1157
Related Information
FIBER
SENSORS
LASER
SENSORS
PHOTOELECTRIC
SENSORS
MICRO
PHOTOELECTRIC
SENSORS
AREA
SENSORS
SAFETY LIGHT
CURTAINS /
SAFETY COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
STATIC
CONTROL
DEVICES
LASER
MARKERS
PLC
HUMAN MACHINE
INTERFACES
ENERGY
MANAGEMENT
SOLUTIONS
FA COMPONENTS
MACHINE VISION
SYSTEMS
UV CURING
SYSTEMS
Selection
Guide
Static
Removers
Pulse Air-gun
Cleaning Box
Electrostatic
Sensor
ER-X
ER-TF
ER-VS02
ER-VW
ER-Q
ER-F
Head 1
Head 2
Airless
or Low-
Pressure
Fast
Charge
Removal
Area Ionizer Pulse AC Method
ER-X SERIES
High-Speed, Wide Area Charge Removal
General terms and conditions ............. F-3 Selection guide ........................... P.1155~
Glossary of terms.......................... P.1591 General precautions ..................... P.1595
panasonic.net/id/pidsx/global
"Fast Charge Removal", "Airless", "Low-Pressure". Three charge removal modes for diverse application coverage
The ER-X series offers an airless charge removal capability to eliminate the need for compressed air in addition to
low pressure and high speed compressed air based modes. Furthermore, it supports dual-head congurations for
expanded application coverage.
Massive ion discharge when using air
reduces charge removal time
By applying a compressed air source, the ion volume
increases providing an improved tact time for substrate
ionization. This makes the ER-X suitable for applications
such as electronic paper and thin lm solar cells, where
charge removal time is directly linked to productivity.
Prevents dust dispersion and cleanliness
degradation!
The ER-X series can effectively remove surface charges
with an air pressure of less than 0.05 MPa. With the
advantage of minimal dust dispersion, it is suitable
for charge removal in semiconductor, FPD (mobile
panel), and other applications that require high degree
of cleanliness. The presence of air also helps prevent
adhesion of dust to the discharge needles, requiring less
cleaning than in the airless charge removal mode.
Certified by
NRTL
Area Ionizer ER-X SERIES
1158
FIBER
SENSORS
LASER
SENSORS
PHOTOELECTRIC
SENSORS
MICRO
PHOTOELECTRIC
SENSORS
AREA
SENSORS
SAFETY LIGHT
CURTAINS /
SAFETY COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
STATIC
CONTROL
DEVICES
LASER
MARKERS
PLC
HUMAN MACHINE
INTERFACES
ENERGY
MANAGEMENT
SOLUTIONS
FA COMPONENTS
MACHINE VISION
SYSTEMS
UV CURING
SYSTEMS
Selection
Guide
Static
Removers
Pulse Air-gun
Cleaning Box
Electrostatic
Sensor
ER-X
ER-TF
ER-VS02
ER-VW
ER-Q
ER-F
Pulse AC method for faster charge removal
The ER-X series has adopted the pulse AC method
that alternately applies positive and negative voltages
to each discharge needle. This enables generation and
discharge of a large amount of ions, resulting in faster
charge removal. Select from eight pulse frequencies
according to your application, from 100 Hz for charge
removal on nearby or moving workpieces to 1 Hz for
charge removal on far-away workpieces or in a three-
dimensional space.
0 1 2 3 4
1,000
800
600
400
200
ER-X
Charge voltage (V)
Charge removal time (sec.)
Conventional model
Conventional model, with airflow, 0.05 MPa
ER-X032, airless
ER-X032, with airflow, 0.05 MPa
Measured at a charge removal distance of 100 mm 3.937 in using
a 150 × 150 mm 5.906 × 5.906 in CPM (at center of CPM).
Charge removal time characteristics (TYPICAL)
Automatic ion balance control
The ER-X series provides an automatic ion balance
control mechanism that senses the amount of ions being
generated (which changes according to environmental
factors) and compensate for this deviation in the
controller, thus maintaining a highly stable ion balance
as an original operator setting.
<Pulse AC method> Example of variable discharge
frequency/ion balance
Negative ion generation
Positive ion generation
Variable ion balance
Supports airless and low-pressure charge
removal, which means charge removal is
possible without blowing away tiny work pieces
Free head placement is possible thanks to
exible cable with internal air tube
Air supply port angle can be adjusted
ER-X001 high-voltage unit
Joint for ø6 mm ø0.236 in air tube
360°
angle adjustment
ER-X001
Effective charge removal width:
50 mm 1.969 in approx.
SPOT TYPE HEAD
0.3 sec. or less*1 fastest charge removal achieved
with pulse AC method spot type ionizer*2
The pulse AC method enables the ER-X001 to generate
and discharge a large amount of ions, which makes
charge removal faster. Furthermore, as a spot type
ionizer, it achieves the fastest charge removal of 0.3 sec.
or less*1 (±1,000 V → ±100 V).
