PHOENIX CONTACT GmbH & Co. KG Page 1 / 4
http://www.phoenixcontact.com Jul 6, 2009
Extract from the online
catalog
SAC-2P-M12MSB/910/...
Order No.: 1538047
http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=1538047
Bus system cable, PROFIBUS, 2-pos., PUR violet halogen-free,
shielded, straight connector M12 B-coded on free conductor end,
length: Variable 0.2 to 40.0 m
Commercial data
Pack 1 pcs.
Customs tariff 85444290
Catalog page information Page 272 (PC-2009)
http://
www.download.phoenixcontact.com
Please note that the data given
here has been taken from the
online catalog. For comprehensive
information and data, please refer
to the user documentation. The
General Terms and Conditions of
Use apply to Internet downloads.
Technical data
General data
Nominal current IN4 A
Nominal voltage UN250 V
Number of positions 2
Volume resistance ≤ 5 mΩ
Insulation resistance ≥ 100 MΩ
Length of cable Free input (0.2 ... 40.0 m)
Ambient temperature (operation) -25 °C ... 90 °C (plug/socket)
-40 °C ... 80 °C (cable, fixed installation)
-20 °C ... 80 °C (cable, flexible installation)
General characteristics
Coding B - inverse
SAC-2P-M12MSB/910/... Order No.: 1538047
http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=1538047
PHOENIX CONTACT GmbH & Co. KG Page 2 / 4
http://www.phoenixcontact.com Jul 6, 2009
Inflammability class acc. to UL 94 V0
Surge voltage category II
Pollution degree 3
Degree of protection IP65/IP67/IP69K
Contact material CuSn
Contact surface material Ni/Au
Contact carrier material PA 66
Material of grip body TPU, hardly inflammable, self-extinguishing
Material, knurls Zinc die-cast, (nickel-plated)
Status display No
Conductor data
Cable type PROFIBUS
Cable type (abbreviation) 910
Conductor cross section 0.25 mm²
AWG signal line 24
Conductor structure, signal line 19x 0.13 mm
Core diameter including insulation 2.55 mm ±0.07 mm
External cable diameter 7.80 mm
Wire colors Red, green
External sheath, color Violet, RAL 4001
Insulation resistance ≥ 5 GΩ*km
Conductor resistance ≤ 78.4 Ω/km
Working capacitance 32 pF (core-core)
Wave impedance Nom. 150 Ω ±10 %
Nominal voltage, conductor 30 V
Test voltage Core/Core 1500 V
Type of pair shielding Aluminum-lined polyester foil
Overall twist 2 cores with 2 fillers to the core
Shielding Braided shielding made of tin-plated copper wires
Optical shield covering 80 %
Outer sheath, material PUR
Material conductor insulation Foamed PE
Conductor material Tin-plated Cu litz wires
Smallest bending radius, fixed installation Min. 78 mm
Smallest bending radius, movable installation Min. 78 mm
SAC-2P-M12MSB/910/... Order No.: 1538047
http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=1538047
PHOENIX CONTACT GmbH & Co. KG Page 3 / 4
http://www.phoenixcontact.com Jul 6, 2009
Number of bending cycles 5000000
Bending radius 78 mm
Traversing path 10 m
Traversing rate 3 m/s
Acceleration 7 m/s²
Flame resistance IEC 60332-1
DIN EN 50265-2-1
Drawings
Dimensioned drawing
M12 x 1 male connector, straight, shielded
Circuit diagram
Contact assignment of the M12 plug
Schematic diagram
Pin assignment M12 male connector, 5-pos., B-coded, male side
SAC-2P-M12MSB/910/... Order No.: 1538047
http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=1538047
PHOENIX CONTACT GmbH & Co. KG Page 4 / 4
http://www.phoenixcontact.com Jul 6, 2009
Address
PHOENIX CONTACT GmbH & Co. KG
Flachsmarktstr. 8
32825 Blomberg,Germany
Phone +49 5235 3 00
Fax +49 5235 3 41200
http://www.phoenixcontact.com
© 2009 Phoenix Contact
Technical modifications reserved;