CII Corcom Power Line Filters Visit CorcomOs Website at www.cor.com A Series 3-Phase RFI Power Line Filters c c c c c Effective For Both Balanced and Unbalanced Three Phase Loads Ground Choke Included Made to IEC 380 Specifications Shielded Construction Both Common Mode and Differential Mode Suppression From 50 kHz to 30 MHz Case Dimensions N In. (mm) Mfr.Os Type A* Max. B Max. C Max. D .030 (.76) E .015 (.38) 20AYP6C 8.82 (224.0) 8.82 (224.0) 9.43 (239.5) 9.43 (239.5) 13.82 (351.0) 13.82 (351.0) 13.83 (351.3) 13.83 (351.3) 5.57 (141.5) 5.57 (141.5) 6.92 (175.8) 6.92 (175.8) 5.57 (141.5) 5.57 (141.5) 6.92 (175.8) 6.92 (175.8) 2.56 (65.0) 2.56 (65.0) 4.82 (122.4) 4.82 (122.4) 2.56 (65.0) 2.56 (65.0) 4.82 (122.4) 4.82 (122.4) 4.616 (117.2) 4.616 (117.2) 5.950 (151.1) 5.950 (151.1) 4.616 (117.2) 4.616 (117.2) 5.950 (151.1) 5.950 (151.1) 1.50 (38.1) 1.50 (38.1) 3.75 (95.3) 3.75 (95.3) 1.50 (38.1) 1.50 (38.1) 3.75 (95.3) 3.75 (95.3) 30AYP6C 45AYP6C 60AYP6C 20AYT6C The A series 3-phase filters are designed for 3-phase, four wire, WYE applications providing filtering in each of the three lines plus the neutral and ground line. These standard, high performance RFI power line filters may be used on a 3-phase DELTA system. The dual stage AYT provides higher performance while the single stage AYP is good for lower noise environments. The mounting brackets and the end bell kits are sold separately. The end bell mounting kit is available in two sizes. Maximum leakage current, each line-toground at 120 VAC/60 Hz is 1.4 mA and at 250 VAC/60 Hz is 3.4 mA. Phase-tophase rated voltage is 440 VAC. Phase to neutral/ground is 250 VAC. 30AYT6C 45AYT6C 60AYT6C *For end bell covering terminals and connections, add the following: 20 A and 30 A N 5.57 (141.48); 45 A and 60 A N 6.45 (163.83). FCD External Power Line Filters The FCD filters provide three phase filtering for frequency inverters and variable speed motor drives. Designed for very noisy Delta applications, they attenuate conducted interference at low and high frequency ranges and protect programmable logic controllers from RF noise on the AC power line. These filters perform best when installed on the line side of the motor drive. The FCD filters prevent noise from returning to the line enabling equipment to meet strict European regulations on RFI. Suited for field wiring applications, these filters are ideal for EMC troubleshooting and field refurbishing. The FCD filters feature side flanges for easy mounting and DIN type terminals which eliminate live metal parts allowing safe and easy connections. They can also be sold as an accessory item to motor drives sold in Europe. Maximum leakage current, each line-to-ground at 120 VAC/60 Hz is 5.7 mA and at 250 VAC/50 Hz is 9.8 mA. They are rated at 440 VAC phase-to-phase and 250 VAC phase-to-neutral/ground. S and W Series 6 to 20 Amps; 120/250 Volts, 50-60 Hz The S and W series filters will protect equipment from malfunctions due to conducted interference coming into the equipment from the line, especially line-to-line noise and transients. In addition, they combine line-to-ground interference rejection filters with additional circuitry to reduce line-to-line transients. They are also effective to control emissions in equipment using SCR and T2L circuits, for compliance with FCC Part 15, Subpart J, and VDE 0871, Level A, down 150 KHz. The W series provides an N=4 line-to-ground impedance for common mode and an N=5 impedance for line-to-line differential mode interference. The two-stage construction provides excellent suppression at high frequency. The S series is an N=2 line-to-ground impedance common mode and an N=3 impedance for line-to-line differential