PJB Open Frame Power
Supply
24V 150W 1
Phase
/ PJB-24V150W
□□
A
TECHNICAL DATASHEET
All parameters are specified at 25°C ambient and AC input unless otherwise indicated.
www.DeltaPSU.com (November 2020, Rev. 05)
1
PJB
Highlights & Features
Universal AC Input (85Vac 264Vac)
Power Boost of 200% for 10 seconds
Low Inrush Current / Low Leakage Current
High efficiency and PF factor to conserve energy
Conformal coating on PCBA to protect against chemical and
dust pollutants
Remote ON/OFF (Optional)
No Load power consumption < 0.5W (Optional)
Versatile configuration options: Open Frame, L Frame,
Enclosed
Design compliance with Japan PSE (DENAN)*
* For PJB-24V150WJA/HA/GA models only
Safety Standards
CB Certified for worldwide use
Model Number: PJB-24V150W□□A
Unit Weight: Open Frame: 0.31 kg (0.68 lb)
Enclosed: 0.51 kg (2.00 lb)
Dimensions (L x W x H):
Open Frame: 160 x 75 x 37 mm (6.30 x 2.95 x 1.46 inch)
Enclosed: 188 x 85 x 47 mm (7.40 x 3.35 x 1.85 inch)
General Description
The PJB series of Open Frame Power Supply comes with universal AC input at 85Vac to 264Vac. Features are including low leakage /
Inrush current and conformal coating on the PCBAs to provide protection against dust and chemical pollutants and low power
consumption for optional. The built-in active PFC provides PF > 0.97 and fulfills Harmonic Current Emission according to IEC/EN 61000-
3-2. The feature built-in Power Boost of 200% for 10 seconds enables reserve power to be always available for reliable startup of loads
with high inrush current, thus eliminating the need of a more expensive power supply unit at higher power rating. Metal chassis and case
cover are available as options for different installation preferences.
Model Information
PJB Open Frame Power Supply
Model
Number
Input Voltage Range Rated Output
V
oltage
Rated Output Curr
ent
PJB-24V150W□□A 85-264Vac 24Vdc 6.30A
Model Numbering
CC Code
PJB 24V 150W
A
PJB Series Output Voltage Output Power Package Type
B - Open Frame
L - L Frame
C - Enclosed
J - Open Frame + Green Mode*
H - L Frame + Green Mode*
G Enclosed + Green Mode*
Remote ON/OFF Function
N - No Remote ON/OFF
R - With Remote ON/OFF
Delta Standard
* With safety approvals: IEC/EN/UL 62368-1
PJB Open Frame Power
Supply
24V 150W 1
Phase
/ PJB-24V150W
□□
A
TECHNICAL DATASHEET
All parameters are specified at 25°C ambient and AC input unless otherwise indicated.
www.DeltaPSU.com (November 2020, Rev. 05)
2
Specifications
Input Ratings / Characteristics
Nominal Input Voltage 100-240Vac
Input Voltage Range 85-264Vac
Nominal Input Frequency 50-60Hz
Input Frequency Range 47-63Hz
Input Current 1.90A typ. @ 100Vac, 0.95A typ. @ 200Vac
Efficiency at 100% Load 88.0% typ. @ 100Vac, 90.5% typ. @ 200Vac
No Load Power Consumption
Package Type : BLC 3.5W typ.
