Low Voltage Products & Systems 14.23
ABB Inc. • 888-385-1221 • www.abb-control.com AC 1600 - 3/03
Approvals:
UL 1077 1077 1077 1077
CSA C22.2 — No.235 C22.2 — No. 235 C22.2 — No. 235 —
VDE 0641, 0660 0660 0660 0660
IEC 898, 947 898, 947 898, 947 898, 947
No. of poles: 1,2,3,4 1+N,3+N 1,2,3 1,2,3,4, 1+N,3+N 1,2,3,4,1+N,3+N
Tripping characteristic: B C,D K K
Rated currents: 6 to 63A 0.5 to 63A 0.5 to 63A 0.2 to 63A
Minimum operating voltage: 12V 12V 12V 12V
UL/CSA rated voltage & Single pole Multi pole Single pole Multi pole Single pole Multi pole Single pole Multi pole
interrupting capacity
120VAC 10kA — 10kA — 10kA — 10kA for 0.2-40A —
6kA for 50-63A
240VAC 6kA 10kA 6kA 10kA 6kA 10kA 10kA for 0.2-40A 10kA for 0.2-32A
6kA for 50-63A 6kA for 40-63A
277VAC 6kA — 6kA — 6kA — 10kA for 0.2-40A —
277/480 VAC — 6kA — 6kA — 6kA — 10kA
60VDC 10kA 10kA 10kA 10kA 10kA 10kA — —
125VDC — 10kA — 10kA — 10kA — —
Frequency: 50/60Hz (See below) 50/60Hz (see below) 50/60Hz (see below) 50/60Hz (see below)
Rated voltage
IEC single pole 240/415VAC 240/415VAC 240/415VAC 240/415VAC
60VDC 60VDC 60VDC 60VDC
IEC multi-pole 415VAC 415VAC 415VAC 415VAC
110VDC 110VDC 110VDC 110VDC
Protection category: IP20 IP20 IP20 IP20
Depth of unit per DIN 43880: 68mm 68mm 68mm 68mm
Mounting position: optional optional optional optional
Standard mounting: 35mm DIN rail 35mm DIN rail 35mm DIN rail 35mm DIN rail
Main and shunt trip terminals:
Wire size 6-40A 18-4 A WG 0.5-40A 18-4 AWG 0.5-40A 18-4 AWG 0.2-40A 18-4 AWG
50A & above 18-2 AWG 50A & above 18-2 AWG 50A & above 18-2 AWG 50A & above 18-2 AWG
Torque 17.5 in-lbs. 17.5 in-lbs. 17.5 in-lbs. 17.5 in-lbs.
Tool #2 Posidrive #2 Posidrive #2 Posidrive #2 Posidrive
Accessory terminals
Wire size 18-16 AWG 18-16 AWG 18-16 AWG 18-16 AWG
Torque 4.5 in-lbs. 4.5 in-lbs. 4.5 in-lbs. 4.5 in-lbs.
Tool #1 Posidrive #1 Posidrive #1 Posidrive #1 Posidrive
Service life at rated load: In < 32 A, 20,000 operations In < 32 A, 20,000 operations In < 32 A, 20,000 operations In < 32 A, 20,000 operations
I
n > 32 A, 10,000 operations In > 32 A, 10,000 operations In > 32 A, 10,000 operations In > 32 A, 10,000 operations
Ambient temperatures: -25°C to +55°C -25°C to +55°C -25°C to +55°C -25°C to +55°C
Storage temperatures -40°C to + 70°C -40°C to + 70°C -40°C to + 70°C -40°C to + 70°C
Shock resistance: 30g minimum of 2 impacts, 30g minimum of 2 impacts, 30g minimum of 2 impacts, 30g minimum of 2 impacts,
shock duration of 13ms shock duration of 13ms shock duration of 13ms shock duration of 13ms
Vibration resistance: 5g, 20 cycles, 5 Hz, 150 Hz 5g, 20 cycles, 5 Hz, 150 Hz 5g, 20 cycles, 5 Hz, 150 Hz 5g, 20 cycles, 5 Hz, 150 Hz
@ 0.8 ~ In @ 0.8 ~ In @ 0.8 ~ In @ 0.8 ~ In
Disconnecting neutral rating: 6kA switching 6kA switching 6kA switching —
Technical data
S260, S270, & S280
Item S260-B S260-C, -D S270-K S280-K
Infl uence of frequency on electro-magnetic trips
Magnetic trip values shown on trip curves are valid for 50/60Hz ap pli ca tions. For
frequencies other than 50/60Hz, the mag net ic (in stan ta neous) trip values are
increased by the factor given below:
16 2/3 - 60Hz 100Hz 200Hz 400Hz DC
Approx. factor 1 1.1 1.2 1.5 1.5
Thermal tripping is independent of frequency.
1 Available for purchase. See page 14.19.