*1: As of March 2016, in-company survey
*2: Spot diameter of ø15 mm ø0.591 in or less
1159
Area Ionizer ER-X SERIES
FIBER
SENSORS
LASER
SENSORS
PHOTOELECTRIC
SENSORS
MICRO
PHOTOELECTRIC
SENSORS
AREA
SENSORS
SAFETY LIGHT
CURTAINS /
SAFETY COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
STATIC
CONTROL
DEVICES
LASER
MARKERS
PLC
HUMAN MACHINE
INTERFACES
ENERGY
MANAGEMENT
SOLUTIONS
FA COMPONENTS
MACHINE VISION
SYSTEMS
UV CURING
SYSTEMS
Selection
Guide
Static
Removers
Pulse Air-gun
Cleaning Box
Electrostatic
Sensor
ER-X
ER-TF
ER-VS02
ER-VW
ER-Q
ER-F
Carefully designed to prevent
contamination in manufacturing processes
In consideration of the manufacturing process
(secondary cells etc.), the ER-X series heads neither
use copper nor plate processing. This minimizes the risk
of contamination with foreign substances.
Discharge needle air barrier design for reduced contamination
A barrier of clean air around the discharge needle keeps
foreign matter from adhering to it, preventing degraded
performance. Additionally, by using separate air sources
for the discharge needle barrier and ion transport, the
ER-X series keeps discharge from becoming unstable
due to pressure concentration, allowing the device to
efciently generate and transport ions.
Air barrier
structure
Efcient charge
removal structure
Discharge needle after
protected by air barrier
(0.05 MPa) for one month
Flat discharge surface for easy cleaning
The ER-X series heads have a at discharge face,
allowing effortless cleaning of the discharge needles and
air outlets by simply brushing along the groove provided.
Commercial brushGroove
Discharge needles
Air outlets
Discharge needle unit for simple needle replacement
The removable discharge needle unit (including a set
of four needles) substantially simplies maintenance.
To remove the unit, just slide it toward both ends as
indicated by the arrows.
Discharge needle unit
High and low temperature resistant type head also available
ER-X□HC
Bar type head compatible with ambient temperatures of
-60 to +200 °C -76 to +392 °F is available.
BAR TYPE HEAD
ER-X008
Effective charge removal width:
80 mm 3.150 in approx.
ER-X016
Effective charge removal width:
160 mm 6.299 in approx.
ER-X032
Effective charge removal width:
320 mm 12.598 in approx.
ER-X048
Effective charge removal width:
480 mm 18.898 in approx.
ER-X064
Effective charge removal width:
640 mm 25.197 in approx.
Super-compact slim head
By thoroughly redesigning the discharge needle, we
have created a super-compact slim head that combines
high-speed charge removal*1 with a maintenance-saving
design*2. The ER-X series can be embedded in, or
retrotted onto, equipment that did not provide enough
space for antistatic measures in the past.
*1: Pulse AC method with built-in air tubes (max. pressure 0.5 MPa)
*2: Discharge needle air barrier structure, discharge needle unit for
simple need replacement
360-
degree
angle
adjustment
360-
degree
angle
adjustment
30 mm30 mm
(1.181 in)
(1.181 in)
22 mm
22 mm
(0.866 in)
(0.866 in)
Angle adjustment screw
Area Ionizer ER-X SERIES
1160
FIBER
SENSORS
LASER
SENSORS
PHOTOELECTRIC
SENSORS
MICRO
PHOTOELECTRIC
SENSORS
AREA
SENSORS
SAFETY LIGHT
CURTAINS /
SAFETY COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
STATIC
CONTROL
DEVICES
LASER
MARKERS
PLC
HUMAN MACHINE
INTERFACES
ENERGY
MANAGEMENT
SOLUTIONS
FA COMPONENTS
MACHINE VISION
SYSTEMS
UV CURING
SYSTEMS
Selection
Guide
Static
Removers
Pulse Air-gun
Cleaning Box
Electrostatic
Sensor
ER-X
ER-TF
ER-VS02
ER-VW
ER-Q
ER-F
All-in-one model equipped with various
functions for optimal removal of charge
Discharge indicator (green)
Lights up during discharge.
CHECK indicator (orange)
Lights up when dirt, wear, etc. of the discharge
needle is detected.
ERROR indicator (red)
Lights up when abnormal discharge is detected.
Discharge frequency setting switch
Select from eight ion generation frequencies ranging from
100 Hz to 1 Hz according to your application.
Head 1 can be used as a charger when the discharge
frequency setting switch for Head 1 is set to+ Charge” or “-
Charge.
Notes: 1)
Head 2 performs the ordinary charge removal operation.
2) The ER-X001 cannot use the charging function.
(Discharge operation stops.)
Ion balance setting switch
Adjust the ion balance to any of 15 levels according
to the strength of the charge on the workpieces.
Various setting switch
Check level changeover switch
Set the maintenance notication level to
“standard” or “high-sensitivity.”
Ion balance control switch
Enable or disable the ion balance auto control function.
Indicator changeover switch
Set the level meter indicator display mode to “charge
strength display” or “ion generation volume display.”
2 heads control switch
Set the ion generation timing for the two heads to
“synchronize” or “inverse.”
Error output changeover switch
Set the error output condition to “generation of
abnormal discharge” or “generation of abnormal
discharge + discharge stop setting ON.”
Dual head conguration for enhanced charge area and layout expansion
Head 2
Head 1
High-voltage unit
High-voltage unit
Controller
Equipped with charging function
The charging function is useful when charging paper or
parts for static electricity adsorption transport.
Notes: 1) Head 2 performs the ordinary charge neutralizing operation.
2) The ER-X001 cannot use the charging function.
(Discharge operation stops.)
ER-XC02
CONTROLLER
Different heads can be combined.
* The new-type controller, ER-XC02, allows simultaneous connection of
the bar type head and spot type head.
• Charge removal is possible with a layout that places
heads on either side of the workpiece.
The charge removal efciency can be increased by
synchronizing the two heads.