Package Type : JHG < 0.5W @100Vac & 200Vac
Max Inrush Current (Cold Start) 15A typ. @ 100Vac, 30A typ. @ 200Vac
Power Factor Correction at 100% load 0.98 typ. @ 100Vac, 0.95 typ. @ 200Vac
Leakage Current 0.2mA @ 100Vac, 0.4mA @ 240Vac
Output Ratings / Characteristics*
Nominal Output Voltage
Factory Set point Tolerance 24Vdc ±1% (initial set point tolerance from factory)
Output Voltage Adjustment Range 21.6-26.4Vdc
Output Current 6.30A (continuously operating at 24V)
12.6A (Power Boost for 10 seconds at 24V, refer to the
Output Power 151.2W (continuously operating at 24V)
302.4W (Power Boost for 10 seconds at 24V, refer to
Line Regulation < 96mV
Load Regulation < 150mV
Ripple (20MHz) < 150mVpp @ 0°C to 50°C, < 180mVpp @ -10°C
Ripple Noise (20MHz) < 150mVpp @ 0°C to 50°C, < 180mVpp @ -10°C
Start-up Time 500ms typ. @ 100Vac (100% load)
Hold-up Time 20ms typ. @ 100Vac (100% load)
Dynamic Response (Overshoot & Undershoot O/P Voltage) ± 5% @ 0-50% load and 50-100% load
(Slew Rate: 0.1A/µS)
Start-up with Capacitive Loads 8,000µF Max
*For power de-rating from 50°C to 70°C, see power de-rating on page 3
Mechanical
Case Chassis/Cover SGCC
Dimensions Open Frame
160 x 75 x 37 mm (6.30 x 2.95 x 1.46 inch)
Unit Weight Open Frame
Enclosed
0.31 kg (0.68 lb)
0.51 kg (2.00 lb)
Indicator NA
Cooling System Convection
Terminal Input JST B3P5-VH (LF)(SN)
Output V‒: JST B7P-VH (LF)(SN), V+: JST B6P-VH (LF)(SN)
Wire
AWG 22-18
Noise (1 Meter from power supply)
Sound Pressure Level (SPL) < 25dBA
PJB Open Frame Power
Supply
24V 150W 1
Phase
/ PJB-24V150W
□□
A
TECHNICAL DATASHEET
All parameters are specified at 25°C ambient and AC input unless otherwise indicated.
www.DeltaPSU.com (November 2020, Rev. 05)
3
Environment
Surrounding Air Temperature Operating -10°C to +70°C
Storage -25°C to +75°C
Power De-rating Mounting Orientation A > 50°C de-rate power by 2% / °C
< 90Vac de-rate power by 2% / V
Operating Humidity 5 to 95% RH (Non-Condensing)
Operating Altitude 0 to 5,000 Meters (16,400 ft)
Shock Test Non-Operating IEC 60068-2-27, Half Sine Wave: 50G for a duration of
11ms, 3 shocks for each 3 directions
Vibration Operating IEC 60068-2-6, Sine Wave: 10Hz to 55Hz @ 19.6m/S²
(2G peak); 10 min per cycle, 60 min per axis for all
X, Y, Z direction
Over Voltage Category
2
Pollution Degree
2
Protections
Overvoltage 27.6-33.6V, Latch Mode
Overload / Overcurrent > 220% of rated load current, Hiccup Mode,
Over Temperature Latch Mode
Short Circuit Hiccup Mode, Non-Latching
Protection Against Shock Class I with PE* connection
*PE: Primary Earth
Reliability Data
MTBF > 200,000 hrs. as per JEITA RCR-9102B
Expected Cap Life Time 10 years (115Vac, 50% load @ 40°C)
Safety Standards / Directives
Safety Entry Low Voltage SELV (EN 60950-1)
Electrical Safety
TUV Bauart
UL/cUL recognized
CCC
CB scheme
For Package type : B / L / C
EN 60950-1
UL 60950-1 and CSA C22.2 No. 60950-1
(File No. E131881)
CCC GB4943.1-2011
IEC 60950-1
TUV Bauart
UL/cUL recognized
cTUVus
CCC
CB scheme
For Package type : J / H / G
EN 62368-1
UL 60950-1 and CSA C22.2 No. 60950-1
UL 62368-1 and CSA C22.2 No. 62368-1
CCC GB4943.1-2011
IEC 62368-1
Design to meet DENAN at 100Vac - 240Vac
CE In conformance with EMC Directive 2014/30/EU &
EU/2015/863 and Low Voltage Directive 2014/35/EU
Galvanic Isolation Input to Output 3.0KVac
Input to Ground 2.0KVac
Output to Ground 0.5KVac
PJB Open Frame Power
Supply
24V 150W 1
Phase
/ PJB-24V150W
□□
A
TECHNICAL DATASHEET
All parameters are specified at 25°C ambient and AC input unless otherwise indicated.
