Part Number Voltage Frequency Nb Phases Nominal
speed
Noise level
LP
Nominal
current
Starting
current power Capacitor
VHz l/s CFM mm H² o inch H² o RPM dBA mA mA WµF
146DF0182004 115 50 1 9,0 19,08 3,3 0,13 2500 26 70 120 6
115 60 111,0 23,32 4,8 0,19 3100 32 60 5
PressureAirflow
OPTIONS
Other IP levels
Salt spray protection
Shocks and vibrations protection
Marine application
Wide temperature range
Other voltages
0 5 10 15 20 25
0,00
0,02
0,04
0,06
0,08
0,10
0,12
0,14
0,16
0,18
0,20
0,0
0,5
1,0
1,5
2,0
2,5
3,0
3,5
4,0
4,5
5,0
024681012
AIRFLOW IN CFM
AIRFLOW IN l/s
STATIC PRESSURE IN mmH2O
STATIC PRESSURE IN inchH2O
80 x 80 x 25 mm
3,15 x 3,15 x 1 ''
AC AXIAL FAN
Non contractual document.
All specicaons are subject to change without prior noce.
Picture for informaon only.
For professional use only. Please refer to the conditions of use of our
catalogue. Updated on 29/06/18
CHARACTERISTICS
Weight: 0,3 Kg / 0,66 Lb
Housing in ZAMAK
Impeller in plastic UL 94 V-0
L-10 life expectancy at 40°C: 80.000 hours
Operating temperature range: -10 / +70 °C
Storage temperature: -40 / +70°C
Connection: Leads
Impedance Protected
IP20