ENGINEERING DATA SHEET TDH-6070/6071
ON RELEASE-FIXED PERIOD
2 PDT, 10 AMP
APPLICATION NOTES:
101
APPLICABLE SOCKETS:
S302
FEATURES
Small size and weight
High-reliability design
Hermetically sealed
High transient immunity
Long life
Low-power consumption
Reverse Polarity Protection
PRINCIPLE TECHNICAL CHARACTERISTICS
Seal:Hermetic Tested per MIL-STD-883,
Method 1014 Condition B, C 1x10-8 atm, cm3/s max
leakage
Finish: per MIL-T-10727 Tin Plate
Terminals:
TDH 6071 (Tin Plate)
TDH 6070 (Gold Plate) Solder-lug
Plug-In
Weight 1.9 Ounce max.
DESCRIPTION
The TDH-6070/71 Time Delay Relays have been designed with thick film hybrid microelectronics timing circuits
and MIL-R-6106 relays, packaged in a hermetically sealed military style enclosure. The TDH-6070/71 series are
designed to withstand severe environmental conditions encountered in military/aerospace applications. These
relays are suited for use in power control, communication circuits and many other applications where power
switching and high reliability are required over a wide temperature range.
Featuring LEACH© power and control solutions
www.esterline.com
AMERICAS
6900 Orangethorpe Ave.
P.O. Box 5032
Buena Park, CA 90622
.
.
Tel: (01) 714-736-7599
Fax: (01) 714-670-1145
EUROPE
2 Rue Goethe
57430 Sarralbe
France
.
.
Tel: (33) 3 87 97 31 01
Fax: (33) 3 87 97 96 86
ASIA
Units 602-603 6/F Lakeside 1
No.8 Science Park West Avenue
Phase Two, Hong Kong Science Park
Pak Shek Kok, Tai Po, N.T.
Hong Kong
Tel: (852) 2 191 3830
Fax: (852) 2 389 5803
Data sheets are for initial product selection and comparison. Contact Esterline Power Systems prior to choosing a component.
Date of issue: 3/06 - 76 - Page 1 of 3
ELECTRICAL SPECIFICATION TDH-6070/6071
Input (Control) Parameters
Timing:
a. Operation, Time Delay on
b. Method
c. Range
d. Accuracy
Release
Fixed Period
0.1 to 600 Seconds [6]
±10% [1]
Recycle Time 50 ms, Max [5]
Operations: (X1-X2)
a. Input & Control Voltage
b. Operating Current
c. Control Current
20-30 Vdc
150 mA, Max @ +25° C
15 mA, Max @ +25° C
Transients:
a. Positive, MIL-STD-704A, Figure9, Limit 1
b. Spike, MIL-STD-704A, 0-10 µs
c. Self-Generated
d. Susceptibility
+80 Volts Max
±600 Volts Max
±50 Volts Max
+80; -600 Volts Max
Electromagnetic Interference Per MIL-STD-461A Class 1D [3]
Power Loss 500 Microseconds[2]
Output (Load) Parameters
Contact Form
Contact Rating:
a. Resistive
b. Inductive
c. Motor
d. Lamp
2 PDT
10 Amperes
8 Amperes
4 Amperes
2 Amperes
Dielectric Strength:
a. @ Sea Level, 60 Hz
b. @ 80,000 ft., 60 Hz 1000 Vrms [4]
350 Vrms
Insulation Resistance @ 500 Vdc 1000 M [4]
GENERAL CHARACTERISTICS
Ambient Temperatures Range:
a. Operating
b. Non-Operating -55 to +125° C
-65 to +125° C
Vibration:
a. Sinusoidal, 10-2000 Hz 20 G
b. Random: 50-2000 Hz, MIL-STD-810 0.2 G2/Hz
Shock @ 6 ± 1 MS, 1/2 Sine, 3 Axis 100 G
Acceleration, in any Axis 20 G
Life at Rated Resistive Load; Minimum 100,000 operations
NUMBERING SYSTEM
Plug-in Terminal Solder Hook Terminal
TDH-6070 - 1001 TDH-6071 - 1001
| | | | | |
1 2 3 1 2 3
1. Model Number.
2. Pin Style Number.
3. Timing Range, Fixed: 100 milliseconds to 600 seconds. (See Note 6).
Date of issue: 3/06 - 77 - Page 2 of 3
MECHANICAL SPECIFICATIONS TDH-6070/6071
NOTES
[1] The accuracy specification applies for any combination of operating temperature and voltage.