www.DeltaPSU.com (November 2020, Rev. 05)
4
EMC
Emissions (CE&RE)
CISPR 32, EN 55032, FCC Title 47: Class B
Immunity
EN61000-6-1 (For Package Type : B
L
C)
Electrostatic Discharge IEC 61000-4-2 Criteria A1)
Air Discharge: 8kV (Level 3)
Contact Discharge: 4kV (Level 2)
Radiated Field IEC 61000-4-3 Level 2 Criteria A1)
80MHz-1GHz, 3V/M with 1kHz tone / 80% modulation
Electrical Fast Transient / Burst IEC 61000-4-4 Level 2 Criteria A1)
1kV
Surge IEC 61000-4-5 Level 3 Criteria A1)
Common Mode4): 2kV
Differential Mode
5)
: 1kV
Conducted IEC 61000-4-6 Level 2 Criteria A1)
150kHz-80MHz, 3Vrms
Power Frequency Magnetic Fields IEC 61000-4-8 Criteria A1)
Magnetic field strength 1A/Meter
Voltage Dips and Interruptions IEC 61000-4-11 100% dip; 1 cycle (20ms); Self Recoverable
Immunity
Electrostatic Discharge IEC 61000-4-2
Air Discharge: 15kV
Radiated Field IEC 61000-4-3 Level 3 Criteria A1)
80MHz-1GHz, 10V/M with 1kHz tone / 80% modulation
Electrical Fast Transient / Burst IEC 61000-4-4 Level 3 Criteria A1)
4kV
Surge IEC 61000-4-5 Level 4 Criteria A1)
Common Mode4): 4kV
Differential Mode5): 2kV
Conducted IEC 61000-4-6 Level 3 Criteria A1)
150kHz-80MHz, 10Vrms
Power Frequency Magnetic Fields IEC 61000-4-8 Level 4 Criteria A1)
Magnetic field strength 30A/Meter
Voltage Dips and Interruptions IEC 61000-4-11 100% dip; 1 cycle, Criteria B 2)
40% dip; 10 cycle, Criteria C 3)
70% dip; 25 cycle, Criteria C 3)
100% dip; 250 cycle, Criteria C 3)
Harmonic Current Emission IEC/EN 61000-3-2, Class A
Voltage Fluctuation and Flicker IEC/EN 61000-3-3
1) Criteria A: Normal performance within the specification limits
2) Criteria B: Output out of regulation, or shuts down during test. Automatically restored to normal operation after test.
3) Criteria C: Output out of regulation, shuts down during test (Need to recycle AC power cord to normal operation after test)
4) Asymmetrical: Common mode (Line to earth)
5) Symmetrical: Differential mode (Line to line)
PJB Open Frame Power
Supply
24V 150W 1
Phase
/ PJB-24V150W
□□
A
TECHNICAL DATASHEET
All parameters are specified at 25°C ambient and AC input unless otherwise indicated.
www.DeltaPSU.com (November 2020, Rev. 05)
5
Block Diagram(For Package Type : BLC)
Block Diagram(For Package Type : GHJ)
PJB Open Frame Power
Supply
24V 150W 1
Phase
/ PJB-24V150W
□□
A
TECHNICAL DATASHEET
All parameters are specified at 25°C ambient and AC input unless otherwise indicated.
www.DeltaPSU.com (November 2020, Rev. 05)
6
Item
Device
Description
1 Input Connector
2 Output Connector
3 VR
4 Remote ON/OFF (JST B2B-XH-A)
5 Chassis
Dimensions
Open Frame
L x W x H: 160 x 75 x 37 mm (6.30 x 2.95 x 1.46 inch)
L Frame
L x W x H: 188 x 85 x 47 mm (7.40 x 3.35 x 1.85 inch)
Notes
Dimensions are in mm
For information on Mounting Torque, and I/O Connector and Housing, please refer
to the Instruction Manual.
For L Frame type: There are 6 threaded mounting holes and 5 normal mounting
holes.
For Open Frame type: There are 4 normal mounting holes.
