www.osram-americas.com/LED LINEARlight FLEX(R) POWER FLEX Flexible High Output LED Module Key Features & Benefits ---- High lumen output for use in various ---- Dimmable by pulse width modulation, a method that maintains conventional lighting applications consistent color and controls ---- Flexible circuit board with self lumen output adhesive backing allows for easy installation into straight runs or curved surfaces with a radius as tight as 0.78in. ---- Long life: up to 50,000 hours (L70) minimizing maintenance frequency ---- Entire reel can be powered from ---- Modules can be field cut every one a single feed to two LEDs to achieve a customized ---- Mercury free fit with the smallest independent ---- No UV or IR emissions section comprised of 5.91in. (6 LEDs) ---- 120 Beam angle The newest version of LINEARlight FLEX POWER FLEX LED linear module provides up to 80% more lumens compared to the second generation product, 71-82 LPW and long 50,000 hours life (L70). This product is the brightest, most efficient product in our flexible product line providing 489-566 lumens/ft. and 71-82 LPW. It is available in 2700K, 3000K and 4000K color temperatures with a CRI >80. The flexibility to cut the module every one to two LEDs at designated cut points provides versatility in luminaire design. The best applications for these products include backlighting, border lighting, cove lighting, display shelf lighting, under cabinet lighting and recessed accent lighting. The LINEARlight FLEX POWER FLEX is optimally paired with OPTOTRONIC(R) 24Vdc power supplies and controls, and such systems are covered by a 5-year system warranty. Product Offering Ordering Abbreviation L68LFE/24V/827/PF L68LFE/24V/830/PF L68LFE/24V/840/PF Wattage 68 68 68 Color Temperature 2700K 3000K 4000K Application Information Applications ---- Border lighting ---- Cove lighting ---- Display shelves ---- Edge lighting ---- Path and contour marking ---- Recessed lighting ---- Signage LED259R7 9-15 Specifications and Certifications The LINEARlight FLEX POWER FLEX is UL8750 recognized for the US and Canada Class 2 Unit (UL File # E320662) C UL LISTED US The LINEARlight FLEX POWER FLEX is UL2108 listed for the US and Canada Class 2 Unit (UL File # E247649) Specification Data Catalog # Type Project Comments Prepared by Ordering Information Item Ordering European Number Abbreviation Part Number 71329 L68LFE/24V/827/PF LF06P2-W5F-827 71328 L68LFE/24V/830/PF LF06P2-W5F-830 71327 L68LFE/24V/840/PF LF06P2-W5F-840 Module Length No. of Power (feet) LEDs (W) 9.8 120 68 9.8 120 68 9.8 120 68 Input Voltage (Vdc) 24 24 24 Current Draw (Amps) 2.8 2.8 2.8 Color Temperature 2700K 3000K 4000K Lumens (lm) 4792 5168 5544 Lumens per foot 489 525 566 Watts per foot 6.9 6.9 6.9 LPW 70.5 76.0 81.5 Notes: All data is related to the entire module. Data reflects statistical mean values. Actual data may differ depending on variances in the manufacturing process. Beam angle = 120 Ordering Guide L Technology L=LED 68 Power 68 = 68 Watts LFE / 24V / Type Voltage LFE=Linear Flexible Engine 8 CRI >80 27 / Color Temperature 27 = 2700K PF POWER FLEX Power Supply Information Max. Number of Modules and Max. Length per Power Supply All Item Numbers OT17 (51622) OT50 (51598) OT75 (51514) OT96 (51520, 51522, 51626) OT240* (51627) 4c = 1.9' 12c = 5.9' 18c = 8.8' 23c (1.5r) = 11.3' 19c = 9.3' Notes: 1. In the above chart, "c" = coupon, "r" = reel 2. A coupon (Smallest Electrical Unit - SEU) is a sub-section of the module containing 6 LEDs and at a length of 5.9". Reference this bulletin's "Assembly Diagram" for details. 3. These numbers are calculated based on maximum power values 82.5W. 4. The module is designed to work with Constant Voltage power supplies only. Reference the Power Supply PIB # ECS050 for product specific information. 5. To accurately determine the maximum LED load for the application refer to "Remote Mounting Distances" Application Note (LED126). This document can be found at www.sylvania.com/led. 6. The OT240 has 3 channels at 80W each. Values represented in chart are "per channel". 7. Parallel runs may be required to achieve the numbers listed above. Please reference this bulletin's "Wiring Diagram" for product specific wiring instructions. Minimum and Maximum Ratings Parameter Operating Temperature at Tc point Storage Temperature Range Voltage Range Reverse Voltage Values -20 to +75C (-4 to +167F) -20 to +75C (-4 to +167F) 23 - 25Vdc 25Vdc Notes: 1. Exceeding maximum ratings for operating and storage temperature will reduce expected lifetime or destroy the LED module. 2. Exceeding maximum ratings for operating voltage will cause hazardous overload and will likely destroy the LED module. 