Digital Electronic Kilowatthour Meters
Contents
Description Page
Power Pedestals. . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-28
Powerhouse Power Pedestal . . . . . . . . . . . . . . . . . V1-T5-30
Powerhouse—Stainless Steel (SS) Power Pedestal V1-T5-33
Newport Camp Mate Power Pedestal . . . . . . . . . . V1-T5-36
Firehouse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-39
Digital Electronic Kilowatthour Meters
Distribution Equipment—Ground Fault Monitor . . . V1-T5-42
Distribution Equipment—Substations . . . . . . . . . . V1-T5-43
Distribution Equipment—Panels. . . . . . . . . . . . . . . V1-T5-46
Distribution Equipment—Transformers . . . . . . . . . V1-T5-47
Digital Electronic Kilowatthour Meters
Product Description
Using the latest surface
mount technology, Eaton
manufactures a digital
electronic kilowatt hour
meter that exceeds the
+/– 2% accuracy required by
ANSI (American National
Standards Institute) C-12.1
and is approved by the state
of California at +/– 1% over
the full range of 0–100 A from
a 0.5 to 1 power factor and is
available for both single- and
three-phase applications.
The meter drives an electro-
mechanical counter that
requires a 12 V pulse each
tenth of a kilowatthour,
providing 10 pulses per
kilowatt used. The meter
output can be hard wired or
connected to a transmitter
in the pedestal for wireless
transmission to a receiver
displaying the output on a
PC for direct billing of up to
1,000 individual customers.
Features
Our meter is designed to
be user friendly in that all
connections from external
sources and the meter
output are through one
14-pin locking connector.
This feature eliminates many
common problems, such
as reverse line polarity and
improper coil polarity. Simple
LEDs, both red and green,
indicate line and load
condition and the pulsed
LED indicates the rate of
power consumption.
Wireless System
All of our meters are
“wireless capable” to allow
for wireless meter reading.
This technology enables the
marina or RV park to get
meter readings from one
central location rather than
visiting every site to read
the counters.
Meter Socket Capabilities
Meter sockets are available
on the Powerhouse and
Powerhouse–SS.
Standard:
Four jaw
Ring-type
100 A
Available Options
200 A (SS only)
Lockable hasp
Ringless (SS only)
Five jaw
Seven jaw (SS only)
Product Selection
One Element Meter
Two Element Meter
Three Element Meter
V1-T5-42 Volume 1—Residential and Light Commercial CA08100002E—March 2019 www.eaton.com
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5.4
Power Pedestals
RV Park Hook-Ups
Ground Fault Monitor
Contents
Description Page
Power Pedestals . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-28
Powerhouse Power Pedestal . . . . . . . . . . . . . . . . . V1-T5-30
Powerhouse—Stainless Steel (SS) Power Pedestal V1-T5-33
Newport Camp Mate Power Pedestal . . . . . . . . . . V1-T5-36
Firehouse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-39
Digital Electronic Kilowatthour Meters. . . . . . . . . . V1-T5-41
Distribution Equipment—Ground Fault Monitor
Distribution Equipment—Substations . . . . . . . . . . V1-T5-43
Distribution Equipment—Panels . . . . . . . . . . . . . . V1-T5-46
Distribution Equipment—Transformers . . . . . . . . . V1-T5-47
Distribution Equipment—Ground Fault Monitor
Product Description
New to our product offering
are ground fault monitoring
systems designed to detect
fault currents in the AC shore
power system that are too
low to trip a circuit breaker.
The Ground Fault Monitor
helps reduce the risk of injury
or property damage, which
may result from stray fault
currents. Our ground fault
monitoring system provides
information to the
maintenance staff on the
overall condition of the AC
electrical system. The ground
fault monitoring system
operates 24 hours a day and
can be monitored by non-
technical personnel.
Features
UL listed current
transformers
Adjustable trip level
10 mA to 10 A
Current transformers up to
8 1/4-inch diameter
Visual and/or audible alarm
Housing of fiberglass or
powder coated stainless
steel available
Power Guard
The ground fault monitor
detects ground fault
currents by means of current
transformers (CT), which are
placed around main or branch
circuits. If a ground fault
occurs, the CT will detect the
amount of fault current and
send a signal to the ground
fault monitoring device where
the amount of fault current
is displayed with the faulty
circuit identified. The
detected fault can either
activate an indicator alarm or
disconnect the faulted circuit.
Volume 1—Residential and Light Commercial CA08100002E—March 2019 www.eaton.com V1-T5-43
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5.4
Power Pedestals
RV Park Hook-Ups
Side-by-Side Substation
Substations
Contents
Description Page
Power Pedestals. . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-28
Powerhouse Power Pedestal . . . . . . . . . . . . . . . . . V1-T5-30
Powerhouse—Stainless Steel (SS) Power Pedestal V1-T5-33
Newport Camp Mate Power Pedestal . . . . . . . . . . V1-T5-36
Firehouse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-39
Digital Electronic Kilowatthour Meters . . . . . . . . . . V1-T5-41
Distribution Equipment—Ground Fault Monitor . . . V1-T5-42
Distribution Equipment—Substations
Features, Benefits and Functions . . . . . . . . . . . V1-T5-44
Available Options. . . . . . . . . . . . . . . . . . . . . . . . V1-T5-45
Standards and Certifications . . . . . . . . . . . . . . . V1-T5-45
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-45
Distribution Equipment—Panels. . . . . . . . . . . . . . . V1-T5-46
Distribution Equipment—Transformers . . . . . . . . . V1-T5-47
Distribution Equipment—Substations
Product Description
The introduction of
substations into the marina
and recreational vehicle
market allows Eaton to be
your complete marina and
RV park electrical products
supplier. We are able to
assist in the design and
layout of your marina or RV
park electrical system from
the primary service provider
to your power pedestal. Our
substations are designed
for any coastal or inland
environment and are
constructed of powder-
coated stainless steel
NEMA 3R housing cabinets.
All substation cabinets
come with our limited lifetime
warranty. All of our
substations use Eaton’s
panels and circuit breakers,
providing our customers the
utmost in circuit protection
and quality.
Application Description
The aluminum and Galvaneal
cabinets are recommended
for inland applications.
The substations can be
configured with 50 to
330 kVA single-phase or
three-phase copper wound
transformers and up to 20
single-phase or 12 three-
phase branch breakers. An
optional three-sided double-
wall cabinet is available that
provides air flow between the
panels. All substations come
standard with temperature-
controlled cooling fans.
Product Selection Guide
Panel and Transformer
Combinations
Panel Transformer
Single-Phase
200 A 50 kVA
300 A 75 kVA
400 A 100 kVA
600 A 150 kVA
700 A 167.5 kVA
800 A 200 kVA
1000 A 250 kVA
1200 A 330 kVA
Three-Phase
100 A 45 kVA
200 A 75 kVA
300 A 112.5 kVA
400 A 150 kVA
600 A 225 kVA
800 A 300 kVA
V1-T5-44 Volume 1—Residential and Light Commercial CA08100002E—March 2019 www.eaton.com
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5.4
Power Pedestals
RV Park Hook-Ups
Features, Benefits
and Functions
Limited lifetime warranty
on the housing
All stainless steel
hardware
Temperature controlled
cooling fans in the
transformer and circuit
breaker compartments
Lockable door
Ventilation
The substation ventilation
is designed to optimize air
circulation over and around
the transformers and through
the panel compartment so
that the substation operates
at lower temperatures.
Substations come equipped
with temperature-controlled
cooling fans for exhausting
hot air from the cabinet and
solar shield.
In addition, substations are
available with a double-
walled cabinet and solar
shield, which allow for
cooling of both the exterior
surface of the cabinet and
the internal components.
Substations
Stainless steel housing
with polyester
powder coating
Limited
lifetime
warranty
on the
housing
Stainless steel hardware with
locking doors
Temperature-controlled fans
for cooling
Custom made to your specifications:
Single-phase or three-phase copper
wound transformers
50 to 330 kVA
Up to 1200 A main circuit breaker with
20 single-phase or 12 three-phase
branch circuit breakers
Sun Heat
Transformers
Air
Cool Air
Double-Walled
Stainless
Double-Walled Construction
Volume 1—Residential and Light Commercial CA08100002E—March 2019 www.eaton.com V1-T5-45
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5.4
Power Pedestals
RV Park Hook-Ups
Available Options
Powder-coated cabinets
made of stainless steel
or fiberglass
Limited lifetime warranty
on housing. Transformer
and secondary distribution
panel in a single enclosure
have a one-year limited
warranty
Stainless steel housing
and hardware with
locking doors
Single-phase and three-
phase models
Overload capacity meets
ANSI L57.96–01.250
Optional double-walled
construction
Temperature-controlled
fans for cooling
Custom-made copper
wound single-phase or
three-phase transformers
from 50 to 330 kVA
Up to 1200 A main circuit
breaker with 15 single-
phase branch circuit
breakers or 10 three-phase
branch circuit breakers
Substations can be
equipped with photocells
to turn on and off lights
A 20 A GFI can be installed
in the cabinet, as well
as a ground fault
monitoring system
Standards and Certifications
cULus listed
Dimensions
Approximate Dimensions in
Inches (mm)
Substations
Standard Substation
Height 53.00 (1346.2)
Width 51.00 (1295.4)
Depth 33.00 (838.2)
Side-by-Side Substation
Height 53.00 (1346.2)
Width 66.00 (1676.4)
Depth 30.00 (762.0)
Double Panel Substation
Height 53.00 (1346.2)
Width 63.00 (1600.2)
Depth 33.00 (838.2)
V1-T5-46 Volume 1—Residential and Light Commercial CA08100002E—March 2019 www.eaton.com
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5.4
Power Pedestals
RV Park Hook-Ups
Panels
Contents
Description Page
Power Pedestals . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-28
Powerhouse Power Pedestal . . . . . . . . . . . . . . . . . V1-T5-30
Powerhouse—Stainless Steel (SS) Power Pedestal V1-T5-33
Newport Camp Mate Power Pedestal . . . . . . . . . . V1-T5-36
Firehouse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-39
Digital Electronic Kilowatthour Meters. . . . . . . . . . V1-T5-41
Distribution Equipment—Ground Fault Monitor. . . V1-T5-42
Distribution Equipment—Substations . . . . . . . . . . V1-T5-43
Distribution Equipment—Panels
Distribution Equipment—Transformers . . . . . . . . . V1-T5-47
Distribution Equipment—Panels
Product Description
We now can offer our
customers Eaton’s PRL-3A
and PRL-4 panels as stand-
alone units or in one of our
substations. All of our busses
are made of copper and are
load rated, breakers are bolt-
on type. Distribution panels
can be single-phase or three-
phase based on your system
requirements. Distribution
panels can also have a
main breaker or a main lug.
Branch circuit breakers
are provided based on
customer requirements.
Features
All internal wiring is
fine stranded 2000 V
insulated copper
Copper busbars
All exterior hardware is
stainless steel
Available Options
NEMA 3R or 4X
Powder-coated
stainless steel
Main breaker up to
1200 A
Branch breaker 20 to
1200 A
Main lug only
We also offer 480 V
models—single-phase
and three-phase
Single-Phase
Up to 1200 A main
circuit breakers
Up to 42 branch
circuit breakers
Three-Phase
Up to 1200 A main
circuit breakers
Up to 42 branch
circuit breakers
Standards and Certifications
UL listed
cULus listed
Volume 1—Residential and Light Commercial CA08100002E—March 2019 www.eaton.com V1-T5-47
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5.4
Power Pedestals
RV Park Hook-Ups
Transformers
Contents
Description Page
Power Pedestals. . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-28
Product Selection Guide . . . . . . . . . . . . . . . . . . V1-T5-29
Powerhouse Power Pedestal . . . . . . . . . . . . . . . . . V1-T5-30
Powerhouse—Stainless Steel (SS) Power Pedestal V1-T5-33
Newport Camp Mate Power Pedestal . . . . . . . . . . V1-T5-36
Firehouse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-39
Digital Electronic Kilowatthour Meters . . . . . . . . . . V1-T5-41
Distribution Equipment—Ground Fault Monitor . . . V1-T5-42
Distribution Equipment—Substations . . . . . . . . . . V1-T5-43
Distribution Equipment—Panels. . . . . . . . . . . . . . . V1-T5-46
Distribution Equipment—Transformers
Distribution Equipment—Transformers
Product Description
Because of the high humidity
and corrosive conditions of
coastal environments, our
transformers are wound with
Class H heavily insulated
copper bar and are double
dipped in tough insulating
varnish that protects the
copper, as well as reduces
the hum that is typical in
a transformer that is not
double dipped. For marine
applications, we provide
a third overcoat of high
temperature epoxy to protect
against the severe saltwater
environment. We can provide
this transformer in single-
phase, from 50 to 500 kVA,
and three-phase, from
45 to 300 kVA.
