V16
2
Specifications
TR15RA Series Derating Curve
INPUT SPECIFICATIONS:
Voltage …....………........…........................................... 90~264Vac
Frequency ………………………………………….……………..... 47 to 63Hz
Inrush Current ………………….………….................... 50A max. @240Vac
Leakage Current …………………………………………….…… 0.25mA max.
OUTPUT SPECIFICATIONS:
Hold-up Time …………………………………………… 10ms typ. @115Vac
Short Circuit Protection …………….…………… Continuous(Auto Recovery)
Over Voltage Protection ………………………….. TVS Component to Clamp
Temperature Coefficient ……………………............................... ±0.05% / ℃
GENERAL SPECIFICATIONS:
NOTE:
Isolation ……………………..……………..…… Input to output = 4,242VDC
1. Add a 0.1uF ceramic capacitor and a 10uF E.L. capacitor to output for
Operating Temperature ................................... 0 ~ 60℃(see derating curve)
Ripple & Noise measuring @20MHz BW.
Storage Temperature ……………………………...….......……........ -20~85℃
2. Voltage setpoint at 60% full load.
Humidity .................................................... 93% RH max. Non condensing
3. Line regulation measured from 100Vac to 240Vac, full load.
Cooling ………………………………….………………… Natural Convection
4. Load regulation measured from 60% to full load and from 60% to
Switching Frequency …………………………….……………. 80KHz Typical
20% load (60% +/- 40% load).
MTBF ….…… MIL-HDBK-217F, GB, at 25℃/115VAC ……. 200K hrs min.
5. Typical efficiency at 230VAC and full load at 25℃
Altitude ……………………..…………………………….……..……….. 2000m
6. ”Various TR Series adapters are PSE certified. PSE certification alone
Dimensions ……..…….. 3.173x1.885x1.705Inches (80.60x47.90x43.30mm)
is not sufficient for importation into Japan. A valid PSE mark must
Weight ……………………………………………………… 150g(0.33 Pounds)
contain the name of the importer as shown in the example below. If PSE
SAFETY AND EMC:
mark is required, the name of the registered importer must be supplied
Emission and Immunity …....................... EN55022 Class B, EN61000-6-3
to Cincon on order placement. Product labels will not contain PSE
EN61000-3-2, EN61000-3-3, EN55024, EN61204-3 , EN61000-6-1
mark if importer name is not supplied. Consult factory or local represent
Safety …………………………….… IEC60950-1, EN60950-1 , UL60950-1
tative for details”.
Mechanical Specification
Tolerance:Inches:X.XXX±0.02
Millimeters:X.XX±0.5
All Dimensions are in inches(mm)
0.874[22.20]±0.005[0.13]
3.173[80.60]
1.885[47.90]
1.704[43.30]
70.866[1800.00]±1.969[50.00]
0.712[18.10]Max
0.629[16.00]
1.515[38.50]
0.157[4.00]
0.248[6.30]
0.748[19.00]±0.019[0.50]
1.102[28.00]
0.492[12.50]±0.002[0.05]
0.669[17.00]±0.031[0.70]
1.102[28.00]
0.665[16.90]±0.011[0.30]
1.275[32.40]
1.137[28.90]
18AWG/1800mm
DC Plug type: V+ ─●)─ V-
DC Plug :Straight(ψ5.5/ψ2.1) L12mm
0.343[8.70]±0.019[0.50]
0.727[18.47]±0.002[0.05]
+
-
TR30RAM/TR15RA-A
Typical at 25˚C, nominal line and 75% load, unless otherwise Specified
0%
20%
40%
60%
80%
100%
0 10 20 30 40 50 60
Ambient Temperature(
o
C)
Rated Load(%)
20LFM(Natural Convection)