PJB Open Frame Power
Supply
24V 150W 1
Phase
/ PJB-24V150W
□□
A
TECHNICAL DATASHEET
All parameters are specified at 25°C ambient and AC input unless otherwise indicated.
www.DeltaPSU.com (November 2020, Rev. 05)
7
Item
Device
Description
1 Input Connector
2 Output Connector
3 VR
4 Remote ON/OFF (JST B2B-XH-A)
5 Cover
6 Chassis
Enclosed
L x W x H: 188 x 85 x 47 mm (7.40 x 3.35 x 1.85 inch)
Notes
Dimensions are in mm
For information on Mounting Torque, and I/O Connector and Housing, please refer
to the Instruction Manual.
For Enclosed type: There are 6 threaded mounting holes and 5 normal mounting
holes.
PJB Open Frame Power
Supply
24V 150W 1
Phase
/ PJB-24V150W
□□
A
TECHNICAL DATASHEET
All parameters are specified at 25°C ambient and AC input unless otherwise indicated.
www.DeltaPSU.com (November 2020, Rev. 05)
8
Assembly & Installation
Assembly Reference
Open Frame L Frame / Enclosed
For safety reasons, please ensure the mounted device is kept at 8mm (0.315 inch) safety distance at all sides from other components
and equipments. Please insert an insulation sheet between the system and product, if the safety distance is less than 8mm (0.315
inch).
Use flexible cable (stranded or solid) of AWG No. 22-18. Please refer to Table 1 for the recommended Housing and Terminal.
For the Remote ON/OFF function, use flexible cable (stranded or solid) of AWG No. 28-22.
Table 1
Connector (Board Mounting) Housing Terminal
Input (JST)
B3P5-VH(LF)(SN) VHR-5N
SVH-21T-P1.1
Output (JST) V- B7P-VH (LF)(SN) VHR-7N
V+
B6P-VH(LF)(SN)
VHR-6N
Remote ON/OFF
Function (Option)
B2B-XH-A(LF)(SN) XHP-2 SXH-001T-P0.6
Mounting Orientation
Any excessive twisting or bending may
damage the device’s PCB. Please
handle the device with care.
The device is not recommended to be
placed on low thermal conductive
surfaces. For example, plastics.
Prevent any foreign metal, particles or
conductors from entering the device
through the openings during
installation. It may cause: -Electric
shock; Safety hazard; Product failure.
The power supply must be mounted
by metal screws onto a grounded
metal surface. It is highly
recommended that the Earth
terminal on the connector be
connected to the grounded metal
surface.
PJB Open Frame Power
Supply
24V 150W 1
Phase
/ PJB-24V150W
□□
A
TECHNICAL DATASHEET
All parameters are specified at 25°C ambient and AC input unless otherwise indicated.
www.DeltaPSU.com (November 2020, Rev. 05)
9
Engineering Data
Convection
Output Load De-rating VS Surrounding Air Temperature
Open Frame / L Frame Enclosed
Forced Cooling (Air Velocity > 0.7m/s)
Output Load De-rating VS Surrounding Air Temperature
Air Flow Direction
Fig.1.1 De-rating for Mounting Orientation A, C
> 50°C de-rate power by 2% / °C
De-rating for Mounting Orientation B, E
> 45°C de-rate power by 2% / °C
De-rating for Mounting Orientation D
> 40°C de-rate power by 2.33% / °C
De-rating for Mounting Orientation F
> 40°C de-rate power by 1.66% / °C
Fig.1.2 De-rating for Mounting Orientation A, B, C
> 40°C de-rate power by 2% / °C
De-rating for Mounting Orientation D, E
> 30°C de-rate power by 1.66% / °C
De-rating for Mounting Orientation F
> 35°C de-rate power by 2% / °C
PJB Open Frame Power
Supply
24V 150W 1
Phase
/ PJB-24V150W
□□
A
TECHNICAL DATASHEET
All parameters are specified at 25°C ambient and AC input unless otherwise indicated.
www.DeltaPSU.com (November 2020, Rev. 05)
10
Open Frame / L Frame Enclosed
Notes
1. Power supply components may degrade, or be damaged, when the power supply is continuously used outside the shaded region,
refer to the graphs shown above.