Features
Copper wound transformer
coils double dipped in high
temperature baking varnish
Copper terminations
Marine transformers with
epoxy overcoat
All copper-to-copper
connections
Available Options
Single-phase: 50–500 kVA
Three-phase: 45–300 kVA
Epoxy overcoat for non-
marine applications
Primary Voltages
480 wye three-phase
480 V three-phase delta
three-wire + ground
480 V single-phase
two-wire + ground
Secondary Voltages
127/220 V three-phase
wye four-wire
120/208 V three-phase
wye four-wire
120/240 V single-phase
three-wire
Marina Power Distribution
Transformer kVA Availabilities
Single-phase: 50, 75, 100,
150, 167.5, 200, 250, 330,
500 kVA
Three-phase: 45, 75, 112.5,
150, 225, 300 kVA
Standards and Certifications
cULus listed
V1-T5-48 Volume 1—Residential and Light Commercial CA08100002E—March 2019 www.eaton.com
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5.5
Power Pedestals
Marina Power and Lighting Equipment
High-Quality, Weatherproof Electrical Equipment
Marina Power and Lighting Equipment
Contents
Description Page
Power Pedestals
Product Selection Guide . . . . . . . . . . . . . . . . . . V1-T5-49
Lighthouse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-51
Lighthouse–SS . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-55
Admiral–SS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-59
Newport Harbor Mate . . . . . . . . . . . . . . . . . . . . . . V1-T5-62
Hatteras Light. . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-66
Firehouse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-70
Smart Start. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-76
Mariner. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-77
Digital Electronic Kilowatthour Meters. . . . . . . . . . V1-T5-41
Distribution Equipment—Ground Fault Monitor. . . V1-T5-42
Distribution Equipment—Mega Yacht Powerpoint. V1-T5-80
Distribution Equipment—Substations . . . . . . . . . . V1-T5-83
Distribution Equipment—Panels . . . . . . . . . . . . . . V1-T5-86
Distribution Equipment—Transformers . . . . . . . . . V1-T5-87
Learn
Online
Power Pedestals
Product Overview
Known as a leader in
electrical control, power
distribution, and industrial
automation products and
services, Eaton is a quality
driven company that
constantly looks for ways to
provide enhanced product
and service solutions for their
customers. Eaton will be able
to provide Marina developers
a complete electrical solution.
For more information on
the other products available
from Eaton, visit us online
at www.eaton.com or
www.marinapower.com.
What Eaton has to Offer
Eaton has more marina
power outlets in service
than all other suppliers
combined
We offer complementary
comprehensive in-house
electrical designs for
your complete marina
development using all high
quality Eaton products
We can provide your
marina development with
complete remote wireless
digital electronic meter
reading
Not only can Eaton provide
your marina with the
highest quality power
pedestals and marine
distribution equipment, we
can also supply your entire
electrical needs for your
surrounding development
and beyond from safety
switches to loadcenters
and much more
Volume 1—Residential and Light Commercial CA08100002E—March 2019 www.eaton.com V1-T5-49
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5.5
Power Pedestals
Marina Power and Lighting Equipment
Product Selection Guide
Power Pedestal Quick Guide
Lighthouse Lighthouse–SS Hatteras Light
Newport
Harbor Mate Admiral–SS Firehouse Mariner Lookout Power Point
Main housing Engineered resin Stainless steel Engineered resin Engineered resin Stainless steel Stainless steel Engineered resin Stainless steel Stainless steel
Top Engineered resin Engineered resin Engineered resin Engineered resin Stainless steel Engineered resin Engineered resin Stainless steel Stainless steel
Optional stand Stainless steel PVC
External hardware Stainless steel Stainless steel Stainless steel Stainless steel Stainless steel Stainless steel Stainless steel Stainless steel Stainless steel
Standard lightwattage(s) 13 W 13 W 13 W 7 W 13 W 13 W 5 W, 7 W & 13 W 13 W
LED lighting option Yes Yes Yes No Yes Yes No No Yes
Photocell Yes Yes Yes Yes Yes Yes No No Yes
Lockable doors Yes Yes Yes Yes Yes Yes
Hose hangers Yes Yes No No Yes No No No No
Electric meters Yes—up to 4 Yes—up to 4 Yes—up to 2 Yes—up to 2 Yes—up to 4 No No No Yes—up to 6
Remote meter reading Yes Yes Yes Yes Yes No No No Yes
Water Two 3/4” Two 3/4” Two 1/2” Two 3/4” Two 3/4” None None None One 3/4” or more
Water meters Yes Yes No Yes Yes No No No Yes
Telephone Yes Yes Yes Yes Yes No No No Yes
Cable TV Yes Yes Yes Yes Yes No No No Yes
Internet Yes Yes Yes Yes Yes No No No Yes
Fire extinguisher No No No No No Yes—up to 20 lbs No No No
Life ring No No No No No Yes—24” No No No
Alarm and strobe light No No No No No Yes No No No
20 A 110 V GFI Yes Yes Yes Yes Yes No No No Yes
30 A 125 V twist—lock Yes Yes Yes Yes Yes No No No Yes
50 A 125/250 V twist—lock Yes Yes Yes Yes Yes No No No Yes
100 A 120/240 V pin and sleeve Yes Yes No No Yes No No No Yes
100 A 120/208 V pin and sleeve Yes Yes No No Yes No No No Yes
100 A 277/480 V pin and sleeve Yes Yes No No Yes No No No Yes
100 A 480 V pin and sleeve Yes Yes No No Yes No No No Yes
200 A 480 V pin and sleeve No No No No Yes No No No Yes
Hardwire compatible No No No No No No No No Yes
TVSS compatible Yes Yes No No Yes No No No Yes
Card swipe compatible Yes Yes No Yes Yes No No No Yes
Security camera compatible No No No No No No No Yes No
Busbar rating Up to 500 A Up to 500 A Up to 140 A Up to 140 A Up to 500 A Up to 800 A
Maximum wire size—single feed 350 kcmil 350 kcmil #2/0 #2/0 350 kcmil (3) 500 kcmil
Maximum wire size—loop feed #4/0 #4/0 #1 #1 350 kcmil (3) 500 kcmil
Height 44” 40” 30” 36” 48” 43.5” 24” to 72” 72” to 96” 50”
Width 13.75” 9.875” 7.5” 10.5” 14” 9.875” 7” 9” 50”
Depth 13.75” 9.875” 7.5” 14.5” 14” 9.875” 7” 9” 36”
Warranty
Housing Limited lifetime Limited lifetime Limited lifetime Limited lifetime Limited lifetime Limited lifetime Limited lifetime Limited lifetime Limited lifetime
Receptacles and breakers 2 years 2 years 2 years 2 years 2 years 2 years
Lighting assembly 1 year 1 year 1 year 1 year 1 year 1 year 1 year 1 year
V1-T5-50 Volume 1—Residential and Light Commercial CA08100002E—March 2019 www.eaton.com
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5.5
Power Pedestals
Marina Power and Lighting Equipment
Receptacles Receptacle Configuration Availability
Note
1Configuration available with no additional GFI receptacles.
Side One Side Two
None None None None
30 A None None None
30 A 30 A None None
30 A None 30 A None
30 A 30 A 30 A 30 A
30 A 50 A None None
30 A None 50 A None
30 A 50 A 30 A 50 A
50 A None None None
50 A 50 A None None
50 A None 50 A None
50 A 50 A 50 A 50 A
100 A 120/240 V None None None
100 A 120/240 V None 50–50 A None
100 A 120/240 V None 100 A 120/240 V None
100 A 120/240 V 50–50 A 100 A 120/240 V 50–50 A
100 A 120/208 V None None None
100 A 120/208 V None 100 A 120/240 V None
100 A 120/240 V 100 A 120/240 V 100 A 120/240 V 100 A 120/240 V
100 A 120/208 V 100 A 120/208 V 100 A 120/208 V 100 A 120/208 V
100 A 120/240 V 100 A 120/240 V 100 A 120/208 V 100 A 120/208 V
Lighthouse Lighthouse–SS Admiral–SS Hatteras Light
Newport
Harbor Mate
Receptacle Available with GFI Receptacles
Yes Yes Yes Yes Yes
Yes Yes Yes Yes Yes
Yes Yes Yes No Yes
Yes Yes Yes Yes No
Yes Yes Yes No No
Yes Yes Yes No Yes
Yes Yes Yes Yes 1No
Yes Yes Yes No No
Yes Yes Yes Yes Yes
Yes Yes Yes No Yes
Yes Yes Yes No No
Yes Yes Yes No No
Yes Yes Yes No No
Yes Yes Yes No No
Yes Yes Yes No No
No No Yes No No
Yes Yes Yes No No
Yes Yes Yes No No
No No Yes No No
No No Yes No No
No No Yes No No
Volume 1—Residential and Light Commercial CA08100002E—March 2019 www.eaton.com V1-T5-51
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5.5
Power Pedestals
Marina Power and Lighting Equipment
Lighthouse
Contents
Description Page
Power Pedestals. . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-48
Lighthouse
Available Options. . . . . . . . . . . . . . . . . . . . . . . . V1-T5-52
Catalog Number Selection . . . . . . . . . . . . . . . . V1-T5-53
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-54
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-54
Lighthouse–SS . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-55
Admiral–SS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-59
Newport Harbor Mate . . . . . . . . . . . . . . . . . . . . . . V1-T5-62
Hatteras Light . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-66
Firehouse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-70
Smart Start . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-76
Mariner . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-77
Digital Electronic Kilowatthour Meters . . . . . . . . . . V1-T5-41
Distribution Equipment—Ground Fault Monitor . . . V1-T5-42
Distribution Equipment—Mega Yacht Powerpoint . V1-T5-80
Distribution Equipment—Substations . . . . . . . . . . V1-T5-83
Distribution Equipment—Panels. . . . . . . . . . . . . . . V1-T5-86
Distribution Equipment—Transformers . . . . . . . . . V1-T5-87
Lighthouse
Product Description
One of our most popular
units, the all-purpose
Lighthouse® pedestal has a
wide range of features. With
units in service around the
world, this stylish power
pedestal is recognized for its
practicality and exceptional
durability.
Engineered to withstand
the most severe weather
conditions, Lighthouse
power pedestals can be
found in marinas from
Alaska to the tropics.
Note: Custom paint color.
Note: Wireless remote reading
of electronic kilowatt meters.
Note: Clear lens.
