Global Home Our Strengths Products Search Contact Technical Support Global Network About Us Home > Products > Product Category > Control Components > Timers > Analog Timers > H3DK-M / -S > Item list > H3DK-M1 AC/DC24-240 English Multi-range, Multi-mode Timer H3DK-M1 AC/DC24-240 Series Print Page Analog Timer, DC24 to 240V, AC24 to 240V 24 to 240VAC 50/60 Hz 24 to 240VDC ripple: 20% max. Start Voltage input Relay output (SPDT) Rated supply voltage Input signals Input method Control output Type Multi-range, Multi-mode Timer H3DK-M / -S Catalog about this Product Inquiry of this Product Item list of H3DK-M / -S Image Ratings/Performance Dimensions Block diagram Terminal arrangement Time ranges Operating chart As of November 11, 2015 24 to 240VAC 50/60 Hz 24 to 240VDC ripple: 20% max. Operating voltage range 85% to 110% of rated supply voltage Input signals Start Input method Voltage input High (logic) level: 20.4 to 264 VAC/DC Voltage input Low (logic) level: 0 to 2.4 VAC/DC Minimum input signal width 50 ms min. (Start input) Power consumption ( 4.5VA(at 240 VAC) Relay ON ) 1.1W(at 24 VDC) Power consumption ( (at 240 VAC) Relay OFF ) (at 24 VDC) Reset voltage 10% max. of rated supply voltage Number of time ranges 8 0.1s1.2s / 1s12s / 10s120s / 1min12min / 10min120min / 1h12h / 10h Time ranges 120h / 100h1200h ON delay, Flicker OFF start, Flicker ON start, Signal ON/OFF delay, Signal OFF delay, Operating mode Interval, Signal ON/OFF delay, One shot output Control output Type Relay output (SPDT) Switching capacities (resistive load (cos (phi) = 1)): 250VAC 5A / 30VDC 5A Control output Contact Switching capacities (resistive load (cos (phi) = 1)): 250VAC 5A / 125VDC 0.15A output Switching capacities (resistive load (cos (phi) = 1)): 250VAC 5A / 125VDC 0.1A Minimum applicable load: 10 mA at 5 VDC (failure level: P) Operating: -20 to 55 Ambient temperature Storage: -40 to 70 Ambient humidity : 2585% +/- 1% max.(FS) Accuracy of operating time +/- 1% +/- 10 ms max. in a range of 1.2 s Setting error -10 to 10% +/- 0.05 s max. (FS) Influence of voltage +/- 0.5% FS max. (+/- 0.5% +/- 10 ms max. in a range of 1.2 s) Influence of temperature +/- 2% FS max. (+/- 2% +/- 10 ms max. in a range of 1.2 s) Insulation resistance 100 M (at 500 VDC) between current carrying metal parts and non-current carrying metal parts: 2000 VAC, 50/60 Hz for 1 min Dielectric strength between control output terminals and operating circuit: 2000 VAC, 50/60 Hz for 1 min between non-continuous contacts: 1000 VAC, 50/60 Hz for 1 min between power terminals: 5 kV Impulse withstand voltage between exposed non-current-carrying metal parts: 5 kV +/- 1.5 kV (between power terminals), square-wave noise by noise simulator (pulse Noise immunity width: 100 ns/1 us, 1-ns rise) Static immunity Mulfunction: 4 kV Destruction: 8 kV Vibration resistance 10 to 55 Hz, 0.75 mm single amplitude each in X, Y, and Z directions for 2 hours (Destruction) Vibration resistance 10 to 55 Hz, 0.5 mm single amplitude each in X, Y, and Z directions for 10 min (Malfunction Shock resistance 1000 m/s**2, 3 times each 6 directions (Destruction Shock resistance 100 m/s**2, 3 times each 6 directions (Malfunction Mechanical life expectancy 10000000 operations min. (under no load at 1800 operations/h) (relayoutput) Electrical life expectancy 100000 operations min. (5 A at 250 VAC, resistive load at 360 operations/h) (relay output) Degree of protection IP30(Terminal Block: IP20) Weight (Main) Approx. 120 g Rated supply voltage As of November 11, 2015 Top of page OMRON Corporation Sitemap Terms of Use Privacy Policy (c) Copyright OMRON Corporation 2007 - 2012. All Rights Reserved.