100F0111 Issue 9 27th May 2009 Specification Control Drawing Page 1 of 2 Page 2 is for internal use only WIRE, HALOGEN FREE, THIN WALL INSULATED, 250 VOLT AC IN ACCORDANCE WITH NF F 63-808, TEMPERATURE CLASSIFICATION 105C (Suitable for use at an operating voltage of 750/1300 VOLTS AC) Conductor Tin Plated Copper Insulation Halogen Free Polymer C8 Part NF F 63-808 Description Designation Nominal Nominal Cross Conductor Sectional Stranding Area No./Diam. (mm) (mm) C9 C14 C11 C16 C17 C18 Conductor Diameter (mm) Minimum Maximum Diameter Insulation Resistance Thickness (mm) Min. C21 C20 FINISHED WIRE @ 20C Nominal Maximum Base (mm) Lower Weight Weight Upper (kg/km) (kg/km) Colour (ohms/km) Spec Target Spec Max. Limit Limit #100F0111-22 N/A 0.38 19/0.16 0.74 0.76 0.20 50.5 1.26 1.29 1.34 4.46 4.63 * 100F0111-20 E 250 S 0.60-NF F 63-808 0.60 19/0.20 0.96 0.98 0.20 30.0 1.47 1.51 1.55 6.86 7.10 yellow 100F0111-18 E 250 S 0.93-NF F 63-808 0.93 19/0.25 1.21 1.24 0.20 20.0 1.70 1.75 1.80 10.5 10.8 white 100F0111-16 E 250 S 1.34-NF F 63-808 1.34 19/0.30 1.45 1.48 0.20 13.7 1.99 2.04 2.10 13.9 14.9 green 100F0111-14 E 250 S 1.82-NF F 63-808 1.82 37/0.25 1.68 1.72 0.20 9.80 2.30 2.36 2.45 19.8 20.7 yellow 100F0111-12 E 250 S 2.61-NF F 63-808 2.61 37/0.30 2.03 2.08 0.25 7.00 2.62 2.70 2.79 26.4 27.6 white 100F0111-10 E 250 S 4.32-NF F 63-808 4.32 61/0.30 2.53 2.90 0.25 4.46 3.29 3.38 3.51 43.8 47.0 green '#' This size is not covered by NF F 63-808 but except as stated, is tested to the requirements of NF F 63-808 Mai 1992. COLOUR CODE: Insulation colour determined by conductor cross sectional area, as defined above. '*' = Insulation colour determined by customer order. PERFORMANCE REQUIREMENTS: The complete requirements for procuring the wire described herein shall consist of this document and NF F 63-808 Mai 1992 except where indicated. MARKING: REQUIREMENT: Marking shall be vertically (longitudinally NF F Spec), spaced at 100 mm minimum to 150mm maximum, coloured black Legend: 'E $ - NF F 63-808 - TE Raychem - YY' Where: and "$" = the conductor cross sectional area (see above) "YY" = the Year Code Designator in accordance with the table below. e.g. 'E 0.93 - NF F 63-808 - TE Raychem - 09' reflects 100F0111-18 manufactured in 2009. N.B. When used as a component, the mark is defined by the cable SCD. 100F0111-22 only is marked as follows: 'E 0.38 - TE Raychem - YY' where "YY" = the Year Code Designator in accordance with the table above. APPROVAL: Electronic sign off - no signatures will appear. ''Raychem', 'TE' and 'Tyco Electronics' are registered trademarks of Tyco Electronics Corporation. (c)2009 Tyco Electronics Corporation. All International Rights Reserved.