Features, Benefits
and Functions
Photocell controlled
13 watt fluorescent light
(clear lens or amber lens
for bug reduction)
Lockable weatherproof
doors that protect breakers
and receptacles while in
use (a requirement of NFPA
303 and NEC Article 555)
Hose and cable brackets
Heavy resin housing with
a two-part polyurethane
coating for a UV-resistant,
long-lasting finish
Copper busbar with ratings
from 250 to 500 A
New “hingeless” base
providing easy access for
both installation and
maintenance
Backlit faceplate for easy
receptacle plug-in at night
V1-T5-52 Volume 1—Residential and Light Commercial CA08100002E—March 2019 www.eaton.com
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5.5
Power Pedestals
Marina Power and Lighting Equipment
Lighthouse
Copper Busbar with Ratings
from 250 to 500 A
New Hingeless Base
Cable and Internet
Connections
Optional Meter Socket
360° controlled 13 watt fluorescent light
with amber lens for bug reduction
Digital electronic metering for each side
Lockable weatherproof doors that protect
breakers and receptacles
Receptacle configuration available
30 A, 50 A, 30 A / 30 A, 30 A / 50 A,
50 A / 50 A, 100 A, Empty
Note: Custom configurations also available
Hose and cable brackets
1/4-inch Resin housing with a two-part
polyurethane coating for a UV resistant,
long-lasting finish
20 A / 125 V GFI receptacle
Phone and cable TV connections
High-speed Internet connections (RJ45) for
each side
Available Options
Digital electronic metering
(one, two or three element
meters available)
Built-in meter socket
20 A / 125 V GFI receptacle
(max. of two GFI
receptacles per pedestal)
Note: 20 A GFI receptacles are
not to be used for shore power.
High-speed Internet
connections
Wireless remote metering
for electric and water
Transient voltage surge
suppressor (TVSS) to
protect from voltage
surges, spikes or lightning
on the AC power line
(extends warranty on
internal parts to three
years)
Stainless steel door hinge
on receptacle main doors
Single or dual steel 1/4-turn
ball valves with 3/4-inches
Hose bibs and stainless
steel handles
Single or dual phone and/or
cable TV connections
Base cap
Base extension
LED lighting
Volume 1—Residential and Light Commercial CA08100002E—March 2019 www.eaton.com V1-T5-53
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5.5
Power Pedestals
Marina Power and Lighting Equipment
Catalog Number Selection
Receptacle: R1S1 = Receptacle 1, Side 1
R2S1 = Receptacle 2, Side 1
R1S2 = Receptacle 1, Side 2
R2S2 = Receptacle 2, Side 2
Notes
1Number represents the quantity of 1/4-turn ball valves with 3/4-inch hose bibs.
2Quantity of 20 A GFI duplex receptacles.
Extra Unmetered
GFI Receptacles 2
0=None
1=1
2=2
Water Option 1
0=0
1=1
2=2
3= Single water meter
4= Dual water meter
5= Single meter for
two valves
Sides and Receptacles
R1S1
R2S1
R3S1
R4S1
R1S2
R2S2
R3S2
R4S2
0
1
2
3
4
G
H
0
1
2
3
4
G
H
xx0
1
2
3
4
G
0
1
2
3
4
G
H
xx
x=None
0=None
1= 20 A GFI duplex
2= 30 A, 125 V
3= 50 A, 125 V
4= 50 A, 125/250 V
G= 30 A, 125 V GFI breaker
H= 50 A, 125/250 V GFI breaker
Type
L= Lighthouse
S=LHSS
Lighting and Lens Color
D= LED Amber
I= LED Clear
N= LED Special
B= LED Blue
F= No lighting Amber
L= No lighting Clear
Y= No lighting Special
P= No lighting Blue
L D U 2 3 x x 2 3 x x 2 0 R S
Metering Type
U= Unmetered
1= Digital electronic meters (side 1)
2= Digital electronic meters (side 2)
E= Digital electronic metering (entire pedestal)
B= Digital electronic metering (both sides)
R= Receptacles metered individually (one/rec.)
Phone Cable TV and Internet Options
Phone
Jack
Cable
TV Jack
Internet
Option
A
B
C
D
E
F
G
H
I
J
K
L
M
N
O
P
Q
R
S
T
U
V
W
X
Y
Z
0
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
1
1
1
1
1
1
1
1
1
2
2
2
2
2
2
2
2
2
0
0
0
0
0
0
0
0
0
0
0
0
1
1
1
2
2
2
0
0
0
1
1
1
2
2
2
2
0
0
1
1
1
2
2
0
0
1
2
0
1
2
0
1
2
0
1
2
0
1
2
0
1
2
2
1
2
0
1
2
0
1
0
Bus
S= Single-phase 3/8-inch copper bus bar
F= Three-phase 3/8-inch copper bus bar
M= Single-phase 300 kcmil mechanical lug bus
Z= Three-phase 300 kcmil mechanical lug bus
L= Single-phase 350 kcmil mechanical lug bus
P= Three-phase 350 kcmil mechanical lug bus
Q= Single-phase 3/8-16-inch copper bus bar
R= Three-phase 3/8-16-inch copper bus bar
T= Single-phase 300 kcmil mechanical lug Canadian bus
U= Single-phase 350 kcmil mechanical lug Canadian bus
V= Single-phase 350 kcmil mechanical lug Canadian bus
W= Three-phase 350 kcmil mechanical lug Canadian bus
N= Single-phase 1/4-inch copper bus bar
V1-T5-54 Volume 1—Residential and Light Commercial CA08100002E—March 2019 www.eaton.com
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5.5
Power Pedestals
Marina Power and Lighting Equipment
Accessories
See Page V1-T5-72.
Dimensions
Approximate Dimensions in Inches (mm)
Lighthouse
Side View
To p
Front View
Broken View
13.75
(249.3)
44.00
(1117.6)
Volume 1—Residential and Light Commercial CA08100002E—March 2019 www.eaton.com V1-T5-55
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5.5
Power Pedestals
Marina Power and Lighting Equipment
Lighthouse–SS
Contents
Description Page
Power Pedestals. . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-48
Lighthouse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-51
Lighthouse–SS
Available Options. . . . . . . . . . . . . . . . . . . . . . . . V1-T5-56
Catalog Number Selection . . . . . . . . . . . . . . . . V1-T5-57
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-58
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-58
Admiral–SS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-59
Newport Harbor Mate . . . . . . . . . . . . . . . . . . . . . . V1-T5-62
Hatteras Light . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-66
Firehouse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-70
Smart Start . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-76
Mariner . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-77
Digital Electronic Kilowatthour Meters . . . . . . . . . . V1-T5-41
Distribution Equipment—Ground Fault Monitor . . . V1-T5-42
Distribution Equipment—Mega Yacht Powerpoint . V1-T5-80
Distribution Equipment—Substations . . . . . . . . . . V1-T5-83
Distribution Equipment—Panels. . . . . . . . . . . . . . . V1-T5-86
Distribution Equipment—Transformers . . . . . . . . . V1-T5-87
Lighthouse–SS
Product Description
The Lighthouse–SS offers
the same standard features
and available options as the
standard Lighthouse. But,
like all of the stainless steel
products manufactured here,
the Lighthouse–SS is made
with high-quality 316L
stainless steel for superior
quality and performance.
Note: 20/125 A GFI receptacle.
Note: Wireless remote reading
of electronic kilowatt meters.
Note: Clear lens.
Note: Meter socket for each
side powered (to accept glass
style meter).
Note: Receptacle configurations
available:
30 A
30 A / 30 A
30 A / 50 A
50 A / 50 A
100 A (single-phase) 120/240 V
100 A (three-phase) 120/208 V
200 A (three-phase) 480 V
Features, Benefits
and Functions
Photocell controlled
13 watt fluorescent light
(clear lens or amber lens
for bug reduction)
Available with lockable
weatherproof doors
Hose and cable brackets
Long-lasting maintenance-
free 316L stainless steel
housing with limited
lifetime warranty
Copper busbar with ratings
from 250 to 500 A
Large removable
access panel for easy
maintenance and
installation
Backlit faceplate for easy
receptacle plug-in at night
V1-T5-56 Volume 1—Residential and Light Commercial CA08100002E—March 2019 www.eaton.com
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5.5
Power Pedestals
Marina Power and Lighting Equipment
Lighthouse–SS
Phone and Cable TV Connections
Copper Busbar with Ratings
from 250 to 500 A
New Door
Backlit Faceplate to Aid
in Hooking Up at Night
360° controlled 13 watt
fluorescent light with amber
lens for bug reduction
Digital electronic metering
for each s ide
Powder-coated stainless steel
weatherproof doors that protect
receptacles and breakers
Lockable doors
Long-lasting maintenance-free
powder-coated stainless steel
housing with limited lifetime
warranty
High-speed Internet connection
(RJ-45)
for each s ide
Large removable access panel
for easy maintenance and
installation
Hose and cable bracket
Available Options
Digital electronic metering
(one, two or three element
meters available)
20 A / 125 V GFI receptacle
(max. of two GFI
receptacles per pedestal)
Note: 20 A GFI receptacles are
not to be used for shore power.
High-speed Internet
connection
Wireless remote metering
available for water and
electricity
Transient voltage surge
suppressor (TVSS) to
protect from voltage
surges, spikes or lightning
on the AC power line
(extends warranty on
internal parts to three
years)
Single or dual phone and/or
cable TV connections
Single or dual 3/4-inch hose
bibs with stainless steel
Handles LED lighting
Volume 1—Residential and Light Commercial CA08100002E—March 2019 www.eaton.com V1-T5-57
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5.5
Power Pedestals
Marina Power and Lighting Equipment
Catalog Number Selection
Receptacle: R1S1 = Receptacle 1, Side 1
R2S1 = Receptacle 2, Side 1
R1S2 = Receptacle 1, Side 2
R2S2 = Receptacle 2, Side 2
Notes
1Number represents the quantity of 1/4-turn ball valves with 3/4-inch hose bibs.
2Quantity of 20 A GFI duplex receptacles.
Extra Unmetered
GFI Receptacles 2
0=None
1=1
2=2
Water Option 1
0=0
1=1
2=2
3= Single water meter
4= Dual water meter
5= Single meter for
two valves
Sides and Receptacles
R1S1
R2S1
R3S1
R4S1
R1S2
R2S2
R3S2
R4S2
0
1
2
3
4
5
6
7
8
G
H
0
1
2
3
4
5
6
7
8
G
H
0
1
2
3
4
5
6
7
8
G
H
0
1
2
3
4
5
6
7
8
G
H
0
1
2
3
4
5
6
7
8
G
H
0
1
2
3
4
5
6
7
8
G
H
0
1
2
3
4
5
6
7
8
G
H
0
1
2
3
4
5
6
7
8
G
H
0=None
1= 20 A GFI duplex
2= 30 A, 125 V
3= 50 A, 125 V
4= 50 A, 125/250 V
5= 100 A, 120/208 V
6= 100 A, 125/250 V
7= 100 A, 277/480 V
8= 100 A, 480 V
G= 30 A, 125 V GFI breaker
H= 50 A, 125/250 V GFI breaker
Type
L= Lighthouse
S=LHSS
Lighting and Lens Color
D= LED Amber
I= LED Clear
N= LED Special
B= LED Blue
F= No lighting Amber
L= No lighting Clear
Y= No lighting Special
P= No lighting Blue
SDU2323232320RS
Metering Type
U= Unmetered
1= Digital electronic meters (side 1)
2= Digital electronic meters (side 2)
E= Digital electronic metering (entire pedestal)
B= Digital electronic metering (both sides)
R= Receptacles metered individually (one/rec.)
