http://www.tracopower.com Page 2 of 3
All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated.
DC/DC Converters
THD 10WIN Series 10 Watt
Input Specifications
Input current at no load 24 Vin models: 30 mA typ.
48 Vin models: 20 mA typ.
Recommended input fuse (slow blow) 24 Vin models: 2000 mA
48 Vin models: 1000 mA
Start-up voltage / under voltage shut down 24 Vin models: 9 VDC / 8.5 VDC (or lower)
48 Vin models: 18 VDC / 17 VDC (or lower)
Surge voltage (1 sec. max.) 24 Vin models: 50 V max.
48 Vin models: 100 V max.
Conducted noise EN 55022 class A without external components
ESD (electrostatic discharge) EN 61000-4-2, air ±8 kV, contact ±6 kV,
perf. criteria A
Radiated immunity EN 61000-4-3, 10 V/m, perf. criteria A
Fast transient / surge EN 61000-4-4, ±2 kV, perf. criteria A
EN 61000-4-5, ±1 kV perf. criteria A
with external capacitor chemi-con KY 220 μF, 100 V
Conducted immunity EN 61000-4-6, 10 Vrms, perf. criteria A
Output Specifications
Voltage set accuracy ±2 % max.
Regulation – Input variation Vin min. to Vin max. 1.0 % max.
– Load variation 0 – 100 % single output models: 1.2 % max.
dual output models balanced load: 2.0 % max.
Minimum load not required
Temperature coefficient ±0.02 %/K
Ripple and noise (20 MHz Bandwidth) 100 mVp-p max.
Transient recovery time (25% load step change) 300 μS response time typ.
Transient response deviation (25% load step change) ±5 % max.
Current limitation 110–150 % of Iout hiccup, automatic recovery
Short circuit protection hiccup, automatic recovery
Over load protection 150 % of Iout max. typ.
Capacitive load 3.3 & 5.1 VDC models: 1000 μF max.
12 VDC models: 470 μF max.
15 VDC models: 330 μF max.
24 VDC models: 150 μF max.
±12 VDC models: 220 μF max. (each output)
±15 VDC models: 150 μF max. (each output)
General Specifications
Temperature ranges – Operating (natural convection 20 LFM) –40°C to +85°C
– Case temperature +105°C max.
– Storage –50°C to +125°C
Derating 3.3 %/K above +70°C
Humidity (non condensing) 95 % rel H max.
Reliability, calculated MTBF (MIL-HDBK-217F, at +25°C, ground benign) 1‘000‘000 h
Isolation voltage (input/output 60 sec., rated) 1’500 VDC
Isolation capacitance (input/output, 100 KHz, 1 V) 1‘000 pF typ.
Isolation resistance (input/output, 500 VDC) >1‘000 M Ohm