For units with a timing range less than 1 second, add ±10 milliseconds to the ±10% tolerance.
[2] Transient and power loss specification are based on a maximum duty cycle of 1/50.
[3] EMI test limits will not be exceeded during the timing interval or when continuously energized
under steady state conditions, per paragraph 3.23, MIL-R-83726C.
[4] Terminals X1, X2 and Y1 must be connected together during the test. Dielectric withstanding
voltage and insulation resistance are measured at sea level between all mutually insulated
terminals and between all terminals and case.
[5] Recycle time is defined as the minimum time that power must be applied to the control
terminal to assure that the next timing cycle will be completed within the specified
timing tolerance. (Units can be recycled during timing or after time-out).
[6] A four digit number defines the time delay in milliseconds. The first
three digits are significant figures, used to define the specific time delay. The fourth
digit represents the number of zeros to follow the first three digits.
Examples: - 1001 = 1 second (1,000 milliseconds)
- 2502 = 25 seconds (25,000 milliseconds)
- 5000 = 0.5 seconds (500 milliseconds)
Date of issue: 3/06 - 78 - Page 3 of 3
1.53
0
.062 ± .002 PINS
.30
HOOK PIN
SEE DETAIL
VIEW A AND B
CAGE NO. AND
DATA CODE
(FAR SIDE)
NAMEPLATE
(NEAR SIDE)
.03
.156±.010
SILICON RUBBER
GASKET
.05
.27
PLUG-IN W/POLARIZING PIN
.15
.52
5
1.025 MAX
1.39
1.44
1.718 MAX
EVACUATION HOLE
ALL DIMENSIONS SHOWN ARE IN INCHES.
DETAIL VIEW B
DETAIL VIEW A
.26
.37
FULL RADIUS
4 PLACES
X2
X1
Y2 Y1
B
A
3
2
1
X2
1X1
Y2
2
Y1
3A
B
.30
POLARIZING PIN
.062 ±.002 DIA
.030 ±.001 DIA PINS
.062 ±.002 DIA PINS
.15
.050 DIA
2 PLACES
.080 I.D.
8 PLACES
.10
.50
.10
.20
.200 TYPICAL
30°
8 PLACES
CONTRASTING BEAD
.10
.10
.50
.10
.20
.200 TYPICAL CONTRASTING BEAD
TD
CONTRASTING BEAD
FIXED TIME DELAY
1 -X2 23 B
A
+X1
+Y1
CONTROL
20-30 VDC
20-30 VDC
0 VDC
0 VDC
X1-X2
(Y1-X2)
INPUT
VOLTAGE
CONTROL
DE-ENERGIZED
TIME DELAY
TIME DELAY ON RELEASE
ENERGIZED
Application notes N°101
DERATING OF CONTACTS FOR DC VOLTAGES
ABOVE NOMINAL RATING
To establish a standard for the derating of relay contacts is, at best, a subjective practice. Limitations are governed by the
type of relay, contact gap, maximum voltage capabilities of the relay contact system, and the contact material.
The most common method is to derate the contacts by use of the Power Formula, using the known current and voltage.
This method is valid only for Resistive Loads, and is an approximation only; keeping in mind the limitations mentioned
above.
Power = IE (Current x Voltage)
I2 E2 = 2/3 I1E1
Example:
A designer is working with a 55 volt DC system and has a relay rated at 10 amps resistive at 28 volts DC.
What is the maximum current that can be switched at 55 Vdc.