1
controller + 2 heads
Level meter indicator (green)
Discharge control switch
SET UP button
Indicates static buildup around
the head or the amount of ion
generated from the head.
Turn ion generation on and off.
Determine the settings of
discharge frequency and ion
balance.
Discharge control input
Turn ion generation on and off
from an external device.
Alarm output, error output
Report maintenance timing and
malfunctions to an external device.
1161
Area Ionizer ER-X SERIES
FIBER
SENSORS
LASER
SENSORS
PHOTO-
ELECTRIC
SENSORS
MICRO
PHOTO-
ELECTRIC
SENSORS
AREA
SENSORS
SAFETY LIGHT
CURTAINS /
SAFETY
COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASURE-
MENT
SENSORS
STATIC
CONTROL
DEVICES
LASER
MARKERS
PLC
HUMAN
MACHINE
INTERFACES
ENERGY
MANAGEMENT
SOLUTIONS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
Selection
Guide
Static
Removers
Pulse
Air-gun
Cleaning
Box
Electrostatic
Sensor
ER-X
ER-TF
ER-VS02
ER-VW
ER-Q
ER-F
APPLICATIONS
Preventing electrostatic damage
during bonding
Removal of static charges on laminate lm
Charge removal and dust removal
while separating TAB protective lm
Removing dust during instrument
panel assembly
High-speed charge removal on a
taping machine
Prevention of part feeder clogging
Charge removal of molded plastic
components on a conveyor belt
Removing dust during food
product cup transport
Airless charge removal of minute components
on a conveyor belt
High-speed charge removal on FPCs
Charge removal and dust removal of
digital camera cases on a conveyor belt
Preventing adhesion of molded
parts to molds High and low
temperature
resistant type
ER-X□HC
Area Ionizer ER-X SERIES
1162
FIBER
SENSORS
LASER
SENSORS
PHOTO-
ELECTRIC
SENSORS
MICRO
PHOTO-
ELECTRIC
SENSORS
AREA
SENSORS
SAFETY LIGHT
CURTAINS /
SAFETY
COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASURE-
MENT
SENSORS
STATIC
CONTROL
DEVICES
LASER
MARKERS
PLC
HUMAN
MACHINE
INTERFACES
ENERGY
MANAGEMENT
SOLUTIONS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
Selection
Guide
Static
Removers
Pulse
Air-gun
Cleaning
Box
Electrostatic
Sensor
ER-X
ER-TF
ER-VS02
ER-VW
ER-Q
ER-F
ORDER GUIDE
Heads Head connection cable is not supplied with the head. Please order it separately.
Type Appearance Charge removal time
(±1,000 V→±100 V) Ion balance Effective charge
removal width Model No.
Spot type
0.3 sec. or less
(Note 1),
0.5 sec. or less
(Note 2)
±30 V or less
(Note 2, 3)
50 mm 1.969 in
approx.
ER-X001
(Note 4)
Bar
type
1 sec. or less
(Note 2)
80 mm 3.150 in
approx.
ER-X008
(Note 4)
High
and low
temperature
resistant
ER-X008HC
(Note 5)
160 mm 6.299 in
approx.
ER-X016
High
and low
temperature
resistant
ER-X016HC
(Note 5)
320 mm 12.598 in
approx.
ER-X032
High
and low
temperature
resistant
ER-X032HC
(Note 5)
480 mm 18.898 in
approx.
ER-X048
High
and low
temperature
resistant
ER-X048HC
(Note 5)
640mm 25.197 in
approx.
ER-X064
High
and low
temperature
resistant
ER-X064HC
(Note 5)
Notes: 1) Typical value in condition of discharge distance 50 mm 1.969 in, center of the product, discharge frequency 50 Hz and air supply 60 ℓ/min. (0.3 MPa).
2) Typical value in condition of discharge distance 100 mm 3.937 in (ER-X001: 50 mm 1.969 in), center of the product, discharge frequency 50 Hz
(ER-X□HC: 30 Hz) and no air supply.
3) Ion balance refers to the average value of plus and minus. The specication value is the typical one in condition used when ambient temperature
change is less than ±10 °C, ion balance is set after 30 minutes from the discharge start, the ion balance control function is set ON.
4) The ER-X001 and ER-X008 must be combined with the new-type ER-XC02 controller.
For the Identication of previous-type and new-type controllers and for the combination with the head, refer to p.1171.
5) The ER-X□HC high / low temperature resistant type head can be used under temperatures from -60 to +200 °C -76 to +392 °F. Be sure to use this head
in combination with the new-type controller, ER-XC02.
For the Identication of previous-type and new-type controllers and for the combination with the head, refer to p.1171.
1163
Area Ionizer ER-X SERIES
FIBER
SENSORS
LASER
SENSORS
PHOTO-
ELECTRIC
SENSORS
MICRO
PHOTO-
ELECTRIC
SENSORS
AREA
SENSORS
SAFETY LIGHT
CURTAINS /
SAFETY
COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASURE-
MENT
SENSORS
STATIC
CONTROL
DEVICES
LASER
MARKERS
PLC
HUMAN
MACHINE
INTERFACES
ENERGY
MANAGEMENT
SOLUTIONS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
Selection
Guide
Static
Removers
Pulse
Air-gun
Cleaning
Box
Electrostatic
Sensor
ER-X
ER-TF
ER-VS02
ER-VW
ER-Q
ER-F
Appearance Model No. Description
ER-XCCJ2H Length: 2 m 6.562 ft, Net weight: 120 g approx.
