PRV4
Vishay Sfernice Industrial Potentiometer
www.vishay.com For technical questions, contact: sfer@vishay.com Document Number: 50004
122 See also: Application notes Revision: 21-Sep-06
SPECIAL FEATURES
COMMAND SHAFT
Length is measured from the mounting surface to the free
end of the shaft. The screwdriver slot is aligned with the
wiper within ± 10°. Special shafts are available, in
accordance to drawings supplied by customers. We
recommend that customers should not machine shafts, in
order to avoid damage. Bending or torsion of terminals
should also be avoided.
LINEARITY
The typical linearity of linear variation law potentiometers is
± 5 %. Guaranteed linearity on request. Consult VISHAY.
MECHANICAL SPECIFICATIONS
Mechanical Travel
300° ± 5°
Operating Torque (max. Ncm)
3 typical [4.3 oz. inch]
End Stop Torque (max. Ncm)
70 [6 lb. inch]
Max Tightening Torque
of Mounting Nut (Ncm)
200 [17.3 lb. inch]
Unit Weight (max. g)
23 to 32 [0.82 oz to 1.14 oz]
ENVIRONMENTAL SPECIFICATIONS
Temperature Range - 55 °C to + 125 °C
Climatic Category 55/125/10
Sealing fully sealed
container IP67
POWER RATING CHART RESISTANCE LAWS
ELECTRICAL SPECIFICATIONS
Resistive Element cermet
Electrical Travel 270° ± 10°
Resistance Range Linear Law 20 Ω to 10 MΩ
Logarithmic Laws 100 Ω to 2.5 MΩ
Standard series 1 - 2 - 2.5 - 5
Tolerance Standard ± 20 %
On Request ± 10 %
Power Rating Linear 2 W at + 70 °C
Logarithmic 1 W at + 70 °C
Temperature Coefficient See Standard Resistance Element Data
Limiting Element Voltage (Linear Law) 500 V
Contact Resistance Variation (Typical) 1 % Rn or 3 Ω
End Resistance 4 Ω
Dielectric Strength (RMS) 1500 V
Insulation Resistance (500 VDC) 104 MΩ
040 140
125
1
0
AMBIENT TEMPERATURE IN DEGREES CELSIUS
POWER IN WATT
70
60
20 100
80
LIN. LAW “A”
LOG. LA WS “L & F”
2
100
80
60
40
20
0
0 10080604020
% CLOCKWISE SHAFT ROTATION
% TOTAL RESISTANCE
F
L
A