3. T he temperature of the LED module must be measured at the Tc point according to EN60598-1 in a thermally constant status with a temperature sensor or a temperature sensitive label. For example location of Tc point, see drawing on next page. Accessories Item Ordering European Length Case Order Number Abbreviation Part Number Description (inches) Qty. Qty. Track Accessories 72356 LAC-T/STS/7FT LF-LTS-2100 6.9' aluminium track 83 40 1 72357 LAC-M/STS/CLIP LF-LTS-MB Optional mounting bracket for track 1.1 280 35 72360 LAC-T/STS-COV/C/7FT LF-LTS-COVER-CLEAR 6.9' clear cover for track 83 40 1 72358 LAC-T/STS-COV/D/7FT LF-LTS-COVER-DIFFUSE 6.9' diffused cover for track 83 40 1 72359 LAC-S/STS/ENDCAP LF-LTS-ENDCAP End cap used only with 72358 0.8 160 20 72361 LAC-T/STS-COV/SP/7FT LF-LTS-COVER-SHORTPITCH 6.9' diffused cover specifically 83 40 1 designed for short pitch product Connection Accessories 71428 LAC-C/TP/TERMCAP LF-2TERM FLEX Termination Cap 200 10 72671 LF-CONN Flex SC LF-CONN Flex SC Board to board connector piece 0.35 250 25 72947* LF-WIRE-30 FLEX SC LF-WIRE-30 FLEX SC 30mm connector wire 1.1 10,000 100 72948* LF-WIRE-150 FLEX SC LF-WIRE-150 FLEX SC 150mm connector wire 5.9 5000 50 72946 LF-2PIN Flex SC LF-2PIN Flex SC Input connector 20 250 10 *Use with 72671 Assembly Diagram 0.1 2.5 118.1 3000 5.91 150 4.91 124.6 3.92 99.6 .49 12.5 .31 8 .99 25.1 "X1" Cut Point If Cut Here, Attach Termination Cap SEU Cut Point If Cut Here, DO NOT attach Termination Cap "X2" Cut Point If Cut Here, Attach Termination Cap Dimensions: Inches [mm] Size of Entire Module (L x W x H) 118.1" x 0.31" x 0.1" Wiring Diagram The maximum operable length on a single feed is 1 full reel (9.8ft.). Remaining load must be connected on subsequent power feeds. Reference the "Power Supply Information" section of this PIB for module load per power supply requirements.To help reduce the effects of any potential voltage drop, if possible, it is best to locate the power supply near the middle of the run. Safety Information WARNING: ONLY QUALIFIED PERSONNEL SHOULD PERFORM INSTALLATION. TO AVOID ELECTRICAL SHOCK OR COMPONENT DAMAGE, DISCONNECT POWER BEFORE ATTEMPTING INSTALLATION OF THE POWER SUPPLIES AND/OR MODULES. Failure to install the power supplies and/or LED modules in accordance with the National Electric Code (NEC), all applicable Federal, State and local electric codes as well as the specific Underwriters Laboratories (UL) safety standards for the installation, location and application may cause serious personal injury, death, property damage and/or product malfunction. 1. T he LED module itself and all its components shall not be subjected to mechanical stress and assembly must not damage or destroy conducting paths on the circuit board. 2. O bserve correct electrical polarity, incorrect polarity may destroy the module. (Depending on the product, incorrect polarity may lead to emission of red or no light.) 3. Ensure the power supply is of adequate power to operate the total load. 4. Electrostatic Discharge (ESD) precautions shall be incorporated when handling or installing the module. (For more information, reference document # LED093 ESD Protection for LED Systems.) 5. Installation of LED modules shall be made with regard to all applicable electrical and safety standards. Only qualified personnel should be allowed to perform installations. 6. Modules may be hot to the touch. Use caution when handling. 7. D amage by corrosion and improper heat sinking will not be honored as a materials defect claim. It is the user's responsibility to ensure adequate heat sink and protection against corrosive agents such as moisture, condensation and other harmful elements. 8. A void looking directly into the light beam as the high brightness may damage eyes. 9. T he module, as manufactured, has no conformal coating and therefore offers no inherent protection against corrosion. The ability to customize the length of the module by cutting at specifically marked points is a key feature of the product and hence the reason for no factory installed conformal coating. For these reasons, it is recommended that the user complete all module modification first (cutting, wiring) and then apply a conformal coating in the final stages of installation. Assembly Information 1. The LINEARlight FLEX(R) POWER FLEX must be mounted on an appropriate metal heat sink. 2. The Smallest Electrical Unit can be removed by cutting with scissors before or after the designated solder pad. 3. The module may also be cut at points X1 or X2 (reference "Assembly Diagram" for locations). The following must be observed when making cuts at these locations: a. Observe the correct orientation of the module: The power feed must come from the side indicated in the technical drawing. b. The module must not be cut before the first two LEDs, which have the Tc Point in between them. This part would emit no light. c. To operate the desired subunits, the termination LF-2TERM must be applied. Disengage the terminations locking mechanism, slide it over the open contacts and press the locking mechanism back in place. 