Cabtyre cable with
both connector
ER-XCCJ5H Length: 5 m 16.404 ft, Net weight: 290 g approx.
ER-XCCJ10H (Note) Length: 10 m 32.808 ft, Net weight: 560 g approx.
Note: Cannot be used with the high and low temperature resistant type head ER-X□HC.
ORDER GUIDE
Controller Please order power cable or AC adapter separately.
Head connection cables Head connection cable is not supplied with the head. Please order it separately.
Type Appearance Model No. Number of heads
connected Output
Standard
type
ER-XC02 Max. 2 units PhotoMOS relay
OPTIONS
Designation Model No. Description
Power cable
ER-XCC2 Length: 2 m 6.562 ft
Net weight: 80 g approx. 0.15 mm2 10-core cabtyre cable
with connector
Cable outer diameter: ø5.3 mm
ø0.209 in
ER-XCC5 Length: 5 m 16.404 ft
Net weight: 190 g approx.
AC adapter
ER-XAPS-EX
IN: 100-240 V AC, 50/60 Hz
OUT: 24 V DC, 1.5 A
Ambient temperature: 0 to +40 °C +32 to +104 °F
Cable length between connector and AC adaptor: 1.8 m 5.905 ft
Ground wire: 3.7 m 12.139 ft
AC cable: 1 pc., Cable length 1.8 m 5.906 ft, Rating 125 V AC (Note 1)
Wiring connector terminals: 6 pcs.
ER-XAPS
AC cable
CN-ACCN-C2 AC cable (conforming to CCC), Length: 2 m 6.562 ft
CN-ACKR-C2 AC cable (conforming to KTL), Length: 2 m 6.562 ft
Discharge
needle unit
ER-XANT For ER-X016/X032/X048/X064. (Note 2)
Unit with replacement tungsten needles: 1 pc.
ER-XANT1 For ER-X001.
Unit with replacement tungsten needles: 1 pc.
ER-XANT2 For ER-X008. (Note 2)
Unit with replacement tungsten needles: 1 pc.
ER-XANTHC For ER-X016HC/X032HC/X048HC/X064HC.
Unit with replacement tungsten needles: 1 pc.
ER-XANT2HC For ER-X008HC.
Unit with replacement tungsten needles: 1 pc.
Discharge part
protective cover ER-XACVR
For ER-X016/X032/X048/X064. (Note 2)
Enables to prevent electric shock by mounting to the heads.
2 pcs. per set. (Note 3)
Material: Polycarbonate, Weight: 20 g approx. (1 set)
* No effect on charge removal capacity of the heads by mounting a
discharge part protection cover
Notes: 1) Rating of the AC cable is 125 V AC. If the voltage used exceeds 125 V AC, prepare a proper cable
by yourself or purchase our optional cable CN-ACCN-C2 or CN-ACKR-C2. And, the AC cable is
not enclosed with ER-XAPS-EX.
2) Cannot be used with the high and low temperature resistanttype head ER-X□HC.
3) The number of set(s) you need depends on the head model No.
Model No. ER-X016 ER-X032 ER-X048 ER-X064
No. of set
(2 pcs per set) 1 set 2 sets 3 sets 4 sets
Discharge needle unit
ER-XANT
ER-XANTHC
Power cable
ER-XCC□
Discharge part protective cover
ER-XACVR
ER-XANT1
ER-XANT2
ER-XANT2HC
AC adapter
ER-XAPS
ER-XAPS-EX
Area Ionizer ER-X SERIES
1164
FIBER
SENSORS
LASER
SENSORS
PHOTO-
ELECTRIC
SENSORS
MICRO
PHOTO-
ELECTRIC
SENSORS
AREA
SENSORS
SAFETY LIGHT
CURTAINS /
SAFETY
COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASURE-
MENT
SENSORS
STATIC
CONTROL
DEVICES
LASER
MARKERS
PLC
HUMAN
MACHINE
INTERFACES
ENERGY
MANAGEMENT
SOLUTIONS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
Selection
Guide
Static
Removers
Pulse
Air-gun
Cleaning
Box
Electrostatic
Sensor
ER-X
ER-TF
ER-VS02
ER-VW
ER-Q
ER-F
Heads
Type Spot type Bar type
Item Model No. ER-X001 ER-X008 ER-X016 ER-X032 ER-X048 ER-X064
CE marking directive compliance
EMC Directive, RoHS Directive
Effective charge removal width
50 mm 1.969 in approx. 80 mm 3.150 in approx. 160 mm 6.299 in approx. 320 mm 12.598 in approx. 480 mm 18.898 in approx. 640 mm 25.197 in approx.
Charge removal time
(±1,000 V→±100 V)
0.3 sec. or less (Note 1),
0.5 sec. or less (Note 2)
1 sec. or less (Note 2)
Ion balance ±30 V or less (Note 2, 3)
Discharge method Pulse AC method
Discharge frequency 50 Hz / 20 Hz
50 Hz / 30 Hz / 20 Hz
/ 10 Hz / 5 Hz / 1 Hz
100 Hz / 70 Hz / 50 Hz / 30 Hz / 20 Hz / 10 Hz / 5 Hz / 1 Hz (Note 4)
Discharge output voltage ±7,000 V approx.
