Mounting
!"#$%&"'$"()*+',-%"./0'+'/$1
23)"40)*"03/4%5".*/+),+"3)-+"0)$0'+'()"6-+)*'-%0"-0"7)%%"-0".)*0/$0"-8-'$0+"-$&",/$+-,+0"7'+3"+3)
3)-+0'$9:";/*"$/$"()*+',-%"6/4$+'$8"<"+3)"%/-5",4**)$+"640+"=)">?@"%/7)*"+3-$"+3)"*-+)5"/$)":";/*"-
8//5",//%'$8<"+3)"AAB"$))50"-$" -'*" ,/$(),+'/$:" C)00" ,/$(),+'/$" -'*" .*/54,)0" -$"-=$/*6-%"3)-+'$8:
D))."-"5'0+-$,)"=)+7))$""+3)"4..)*"AAB"-$5"+3)"%/7)*"AAB:"E$",-0)"/F"$/"0.-,)"=)+7))$"+7/"AAB"
GH)*/"0.-,)"=)+7))$"+7/"AAB0I"<".%)-0)"*)54,)"+3)"%/-5",4**)$+:";/*"F4*+3)*"5)+-'%0"*)F)*"+/"=)%/7"1
!"J)*-+'$8",4**)$+"7'+3"$/"0.-,)"=)+7))$"AAB0
""AC-51 nominal currents are given with a space of 22,5mm between each SSR, for a
permanent current during a minimum time of 8 hours in air calm according to IEC60947-4-3. In case
of non permanent currents or in case of SSRs are mounted with no space, you must check the heatsink
temperature never exceed 90°C. When the SSRs are mounted side to side ( no space between each re-
lay) a derating current of 25% must be take into account.
A forced cooling ( fan inside the cabinet) improves significantly the thermal performances.
Typical application :
LOADS
SILD product is designed mainly for AC-51 résistive load. For other loads, check the inrush cur-
rent at turn ON and possible overvoltages at turn OFF or consult us :
* AC-55b : Incandescent lamps : Inrush current is generally 10 times In during few 10ms.
So limit the nominal current at about 15A.
Protection :
To protect the SSR against a short-circuit of the load , use a fuse with a I2t value = 1/2 I2t value
specified page 2. A test has been made with FERRAZ fuse ( see page 2).
It is possible to protect SSR by MCB ( miniature circuit breaker). In this case, see application note (
SSR protection) and use a SSR with high I2t value (5000A2s minimum).
EMC :
♦ Immunity :
We give in our data-sheets, the immunity level of our SSRs according to the main standards for
this type of products : EN61000-4-4 &5. You can see the high immunity level in comparison with the
products on the market.
♦ Emission:
SSRs are complex devices which must be interconnected with other equipment (loads, cables,etc.)
to form a system. Because the other equipment or the interconnections may not be under the control of
celduc, it shall be the responsibility of the system integrator to ensure that systems containing SSRs
comply with the requirements of any rules and regulations applicable at the system level.. Consult cel-
duc laboratory which can make some tests in your application.
S/CLP/SILD845160/E/28/05/2004
Connections .
♦ For the output terminals, the wire cross sections must be adapted
to the load current and to the overcurrent protection device
characteristics. The relay rated voltage must be adapted to the mains
rated voltage.
♦ celpac use screw clamp connections.
control
1 x(0,75-->2,5)
L = 6mm
Power
1x(1,5-->16) 1 x(1,5-->10)
L = 10mm
r e l a i s
www.celduc.com
5, Rue Ampère BP30004 42290 SORBIERS - FRANCE E-mail : celduc-relais@celduc.com
Fax +33 (0) 4 77 53 85 51 Service Commercial France Tél. : +33 (0) 4 77 53 90 20
Sales Dept.For Europe Tel. : +33 (0) 4 77 53 90 21 Sales Dept. Asia : Tél. +33 (0) 4 77 53 90 19
page 5 / 5F
celpac®