2. If the output capacity is not reduced when the surrounding air temperature is more than the upper limit temperature, the device will
run into Over Temperature Protection. When activated, the output voltage will go into bouncing mode and will recover when the
surrounding air temperature is lowered or the load is reduced as far as necessary to keep the device in working condition.
3. Depending on the surrounding air temperature and output load delivered by the power supply, the device housing can be very hot!
4. If the device has to be mounted in any other orientation, please contact info@deltapsu.com for more details.
Output Load De-rating VS. Input Voltage
Fig.1.3 De-rating for Mounting Orientation A to F
> 60°C de-rate power by 2% / °C
Fig.1.4 De-rating for Mounting Orientation A to F
> 50°C de-rate power by 2% / °C
No output power de-rating for the input voltage
range from 90Vac to 264Vac
PJB Open Frame Power
Supply
24V 150W 1
Phase
/ PJB-24V150W
□□
A
TECHNICAL DATASHEET
All parameters are specified at 25°C ambient and AC input unless otherwise indicated.
www.DeltaPSU.com (November 2020, Rev. 05)
11
Functional Manual
Remote ON/OFF Function
You can remotely control the power supply unit to
turn ON/OFF by using an external DC source.
Follow the DC power source voltage and current
limiting defined in the table below.
Built-in Resistor Ri (ohm) Voltage Between RC+ and RC- (V) Input Current (mA)
Output ON Output OFF
1k 5-12.5 0-0.5 20 Max
Notes
1. Remote ON/OFF circuits are isolated from input, output and PE.
2. Please check if the polarity of the wire connector is the same as the external DC source. If not, the power would not turn on and the
internal components may be damaged.
3. You do not need an external resistance RO for current limit while the output voltage of external DC source is within the range of 5-
12.5V. If the output voltage exceeds 12.5V, please use the following equation for the value of current limit resistance RO.
= (3.5 + 0.006)
0.006
PJB Open Frame Power
Supply
24V 150W 1
Phase
/ PJB-24V150W
□□
A
TECHNICAL DATASHEET
All parameters are specified at 25°C ambient and AC input unless otherwise indicated.
www.DeltaPSU.com (November 2020, Rev. 05)
12
Functions
Start-up Time
The time required for the output voltage to reach 90% of its final steady state set value, after the input voltage is applied.
Rise Time
The time required for the output voltage to change from 10% to 90% of its final steady state set value.
Hold-up Time
Time between the collapse of the AC input voltage, and the output falling to 95% of its steady state set value.
Graph illustrating the Start-up Time, Rise Time, and Hold-up Time
Dynamic Response
The power supply output voltage will remain within ±5% of its steady state value, when subjected to a dynamic load from 0 to 50% and
50 to 100% of its rated current.
0 to 50% Load 50 to 100% Load
PJB Open Frame Power
Supply
24V 150W 1
Phase
/ PJB-24V150W
□□
A
TECHNICAL DATASHEET
All parameters are specified at 25°C ambient and AC input unless otherwise indicated.
www.DeltaPSU.com (November 2020, Rev. 05)
13
Power Boost
  (%)=
  ; (10 sec)
   (
) = (  ×) + (-  ×)
 
OR
-  =
 ×  (  ×)
An example of Power Boost and Average Output Power
Power Boost Peak Power
(WP)
Power Boost
Duration (TP) Duty Cycle Non-Peak
Power (WN)
Non-Peak Power
Duration (TN)
Total Time
(T)
200% 302.4W 10 sec 15% 124.52W 56.67 sec 66.67 sec
200% 302.4W 5 sec 15% 124.52W 28.33 sec 33.33 sec
150% 225W 10 sec 40% 102W 15 sec 25 sec
150% 225W 5 sec 40% 102W 7.5 sec 12.5 sec
It is not recommended to prolong the duration of Power Boost to be longer than the specified duty cycle calculation, this may cause
damage to the PSU.
Power Boost is the reserve power available
constantly that allows reliable startup to
support sudden and short spike of loads with
high inrush current typically during turn on to
remove the need of more expensive higher
rated power supply unit. After the output has
reached its steady state set value, the power
supply can support surge loads with a higher
short-term power demand up to 200% of
maximum rated load (IO
Max), for a
maximum duration of 10
seconds. The
Power Boost is also available to repeatedly
basis with according to the condition of an
average (R.M.S) output power shall not
exceed continuous operating condition or
refer to duty cycle calculation below.