Ozone generation 0.01 ppm or less (Note 2)
Maximum air pressure 0.5 MPa
Applicable uid Air (dried clean air) (Note 5)
Operating altitude 2,000 m 6561.68 ft or less (Note 6)
Ambient temperature
0 to +50 °C +32 to +122 °F (ER-X001: 0 to +40 °C +32 to +104 °F) (No dew condensation allowed), Storage: -10 to +65 °C +14 to +149 °F
Ambient humidity 35 to 65 % RH, Storage: 35 to 85 % RH
Vibration resistance 10 to 55 Hz (ER-X001: 10 to 150 Hz) frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each
Shock resistance 100 m/s2 acceleration (10 G approx.), in X, Y and Z directions three times each
Enclosure grounding method Floating
Material
Main unit enclosure: PPS, Stainless steal (SUS), Head mounting bracket: Stainless steal (SUS), Discharge needle: PC, PPS, Tungsten (Note 7)
[ER-X001 – Main unit enclosure: Stainless steel (SUS), Head mounting bracket: Stainless steel (SUS), Discharge needle: PFA, Tungsten]
Length of high-voltage cable 1.2 m 3.937 ft 0.5 m 1.640 ft 0.5 m 1.640 ft (Note 4)
Net weight 370 g approx. 330 g approx. 410 g approx. 530 g approx. 650 g approx. 780 g approx.
Accessory Head mounting bracket (mounted at the factory)
Type High and low temperature resistant
Item Model No. ER-X008HC ER-X016HC ER-X032HC ER-X048HC ER-X064HC
CE marking directive compliance
EMC Directive, RoHS Directive
Effective charge removal width 80 mm 3.150 in approx.
160 mm 6.299 in approx. 320 mm 12.598 in approx. 480 mm 18.898 in approx. 640 mm 25.197 in approx.
Charge removal time
(±1,000 V→±100 V) 1 sec. or less (Note 2)
Ion balance ±30 V or less (Note 2, 3)
Discharge method Pulse AC method
Discharge frequency 30 Hz (Note 8)
Discharge output voltage ±7,000 V approx.
Ozone generation 0.01 ppm or less (Note 2)
Maximum air pressure 0.1 MPa
Applicable uid Air (dried clean air) (Note 5)
Operating altitude 2,000 m 6561.68 ft or less (Note 6)
Ambient temperature Head: -60 to +200 °C -76 to +392 °F (No dew condensation or icing allowed) (Note 9), Storage: -10 to +65 °C +14 to +149 °F
High voltage unit: 0 to +50 °C +32 to +122 °F (No dew condensation allowed), Storage: -10 to +65 °C +14 to +149 °F
Ambient humidity 35 to 65 % RH, Storage: 35 to 85 % RH
Vibration resistance 10 to 55 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each
Shock resistance 100 m/s2 acceleration (10 G approx.), in X, Y and Z directions three times each
Enclosure grounding method Floating
Material Main unit enclosure: PPS, Stainless steal (SUS), Head mounting bracket: Stainless steal (SUS),
Discharge needle: PC, PPS, Tungsten, Main unit enclosure of high-voltage unit: ABS
Length of high-voltage cable Heat-resistant shielded cable, 1.8 m 5.906 ft long
Net weight 420 g approx. 490 g approx. 620 g approx. 760 g approx. 900 g approx.
Accessories ø6 ø0.236-4 air tube joint: 1 pc., Seal cap: 1 pc., Head mounting bracket (mounted at the factory)
Notes: 1) Typical value in condition of discharge distance 50 mm 1.969 in, center of the product, discharge frequency 50 Hz and air supply 60 ℓ/min.(0.3 MPa).
2)
Typical value in condition of discharge distance 100 mm 3.937 in (ER-X001: 50 mm 1.969 in), center of the product, discharge frequency 50 Hz (ER-X□HC: 30 Hz) and no air supply.
3) Ion balance refers to the average value of plus and minus. The specication value is the typical one in condition used when ambient temperature
change is less than ±10 °C, ion balance is set after 30 minutes from the discharge start, the ion balance control function is set ON.
4) The high-voltage cable is also available in lengths of 1 m 3.281 ft and 2 m 6.562 ft. The discharge frequency of 1 m 3.281 ft / 2 m 6.562 ft cables is 50 /
30 / 20 / 10 / 5 / 1 Hz. For details, please contact our sales ofce.
5) The dried clean air is the air dried (dew point: equivalent of -20 °C -4 °F) and ltered (mesh-size: equivalent of 0.01 μm).
6) Do not use or store in an environment that has been pressurized to an air pressure higher than the atmospheric pressure at 0 m.
7) Silicon needles (ER-X016S, ER-X032S and ER-XANS) are also available. For details, please contact our sales ofce.
8) Set the discharge frequency to 30 Hz. Do not use any other frequency.
9) Discoloration of the head may occur when used under high temperatures, but it does not affect the charge removal performance.
