DF5A6.8CJE TOSHIBA Diodes for Protecting against ESD Epitaxial Planar Type DF5A6.8CJE Diodes for Protecting against ESD Unit: mm The mounting of four devices on an ultra-compact package allows the number of parts and the mounting cost to be reduced. The zener voltage corresponds to the E24 Series. Low Terminal capacitance (between Cathode and Anode) : CT =23pF (typ.) 1.CATHODE 1 2. ANODE 3.CATHODE2 4.CATHODE3 5.CATHODE4 Maximum Ratings (Ta = 25C) Characteristic Symbol Rating Unit Power dissipation P 100 mW Junction temperature Tj 150 C Tstg -55~150 C Storage temperature range JEITA TOSHIBA 1-2W1A Weight: 0.003 g (typ.) Electrical Characteristics (Ta = 25C) Characteristic JEDEC Symbol Test Condition Min Typ. Max Unit Zener voltage VZ IZ = 5 mA 6.4 6.8 7.2 V Dynamic impedance ZZ IZ = 5 mA 25 Reverse current IR VR = 5 V 0.5 A Terminal capacitance (between Cathode and Anode) CT VR = 0 V, f = 1 MHz 23 pF Guaranteed Level of ESD Immunity Test Condition ESD Immunity Level IEC61000-4-2 (Contact discharge) 25 kV Criterion: No damage to device elements Marking Equivalent Circuit (Top View) CW 1 2004-09-06 DF5A6.8CJE IZ - VZ CT - VR 100 TOTAL CAPACITANCE CT (pF) CTpF) ZENER CURRENT IZ (mA) IZ(mA) 100 10 1 0 0.1 0 0.01 0.001 0 10 1 0 1 2 3 4 5 6 7 8 9 0 10 VZ ZENER VOLTAGE VZ (V) 2 1 2 3 4 5 6 7 VR REVERSE VOLTAGE VR (V) 8 2004-09-06 DF5A6.8CJE RESTRICTIONS ON PRODUCT USE 030619EAA * The information contained herein is subject to change without notice. * The information contained herein is presented only as a guide for the applications of our products. No responsibility is assumed by TOSHIBA for any infringements of patents or other rights of the third parties which may result from its use. No license is granted by implication or otherwise under any patent or patent rights of TOSHIBA or others. * TOSHIBA is continually working to improve the quality and reliability of its products. Nevertheless, semiconductor devices in general can malfunction or fail due to their inherent electrical sensitivity and vulnerability to physical stress. It is the responsibility of the buyer, when utilizing TOSHIBA products, to comply with the standards of safety in making a safe design for the entire system, and to avoid situations in which a malfunction or failure of such TOSHIBA products could cause loss of human life, bodily injury or damage to property. In developing your designs, please ensure that TOSHIBA products are used within specified operating ranges as set forth in the most recent TOSHIBA products specifications. Also, please keep in mind the precautions and conditions set forth in the "Handling Guide for Semiconductor Devices," or "TOSHIBA Semiconductor Reliability Handbook" etc.. * The TOSHIBA products listed in this document are intended for usage in general electronics applications (computer, personal equipment, office equipment, measuring equipment, industrial robotics, domestic appliances, etc.). These TOSHIBA products are neither intended nor warranted for usage in equipment that requires extraordinarily high quality and/or reliability or a malfunction or failure of which may cause loss of human life or bodily injury ("Unintended Usage"). Unintended Usage include atomic energy control instruments, airplane or spaceship instruments, transportation instruments, traffic signal instruments, combustion control instruments, medical instruments, all types of safety devices, etc.. Unintended Usage of TOSHIBA products listed in this document shall be made at the customer's own risk. * TOSHIBA products should not be embedded to the downstream products which are prohibited to be produced and sold, under any law and regulations. 3 2004-09-06