- IT / Multimedia Equipment
EN 60950-1
IEC 60950-1
UL 60950-1
- Certification Documents
www.tracopower.com/overview/thn15wi
EN 55032 class A (with external filter)
EN 55032 class B (with external filter)
EN 55032 class A (with external filter)
EN 55032 class B (with external filter)
- Electrostatic Discharge
EN 61000-4-2, ±8 kV, perf. criteria A
EN 61000-4-2, ±6 kV, perf. criteria A
- RF Electromagnetic Field
EN 61000-4-3, 10 V/m, perf. criteria A
EN 61000-4-4, ±2 kV, perf. criteria A
EN 61000-4-5, ±1 kV, perf. criteria A
- Conducted RF Disturbances
EN 61000-4-6, 3 Vrms, perf. criteria A
EN 61000-4-8, 100 A/m, perf. criteria A
EN 61000-4-8, 1000 A/m, perf. criteria A
95% max. (non condensing)
–40°C to +90°C (with Heat Sink)
2.9 %/K above 70°C (with Heat Sink)
Natural convection (20 LFM)
- Voltage Controlled Remote
On: 3.0 to 15 VDC or open circuit
Off: 0 to 1.2 VDC or short circuit
Refers to 'Remote' and '-Vin' Pin
- Remote Pin Input Current
Altitude During Operation
- Input to Output, 500 VDC
- Input to Output, 100 kHz, 1 V
1'400'000 h (MIL-HDBK-217F, ground benign)
Non-conductive FR4 (UL94 V-0 rated)
All specifications valid at nominal voltage, full load and +25°C after warm-up time unless otherwise stated.