Preliminary Thyristor Product Catalog
http://www.teccor.com Teccor Electronics
- 4 972-580-7777
(OHFWULFDO6SHFLILFDWLRQV
Electrical Specificati on Notes
(1) Pulse width ≤ 10µs.
(2) TC = TJ for test conditions in off-state.
(3) For more than one full cycle rating, see Figure 1.2
(4) See Figure 1.1 for VGT vs TC
(5) See Figure 1.6 for IGT vs TC
(6) See Figure 1.5 for IH vs TC
(7) 4.0A devices also have a pulse peak forward current on-state rat-
ing (repetitive) of 75A. This rating applies for operation at 60Hz,
75°C maximum tab (or anode) lead temperature, switching from
80V peak, sinusoidal current pulse width of 10µs minimum, 15 µs
maximum.
(8) Test conditions as follows:
TC ≤ 80°C, rectangular current waveform; rate-of-rise of current
≤10A/µs. Rate-of-reversa l of current ≤ 5A/µs. ITM = 1A (50µs
pulse) Repetition Rate = 60pps. VRRM = Rated. VR = 15V mini-
mum, VDRM = Rated. Rate-of-rise reapplied forward blocking volt-
age = 5V/µs. Gate Bias = 0V, 100Ω (during turn-off time interval)
(9) See Figure 1.3 and 1.4 for current rating at specified operating
case temperature.
General Notes
•All measurements are made at 60Hz with a resistive load at an
ambient temperature of +25°C unless otherwise specified.
•Operating temperature range (TJ) is -40°C to +110 °C
•Storage temperature range (TS) is -65°C to +150°C
•Lead solder temperature is a maximum of 230°C for 10 seconds
maximum; 1/16" (1.59mm) from case.
•The case temperature (TC) is measured as shown on dimensional
outline drawings. See mechanical specifications on page 6 of this
data sheet.
Figure 1.1 Norm alized DC Gate-Trigger Vo ltage vs Case Temperature
Figure 1.2 Peak Surge Current vs Surge Current Duration
Part No. IT
VDRM &
VRRM IGT IDRM & IRRM VTM VGT
Surface Mount Through Hole
TYPE
Maximum
On-State
Current
(9)
Amps
Repetitive
Peak
Off-State
Forward &
Reverse
Voltage
Volts
DC Gate
Trigger
Current
VD = 6VDC
RL = 100Ω
(5)
mAmps
Peak Off-State
Current
Gate Open
VDRM = Ma x
Rated Va lu e
(2)
mAmps
Peak
On-State
Voltage at
Max Rat-
ed RMS
Current
TC = 25°C
Volts
DC Gate
Trigger Voltage
VD = 12VDC
RL = 60Ω
(4)
Volts
TO-252AA
D-PAK TO-251AA
D-PAK IT(RMS) IT(AV) TC =
25°CTC =
110°CTC =
-40°CTC =
25°CTC =
110°C
Non Isolated Non Isolate d MIN M A X MA X MAX MAX MAX MAX MIN
10 Amps
S1010DS2 10.0 6.4 100 200 .005 0.25 1.6 1.0 0.8 0.25
S1010DS3 10.0 6.4 100 500 .005 0.25 1.6 1.0 0.8 0.25
S2010DS2 10.0 6.4 200 200 .005 0.25 1.6 1.0 0.8 0.25
S2010DS3 10.0 6.4 200 500 .005 0.25 1.6 1.0 0.8 0.25
S4010DS2 10.0 6.4 400 200 .005 0.25 1.6 1.0 0.8 0.25
S4010DS3 10.0 6.4 400 500 .005 0.25 1.6 1.0 0.8 0.25
S6010DS2 10.0 6.4 600 200 .005 0.25 1.6 1.0 0.8 0.25
S6010DS3 10.0 6.4 600 500 .005 0.25 1.6 1.0 0.8 0.25
S1010VS2 10.0 6.4 100 200 .005 0.25 1.6 1.0 0.8 0.25
S1010VS3 10.0 6.4 100 500 .005 0.25 1.6 1.0 0.8 0.25
S2010VS2 10.0 6.4 200 200 .005 0.25 1.6 1.0 0.8 0.25
S2010VS3 10.0 6.4 200 500 .005 0.25 1.6 1.0 0.8 0.25
S4010VS2 10.0 6.4 400 200 .005 0.25 1.6 1.0 0.8 0.25
S4010VS3 10.0 6.4 400 500 .005 0.25 1.6 1.0 0.8 0.25
S6010VS2 10.0 6.4 600 200 .005 0.25 1.6 1.0 0.8 0.25
S6010VS3 10.0 6.4 600 500 .005 0.25 1.6 1.0 0.8 0.25
-40 -15 +25 +65 +105 +125
0
.5
1.0
1.5
Case Temperature (TC) - ˚C
Ratio of VGT
VGT (TC = 25˚C)
8
1
2
3
4
5
6
10
20
30
40
50
60
80
100
123 54 6 7 8 10 20 30 40 60 80 100 200 300 400 600 1000
Surge Current Duration - Full Cycles
10 AMP DEVICES
SUPPLY FREQUENCY: 60 Hz Sinusoidal
LOAD: Resistive
RMS ON-STATE CURRENT: [IT(RMS)]: Max-
Rated Value at Specified Case Temperature
GATE CONTROL MAY BE LOST
DURING AND IMMEDIATELY
FOLLOWING SURGE CURRENT
INTERVAL.
OVERLOAD MAY NOT BE REPEATED
UNTIL JUNCTION TEMPERATURE
HAS RETURNED TO STEADY-STATE
RATED VALUE.
8 AMP DEVICES
6 AMP DEVICES
4 AMP DEVICES