I1 = 10 Amperes
E1 = 28 VDC
E2 = 55 VDC
I2 = ? (Current ratings at 55 VDC Resistive)
I2 E2 = 2 I1 E1/3
I2 = 2 I1 E1/E23
= 2 (10 x 28)/55 x 3
= 560/165
I2 = 3.4 Amperes at 55VDC
In addition, the user should always be concerned about the following:
1. Derating contacts that are rated for less than 10 Amperes at nominal voltage.
2. Derating contacts for use in system voltages above 130 Volts DC
Date of issue: 6/00 - 14 - Page 1 of 1
ENGINEERING DATA SHEET S300, S301, S302
RELAY SOCKET
10 AMP
BASIC SOCKET SERIES DESIGNATION FOR:
Series M300 (DC Coil), M301 (DC Coil),
M302 (DC Coil), FD300, FLS300, FLR300
GENERAL CHARACTERISTICS
Crimp tool contact #22 M 22520/2-01 with turret M 22520/2-14.
Insertion and extraction tool #22 M 81969/14-01.
Crimp tool contact #16 M 22520/1-01 with turret M 22520/1-02 or MS 3191-1.
Insertion and extraction tool #16 M 81969/14-03 .
Weight 35g max.
Temperature range 70° C to +125° C.
Featuring LEACH© power and control solutions
www.leachintl.com
AMERICAS
6900 Orangethorpe Ave.
P.O. Box 5032
Buena Park, CA 90622 USA
Tel: (01) 714-736-7599
Fax: (01) 714-670-1145
EUROPE
2 Rue Goethe
57430 Sarralbe
France
Tel: (33) 3 87 97 31 01
Fax: (33) 3 87 97 96 86
ASIA
Room 501, 5/F, The Centre Mark
287 - 299 Queen's Road Central
Hong Kong
Tel: (852) 2 191 3830
Fax: (852) 2 389 5803
Data sheets are for initial product selection and comparison. Contact Leach International prior to choosing a component.
Date of issue: 8/08 - 17 - Page 1 of 4
TERMINAL LAYOUT S300, S301, S302
MOUNTING HARDWARE
Date of issue: 3/06 - 18 - Page 2 of 4
28.2
35.7
DEPTH 9 MM
DETAIL
10.16
15.24
5.08
Ø 2
DEPTH 9 MM
5.08
X1
A
B
32X2 1
A
B
32X2 1
X1
0.9
3.2
2.0
14.1
DETAIL
± 0.3
A
B
32X2 1
X1
3.2
0.9
A
B
32X2 1
X1
Y2
Y1
Ø 2
± 0.3
± 0.1
12.68
CODE A S300 CODE D S302
MOUNTING HOLE LAYOUT
CODE B S301 CODE C S301
POSITION, TOLERANCE SEE CODE B POSITION, TOLERANCE SEE CODE B
FOR M300 RELAY FOR M302 RELAY
FOR M301 RELAY, FOR K COIL FOR M301 RELAY, FOR J COIL
FOR HOLE CLEARANCE,
SEE HARDWARE CODE
CODE 7 : 05-284-15
LOOSE METRIC HARDWARE
TOP MOUNT
MOUNTING TORQUE:0,45 ±0,1 Nm
FOR RELAYS WITH CODE B TERMINALS
1.2
MOUNTING HOLE:3,6 mm
CODE 6 : 05-284-13
LOOSE UNC HARDWARE
BOTTOM MOUNT TOP MOUNT
MOUNTING TORQUE:0,45 ±0,1 Nm
MOUNTING HOLE:3,6 mm MOUNTING HOLE:3,6 mm
1.2
1.2
CODE 8 : 05-284-20
FIXED UNC STUDS PER MIL-S-12883/41 - EDIT C
BOTTOM MOUNT TOP MOUNT
MOUNTING TORQUE: NUT 4/40:0,45 ±0,1 Nm - NUT 10-32: 1,2 MAX
MOUNTING HOLE: 5,3 mm MOUNTING HOLE: 3,6 mm
MAX
2.4
MAX
3.2
CODE 2 : 05-284-00
LOOSE METRIC HARDWARE
TOP MOUNT
MOUNTING TORQUE:0,45 ±0,1 Nm
:3,6 mm
4.0
CODE 1 : 05-284-12
LOOSE UNC HARDWARE
BOTTOM MOUNT
MOUNTING TORQUE
NUT 4/40:0,45 ±0,1 Nm
NUT 10-32:1,2 MAX
:3,6 mm
MAX
2.4
CODE 3 : 05-284-07
LOOSE METRIC HARDWARE
TOP MOUNT
MOUNTING TORQUE:0,45 ±0,1 Nm