SPECIFICATIONS
1165
Area Ionizer ER-X SERIES
FIBER
SENSORS
LASER
SENSORS
PHOTO-
ELECTRIC
SENSORS
MICRO
PHOTO-
ELECTRIC
SENSORS
AREA
SENSORS
SAFETY LIGHT
CURTAINS /
SAFETY
COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASURE-
MENT
SENSORS
STATIC
CONTROL
DEVICES
LASER
MARKERS
PLC
HUMAN
MACHINE
INTERFACES
ENERGY
MANAGEMENT
SOLUTIONS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
Selection
Guide
Static
Removers
Pulse
Air-gun
Cleaning
Box
Electrostatic
Sensor
ER-X
ER-TF
ER-VS02
ER-VW
ER-Q
ER-F
SPECIFICATIONS
Type Controller
Item Model No. ER-XC02
CE marking directive compliance
EMC Directive, RoHS Directive
Number of heads connected Maximum 2 units
Supply voltage 24 V DC ±10 %
Current consumption 450 mA or less when connecting 1 head, 800 mA or less when connecting 2 heads
Indicator Displays status of Head 1 and 2
DSC (Discharge) Green LED (lights up when discharging)
CHECK Orange LED (lights up when dirt, wear, etc. of the discharge needle is detected)
ERROR Red LED (lights up when abnormal discharge is detected)
Level meter Green LED (5 levels, lights up depending on amount of the charge or ion generation)
Output
ALARM
ERROR
COM (Common)
PhotoMOS relay output
Maximum load current: 100 mA
Applied voltage: 30 V DC or less (between output-output common)
Residual voltage: 1.5 V or less (at 100 mA load current)
Output operation ALARM: ON when dirt or wear of the discharge needle is detected, OFF when operation is normal.
ERROR: OFF when abnormal discharge is detected, ON when operation is normal.
Short-circuit protection
Incorporated (automatic reset type)
Discharge control input (DSC OFF)
Discharge allowed: Open, Discharge halt: 24 V or 0 V shorted
Contamination level 2
Overvoltage category I
Elevation 2,000 m 6561.68 ft or less (Note)
Ambient temperature 0 to +50 °C +32 to +122 °F (No dew condensation allowed), Storage: –10 to +65 °C +14 to +149 °F
Ambient humidity 35 to 65 % RH, Storage: 35 to 85 % RH
Voltage withstandability 1,000 V AC for one min. between all supply terminals connected together and enclosure
500 V AC for on min. between supply terminals and F.G.
Insulation resistance 20 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure
Vibration resistance 10 to 150 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each
Shock resistance 100 m/s2 acceleration (10 G approx.) in X, Y and Z directions three times each
Enclosure grounding method Floating
Material Enclosure: ABS
Weight Net weight: 130 g approx.
Accessories Power supply / I/O connector: 1 set (Housing 5557-10R, Terminal 5556TL [manufactured by Molex])
Ground wire (3.7 m 12.139 ft approx.): 1 pc.
Note: Do not use or store in an environment that has been pressurized to an air pressure higher than the atmospheric pressure at 0 m.
Controller
Allowable ambient temperature of high and low temperature resistant type head ER-X□HC and its installation
When installing, make sure to expose a section measuring 500 mm 19.685 in or more to the normal temperature area as
shown below for the protection of the high-voltage unit.
Note: The high and low temperature resistant type ER-X□HC cannot be connected with the ER-XCCJ10H head connection cable (10 m 32.808 ft in length).
Allowable ambient temperature of the head
-60 to +200 °C -76 to +392 °F
Allowable ambient temperature of the high-voltage unit
0 to +50 °C +32 to +122 °F
Head connection cable (Note)
500 mm
19.685 in
or more
Head
High-voltage cable (1.8 m 5.906 ft)
High-voltage unit
Area Ionizer ER-X SERIES
1166
FIBER
SENSORS
LASER
SENSORS
PHOTO-
ELECTRIC
SENSORS
MICRO
PHOTO-
ELECTRIC
SENSORS
AREA
SENSORS
SAFETY LIGHT
CURTAINS /
SAFETY
COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASURE-
MENT
SENSORS
STATIC
CONTROL
DEVICES
LASER
MARKERS
PLC
HUMAN
MACHINE
INTERFACES
ENERGY
MANAGEMENT
SOLUTIONS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
Selection
Guide
Static
Removers
Pulse
Air-gun
Cleaning
Box
Electrostatic
Sensor
ER-X
ER-TF
ER-VS02
ER-VW
ER-Q
ER-F
CHARGE REMOVAL CHARACTERISTICS (TYPICAL)
Measured using a 150 × 150 mm 5.906 × 5.906 in CPM (charge plate monitor). (At center of CPM)
Please contact our ofce for details on data that is not listed here.
Correlation between charge removal
distance and charge removal time (10 Hz)
L
CPM
Center
0
6
8
4
2
10
Charge removal time (sec.)
1,000
39.370
800
31.496
200
7.874
400
15.748
600
23.622
Charge removal distance L (mm in)
Airless
0.005 MPa
0.1 MPa
0.3 MPa
0.5 MPa
Correlation between charge removal
distance and charge removal time (50 Hz)
0
1,000
39.370
800
31.496
200
7.874
400
15.748
600
23.622
6
8
4
2
10
L
CPM
Center
Charge removal distance L (mm in)
Charge removal time (sec.)
Airless
0.005 MPa
0.1 MPa
0.3 MPa
0.5 MPa
ER-X008
Charge removal eld
(vertical direction, airless, 10 Hz)
LW
CPM
Center +
0
100
3.937
100
3.937
300
11.811
200
7.874
200
7.874
300
11.811
Charge removal width W (mm in)
250
9.843
300
11.811
200
7.874
50
1.969
100
3.937
150
5.906
0
Charge removal distance L (mm in)
1 sec.
2 sec.
5 sec.
10 sec.
Charge removal eld
(vertical direction, airless, 50 Hz)
0
100
3.937
100
3.937
300
11.811
200
7.874
200
7.874
300
11.811
250
9.843
300
11.811
200
7.874
50
1.969
100
3.937
150
5.906
0
LW
CPM
Center +
Charge removal width W (mm in)
Charge removal distance L (mm in)
1 sec.
2 sec.
5 sec.
10 sec.