PJB Open Frame Power
Supply
24V 150W 1
Phase
/ PJB-24V150W
□□
A
TECHNICAL DATASHEET
All parameters are specified at 25°C ambient and AC input unless otherwise indicated.
www.DeltaPSU.com (November 2020, Rev. 05)
14
Inrush Current
Inrush current is the peak, instantaneous, input current measured
and, occurs when the input voltage is first applied. For AC input
voltages, the maximum peak value of inrush current will occur
during the first half cycle of the applied AC voltage. This peak value
decreases exponentially during subsequent cycles of AC voltage.
Overvoltage Protection (Latch Mode)
The power supply’s overvoltage circuit will be activated when its
internal feedback circuit fails. The output voltage shall not exceed
its specifications defined on Page 3 under “Protections”. Power
supply will latch off, and require removal/re-application of input AC
voltage in order to restart.
The power supply should be latch.
Overload & Overcurrent Protections (Auto-Recovery)
The power supply’s Overload (OLP) and Overcurrent (OCP)
Protections will be activated when output current exceeds 220% of
IO (Max load). In such occurrence, the VO will start to droop and
once the power supply has reached its maximum power limit, the
protection is activated and the power supply will go into “Hiccup
mode” (Auto-Recovery). The power supply will recover once the
fault condition of the OLP and OCP is removed and IO is back within
the specifications.
It is not recommended to prolong the duration of IO when it is
<220% but >100%, since it may cause damage to the PSU.
Over Temperature Protection (Latch Mode)
As described in load de-rating section, the power supply also has
Over Temperature Protection (OTP). In the event of a higher
operating temperature at 100% load; or, when the operating
temperature is beyond what is recommended in the de-rating
graph, the OTP circuit will be activated. When activated, power
supply will latch off, until the surrounding air temperature drops to
its normal operating temperature or the load is reduced as
recommended in the de-rating graph. Removal/re-application of
input AC voltage will then be required in order to restart.
Short Circuit Protection (Auto-Recovery)
The power supply’s output OLP/OCP function also provides
protection against short circuits. When a short circuit is applied, the
output current will operate in “Hiccup mode”, as shown in the
illustration in the OLP/OCP section on this page. The power supply
will return to normal operation after the short circuit is removed.
PJB Open Frame Power
Supply
24V 150W 1
Phase
/ PJB-24V150W
□□
A
TECHNICAL DATASHEET
All parameters are specified at 25°C ambient and AC input unless otherwise indicated.
www.DeltaPSU.com (November 2020, Rev. 05)
15
Others
Conformal Coating
The Protective Coating Technology
Delta Electronics Group has designed the perfect dipping technique which penetrates everywhere including under
device, and prevents leakage. The conformal coating dipping can be applied to PCBs or circuit board. The coating
preserves the performance of precision electronic primarily by preventing ionizable contaminants such as salt
from reaching circuit nodes, where the material slumps around sharp edges. This can be a problem especially in
highly conversing atmosphere.
PFC Norm EN 61000-3-2
Line Current Harmonic content
Typically, the input current waveform is not sinusodial due to the periodical peak charging of the input capacitor.
In industrial environment, complying with EN 61000-3-2 is only necessary under special conditions. Complying to
this standard can have some technical drawbacks, such as lower efficiency as well as some commercial aspects
such as higher purchasing costs. Frequently, the user does not profit from fulfilling this standard, therefore, it is
important to know whether it is mandatory to meet this standard for a specific application.
Attention
Delta provides all information in the datasheets on an “AS IS” basis and does not offer any kind of warranty through the information for
using the product. In the event of any discrepancy between the information in the catalog and datasheets, the datasheets shall prevail
(please refer to www.DeltaPSU.com for the latest datasheets information). Delta shall have no liability of indemnification for any claim or
action arising from any error for the provided information in the datasheets. Customer shall take its responsibility for evaluation of using
the product before placing an order with Delta.
Delta reserves the right to make changes to the information described in the datasheets without notice.