M= One 100 A meter socket (ring-type)
N= One 100 A meter socket (ringless)
O= Two 100 A meter socket (ring-type)
P= Two 100 A meter socket (ringless)
Phone Cable TV and Internet Options
Phone
Jack
Cable
TV Jack
Internet
Option
A
B
C
D
E
F
G
H
I
J
K
L
M
N
O
P
Q
R
S
T
U
V
W
X
Y
Z
0
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
1
1
1
1
1
1
1
1
1
2
2
2
2
2
2
2
2
2
0
0
0
0
0
0
0
0
0
0
0
0
1
1
1
2
2
2
0
0
0
1
1
1
2
2
2
2
0
0
1
1
1
2
2
0
0
1
2
0
1
2
0
1
2
0
1
2
0
1
2
0
1
2
2
1
2
0
1
2
0
1
0
Bus
S= Single-phase 3/8-inch copper bus bar
F= Three-phase 3/8-inch copper bus bar
M= Single-phase 300 kcmil mechanical lug bus
Z= Three-phase 300 kcmil mechanical lug bus
L= Single-phase 350 kcmil mechanical lug bus
P= Three-phase 350 kcmil mechanical lug bus
N= Single-phase 1/4-inch copper bus bar
Q= Single-phase 3/8-16-inch copper bus bar
R= Three-phase 3/8-16-inch copper bus bar
T= Single-phase 300 kcmil mechanical lug Canadian bus
U= Single-phase 350 kcmil mechanical lug Canadian bus
V= Single-phase 350 kcmil mechanical lug Canadian bus
W= Three-phase 350 kcmil mechanical lug Canadian bus
X= Single-phase 500 A 3/8-inch copper bus bar
Y= Three-phase 500 A 3/8-inch copper bus bar
V1-T5-58 Volume 1—Residential and Light Commercial CA08100002E—March 2019 www.eaton.com
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5.5
Power Pedestals
Marina Power and Lighting Equipment
Accessories
See Page V1-T5-72.
Dimensions
Approximate Dimensions in Inches (mm)
Lighthouse–SS
9.88
(251.0)
40.00
(1016.0)
Volume 1—Residential and Light Commercial CA08100002E—March 2019 www.eaton.com V1-T5-59
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5.5
Power Pedestals
Marina Power and Lighting Equipment
Admiral–SS
Contents
Description Page
Power Pedestals. . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-48
Lighthouse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-51
Lighthouse–SS . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-55
Admiral–SS
Catalog Number Selection . . . . . . . . . . . . . . . . V1-T5-60
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-61
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-61
Newport Harbor Mate . . . . . . . . . . . . . . . . . . . . . . V1-T5-62
Hatteras Light . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-66
Firehouse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-70
Smart Start . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-76
Mariner . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-77
Digital Electronic Kilowatthour Meters . . . . . . . . . . V1-T5-41
Distribution Equipment—Ground Fault Monitor . . . V1-T5-42
Distribution Equipment—Mega Yacht Powerpoint . V1-T5-80
Distribution Equipment—Substations . . . . . . . . . . V1-T5-83
Distribution Equipment—Panels. . . . . . . . . . . . . . . V1-T5-86
Distribution Equipment—Transformers . . . . . . . . . V1-T5-87
Admiral–SS
Product Description
Truly the flagship of our
unitized pedestal line, the
Admiral–SS possesses
amperage capabilities up
to 500 A and voltages of
480/277 three-phase,
120/240 single-phase and
combinations of these
receptacles all in one unit
to serve nearly any size
Mega Yacht.
Features
Heavy 316L stainless
steel housing that is
powder coated with a
polyester resin
Photocell controlled
13 watt fluorescent light
with clear lens that
provides 360 degrees
of lighting
Available Options
Dual phone and/or cable TV
connections
Four 100 A receptacles
of any two voltage
combinations such as
277/480 three-phase,
120/208 three-phase or
120/240 single-phase
200 A / 480 V receptacles
when the 100 A 120/240 V
receptacles are used, two
50 A 120/240 V
receptacles can also be
provided for a total of
500 A
20 A / 125 V GFI receptacle
(max. of two GFI
receptacles per pedestal)
Note:
20 A GFI receptacles are
not to be used for shore power.
Single or dual Cat5
high-speed Internet
connections
Single or dual water
1/4-turn ball valves with
3/4-inch hose bibs and
stainless steel handles
Digital metering available
Wireless remote metering
available for water and
electricity
LED lighting
V1-T5-60 Volume 1—Residential and Light Commercial CA08100002E—March 2019 www.eaton.com
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5.5
Power Pedestals
Marina Power and Lighting Equipment
Catalog Number Selection
Receptacles: R1S1 = Receptacle 1, Side 1
R2S1 = Receptacle 2, Side 1
R3S1 = Receptacle 3, Side 1
R4S1 = Receptacle 3, Side 1
R1S2 = Receptacle 1, Side 2
R2S2 = Receptacle 2, Side 2
R3S2 = Receptacle 3, Side 2
R4S2 = Receptacle 3, Side 2
Notes
1Number represents the quantity of 1/4-turn ball valves with 3/4-inch hose bibs.
2Number represents the quantity of RJ-45 high-speed Internet jacks.
Internet option also available. Contact factory for details.
Extra Unmetered GFI
Receptacles
0=None
1=1
2=2
Water Option 1
0=0
1=1
2=2
3= Single water meter
4= Dual water meter
5= Single meter, 2 V
Sides and Receptacles
R1S1
R2S1
R3S1
R4S1
R1S2
R2S2
R3S2
R4S2
0
1
2
3
4
5
6
7
8
9
G
H
0
1
2
3
4
5
6
7
8
9
G
H
0
1
2
3
4
5
6
7
8
9
G
H
0
1
2
3
4
5
6
7
8
9
G
H
0
1
2
3
4
5
6
7
8
9
G
H
0
1
2
3
4
5
6
7
8
9
G
H
0
1
2
3
4
5
6
7
8
9
G
H
0
1
2
3
4
5
6
7
8
9
G
H
0=None
1= 20 A GFI duplex
2= 30 A, 125 V
3= 50 A, 125 V
4= 50 A, 125/250 V
5= 100 A, 208 V
6= 100 A, 250 V
7= 100 A, 277/480 V
8= 100 A, 480 V
9= 200 A, 480 V
G= 30 A, 125 V GFI breaker
H= 50 A, 125/250 V GFI breaker
Type
A= Admiral–SS
Lighting and Lens Color
D= LED Amber
I= LED Clear
N= LED Special
B= LED Blue
F= No lighting Amber
L= No lighting Clear
Y= No lighting Special
P= No lighting Blue
ADU2323232312RS
Metering Type
U= Unmetered
1= Digital electronic meters (side 1)
2= Digital electronic meters (side 2)
E= Digital electronic metering (entire pedestal)
B= Digital electronic metering (both sides)
R= Receptacles metered individually (one/rec.)
M= One 100 A meter socket (ring-type)
N= One 100 A meter socket (ringless)
O= Two 100 A meter socket (ring-type)
P= Two 100 A meter socket (ringless)
Phone Cable TV and Internet Options
Phone
Jack
Cable
TV Jack
Internet
Option
A
B
C
D
E
F
G
H
I
J
K
L
M
N
O
P
Q
R
S
T
U
V
W
X
Y
Z
0
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
1
1
1
1
1
1
1
1
1
2
2
2
2
2
2
2
2
2
0
0
0
0
0
0
0
0
0
0
0
0
1
1
1
2
2
2
0
0
0
1
1
1
2
2
2
2
0
0
1
1
1
2
2
0
0
1
2
0
1
2
0
1
2
0
1
2
0
1
2
0
1
2
2
1
2
0
1
2
0
1
0
Bus
S= Single-phase 3/8-inch copper bus bar
F= Three-phase 3/8-inch copper bus bar
M= Single-phase 300 kcmil mechanical lug bus
Z= Three-phase 300 kcmil mechanical lug bus
L= Single-phase 350 kcmil mechanical lug bus
P= Three-phase 350 kcmil mechanical lug bus
N= Single-phase 1/4-inch copper bus bar
Q= Single-phase 3/8-16-inch copper bus bar
R= Three-phase 3/8-16-inch copper bus bar
T= Single-phase 300 kcmil mechanical lug Canadian bus
U= Single-phase 350 kcmil mechanical lug Canadian bus
V= Single-phase 350 kcmil mechanical lug Canadian bus
W= Three-phase 350 kcmil mechanical lug Canadian bus
X= Single-phase 500 A 3/8-inch copper bus bar
Y= Three-phase 500 A 3/8-inch copper bus bar
Volume 1—Residential and Light Commercial CA08100002E—March 2019 www.eaton.com V1-T5-61
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5.5
Power Pedestals
Marina Power and Lighting Equipment
Accessories
See Page V1-T5-72.
Dimensions
Approximate Dimensions in Inches (mm)
AdmiralSS
Base Footprint
12.50 (317.5)
14.00 (355.6)
Ø 0.62
(Ø 15.9)
10.00
(254.0)
14.00
(355.6)
0.75
(19.1)
50.54
(1283.8)
Front Side One Back Side Two
2.00
(50.8)
Water
Access
240V
Electrical
Access
280V
Electrical
Access
CATV/INT.
Access
CATV/INT.
Access
V1-T5-62 Volume 1—Residential and Light Commercial CA08100002E—March 2019 www.eaton.com
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5.5
Power Pedestals
Marina Power and Lighting Equipment
Newport Harbor Mate
Contents
Description Page
Power Pedestals . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-48
Lighthouse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-51
Lighthouse–SS . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-55
Admiral–SS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-59
Newport Harbor Mate
Available Options . . . . . . . . . . . . . . . . . . . . . . . V1-T5-63
Catalog Number Selection . . . . . . . . . . . . . . . . V1-T5-64
Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-65
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-65
Hatteras Light. . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-66
Firehouse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-70
Smart Start. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-76
Mariner. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-77
Digital Electronic Kilowatthour Meters. . . . . . . . . . V1-T5-41
Distribution Equipment—Ground Fault Monitor. . . V1-T5-42
Distribution Equipment—Mega Yacht Powerpoint. V1-T5-80
Distribution Equipment—Substations . . . . . . . . . . V1-T5-83
Distribution Equipment—Panels . . . . . . . . . . . . . . V1-T5-86
Distribution Equipment—Transformers . . . . . . . . . V1-T5-87
Newport Harbor Mate
Product Description
Five years of development
and 30 prototype models
have yielded this unit the
most innovative mini-power
center available. Host to a
variety of electrical services,
contained in a compact yet
strong housing, the Newport
Harbor Mate is packed with
features.
Features, Benefits
and Functions
Tough and durable resin
housing with UV inhibitor
for lasting finish
Photocell controlled 7 and
9 watt fluorescent light
(clear lens or amber lens
for bug reduction)
Designed to mount
on a dock box, piling or
stainless steel stand
Copper busbar with a
maximum rating of 140 A
Volume 1—Residential and Light Commercial CA08100002E—March 2019 www.eaton.com V1-T5-63
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5.5
Power Pedestals
Marina Power and Lighting Equipment
Newport Harbor Mate (Shown with Optional Stand)
Mounting Option Backlit Faceplate
Available with single, dual or
combo of 30 or 50 A receptacles
20 A / 125 V GFI receptacle
Phone, cable TV, high-speed
Internet connections
Digital electronic meter
Tough and durable resin housing
with UV inhibitor for lasting finish
Lockable weatherproof door that
protects receptacles and breakers
Photocell controlled 7 watt
fluorescent light with amber
lens for bug reduction
Stainless steel stand
Single or dual 1/2-turn brass ball
valve with 3/4-inch hose bibs
Designed to mount on a dock
box, piling, wall or optional
stand (shown in photo)
Available Options
Available with single, dual
or combination of 30 A or
50 A receptacles
20 A / 125 V GFI receptacle
(max. of two GFI
receptacles per pedestal)
Note: 20 A GFI receptacles are
not to be used for shore power.
Single or dual phone, cable
TV, high-speed Internet
connections
Electronic metering
(one or two element
meters available)
316L stainless steel stand
LED lighting
V1-T5-64 Volume 1—Residential and Light Commercial CA08100002E—March 2019 www.eaton.com
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5.5
Power Pedestals
Marina Power and Lighting Equipment
Catalog Number Selection
Receptacles: R1 = Receptacle 1
R2 = Receptacle 2
Notes
120 A GFIs not metered.
2Number represents the quantity of 1/4-turn ball valves with 3/4-inch hose bibs (with stand only).