Air ow
0 0.1 0.2 0.3 0.4 0.5
Applied pressure (MPa)
Air flow [ℓ/min. (ANR)]
20
40
60
80
100
ER-X001
ER-X008
Correlation between charge removal
distance and charge removal time (20 Hz)
L
CPM
Center
0
200
7.874
400
15.748
600
23.622
800
31.496
1,000
39.370
Charge removal distance L (mm in)
Charge removal time (sec.)
2
4
6
8
10
Airless
0.005 MPa
0.1 MPa
0.3 MPa
0.5 MPa
Correlation between charge removal
distance and charge removal time (50 Hz)
Airless
0.005 MPa
0.1 MPa
0.3 MPa
0.5 MPa
0
200
7.874
400
15.748
600
23.622
800
31.496
1,000
39.370
Charge removal distance L (mm in)
Charge removal time (sec.)
2
4
6
8
10
L
CPM
Center
Common to ER-X001/X008
ER-X001
Charge removal eld
(airless, 50 Hz)
250
9.843
200
7.874
50
1.969
100
3.937
150
5.906
0
0
100
3.937
50
1.969
150
5.906
50
1.969
100
3.937
250
9.843
150
5.906
200
7.874
200
7.874
250
9.843
L
CPM
Center
W
+
Charge removal width W (mm in)
Charge removal distance L (mm in)
1 sec.
2 sec.
5 sec.
10 sec.
Charge removal eld
(0.005 MPa, 20 Hz)
1 sec.
2 sec.
5 sec.
10 sec.
L
CPM
Center
W
+
0
100
3.937
50
1.969
150
5.906
50
1.969
100
3.937
250
9.843
150
5.906
200
7.874
200
7.874
250
9.843
Charge removal width W (mm in)
350
13.780
200
7.874
300
11.811
250
9.843
50
1.969
100
3.937
150
5.906
0
Charge removal distance L (mm in)
Charge removal eld
(0.005 MPa, 50 Hz)
350
13.780
200
7.874
300
11.811
250
9.843
50
1.969
100
3.937
150
5.906
0
0
100
3.937
50
1.969
150
5.906
50
1.969
100
3.937
250
9.843
150
5.906
200
7.874
200
7.874
250
9.843
Charge removal width W (mm in)
Charge removal distance L (mm in)
L
CPM
Center
W
+
1 sec.
2 sec.
5 sec.
10 sec.
Charge removal eld
(airless, 20 Hz)
0
100
3.937
50
1.969
150
5.906
50
1.969
100
3.937
250
9.843
150
5.906
200
7.874
200
7.874
250
9.843
Charge removal width W (mm in)
250
9.843
200
7.874
50
1.969
100
3.937
150
5.906
0
Charge removal distance L (mm in)
L
CPM
Center
W
+
1 sec.
2 sec.
5 sec.
10 sec.
ER-X001
Charge removal eld
(0.5 MPa, 50 Hz)
1,000
39.370
600
23.622
800
31.496
400
15.748
200
7.874
0
0.5 sec.
1 sec.
2 sec.
5 sec.
L
CPM
Center
W
+
0
100
3.937
50
1.969
150
5.906
50
1.969
100
3.937
250
9.843
150
5.906
200
7.874
200
7.874
250
9.843
Charge removal width W (mm in)
Charge removal distance L (mm in)
Charge removal eld
(0.5 MPa, 20 Hz)
0.5 sec.
1 sec.
2 sec.
5 sec.
0
100
3.937
50
1.969
150
5.906
50
1.969
100
3.937
250
9.843
150
5.906
200
7.874
200
7.874
250
9.843
Charge removal width W (mm in)
1,000
39.370
600
23.622
800
31.496
400
15.748
200
7.874
0
Charge removal distance L (mm in)
L
CPM
Center
W
+
ER-X001
1167
Area Ionizer ER-X SERIES
FIBER
SENSORS
LASER
SENSORS
PHOTO-
ELECTRIC
SENSORS
MICRO
PHOTO-
ELECTRIC
SENSORS
AREA
SENSORS
SAFETY LIGHT
CURTAINS /
SAFETY
COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASURE-
MENT
SENSORS
STATIC
CONTROL
DEVICES
LASER
MARKERS
PLC
HUMAN
MACHINE
INTERFACES
ENERGY
MANAGEMENT
SOLUTIONS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
Selection
Guide
Static
Removers
Pulse
Air-gun
Cleaning
Box
Electrostatic
Sensor
ER-X
ER-TF
ER-VS02
ER-VW
ER-Q
ER-F
CHARGE REMOVAL CHARACTERISTICS (TYPICAL)
Measured using a 150 × 150 mm 5.906 × 5.906 in CPM (charge plate monitor). (At center of CPM)
Please contact our ofce for details on data that is not listed here.
ER-X008
Common to ER-X016/X032/X048/X064
Air ow
0 0.1 0.2 0.3 0.4 0.5
ER-X064
ER-X048
ER-X032
ER-X016
400
300
200
100
Applied pressure (MPa)
Air flow [ℓ/min. (ANR)]
Charge removal eld
(horizontal direction, airless, 1 Hz)
0
200
7.874
100
3.937
300
11.811
100
3.937
200
7.874
500
19.685
300
11.811
400
15.748
400
15.748
500
19.685
Charge removal width W (mm in)
600
23.622
500
19.685
400
15.748
300
11.811
200
7.874
100
3.937
0
Charge removal distance L (mm in)
1 sec.
2 sec.
5 sec.
10 sec.
