■ RELIABILITY DATA
* This catalog contains the typical specification only due to the limitation of space. When you consider the purchase of our products, please check our specification.
For details of each product (characteristics graph, reliability information, precautions for use, and so on), see our Web site (http://www.ty-top.com/) or CD catalogs.
16. Thermal shock
NR30/40/50/60/80, NRV20/30,
NRH24/30, NRS20/40/50/60/80 Type Inductance change : Within ±10%
No significant abnormality in appearance.NR10050 Type
NS101, NS125Type
【Test Method and Remarks】
NR30/40/50/60/80, NRV20/30, NRH24/30, NRS20/40/50/60/80Type,
NR10050 Type,
NS101/125 Type :
The test samples shall be soldered to the test board by the reflow. The test samples shall be placed at specified temperature for specified time by step 1 to step 4 as shown
in below table in sequence. The temperature cycle shall be repeated 100 cycles.
Conditions of 1 cycle
Step Temperature (℃) Duration (min)
1ー40±3 30±3
2 Room temperature Within 3
3+85±2 30±3
4 Room temperature Within 3
17. Damp heat
NR30/40/50/60/80, NRV20/30,
NRH24/30, NRS20/40/50/60/80 Type
Inductance change : Within ±10%
No significant abnormality in appearance.
NR10050 Type
NS101, NS125Type
Inductance change : Within ±10%
No significant abnormality in appearance.
【Test Method and Remarks】
NR30/40/50/60/80, NRV20/30, NRH24/30, NRS20/40/50/60/80Type, NS101/125Type :
The test samples shall be soldered to the test board by the reflow.
The test samples shall be placed in thermostatic oven set at specified temperature and humidity as shown in below table.
Temperature 60±2℃
Humidity 90~95%RH
Time 500+24/-0 hour
21. Loading at high temperature life test
NR30/40/50/60/80, NRV20/30,
NRH24/30, NRS20/40/50/60/80 Type
Inductance change : Within ±10%
No significant abnormality in appearance.
NR10050 Type
NS101, NS125Type
Inductance change : Within ±10%
No significant abnormality in appearance.
【Test Method and Remarks】
NR30/40/50/60/80, NRV20/30, NRH24/30, NRS20/40/50/60/80Type, NS101/125 Type
:
The test samples shall be soldered to the test board by the reflow soldering.
Temperature 85±2℃
Applied current Rated current
Time 500+24/-0 hour
22. Standard condition
NR30/40/50/60/80, NRV20/30,
NRH24/30, NRS20/40/50/60/80 Type
Standard test condition :
Unless otherwise specified, temperature is 20±15℃ and 65±20%of relative humidity.
When there is any question concerning measurement result: In order to provide correlation data, the test shall be condition of 20±2℃
of temperature, 65±5% relative humidity.
Inductance is in accordance with our measured value.
NR10050 Type
NS101, NS125Type
19. Low temperature life test
NR30/40/50/60/80, NRV20/30,
NRH24/30, NRS20/40/50/60/80 Type Inductance change : Within ±10%
No significant abnormality in appearance.NR10050 Type
NS101, NS125Type
【Test Method and Remarks】
NR30/40/50/60/80, NRV20/30, NRH24/30, NRS20/40/50/60/80Type,
NR10050 Type,
NS101/125Type :
The test samples shall be soldered to the test board by the reflow. After that, the test samples shall be placed at test conditions as shown in below table.
Temperature -40±2℃
Time 500+24/-0 hour
18. Loading under damp heat
NR30/40/50/60/80, NRV20/30,
NRH24/30, NRS20/40/50/60/80 Type Inductance change : Within ±10%
No significant abnormality in appearance.NR10050 Type
NS101, NS125Type
【Test Method and Remarks】
NR30/40/50/60/80, NRV20/30, NRH24/30, NRS20/40/50/60/80Type,
NR10050 Type,
NS101/125Type
:
The test samples shall be soldered to the test board by the reflow.
The test samples shall be placed in thermostatic oven set at specified temperature and humidity and applied the rated current continuously as shown in below table.
Temperature 60±2℃
Humidity 90~95%RH
Applied current Rated current
Time 500+24/-0 hour
SMD inductor(NR□, NS series)
20. High temperature life test
NR30/40/50/60/80, NRV20/30,
NRH24/30, NRS20/40/50/60/80 Type
NR10050 Type Inductance change : Within ±10%
No significant abnormality in appearance.
NS101, NS125Type
【Test Method and Remarks】
NR10050 Type :
Recovery : At least 2hrs of recovery under the standard condition after the test, followed by the measurement within 48hrs.
Temperature 105±3℃
Time 500+24/-0 hour