Water
Option 2
0=0
1=1
2=2
Phone Cable TV and Internet Options
Phone
Jack
Cable
TV Jack
Internet
Option
A
B
C
D
E
F
G
H
I
S
T
U
V
W
X
Y
Z
0
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
1
1
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
1
1
1
2
2
2
2
0
0
1
1
1
2
2
0
0
1
2
0
1
2
0
1
2
2
1
2
0
1
2
0
1
0
Stand
0=0
S=Stand
Bus
S= Single-phase 3/8-inch copper bus bar
F= Three-phase 3/8-inch copper bus bar
M= Single-phase 300 kcmil mechanical lug bus
Z= Three-phase 300 kcmil mechanical lug bus
L= Single-phase 350 kcmil mechanical lug bus
P= Three-phase 350 kcmil mechanical lug bus
N= Single-phase 1/4-inch aluminum Canadian bus
O= Single-phase 1/4-inch split bus bar
Q= Single-phase 3/8-16-inch copper bus bar
R= Three-phase 3/8-16-inch copper bus bar
T= Single-phase 300 kcmil mechanical lug Canadian bus
U= Three-phase 300 kcmil mechanical lug Canadian bus
V= Single-phase 350 kcmil mechanical lug Canadian bus
W= Three-phase 350 kcmil mechanical lug Canadian bus
H= Single-phase 1/4-20 stud copper bus bar
I= Three-phase 1/4-20 stud copper bus bar
K= Single-phase 2/0 mechanical lug bus
J= Three-phase 2/0 mechanical lug bus
A= Canadian single-phase 1/4-20 stud copper bus bar
B= Canadian three-phase 1/4-20 stud copper bus bar
C= Canadian single-phase 2/0 mechanical lug
D= Canadian three-phase 2/0 mechanical lug
Sides and Receptacles
R1S1 R2S1 R3S1
0
1
2
3
4
G
H
0
1
2
3
4
G
H
0
1
0=None
1= 20 A GFI duplex
2= 30 A, 125 V
3= 50 A, 125 V
4= 50 A, 125/250 V
G= 30 A, 125 V GFI breaker
H= 50 A, 125/250 V GFI breaker
Type
N= NP Harbor Mate
C= NP Camp Mate
Lighting and Lens Color
D= LED Amber
I= LED Clear
N= LED Special
B= LED Blue
F= No lighting Amber
L= No lighting Clear
Y= No lighting Special
P= No lighting Blue
Metering Type 1
U= Unmetered
E= Digital electronic meters
R= Receptacles metered
individually
N D U 2 3 1 S 0 A S
Volume 1—Residential and Light Commercial CA08100002E—March 2019 www.eaton.com V1-T5-65
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5.5
Power Pedestals
Marina Power and Lighting Equipment
Accessories
See Page V1-T5-72.
Dimensions
Approximate Dimensions in Inches (mm)
Newport Harbor Mate
9.18 (233.0)
0.12
(3.2)
10.38
(263.7)
Newport Redesign Newport Redesign With Meters
10.52 (267.2)
9.59 (243.6) 10.38 (263.7)
14.53
(369.0)
13.63
(346.2)
7.44
(189.1)
6.70
(170.2)
3.40
(86.4)
1.68
(42.7)
2.37
(60.3)
4.02
(102.2)
1.54
(39.1)
6.70
(170.2)
3.40
(86.4)
1.68
(42.7)
2.37
(60.3)
4.02
(102.2)
1.54
(39.1)
9.18 (233.0)
0.12
(3.2)
10.38
(263.7)
10.52 (267.2) 7.44
(189.1)
14.53
(369.0)
15.28
(388.0)
10.38 (263.7)
12.88
(327.2)
V1-T5-66 Volume 1—Residential and Light Commercial CA08100002E—March 2019 www.eaton.com
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5.5
Power Pedestals
Marina Power and Lighting Equipment
Hatteras Light
Contents
Description Page
Power Pedestals . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-48
Lighthouse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-51
Lighthouse–SS . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-55
Admiral–SS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-59
Newport Harbor Mate . . . . . . . . . . . . . . . . . . . . . . V1-T5-62
Hatteras Light
Available Options . . . . . . . . . . . . . . . . . . . . . . . V1-T5-67
Catalog Number Selection . . . . . . . . . . . . . . . . V1-T5-68
Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-69
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-69
Firehouse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-70
Smart Start. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-76
Mariner. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-77
Digital Electronic Kilowatthour Meters. . . . . . . . . . V1-T5-41
Distribution Equipment—Ground Fault Monitor. . . V1-T5-42
Distribution Equipment—Mega Yacht Powerpoint. V1-T5-80
Distribution Equipment—Substations . . . . . . . . . . V1-T5-83
Distribution Equipment—Panels . . . . . . . . . . . . . . V1-T5-86
Distribution Equipment—Transformers . . . . . . . . . V1-T5-87
Hatteras Light
Product Description
The Hatteras® Light is an
elegant and low cost
alternative to the Lighthouse.
It uses the same 360 degree
light assembly as the
Lighthouse, yet is only
30 inches tall. Thousands
of these attractive pedestals
are found not only in marinas,
but also around pools, deck
areas, boardwalks and
landscape areas. The housing
will never rust or corrode and
comes with a limited lifetime
warranty. This unit is popular
for smaller slips at marinas
with the Lighthouse and for
private docks.
Note: Wireless remote reading
of electronic kilowatt meters.
Note: Clear lens.
Note: Custom paint color.
Features, Benefits
and Functions
Photocell controlled
13 watt fluorescent light
(clear lens or amber lens
for bug reduction)
Circuit breakers
Heavy resin housing with
a two-part polyurethane
coating for a UV resistant,
long-lasting finish
Copper busbar with a
maximum rating of 140 A
Volume 1—Residential and Light Commercial CA08100002E—March 2019 www.eaton.com V1-T5-67
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5.5
Power Pedestals
Marina Power and Lighting Equipment
Hatteras Light
Copper Busbar with Ratings
up to 140 A
Faceplate
20 A / 125 A GFI Receptacle
360° controlled 13 watt
fluorescent light with amber
lens for bug reduction
Receptacle config urations
available:
Side 1: 30 A, 50 A
Side 2: 30 A, N/A
Note: Custom configurations
also available
Digital electronic metering
Circuit breakers
Phone, cable TV,
high-speed Internet
connections
1/4-inch resin housing with a
two-part polyurethane coating
for a UV resistant, long-lasting
finish
1/2-turn brass ball valve and
3/4-inch hose bib
Available Options
20 A / 125 V GFI receptacle
(max. of two GFI
receptacles per pedestal)
Note: 20 A GFI receptacles are
not to be used for shore power.
Digital electronic metering
(one or two element meter
available)
Single or dual phone, cable
TV, high-speed Internet
connections
Single or dual 1/2-inch or
3/4-inch silcock with
stainless steel handles
LED lighting
V1-T5-68 Volume 1—Residential and Light Commercial CA08100002E—March 2019 www.eaton.com
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5.5
Power Pedestals
Marina Power and Lighting Equipment
Catalog Number Selection
Receptacles: R1 = Receptacle 1
R2 = Receptacle 2
Notes
120 A GFIs not metered.
2Number represents the quantity of 1/4-turn ball valves with 3/4-inch hose bibs.
3Wire size #2/0 kcmil or less.
Sides and Receptacles
R1S1 R2S1 R1S2
0
1
2
3
4
G
H
0
1
0
1
2
3
4
G
H
x= None
0= None
1= 20 A GFI duplex
2= 30 A, 125 V
3= 50 A, 125 V
4= 50 A, 125/250 V
G= 30 A, 125 V GFI breaker
H= 50 A, 125/250 V GFI breaker
Type
H= Hatteras Light
Hard Wired Breakers
0= None
1=1
2=2
Lighting and Lens Color
D= LED Amber
I= LED Clear
N= LED Special
B= LED Blue
F= No lighting Amber
L= No lighting Clear
Y= No lighting Special
P= No lighting Blue
Water Option 2
0=0
1=1
2=2
Metering Type 1
U= Unmetered
E= Digital electronic meters
R= Receptacles metered individually
H D U 2 0 4 2 0 0 S
Bus
H= Single-phase 1/4-20 stud copper bus bar
I= Three-phase 1/4-20 stud copper bus bar
K= Single-phase 2/0 mechanical lug bus
J= Three-phase 2/0 mechanical lug bus
A= Canadian single-phase 1/4-20 stud copper bus bar
B= Canadian three-phase 1/4-20 stud copper bus bar
C= Canadian single-phase 2/0 mechanical lug
D= Canadian three-phase 2/0 mechanical lug
Phone Cable TV and Internet Options
Phone
Jack
Cable
TV Jack
Internet
Option
A
B
C
D
E
F
G
H
I
J
K
L
M
N
O
P
Q
R
S
T
U
V
W
X
Y
Z
0
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
1
1
1
1
1
1
1
1
1
2
2
2
2
2
2
2
2
2
0
0
0
0
0
0
0
0
0
0
0
0
1
1
1
2
2
2
0
0
0
1
1
1
2
2
2
2
0
0
1
1
1
2
2
0
0
1
2
0
1
2
0
1
2
0
1
2
0
1
2
0
1
2
2
1
2
0
1
2
0
1
0
Volume 1—Residential and Light Commercial CA08100002E—March 2019 www.eaton.com V1-T5-69
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5.5
Power Pedestals
Marina Power and Lighting Equipment
Accessories
See Page V1-T5-72.
Dimensions
Approximate Dimensions in Inches (mm)
Hatteras
Side View Front View
Busbar Access Top Removed
Inside Top
7.90 (200.7) 7.90 (200.7)
30.98
(786.9)
13.39
(340.2)
V1-T5-70 Volume 1—Residential and Light Commercial CA08100002E—March 2019 www.eaton.com
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5.5
Power Pedestals
Marina Power and Lighting Equipment
Firehouse
Contents
Description Page
Power Pedestals . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-48
Lighthouse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-51
Lighthouse–SS . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-55
Admiral–SS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-59
Newport Harbor Mate . . . . . . . . . . . . . . . . . . . . . . V1-T5-62
Hatteras Light. . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-66
Firehouse
Available Options . . . . . . . . . . . . . . . . . . . . . . . V1-T5-71
Catalog Number Selection . . . . . . . . . . . . . . . . V1-T5-71
Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-72
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-40
Smart Start. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-76
Mariner. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-77
Digital Electronic Kilowatthour Meters. . . . . . . . . . V1-T5-41
Distribution Equipment—Ground Fault Monitor. . . V1-T5-42
Distribution Equipment—Mega Yacht Powerpoint. V1-T5-80
Distribution Equipment—Substations . . . . . . . . . . V1-T5-83
Distribution Equipment—Panels . . . . . . . . . . . . . . V1-T5-86
Distribution Equipment—Transformers . . . . . . . . . V1-T5-87
Firehouse
Product Description
Created as a complete
solution for fire and rescue
needs, this pedestal features
fire extinguisher storage and
a mounted alarm strobe light
and siren, as well as an
optional life ring. This unit
is well equipped for any
marina emergency. The alarm
strobe light and siren can be
automatically activated when
the door is open or optional
life ring is removed.