mode interference. The suppression allows most equipment, including switchmode power supplies, to meet FCC specifications for conducted emissions. Additional max. line amps available as special order items. H Series Filters 3 to 10 Amps; 120/250 Volts AC, 50-60 Hz All H Series filters are for use in both patient care equipment and nonpatient equipment and meet UL 544 requirements. In addition, the 10EH4C incorporates a separate ground circuit inductor to isolate the equipment chassis from power line ground at RF frequencies. Maximum Leakage Current (Line-To-Ground): .2 A at 120 VAC, 60 Hz; 5 A at 250 VAC, 50 Hz. Hipot Rating (1 Minute): Line-to-ground N 1500 VAC; Line-to-line N 1450 VDC. Operating Frequency: 50/60 Hz. Rated Voltage: 120/250 VAC. Ask about low cost versions. Stock No Stock No. Mfr.Os Type Amps 851-0700 851-0702 851-0704 851-0706 851-0750 851-0752 851-0754 851-0756 20AYP6C 30AYP6C 45AYP6C 60AYP6C 20AYT6C 30AYT6C 45AYT6C 60AYT6C 20 30 45 60 20 30 45 60 EACH 1-9 10-24 310.17 318.33 391.80 432.60 408.09 416.25 509.33 629.05 271.40 278.54 342.82 378.52 357.08 364.22 445.66 550.42 Stock No. Mfr.Os Type Description Amps 851-0775 851-0776 851-0777 851-0778 851-0780 851-0781 AA400 AA405 AA406 AA407 AA401 AA402 Mounting Bracket Mounting Bracket End Bell Kit End Bell Kit KEPS Nuts for 10 Filters KEPS Nuts for 25 Filters 20/30 45/60 20/30 45/60 N N EACH 1-9 Dimensions N In. (mm) Mfr.Os Type Amps 851-0200 25FCD10 A Max. 25 851-0202 36FCD10 36 851-0204 50FCD10 50 B Max. C Max. D EACH E Max. F 1-9 9.69 6.26 2.52 5.70 8.43 4.528 (246.13) (159.00) (64.00) (144.78) (214.12) (115.01) 9.69 6.26 2.52 5.70 8.43 4.528 (246.13) (159.00) (64.00) (144.78) (214.12) (115.01) 9.69 6.26 2.52 5.70 8.43 4.528 (246.13) (159.00) (64.00) (144.78) (214.12) (115.01) Dimensions N Inches (mm) 10-24 229.79 204.87 243.93 223.25 258.23 236.38 EACH Max. Line Amp 1-9 10-24 Stock No Mfr.Os Type A B C D E 851-0488 851-0490 851-0492 851-0494 851-0419 851-0420 851-0421 851-0413 6VS1 10VS1 20VS1 20VS6 6VW1 10VW1 20VW1 20VW6 3.86 (98.00) 3.86 (98.00) 5.23 (132.80) 5.34 (135.64) 3.86 (98.00) 3.86 (98.00) 5.23 (132.80) 5.34 (135.64) 2.080 (52.80) 2.080 (52.80) 3.380 (85.90) 3.370 (85.73) 2.080 (52.80) 2.080 (52.80) 3.380 (85.90) 3.375 (85.73) 1.53 (38.86) 1.53 (38.86) 1.53 (38.86) 1.53 (38.86) 1.53 (38.86) 1.53 (38.86) 1.53 (38.86) 1.53 (38.86) 2.938 (74.63) 2.938 (74.63) 3.750 (95.25) 3.760 (95.50) 2.938 (74.63) 2.938 (74.63) 3.750 (95.25) 3.760 (95.50) 3.34 (84.80) 3.34 (84.80) 4.20 (106.70) 4.20 (106.55) 3.34 (84.80) 3.34 (84.80) 4.20 (106.70) 4.20 (106.55) Dimensions N Inches (mm) 10-24 15.62 13.67 22.96 20.09 168.39 147.34 202.22 176.94 14.86 13.00 29.14 25.50 6 10 20 20 6 10 20 20 29.09 33.91 74.98 75.30 34.29 39.34 80.18 80.47 24.83 28.95 64.01 64.28 27.20 35.11 71.55 71.81 EACH Stock No. Mfr.Os Type A B C D E Max. Line Amp 1-24 25-49 50-99 100-499 851-0430 851-0434 851-0436 851-0438 851-0440 851-0442 851-0444 3EH1 6EH1 6EH3 10EH1 10EH3 10EH4 10EH4C 2.25 (57.2) 2.25 (57.2) 0.96 (24.4) 2.25 (57.2) 0.96 (24.4) 2.62 (66.5) 2.62 (66.5) 1.82 (46.1) 1.82 (46.1) 1.82 (46.1) 1.82 (46.1) 1.82 (46.1) 1.19 (30.2) 1.19 (30.2) 0.66 (16.7) 0.66 (16.7) 0.66 (16.7) 0.66 (16.7) 0.66 (16.7) 0.81 (20.6) 0.81 (20.6) 2.125 (53.98) 2.125 (53.98) 2.125 (53.98) 2.125 (53.98) 2.125 (53.98) 1.575 (40.01) 1.575 (40.01) 2.53 (64.2) 2.53 (64.2) 2.53 (64.2) 2.53 (64.2) 2.53 (64.2) 1.98 (50.3) 1.98 (50.3) 3 6 6 10 10 10 10 12.99 13.26 14.25 13.70 14.48 16.40 20.20 11.25 11.60 12.85 11.99 12.80 13.98 17.85 8.92 10.31 11.42 10.65 11.38 11.48 15.87 8.12 9.28 10.28 9.59 10.24 10.44 14.28 All SEV Approved except Series. Prices Subject To Change N We Always Ship At The Lowest Price In Effect ALLIED c 609 10