4. The mounting of the module is facilitated by means of the double-sided adhesive on the back-surface of the module. Care must be taken to provide a clean and dry mounting surface, free of oils or silicone coatings as well as dirt particles. The mounting substrate must have sufficient structural integrity. Take care to completely remove the adhesive backing. Once the module is appropriately positioned, press on the module with about 20N/cm2 (refer to application techniques of 3M adhesive transfer tapes). 5. Solder connections should only be performed on designated solder pads (marked "24V +/-"). During soldering, do not exceed the maximum soldering time of 10 seconds and the maximum soldering temperature of 260C. 6. Connecting soldered wires to an un-mounted module: Solder pads must not be pre-tinned. However, the wires must be pre-tinned at a max. 4 sec. at 300C. Allow solder points to completely cool down before performing the next soldering. Prevent shear, or peel forces. 7. Connecting soldered wires to a module mounted on a heat sink: Pre-tin solder pads and wires and solder for max. 3 sec. at 350C. Allow solder points to completely cool down before performing the next soldering. Prevent shear, or peel forces. 8. For applications involving exposure to humidity and dust, the module must be protected by a fixture, or housing with a suitable protection class. 9. The module can be protected against condensation by treatment with an appropriate circuit board grade conformal coating. The conformal coating should have the following features: a. Optical transparency b. UV - resistance c. Thermal expansion matching the thermal expansion of the module 15-30 x 10^-6cm/cm/K d. Low permeability of steam for all climate conditions e. Resistance against corrosive environment Note: Since this module's connectors are "Dry Location Only" rated, they must not be used as a connection means when conformal coating becomes necessary. Soldered wires are the appropriate connection means used in conjunction with conformal coating. Any of the necessary steps 2, 3, 5, 6, & 7 must be completed before conformal coating can be applied. Assembly Information (Continued) 10. The minimum bending radius is 0.78 in. The module may be bent over a smaller radius but only in regions of the circuit board containing no electronic components. Such bends should be made only once and fixed in position to avoid cyclic fatigue. 11. The thermal expansion coefficient along the length of the module is 17 x 10^-6cm/cm/K. When installing in environments with large variations in temperature (e.g. outdoor applications) and operating length of more than 2m, the use of metallic mounting surfaces is necessary. Otherwise it is advisable to use an additional thicker adhesive tape to absorb the stress of any mismatch in expansion coefficients. 12. P arallel connection is highly recommended as safe electrical mode. Serial connection is not recommended. Unbalanced voltage drop can cause hazardous overload and damage the LED module. 13. The maximum length of a coherently operable unit is one full reel. By two-pole feed in the middle or from both ends the length can be doubled. 14. When mounting on metallic or otherwise conductive surfaces, there needs to be electrical isolation at soldering points between module and mounting surface. Warranty OSRAM LED products are covered by our LED Module, OPTOTRONIC (R) Power Supply or Control Warranty. The LINEARlight FLEX(R) POWER FLEX is covered under warranty as long as the temperature at the Tc point does not exceed 75C; exceeding this temperature will void all warranties. For additional information or to download the warranty registration form, refer to the latest version of the warranty available in the Literature section of www.osram-americas.com/LED. Module Warranty: 3 years System Warranty: 5 years Americas Headquarters 100 Endicott Street Danvers, MA 01923 USA Phone 1-800-LIGHTBULB www.osram-americas.com OSRAM, OPTOTRONIC, LED CREATING TOMORROW and LINEARlight FLEX are registered trademarks of OSRAM GmbH. Specifications subject to change without notice. (c) 2015 OSRAM