Features, Benefits
and Functions
Alarm strobe light and
siren: automatically
activated when door is
open or optional life ring
is removed
Photocell controlled
13 watt fluorescent light
(clear lens or amber lens
for bug reduction)
10 lb ABC Type fire
extinguisher
316L stainless steel
polyester powder-coated
housing
Polycarbonate top
assembly
Firehouse
High-visibility alarm
strobe light and warning
siren
Photocell controlled
energy efficient 13 watt
fluorescent light with
amber lens for bug
reduction
Stainless steel housing with
oven-baked enamel finish
with a polycarbonate base
and top
Remote control unit can
automatically call select
services via a four
channel transmitter:
Medical emergency
Fire emergency
Police emergency
Optional general
emergency
Volume 1—Residential and Light Commercial CA08100002E—March 2019 www.eaton.com V1-T5-71
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5.5
Power Pedestals
Marina Power and Lighting Equipment
Available Options
24-inch life ring
20 lb ABC Type fire
extinguisher available
Catalog Number Selection
Fire Extinguisher
E= Include 10 lb extinguisher
N= No extinguisher
X= Include 20 lb extinguisher
Type
F = Firehouse
Photocell
Y=Yes
N=No
Alarm/Strobe
A= Include alarm/strobe
N= No alarm/strobe
24-Inch Life Ring
R= Include life ring
N= No life ring
Lighting and Lens Color
R = LED Red
X= No lighting Red
F R Y A E R
V1-T5-72 Volume 1—Residential and Light Commercial CA08100002E—March 2019 www.eaton.com
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5.5
Power Pedestals
Marina Power and Lighting Equipment
Accessories
Accessories for Custom Design Marina Products, Resin and Stainless Steel Pedestals and Power Products
Replacement Parts Catalog Numbers Replacement Parts Catalog Numbers, continued
Description
Catalog
Number
Receptacles
20 A GFCI duplex MPL3038
30 A 125 V twistlock MPL3039
50 A 125 V twistlock MPL3040
50 A 125/250 V twistlock MPL3045
100 A 120/240 V pin and sleeve MPL4100R12W
100 A 120/208 pin and sleeve MPL5100R9W
100 A 480 V four-wire pin and sleeve MPL4100R7W
100 A 480 V five-wire pin and sleeve MPL5100R7W
200 A 277/480 V pin and sleeve (Russellstoll®)MPL4200R7W
30 A 125 V RV RV3042
50 A 125/250 V RV RV3043
Circuit Breakers
20 A 125 V single-pole QCF1020
20 A 125 V single-pole GFCI QCGF1020
30 A 125 V single-pole QCF1030
30 A 125 V single-pole GFCI QCGF1030
50 A 125 V single-pole QCF1050
20 A 125/250 V two-pole QCF2020
20 A 125/250 V two-pole GFCI QCGF2020
30 A 125/250 V two-pole QCF2030
30 A 125/250 V two-pole GFCI QCGF2030
50 A 125/250 V two-pole QCF2050
50 A 125/250 V two-pole GFCI QCGF2050
60 A 125/250 V two-pole QCF2060
100 A 125/250 V two-pole GHC2100D
100 A 120/208 V three-pole GHC3100D
200 A 277/480 V three-pole JT2200FA
Fluorescent Light Assembly
13 watt 120 V 60 Hz ballast MPL2400
7 watt 120 V 60 Hz ballast MPL2401
13 watt socket MPL3079
7 watt socket MPL3077
13 watt fluorescent bulb MPL3018
7 watt fluorescent bulb MPL3019
Photocell MPL3044
Photocell nuts MPL3034
Lighthouse in-line fuse MPL3026
Lighthouse in-line fuse holder MPL3027
Lighthouse, Lighthouse–SS, Powerhouse,
Powerhouse–SS, Hatteras, Park Light
Top with complete light and lens assembly MPL6003A
Top with complete light and lens assembly—fused MPL6003FA
Top only MPL6003
Amber lens MPL6005
Clear lens MPL6008
Description
Catalog
Number
Lighthouse, Lighthouse–SS, Powerhouse,
Powerhouse–SS, Hatteras, Park Light, continued
20 A GFCI receptacle external cover set MPL1101
30 A receptacle external cover set MPL1102
50 A receptacle external cover set MPL1105
Single-pole external breaker cover set MPL11061
Two-pole external breaker cover set MPL11062
Three-pole external breaker cover set MPL11063
Lighthouse, Lighthouse–SS, Powerhouse,
Powerhouse–SS
Lighthouse/Powerhouse pedestal main housing MPL6006
Lighthouse–SS/Powerhouse–SS pedestal main housing MPL6006S
Lighthouse/Powerhouse main door MPL6007
Lighthouse–SS/Powerhouse–SS main door MPL6007S
Lighthouse/Powerhouse spring closure MPL1099
Lighthouse Powerhouse top isolation plate MPL6012
Lighthouse/Lighthouse–SS breaker plate MPL1141
Powerhouse/Powerhouse–SS breaker plate RV1112
Lighthouse/Lighthouse–SS/Powerhouse/
Powerhouse–SS Hose and cable brackets
MPL1087
Lighthouse/Powerhouse stainless steel hinge MPL1088
Lighthouse/Powerhouse complete pedestal
base with busbar assembly
MPL6004A
Lighthouse/Powerhouse complete pedestal base with three-phase
busbar assembly
MPL6004FA
Lighthouse/Powerhouse pedestal base without busbars MPL6004
Lighthouse/Powerhouse aluminum blank access panel MPL5500
Lighthouse/Lighthouse–SS/Powerhouse/
Powerhouse–SS complete busbar assembly
MPL1140A
Lighthouse/Lighthouse–SS/Powerhouse/Powerhouse–SS complete
three-phase busbar assembly
MPL1140FA
Copper busbar with nuts and washers MPL3471
20 A GFCI—00 amber resin faceplate MPL1120
30 A—20 GFCI amber resin faceplate MPL1121
30–50 A amber resin faceplate MPL1122
30–30 A amber resin faceplate MPL1127
30–00 A amber resin faceplate MPL1129
50–50 A amber resin faceplate MPL1123
50 A—20 GFCI amber resin faceplate MPL1124
20 GFCI—20 GFCI amber resin faceplate MPL1125
00–00 amber resin faceplate MPL1126
50 A—00 amber resin faceplate MPL1128
100 A faceplate MPL1142
20 A GFCI—00 amber resin faceplate assembly with breakers MPL1120A
30 A—20 GFCI amber resin faceplate assembly with breakers MPL1121A
30–50 A amber resin faceplate assembly with breakers MPL1122A
Volume 1—Residential and Light Commercial CA08100002E—March 2019 www.eaton.com V1-T5-73
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5.5
Power Pedestals
Marina Power and Lighting Equipment
Replacement Parts Catalog Numbers, continued Replacement Parts Catalog Numbers, continued
Notes
1Lighthouse, Lighthouse–SS, Powerhouse, Powerhouse–SS.
2Hatteras Light, Park Light, Newport Camp Mate, Newport Harbor Mate.
3Please contact factory to determine configurations for replacement housing.
Description
Catalog
Number
Lighthouse, Lighthouse–SS, Powerhouse,
Powerhouse–SS, continued
30–30 A amber resin faceplate assembly with breakers MPL1127A
50–50 A amber resin faceplate assembly with breakers MPL1123A
50 A—20 GFCI amber resin faceplate assembly with breakers MPL1124A
20 GFCI—20 GFCI amber resin faceplate assembly with breakers MPL1125A
50 A—00 amber resin faceplate assembly with breakers MPL1128A
30–00 A faceplate assembly with breakers MPL1129A
100 A faceplate assembly with breakers MPL1142A
Powerhouse 30–50 receptacle plate RV1143
Powerhouse (30 A—00) receptacle plate RV11433
Powerhouse (50 A—00) receptacle plate RV11435
Powerhouse breaker plate RV1112
Phone, Cable, Internet Assemblies
Lighthouse/Powerhouse complete phone and cable assembly MPL1114/RV1114
Lighthouse–SS/Powerhouse–SS/Hatteras Light/Park Light complete
phone and cable assembly
MPL1119/RV1119
Hatteras Light/Park Light complete phone and cable assembly MPL1119
Newport Harbor Mate/Camp Mate phone and cable insert assembly MPL1115/RV1115
Lighthouse/Powerhouse access plates with dual Internet jacks MPL5501
Coax cable TV FCF female adpt. with lugnut and washer MPL1086
RJ45 CAT5e high-speed internet jack MPL3059
Marine phone receptacle MPL3037
RJ12 CAT3 phone jack RV3060
Water Assemblies
Lighthouse/Powerhouse complete water manifold assembly
(dual 3/4-inch hose bibs with 1/4-turn ball valves)
MPL11A
Newport Harbor Mate/Newport Camp Mate water manifold
assembly (dual 3/4-inch hose bibs with 1/4-turn ball valves)
MPL11C
3/4-inch hose adapter MPL7030
Lighthouse/Powerhouse water mounting plate
with mounting brackets
MPL1132
Hatteras Light/Park Light aluminum water mounting plate MPL6584
1/2-inch brass silcock (hose bib) MPL7014
3/4-inch stainless steel silcock (hose bib) MPL5271
3/4-inch brass ball valve MPL7021
Watts 3/4-inch backflow preventer MPL7015
Description
Catalog
Number
Digital Electronic Meters
Single element, 14-pin quick disconnect (no CTs) MPL17A1
Single element, 14-pin quick disconnect (with CTs) MPL17A2 1
Single element, 14-pin quick disconnect (with CTs) MPL17A2 2
Dual element, 14-pin quick disconnect (no CTs) MPL17B1
Dual element, 14-pin quick disconnect (with CTs) MPL17B2 1
Dual element, 14-pin quick disconnect (with CTs) MPL17B2 2
Three element, 14-pin quick disconnect (no CTs) MPL17C1
Three element, 14-pin quick disconnect (with CTs) MPL17C2 1
Three element, 14-pin quick disconnect (with CTs) MPL17C2 2
Single element coil transformers (CTs) MPL30321 1
Single element coil transformers (CTs) MPL30321 2
Dual element coil transformers (CTs) MPL30322 1
Dual element coil transformers (CTs) MPL30322 2
Three element coil transformers (CTs) MPL30323 1
Three element coil transformers (CTs) MPL30323 2
Counter (large—old style) MPL3022
Counter (small—new style) MPL3021
Hatteras Light (Marina) and Park Light (RV) 3
Pedestal main housing MPL6002
Copper busbar with nuts and washers MPL3468
Complete busbar assembly MPL1108A
Complete three-phase busbar assembly MPL1108FA
20 A GFCI external cover door MPL1101
30 A external cover door MPL1102
50 A external cover door MPL1105
Light fuse MPL3026
Fuse holder MPL3027
Mounting feet (set of four) MPL7004
V1-T5-74 Volume 1—Residential and Light Commercial CA08100002E—March 2019 www.eaton.com
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5.5
Power Pedestals
Marina Power and Lighting Equipment
Replacement Parts Catalog Numbers, continued
Note
1For custom faceplates to include phone/cable or other accessories,
please contact Eaton’s Marina Power & Lighting facility at 1-800-723-8009.
Description
Catalog
Number
Newport Harbor Mate (Marina)
and Camp Mate (RV)
Amber lens—three-piece MPL1117
Clear lens—three-piece MPL1109
Main housing MPL6000
Main door MPL6001
30–30 A faceplate 1MPL1135
30–50 A faceplate 1MPL1136
50–50 A faceplate 1MPL1137
50 A–00 faceplate 1MPL1138
30 A–00 faceplate 1MPL1139
30–30 A faceplate assembly with breakers 1MPL1135A
30–30–20 GFI faceplate assembly 1MPL1135G/RV1135G
30–50 A faceplate assembly with breakers 1MPL1136A
30–50–20 GFI faceplate assembly 1MPL1136G/RV1136G
50–50 A faceplate assembly with breakers 1MPL1137A
50–50–20 GFI faceplate assembly 1MPL1137G/RV1137G
50 A–00 faceplate assembly with breakers 1MPL1138A
50–20 GFI faceplate assembly 1MPL1138G/RV1138G
30 A–00 faceplate assembly with breakers 1MPL1139A
30–20 GFI faceplate assembly 1MPL1139G/RV1139G
Mounting brackets MPL7005
36-inch stainless steel stand MPL5506
Copper busbar with nuts and washers MPL3468
Complete busbar assembly MPL1108A
Complete three-phase busbar assembly MPL1108FA
Firehouse (Marina and RV)
Red strobe light/siren MPL3020
Firehouse top with lighting assembly and strobe
MPLFH6003A
Light fuse MPL3029
Fuse holder MPL3028
Door MPL6013
24-inch life ring MPL4201
Life ring bracket MPL4201B
Blank access panel MPL6015
Door/life ring switch (pre-2004) MPL3030
Door/life ring switch (new) MPL3050
Door hasp MPL3950
Busbar (double barrel terminal block) MPL3751
10-lb ABC Type fire extinguisher MPL8025
20-lb ABC Type fire extinguisher MPL8025X
Volume 1—Residential and Light Commercial CA08100002E—March 2019 www.eaton.com V1-T5-75
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5.5
Power Pedestals
Marina Power and Lighting Equipment
Dimensions
Approximate Dimensions in Inches (mm)
Firehouse–SS
43.50
(1104.9)
9.87
(250.6)
V1-T5-76 Volume 1—Residential and Light Commercial CA08100002E—March 2019 www.eaton.com
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5.5
Power Pedestals
Marina Power and Lighting Equipment
Smart Start
Contents
Description Page
Power Pedestals . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-48
Lighthouse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-51
Lighthouse–SS . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-55
Admiral–SS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-59
Newport Harbor Mate . . . . . . . . . . . . . . . . . . . . . . V1-T5-62
Hatteras Light. . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-66
Firehouse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-70
Smart Start
Mariner. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-77
Digital Electronic Kilowatthour Meters. . . . . . . . . . V1-T5-41
Distribution Equipment—Ground Fault Monitor. . . V1-T5-42
Distribution Equipment—Mega Yacht Powerpoint. V1-T5-80
Distribution Equipment—Substations . . . . . . . . . . V1-T5-83
Distribution Equipment—Panels . . . . . . . . . . . . . . V1-T5-86
Distribution Equipment—Transformers . . . . . . . . . V1-T5-87
Smart Start
Product Description
If you have transient boat
slips, Eaton Marina Power
and Lighting has developed
their newest product for
your situation.