:3,6 mm
MAX
4.0
CODE 8 : 05-284-20
LOOSE UNC STUDS MIL-S-12883/41 - EDIT C
BOTTOM MOUNT TOP MOUNT
MOUNTIONG TORQUE: NUT 4/40:0,45 ±0,1 Nm - NUT 10-32: 1,2 MAX
MOUNTING HOLE: 5,3 mm MOUNTING HOLE: 3,6 mm
2.4
3.2
WIRE INSULATION DIAMETER FOR SEAL TO GROMMET S300, S301, S302
Code A
Recommended for
contact code 2
contact code 8
Dia: 1.2 ......2.4mm
Code B
Recommended for
contact code 3
contact code 9
Dia: 0.8 ......1.6mm
CONTACT SIZE AND STYLE
Y1-Y2
05 912 00
31 036 00
Crimpend to accomodate AWG22
(for product code 2+3)
Contact mating end dia 0.8mm
(for contact code 8+9)
MIL-C-39029/92-531
Bin Code colour bands or
Bin Code numbering on crimpside
Contact mating end dia 0.8mm
Code 2
05 911 00 Crimpend to
accomodate
AWG16-18-20
Contact mating
end #16
Code 3
05 911 10 Crimpend to
accomodate
AWG20-22-24
Contact mating
end #16
Code 0 Without contacts
Code 8
30 315 00 Crimpend to
accomodate
AWG16-18-20
MIL-C-39029/29-
533
Bin Code colour
bands
or Bin Code
numbering
on crimpside
Contact mating
end #16
Code 9
30 315 10 Crimpend to
accomodate
AWG20-22-24
MIL-C-39029/29-
534
Bin Code colour
bands
or Bin Code
numbering
on crimpside
Contact mating
end #16
SOCKET NUMBERING SYSTEM
S300 A 1 A 2
1-Basic socket designation________________________| | | | |
2-Terminal Layout_____________________________________| | | |
3-Mounting Hardware_______________________________________| | |
4-Grommet to seal on wire insulation__________________________| |
5-Contact size and style___________________________________________|
Date of issue: 3/06 - 19 - Page 3 of 4
MS/LEACH CROSS PART NO. AND MATING RELAYS S300, S301, S302
MS - Number LEACH P/N Contacts to accomodate wire # Applicable for relays
MIL-S-12883/41
-01 S300-A6A2 16-18-20
Loose terminals
Above/below
panel mounting
M300-D4A
/-L/-N/-B/-C
-04 S300-A6B3 20-22-24
-02 S301-B6A2 16-18-20 M 301-D4F/-K
-03 S301-C6A2 16-18-20 M 301-D4E/-J
MS - Number LEACH P/N Contacts to accomodate wire # Applicable for relays
MIL-S-12883/41B
-11 S300-A1A2 16-18-20
Loose terminals
below
panel mounting
M300-D4A
/-L/-N/-B/-C
-14 S300-A1B3 20-22-24
-12 S301-B1A2 16-18-20 M 301-D4F/-K
-13 S301-C1A2 16-18-20 M 301-D4E/-J
MS - Number LEACH P/N Contacts to accomodate wire # Applicable for relays
MIL-S-12883/41C
-11S S300-A8A8 16-18-20
Loose terminals
Above/below
panel mounting
M300-D4A
/-L/-N/-B/-C
-14S S300-A8B9 20-22-24
-12S S301-B8A8 16-18-20 M301-D4F/-K
-13S S301-C8A8 16-18-20 M301-D4F/-J
-15S S302-D8A8 16-18-20 M302-D4A/
-L/-N/-B/-C
MIL-S-12883/41C
-16S S300-A9A8 16-18-20
Fixed terminals
Above/below
panel mounting
M300-D4A
/-L/-N/-B/-C
-19S S300-A9B9 20-22-24
-17S S301-B9A8 16-18-20 M 301-D4F/-K
-18S S301-C9A8 16-18-20 M 301-D4E/-J
-20S S302-D9A8 16-18-20 M 302-D4A/
-L/-N/-B/-C
Date of issue: 3/06 - 20 - Page 4 of 4