AC hot-air circulation blower R2E225-AG01-21 for solid fuel heating systems ebm-papst Mulfingen GmbH & Co. KG Bachmuhle 2 * D-74673 Mulfingen Phone +49 7938 81-0 Fax +49 7938 81-110 info1@de.ebmpapst.com www.ebmpapst.com Limited partnership * Headquarters Mulfingen County court Stuttgart * HRA 590344 General partner Elektrobau Mulfingen GmbH * Headquarters Mulfingen County court Stuttgart * HRB 590142 Nominal data Type R2E225-AG01-21 Motor M2E068-EC Phase 1~ 1~ Nominal voltage VAC 230 230 Frequency Hz 50 60 Type of data definition fa fa Valid for approval / standard CE CE Speed min-1 2600 2800 Power input W 200 285 Current draw A 0.88 1.25 Motor capacitor F 6 6 Capacitor voltage VDB 400 400 Capacitor standard P2 (CE) P2 (CE) Min. back pressure Pa 0 0 Min. ambient temperature C -25 -25 Max. ambient temperature C 70 50 ml = max. load * me = max. efficiency * fa = running at free air * cs = customer specs * cu = customer unit Subject to alterations Item no. 11835-5-9980 * Revision 75033 * Release 2012-02-22 * Page 1 / 5 ebm-papst Mulfingen GmbH & Co. KG * Bachmuhle 2 * D-74673 Mulfingen * Phone +49 (0) 7938 81-0 * Fax +49 (0) 7938 81-110 * info1@de.ebmpapst.com * www.ebmpapst.com AC hot-air circulation blower R2E225-AG01-21 for solid fuel heating systems Technical features Mass 3.9 kg Size 225 mm Surface of rotor Uncoated Material of impeller Sheet steel, rust-resistant Number of blades 16 Motor suspension Motor mounted via brackets on one side Direction of rotation Clockwise, seen on rotor Type of protection IP 20 Insulation class "F" Humidity class F0 Max. permissible ambient motor temp. (transp./ storage) + 80 C Min. permissible ambient motor temp. (transp./storage) - 40 C Mounting position Any Condensate discharge holes None Operation mode S1 Motor bearing Ball bearing Touch current acc. IEC 60990 (measuring network Fig. 4, TN system) < 0.75 mA Motor protection Thermal overload protector (TOP) wired internally Cable exit Axial Protection class I (if protective earth is connected by customer) Product conforming to standard EN 60335-1; CE Approval CSA C22.2 Nr.100; UL 1004-1 Item no. 11835-5-9980 * Revision 75033 * Release 2012-02-22 * Page 2 / 5 ebm-papst Mulfingen GmbH & Co. KG * Bachmuhle 2 * D-74673 Mulfingen * Phone +49 (0) 7938 81-0 * Fax +49 (0) 7938 81-110 * info1@de.ebmpapst.com * www.ebmpapst.com AC hot-air circulation blower R2E225-AG01-21 for solid fuel heating systems Product drawing 1 Connection line PFA AWG20, 3 x brass lead tips crimped Connection screen U1 Blue Z brown U2 black Item no. 11835-5-9980 * Revision 75033 * Release 2012-02-22 * Page 3 / 5 ebm-papst Mulfingen GmbH & Co. KG * Bachmuhle 2 * D-74673 Mulfingen * Phone +49 (0) 7938 81-0 * Fax +49 (0) 7938 81-110 * info1@de.ebmpapst.com * www.ebmpapst.com AC hot-air circulation blower R2E225-AG01-21 for solid fuel heating systems Charts: Air flow 50 Hz Druck p f s[Pa]fur Rho=1,2kg/m^3 0 50 100 150 200 250 300 350 qv [cfm] 400 450 500 550 600 650 700 750 800 400 1,6 1,55 380 1,5 1,45 360 Measurement: LU-20206 1,4 340 1,35 4 320 1,3 1,25 300 1,2 1,15 280 1,1 3 260 1,05 1 240 0,9 pfs[Pa] 0,85 200 0,8 0,75 180 p fs_E[IN H2O] 0,95 220 Air performance measured as per ISO 5801 Installation category A. For detailed information on the measuring set-up, please contact ebm-papst. Suction-side noise levels: LwA measured as per ISO 13347 / LpA measured with 1m distance to fan axis. The values given are valid under the measuring conditions mentioned above and may vary according to the actual installation situation. With any deviation from the standard set-up, the specific values have to be checked and reviewed with the unit installed. 0,7 0,65 160 0,6 2 140 0,55 0,5 120 0,45 100 0,4 0,35 80 0,3 0,25 60 0,2 40 0,15 0 0,1 ] [Pa pfs 20 0,05 1 0 100 200 300 400 500 600 700 qv [m/h] 800 900 1.000 1.100 1.200 1.300 0 1.400 Measured values U f n Pe I qv pfs V Hz min-1 W A m3/h Pa 1 230 50 2600 200 0.88 1195 0 2 230 50 2550 214 0.93 975 140 3 230 50 2525 220 0.96 750 260 4 230 50 2605 200 0.87 490 320 U = Supply voltage * f = Frequency * n = Speed * Pe = Power input * I = Current draw * qv = Air flow * pfs = Pressure increase Item no. 11835-5-9980 * Revision 75033 * Release 2012-02-22 * Page 4 / 5 ebm-papst Mulfingen GmbH & Co. KG * Bachmuhle 2 * D-74673 Mulfingen * Phone +49 (0) 7938 81-0 * Fax +49 (0) 7938 81-110 * info1@de.ebmpapst.com * www.ebmpapst.com AC hot-air circulation blower R2E225-AG01-21 for solid fuel heating systems Charts: Air flow 60 Hz Druck p f s[Pa]fur Rho=1,2kg/m^3 0 100 200 300 400 qv [cfm] 500 600 700 800 900 520 2,1 500 2 480 1,9 Measurement: LU-20207 460 1,8 440 420 1,7 400 1,6 380 1,5 4 360 pfs[Pa] 320 1,3 300 1,2 280 1,1 3 260 1 240 220 0,9 200 0,8 180 0,7 160 2 140 0,6 120 0,5 100 0,4 80 0,3 60 0,2 40 ] [Pa pfs 20 0 p fs_E[IN H2O] 1,4 340 Air performance measured as per ISO 5801 Installation category A. For detailed information on the measuring set-up, please contact ebm-papst. Suction-side noise levels: LwA measured as per ISO 13347 / LpA measured with 1m distance to fan axis. The values given are valid under the measuring conditions mentioned above and may vary according to the actual installation situation. With any deviation from the standard set-up, the specific values have to be checked and reviewed with the unit installed. 0,1 1 0 100 200 300 400 500 600 700 800 900 qv [m/h] 0 1.000 1.100 1.200 1.300 1.400 1.500 1.600 Measured values U f n Pe I qv pfs V Hz min-1 W A m3/h Pa 1 230 60 2800 285 1.25 1285 0 2 230 60 2670 298 1.30 1035 140 3 230 60 2590 304 1.32 800 260 4 230 60 2800 281 1.23 510 360 U = Supply voltage * f = Frequency * n = Speed * Pe = Power input * I = Current draw * qv = Air flow * pfs = Pressure increase Item no. 11835-5-9980 * Revision 75033 * Release 2012-02-22 * Page 5 / 5 ebm-papst Mulfingen GmbH & Co. KG * Bachmuhle 2 * D-74673 Mulfingen * Phone +49 (0) 7938 81-0 * Fax +49 (0) 7938 81-110 * info1@de.ebmpapst.com * www.ebmpapst.com