The new “Smart Start”
pedestal is activated by the
swipe of a credit card. A kiosk
will be centrally located at the
marina and will control up to
32 power pedestals. When a
boater wants to use a slip,
they will enter the slip
number and amount of time
they would like and will then
be asked to swipe a card in
order to activate the pedestal.
Once the chosen time is up,
the pedestal will shut down.
No more free power!
The “Smart Start” pedestal
will not only prevent transient
boaters from stealing power,
but it will also eliminate the
need for 24-hour monitoring
of the slips. Boaters will be
able to come in at any time
of the day and activate a
pedestal.
Features
Lighted 316L stainless
steel kiosk enclosure
Programmable slip
time blocks
Programmable slip rates
printable receipts
Standards and Certifications
UL listing pending
Dimensions
Approximate Dimensions in
Inches (mm)
Smart Start
Height 60.05 (1525.3)
Width 14.15 (359.4)
Depth 14.24 (361.9)
Volume 1—Residential and Light Commercial CA08100002E—March 2019 www.eaton.com V1-T5-77
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5.5
Power Pedestals
Marina Power and Lighting Equipment
Mariner
Marina Power and Lighting Equipment
Contents
Description Page
Power Pedestals. . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-48
Lighthouse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-51
Lighthouse–SS . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-55
Admiral–SS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-59
Newport Harbor Mate . . . . . . . . . . . . . . . . . . . . . . V1-T5-62
Hatteras Light . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-66
Firehouse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-70
Smart Start . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-76
Mariner
Digital Electronic Kilowatthour Meters . . . . . . . . . . V1-T5-41
Distribution Equipment—Ground Fault Monitor . . . V1-T5-42
Distribution Equipment—Mega Yacht Powerpoint . V1-T5-80
Distribution Equipment—Substations . . . . . . . . . . V1-T5-83
Distribution Equipment—Panels. . . . . . . . . . . . . . . V1-T5-86
Distribution Equipment—Transformers . . . . . . . . . V1-T5-87
Mariner
Product Description
The Mariner is a lighting
bollard that can stand from
1.5 to 4 feet tall and can be
used in various applications
from marina docks, to
landscaped areas, golf
courses and beyond. The
Mariner will have a lifetime
warranty on the engineered
resin housing that will
withstand the harsh marine
and land environments from
Alaska to the tropics.
Features
Can be configured with a
7 watt, 9 watt or 13 watt
fluorescent bulb
Mounting base and painted
pole supplied for desired
height
Limited lifetime warranty
on engineered resin
housing
Custom colors available
Side-mounted option
Dimensions
Approximate Dimensions in
Inches (mm)
Catalog Number Selection
Mariner
7 watt 14.15 (359.4)
9 watt/13 watt 14.24 (361.9)
Mounting Base and Pole
1.5 feet–4 feet
Lighting
1 = LED
X = No lighting
Color Lens
A = Amber
C = Clear
O = Other
B = Blue
Stand Height
18 = 18-inch
24 = 24-inch
36 = 36-inch
48 = 48-inch
Type
M = Mariner Color
W= White
R= Blue
B= Black
D= Dark
N= Brown
S= Other
M 1 A R 18
V1-T5-78 Volume 1—Residential and Light Commercial CA08100002E—March 2019 www.eaton.com
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5.5
Power Pedestals
Marina Power and Lighting Equipment
Digital Electronic Kilowatt Hour Meters
Contents
Description Page
Power Pedestals . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-48
Lighthouse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-51
Lighthouse–SS . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-55
Admiral–SS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-59
Newport Harbor Mate . . . . . . . . . . . . . . . . . . . . . . V1-T5-62
Hatteras Light. . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-66
Firehouse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-70
Smart Start. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-76
Mariner. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-77
Digital Electronic Kilowatthour Meters
Distribution Equipment—Ground Fault Monitor. . . V1-T5-42
Distribution Equipment—Mega Yacht Powerpoint. V1-T5-80
Distribution Equipment—Substations . . . . . . . . . . V1-T5-83
Distribution Equipment—Panels . . . . . . . . . . . . . . V1-T5-86
Distribution Equipment—Transformers . . . . . . . . . V1-T5-87
Digital Electronic Kilowatthour Meters
Product Description
Using the latest surface
mount technology, Eaton
manufactures a digital
electronic kilowatthour meter
that exceeds the +/– 2%
accuracy required by ANSI
(American National Standards
Institute) C-12.1 and is
approved by the state of
California at +/– 1% over the
full range of 0–100 A from a
0.5–1 power factor and is
available for both single- and
three-phase applications.
The meter drives an electro-
mechanical counter that
requires a 12 V pulse each
tenth of a kilowatthour,
providing 10 pulses per
kilowatt used. The meter
output can be hard wired or
connected to a transmitter
in the pedestal for wireless
transmission to a receiver
displaying the output on a
PC for direct billing of up to
1,000 individual customers.
Features
Our meter is designed to
be user friendly in that all
connections from external
sources and the meter output
are through one 14-pin locking
connector. This feature
eliminates many common
problems, such as reverse
line polarity and improper coil
polarity. Simple LEDs, both
red and green, indicate line
and load condition and the
pulsed LED indicates the rate
of power consumption.
Wireless System
All of our meters are “wireless
capable” to allow for wireless
meter reading. This technology
enables the marina or RV park
to get meter readings from
one central location rather
than visiting every site to
read the counters.
Meter Socket Capabilities
Meter sockets are available
on the Lighthouse and
Lighthouse–SS.
Standard
Four jaw
Ring-type
100 A
Available Options
200 A (SS only)
Lockable hasp
Ringless (SS only)
Five jaw
Seven jaw (SS only)
Product Selection
One Element Meter
Two Element Meter
Three Element Meter
Volume 1—Residential and Light Commercial CA08100002E—March 2019 www.eaton.com V1-T5-79
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5.5
Power Pedestals
Marina Power and Lighting Equipment
Ground Fault Monitor
Contents
Description Page
Power Pedestals. . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-48
Lighthouse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-51
Lighthouse–SS . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-55
Admiral–SS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-59
Newport Harbor Mate . . . . . . . . . . . . . . . . . . . . . . V1-T5-62
Hatteras Light . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-66
Firehouse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-70
Smart Start . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-76
Mariner . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-77
Digital Electronic Kilowatthour Meters . . . . . . . . . . V1-T5-41
Distribution Equipment—Ground Fault Monitor
Distribution Equipment—Mega Yacht Powerpoint . V1-T5-80
Distribution Equipment—Substations . . . . . . . . . . V1-T5-83
Distribution Equipment—Panels. . . . . . . . . . . . . . . V1-T5-86
Distribution Equipment—Transformers . . . . . . . . . V1-T5-87
Distribution Equipment—Ground Fault Monitor
Product Description
Our ground fault monitoring
systems are designed to
detect fault currents in the
AC shore power system that
are too low to trip a circuit
breaker. The ground fault
monitor helps reduce the risk
of injury or property damage
that may result from stray
fault currents. Our ground
fault monitoring system
provides information to the
maintenance staff on the
overall condition of the AC
electrical system. The ground
fault monitoring system
operates 24 hours a day and
can be monitored by non-
technical personnel.
Features
Adjustable trip level 10 mA
to 10 A
Current transformers up to
8 1/4-inch diameter
Visual and/or audible alarm
Housing of fiberglass or
powder-coated stainless
steel available
Power Guard
The ground fault monitor
detects ground fault currents
by means of current
transformers (CT), which are
placed around main or branch
circuits. If a ground fault
occurs, the CT will detect the
amount of fault current and
send a signal to the ground
fault monitoring device where
the amount of fault current is
displayed with the faulty
circuit identified. The
detected fault can either
activate an indicator alarm or
disconnect the faulted circuit.
Standards and Certifications
UL listed current
transformers
V1-T5-80 Volume 1—Residential and Light Commercial CA08100002E—March 2019 www.eaton.com
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5.5
Power Pedestals
Marina Power and Lighting Equipment
Marina Power and Lighting Equipment
Contents
Description Page
Power Pedestals . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-48
Lighthouse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-51
Lighthouse–SS . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-55
Admiral–SS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-59
Newport Harbor Mate . . . . . . . . . . . . . . . . . . . . . . V1-T5-62
Hatteras Light. . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-66
Firehouse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-70
Smart Start. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-76
Mariner. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-77
Digital Electronic Kilowatthour Meters. . . . . . . . . . V1-T5-41
Distribution Equipment—Ground Fault Monitor. . . V1-T5-42
Distribution Equipment—Mega Yacht Powerpoint
Wiring Diagram . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-81
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-82
Distribution Equipment—Substations . . . . . . . . . . V1-T5-83
Distribution Equipment—Panels . . . . . . . . . . . . . . V1-T5-86
Distribution Equipment—Transformers . . . . . . . . . V1-T5-87
Distribution Equipment—Mega Yacht Powerpoint
Product Description
From the company that is
known for its high-quality
innovations, Eaton is the only
company to offer a self-
contained dual-phase mega
yacht unit. Made out of long-
lasting stainless steel, this
mega yacht unit has a
copper-wound, low-noise
transformer that is double
insulated and epoxy
overcoated.The mega yacht
unit delivers both single-
phase and three-phase power
to serve most mega yachts.
Helping to keep your marina
environment tranquil, the
mega yacht unit has a
low-noise, highly efficient
transformer that has isolation
mounts to ensure a very
quiet operation.
