http://www.tracopower.com Page 1 of 3
DC/DC Converters
THD 10WIN Series, 10 Watt
UL 60950-1
Order code Input voltage Output voltage Output current Efficiency typ.
range max.
THD 10-2410WIN 3.3 VDC 2700 mA 86 %
THD 10-2411WIN 5.1 VDC 2000 mA 85 %
THD 10-2412WIN 9 – 36 VDC 12 VDC 833 mA 87 %
THD 10-2413WIN (24 VDC nominal) 15 VDC 666 mA 87 %
THD 10-2415WIN 24 VDC 416 mA 87 %
THD 10-2422WIN ±12 VDC ±416 mA 87 %
THD 10-2423WIN ±15 VDC ±333 mA 87 %
THD 10-4810WIN 3.3 VDC 2700 mA 86 %
THD 10-4811WIN 5.1 VDC 2000 mA 85 %
THD 10-4812WIN 18 – 75 VDC 12 VDC 833 mA 87 %
THD 10-4813WIN (48 VDC nominal) 15 VDC 666 mA 87 %
THD 10-4815WIN 24 VDC 416 mA 87 %
THD 10-4822WIN ±12 VDC ±416 mA 87 %
THD 10-4823WIN ±15 VDC ±333 mA 87 %
Models
Features
UItra wide 4:1 input voltage range
Internal EMI-filter meets EN 55022,
class A without external components
High efficiency up to 87%
Operating temperature range
40°C to +85°C
No minimum load required
I/O isolation 1500 VDC
Overload protection
3-year product warranty
The THD 10WIN series is designed for an optimized cost/performance ratio of
DC/DC converters with output power of 10 Watt.
They come with an internal EMI-filter to meet EN55022, class A without external
components. General features like no minimum load requirement, overload protec-
tion and high efficiency make these converters easy to design in. With the popular
DIP-24 standard package they are also a drop in replacement for many cost critical
applications.
C B
Scheme
IEC 60950-1
http://www.tracopower.com Page 2 of 3
All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated.
DC/DC Converters
THD 10WIN Series 10 Watt
Input Specifications
Input current at no load 24 Vin models: 30 mA typ.
48 Vin models: 20 mA typ.
Recommended input fuse (slow blow) 24 Vin models: 2000 mA
48 Vin models: 1000 mA
Start-up voltage / under voltage shut down 24 Vin models: 9 VDC / 8.5 VDC (or lower)
48 Vin models: 18 VDC / 17 VDC (or lower)
Surge voltage (1 sec. max.) 24 Vin models: 50 V max.
48 Vin models: 100 V max.
Conducted noise EN 55022 class A without external components
ESD (electrostatic discharge) EN 61000-4-2, air ±8 kV, contact ±6 kV,
perf. criteria A
Radiated immunity EN 61000-4-3, 10 V/m, perf. criteria A
Fast transient / surge EN 61000-4-4, ±2 kV, perf. criteria A
EN 61000-4-5, ±1 kV perf. criteria A
with external capacitor chemi-con KY 220 μF, 100 V
Conducted immunity EN 61000-4-6, 10 Vrms, perf. criteria A
Output Specifications
Voltage set accuracy ±2 % max.
Regulation – Input variation Vin min. to Vin max. 1.0 % max.
– Load variation 0 – 100 % single output models: 1.2 % max.
dual output models balanced load: 2.0 % max.
Minimum load not required
Temperature coefficient ±0.02 %/K
Ripple and noise (20 MHz Bandwidth) 100 mVp-p max.
Transient recovery time (25% load step change) 300 μS response time typ.
Transient response deviation (25% load step change) ±5 % max.
Current limitation 110150 % of Iout hiccup, automatic recovery
Short circuit protection hiccup, automatic recovery
Over load protection 150 % of Iout max. typ.
Capacitive load 3.3 & 5.1 VDC models: 1000 μF max.
12 VDC models: 470 μF max.
15 VDC models: 330 μF max.
24 VDC models: 150 μF max.
±12 VDC models: 220 μF max. (each output)
±15 VDC models: 150 μF max. (each output)
General Specifications
Temperature ranges – Operating (natural convection 20 LFM) –40°C to +85°C
– Case temperature +105°C max.
– Storage –50°C to +125°C
Derating 3.3 %/K above +70°C
Humidity (non condensing) 95 % rel H max.
Reliability, calculated MTBF (MIL-HDBK-217F, at +25°C, ground benign) 1‘000000 h
Isolation voltage (input/output 60 sec., rated) 1500 VDC
Isolation capacitance (input/output, 100 KHz, 1 V) 1‘000 pF typ.
Isolation resistance (input/output, 500 VDC) >1‘000 M Ohm
Page 3 of 3
Specifications can be changed without notice! Make sure you are using the latest documentation, downloadable at www.tracopower.com
www.tracopower.com
DC/DC Converters
THD 10WIN Series 10 Watt
Outline Dimensions
Pin Single Dual
1Remote On/Off Remote On/Off
2–Vin (GND) –Vin (GND)
3–Vin (GND –Vin (GND
9No pin Common
11 No function –Vout
14 +Vout +Vout
16 –Vout Common
22 +Vin (Vcc) +Vin (Vcc)
23 +Vin (Vcc) +Vin (Vcc)
Pin-Out
Rev. June 27, 2018
General Specifications
Remote On/Off – On: 3.5 ... 12 VDC or open circuit
– Off: 0 ... +1.2 VDC or short circuit pin 1 and pin 2
– Off idle current: 10 mA max.
Switching frequency 330 kHz typ.
Safety standards UL/cUL 60950-1, IEC/EN 60950-1
Safety approvals – CSA certificate of compliance CAN/CSA-C22.2 No 60950-1-07, Am 1:2011
ANSI/UL Std No 60950-1, 2nd Ed, AM 1:2011
– CB test certificate IEC 60950-1:2005 2nd Ed, Am 1:2009
Certification documents www.tracopower.com/overview/thd10win
Environmental compliance – Reach www.tracopower.com/products/reach-declaration.pdf
– RoHS RoHS directive 2011/65/EU
Physical Specifications
Casing metal with non conductive baseplate
Pin copper alloy with gold plated nickel subplate
Weight 17.3 g ( 0.61 oz)
Soldering temperature (1.5mm from case for 10 sec.) max. 260°C
911
2223
23
16 14
Bottom view
15.22
2.54
20.3
(0.10)
(0.60)
(0.80)
10.2 (0.40)4.1
(0.16)
2.54 15.24 5.08
4.5
31.8
(0.10)
(0.60)
(0.20)
(0.18)
(1.25)
1
2.54 5.08
4.5
(0.20) (0.18)
15.24(0.60)
(0.10)
Dimensions in [mm], () = Inch
Pin diameter ø 0.5 ±0.05 (0.02 ±0.002)
Tolerances ±0.5 (±0.02)