Features
Thermostatically controlled
fans in transformer
compartment for cooling
Heavy stainless steel
(316L) cabinet with a
polyester powder coating
Ventilated sun shields to
help unit run cooler in
tropical climates
Limited lifetime warranty
on housing
Two or three light 13 watt
photocell controlled
fluorescent lights on
the sun shield for optimal
night lighting
Available Options
200 A–480 V three-phase
receptacles
100% rated breakers
Hard wiring busbars for
all voltages with breaker
protection
Two 3/4 inch water outlets
with a water meter
Two phone, two CATV
and two CAT5 high-speed
Internet connections
Digital electronic meters
on all receptacles
Primary breaker
Two 480 V delta or wye
125 A three-phase
receptacles (IEC)
Two 120/208 V 100 A
three-phase receptacles
(IEC)
Two 120/240 V 100 A
single-phase receptacles
(IEC)
Up to four 50 A 120/240 V
locking receptacles
(NEMA)
Up to four 30 A 120 V
locking receptacles
(NEMA)
Wireless remote metering
for electric and water
20 A GFI receptacle
Primary side 480 V
maximum 600 A
Secondary side single-
phase 120/240 V maximum
100 kVA
Secondary side three-
phase 120/208 V maximum
125 kVA
Fire extinguisher—10 or
20 lbs
Volume 1—Residential and Light Commercial CA08100002E—March 2019 www.eaton.com V1-T5-81
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5.5
Power Pedestals
Marina Power and Lighting Equipment
Wiring Diagram
Powerpoint
N
120/240V
100A 1Ø
2-Pole
Breaker
120/240V
100A 1Ø
2-Pole
Breaker
120/208V
100A 3Ø
3-Pole
Breaker
120/208V
100A 3Ø
3-Pole
Breaker
120/208V
100A 3Ø
3-Pole
Breaker
480V
100A 3Ø
3-Pole
Breaker
480V
100A 3Ø
3-Pole
Breaker
480V
100A 3Ø
3-Pole
Breaker
G
N
G
N
G
N
G
1 2 3
1 2 3
1 2 3
120/240V Single-Phase Supply 120/240V Three-Phase Supply
3 Ø, 277/480V
Supply from
Main Breaker
3 Ø, 277/480V
Supply from
Main Breaker
3 Ø, 277/480V
Supply from
Main Breaker
480V
3Ø 3-Pole
Main
Breaker
N
G
N
G
NG
Dual-Phase Primary
Transformer 480V
277/480V Supply
from Utility
To 480V
Service
CT for
Electronic
Meter (Typ.)
200A Hard Wire Buss
277/480V
(Ground & Neutral
from Utility Supply)
1
N
32
AB AB
ABO
100A Hard
Wire Buss
120/480V
V1-T5-82 Volume 1—Residential and Light Commercial CA08100002E—March 2019 www.eaton.com
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5.5
Power Pedestals
Marina Power and Lighting Equipment
Dimensions
Approximate Dimensions in Inches (mm)
Powerpoint Unit
Top With Solar Shield
Front
Base
Right SideLeft Side
46.00 (1168.4)
48.54
(1232.9)
31.00
(787.4)
26.00
(660.4)
26.00
(660.4)
Ø 0.50
(Ø 12.7)
Volume 1—Residential and Light Commercial CA08100002E—March 2019 www.eaton.com V1-T5-83
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5.5
Power Pedestals
Marina Power and Lighting Equipment
Double Panel Substation
Substations
Contents
Description Page
Power Pedestals. . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-48
Lighthouse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-51
Lighthouse–SS . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-55
Admiral–SS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-59
Newport Harbor Mate . . . . . . . . . . . . . . . . . . . . . . V1-T5-62
Hatteras Light . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-66
Firehouse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-70
Smart Start . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-76
Mariner . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-77
Digital Electronic Kilowatthour Meters . . . . . . . . . . V1-T5-41
Distribution Equipment—Ground Fault Monitor . . . V1-T5-42
Distribution Equipment—Mega Yacht Powerpoint . V1-T5-80
Distribution Equipment—Substations
Features, Benefits and Functions . . . . . . . . . . . V1-T5-44
Available Options. . . . . . . . . . . . . . . . . . . . . . . . V1-T5-45
Standards and Certifications . . . . . . . . . . . . . . . V1-T5-45
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-45
Distribution Equipment—Panels. . . . . . . . . . . . . . . V1-T5-86
Distribution Equipment—Transformers . . . . . . . . . V1-T5-87
Distribution Equipment—Substations
Product Description
The introduction of
substations into the marina
and recreational vehicle
market allows Eaton to be
your complete marina and RV
park electrical products
supplier. We are able to
assist in the design and
layout of your marina or RV
park electrical system from
the primary service provider,
to your power pedestal.
Our substations are designed
for any coastal or inland
environment and are
constructed of powder-
coated stainless steel NEMA
3R housing cabinets. All
substation cabinets come
with our limited lifetime
warranty. All of our
substations use Eaton’s
panels and circuit breakers
providing our customers the
utmost in circuit protection
and quality.
Application Description
The aluminum and Galvaneal
cabinets are recommended
for inland applications.
The substations can be
configured with 50–330 kVA
single-phase or three-phase
copper wound transformers
and up to 20 single-phase or
12 three-phase branch
breakers. An optional three-
sided double-wall cabinet is
available that provides air
flow between the panels. All
substations come standard
with temperature controlled
cooling fans.
Product Selection Guide
Panel and Transformer
Combinations
Panel Transformer
Single-Phase
200 A 50 kVA
300 A 75 kVA
400 A 100 kVA
600 A 150 kVA
700 A 167.5 kVA
800 A 200 kVA
1000 A 250 kVA
1200 A 330 kVA
Three-Phase
100 A 45 kVA
200 A 75 kVA
300 A 112.5 kVA
400 A 150 kVA
600 A 225 kVA
800 A 300 kVA
V1-T5-84 Volume 1—Residential and Light Commercial CA08100002E—March 2019 www.eaton.com
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5.5
Power Pedestals
Marina Power and Lighting Equipment
Features, Benefits
and Functions
Limited lifetime warranty
on the housing
All stainless steel
hardware
Temperature controlled
cooling fans in the
transformer and circuit
breaker compartments
Lockable door
Ventilation
The substation ventilation
is designed to optimize air
circulation over and around
the transformers and through
the panel compartment so
that the substation operates
at lower temperatures.
Substations come equipped
with temperature controlled
cooling fans for exhausting
hot air from the cabinet and
solar shield.
In addition, substations are
available with a double-
walled cabinet and solar
shield, which allow for
cooling of both the exterior
surface of the cabinet and
the internal components.
Substations
Stainless steel housing
with polyester
powder coating
Limited
lifetime
warranty
on the
housing
Stainless steel hardware
with locking doors
Temperature-controlled
fans for coolin g
Custom made to your specifications:
Single-phase or three-phase copper
wound transformers
50 to 330 kVA
Up to 1200 A main circuit breaker with
20 single-phase or 12 three-phase
branch circuit breakers
Sun Heat
Transformers
Air
Cool Air
Double-Walled
Stainless
Double-Walled Construction
Volume 1—Residential and Light Commercial CA08100002E—March 2019 www.eaton.com V1-T5-85
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5.5
Power Pedestals
Marina Power and Lighting Equipment
Available Options
Powder-coated cabinets
made of stainless steel
or fiberglass
Limited lifetime warranty
on housing. Transformer
and secondary distribution
panel in a single enclosure
have a one-year limited
warranty
Stainless steel housing
and hardware with
locking doors
Single-phase and three-
phase models
Overload capacity meets
ANSI L57.96–01.250
Optional double-walled
construction
Temperature controlled
fans for cooling
Custom-made copper
wound single-phase or
three-phase transformers
from 50–330 kVA
Up to 1200 A main circuit
breaker with 15 single-
phase branch circuit
breakers or 10 three-phase
branch circuit breakers
Substations can be
equipped with photocells
to turn on and off lights
A 20 A GFI can be installed
in the cabinet, as well as
a ground fault monitoring
system
Standards and Certifications
cULus listed
Dimensions
Approximate Dimensions in
Inches (mm)
Substations
Standard Substation
Height 53.00 (1346.2)
Width 51.00 (1295.4)
Depth 33.00 (838.2)
Side-by-Side Substation
Height 53.00 (1346.2)
Width 66.00 (1676.4)
Depth 30.00 (762.0)
Double Panel Substation
Height 53.00 (1346.2)
Width 63.00 (1600.2)
Depth 33.00 (838.2)
V1-T5-86 Volume 1—Residential and Light Commercial CA08100002E—March 2019 www.eaton.com
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5.5
Power Pedestals
Marina Power and Lighting Equipment
Panel (Stainless Steel Shown)
Panels
Contents
Description Page
Power Pedestals . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-48
Lighthouse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-51
Lighthouse–SS . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-55
Admiral–SS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-59
Newport Harbor Mate . . . . . . . . . . . . . . . . . . . . . . V1-T5-62
Hatteras Light. . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-66
Firehouse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-70
Smart Start. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-76
Mariner. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-77
Digital Electronic Kilowatthour Meters. . . . . . . . . . V1-T5-41
Distribution Equipment—Ground Fault Monitor. . . V1-T5-42
Distribution Equipment—Mega Yacht Powerpoint. V1-T5-80
Distribution Equipment—Substations . . . . . . . . . . V1-T5-83
Distribution Equipment—Panels
Distribution Equipment—Transformers . . . . . . . . . V1-T5-87
Distribution Equipment—Panels
Product Description
Two of the many products
we can offer our customers
are Eaton’s PRL-3A and
PRL-4 panels as standalone
units or in one of our
substations. All of our busses
are made of copper and are
load rated; breakers are
bolt-on type. Distribution
panels can be 120/240 V
single-phase, 120/208 V
three-phase, 277/480 V three-
phase or 220Y/127 V three-
phase based on your system
requirements. Distribution
panels can also have a main
breaker or a main lug. Branch
circuit breakers are provided
based on customer
requirements.
Features
All internal wiring is
fine stranded 1000 V
insulated copper
Copper busbars
All exterior hardware
is stainless steel
Available Options
NEMA 3R or 4X
Powder-coated
stainless steel
Main breaker up to 1200 A
Branch breaker 20–1200 A
Main lug only
We also offer 480 V
models—single-phase
and three-phase
Single-Phase
Up to 1200 A main
circuit breakers
Up to 42 branch
circuit breakers
Three-Phase
Up to 1200 A main
circuit breakers
Up to 42 branch
circuit breakers
Standards and Certifications
UL listed
cULus listed
Volume 1—Residential and Light Commercial CA08100002E—March 2019 www.eaton.com V1-T5-87
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5.5
Power Pedestals
Marina Power and Lighting Equipment
Three-Phase Transformer
Transformers
Contents
Description Page
Power Pedestals. . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-48
Lighthouse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-51
Lighthouse–SS . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-55
Admiral–SS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-59
Newport Harbor Mate . . . . . . . . . . . . . . . . . . . . . . V1-T5-62
Hatteras Light . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-66
Firehouse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-70
Smart Start . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-76
Mariner . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-77
Digital Electronic Kilowatthour Meters . . . . . . . . . . V1-T5-41
Distribution Equipment—Ground Fault Monitor . . . V1-T5-42
Distribution Equipment—Mega Yacht Powerpoint . V1-T5-80
Distribution Equipment—Substations . . . . . . . . . . V1-T5-83
Distribution Equipment—Panels. . . . . . . . . . . . . . . V1-T5-86
Distribution Equipment—Transformers
Distribution Equipment—Transformers
Product Description
Because of the high humidity
and corrosive conditions of
coastal environments, our
transformers are wound with
Class H heavily insulated
copper bar and are double
dipped in tough insulating
varnish that protects the
copper, as well as reduces
the hum that is typical in
a transformer that is not
double dipped. We provide
a second overcoat of high
temperature epoxy to protect
against the severe saltwater
environment. We can provide
this transformer in single-
phase, from 50 to 500 kVA,
and three-phase, from
45 to 300 kVA.
Features
Copper wound transformer
coils double dipped in high
temperature baking varnish
All internal wiring is
fine stranded 2000 V
insulated copper
Copper busbars
Marine transformers
with epoxy overcoat
All copper-to-copper
connections
Available Options
Single-phase: 50–500 kVA
Three-phase: 45–300 kVA
Epoxy overcoat for non-
marine applications
Primary Voltages
480 wye three-phase
480 V three-phase delta
three-wire + ground
480 V single-phase
two-wire + ground
Secondary Voltages
127/220 V three-phase
wye four-wire
120/208 V three-phase
wye four-wire
120/240 V single-phase
three-wire
Marina Power Distribution
Transformer kVA Availabilities
Single-phase: 50, 75, 100,
150, 167.5, 200, 250, 330,
500 kVA
Three-phase: 45, 75, 112.5,
150, 225, 300 kVA
Standards and Certifications
cULus listed