LW
CPM
Center +
Charge removal eld
(horizontal direction, airless, 10 Hz)
Charge removal eld
(horizontal direction, airless, 50 Hz)
0
200
7.874
100
3.937
300
11.811
100
3.937
200
7.874
500
19.685
300
11.811
400
15.748
400
15.748
500
19.685
Charge removal width W (mm in)
600
23.622
500
19.685
400
15.748
300
11.811
200
7.874
100
3.937
0
Charge removal distance L (mm in)
1 sec.
2 sec.
5 sec.
10 sec.
LW
CPM
Center +
600
23.622
500
19.685
400
15.748
300
11.811
200
7.874
100
3.937
0
LW
CPM
Center +
0
200
7.874
100
3.937
300
11.811
100
3.937
200
7.874
500
19.685
300
11.811
400
15.748
400
15.748
500
19.685
Charge removal width W (mm in)
Charge removal distance L (mm in)
1 sec.
2 sec.
5 sec.
10 sec.
Common to ER-X016/X032/X048/X064
Charge removal eld
(horizontal direction, 0.005 MPa, 1 Hz)
LW
CPM
Center
+
200
7.874
100
3.937
300
11.811
100
3.937
200
7.874
500
19.685
300
11.811
400
15.748
400
15.748
500
19.685
Charge removal width W (mm in)
0
0
1,000
39.370
800
31.496
600
23.622
400
15.748
200
7.874
Charge removal distance L (mm in)
1 sec.
2 sec.
5 sec.
10 sec.
Charge removal eld
(horizontal direction, 0.005 MPa, 10 Hz)
0
1,000
39.370
800
31.496
600
23.622
400
15.748
200
7.874
0
200
7.874
100
3.937
300
11.811
100
3.937
200
7.874
500
19.685
300
11.811
400
15.748
400
15.748
500
19.685
Charge removal width W (mm in)
Charge removal distance L (mm in)
1 sec.
2 sec.
5 sec.
10 sec.
LW
CPM
Center +
Charge removal eld
(horizontal direction, 0.005 MPa, 50 Hz)
0
1,000
800
31.496
600
23.622
400
15.748
200
7.874
0
200
7.874
100
3.937
300
11.811
100
3.937
200
7.874
500
19.685
300
11.811
400
15.748
400
15.748
19.685
1 sec.
2 sec.
5 sec.
10 sec.
LW
CPM
Center +
Common to ER-X016/X032/X048/X064
Charge removal eld
(horizontal direction, 0.5 MPa, 10 Hz)
1,600
62.992
1,400
55.118
1,200
47.244
1,000
39.370
800
31.496
600
23.622
400
15.748
200
7.874
0
200
7.874
100
3.937
300
11.811
100
3.937
200
7.874
500
19.685
300
11.811
400
15.748
400
15.748
500
19.685
Charge removal width W (mm in)
Charge removal distance L (mm in)
0
0.5 sec.
1 sec.
2 sec.
LW
CPM
Center +
Charge removal eld
(horizontal direction, 0.5 MPa, 50 Hz)
0.5 sec.
1 sec.
2 sec.
1,600
62.992
1,400
55.118
1,200
47.244
1,000
39.370
800
31.496
600
23.622
400
15.748
200
7.874
0
200
7.874
100
3.937
300
11.811
100
3.937
200
7.874
500
19.685
300
11.811
400
15.748
400
15.748
500
19.685
Charge removal width W (mm in)
0
Charge removal distance L (mm in)
LW
CPM
Center +
Correlation between charge removal
distance and charge removal time (1 Hz)
Correlation between charge removal
distance and charge removal time (10 Hz)
0
1,600
62.992
200
7.874
400
15.748
600
23.622
1,200
47.244
800
31.496
1,000
39.370
1,400
55.118
10
8
6
4
2
Charge removal distance L (mm in)
Charge removal time (sec.)
Airless
0.005 MPa
0.1 MPa
0.3 MPa
0.5 MPa
L
CPM
Center
0
1,600
62.992
200
7.874
400
15.748
600
23.622
1,200
47.244
800
31.496
1,000
39.370
1,400
55.118
10
8
6
4
2
Charge removal distance L (mm in)
Charge removal time (sec.)
Airless
0.005 MPa
0.1 MPa
0.3 MPa
0.5 MPa
L
CPM
Center
Correlation between charge removal
distance and charge removal time (50 Hz)
0
1,600
62.992
200
7.874
400
15.748
600
23.622
1,200
47.244
800
31.496
1,000
39.370
1,400
55.118
10
8
6
4
2
L
CPM
Center
Airless
0.005 MPa
0.1 MPa
0.3 MPa
0.5 MPa
Charge removal distance L (mm in)
Charge removal time (sec.)
Charge removal eld
(vertical direction, 0.005 MPa, 50 Hz)
0
100
3.937
100
3.937
300
11.811
200
7.874
200
7.874
300
11.811
Charge removal width W (mm in)
500
19.685
600
23.622
400
15.748
100
3.937
200
7.874
300
11.811
0
Charge removal distance L (mm in)
1 sec.
2 sec.
5 sec.
10 sec.
LW
CPM
Center +
Charge removal eld
(vertical direction, 0.5 MPa, 10 Hz)
LW
CPM
Center +
0
100
3.937
100
3.937
300
11.811
200
7.874
200
7.874
300
11.811
Charge removal width W (mm in)
1,000
39.370
800
31.496
200
7.874
400
15.748
Charge removal distance L (mm in)
600
23.622
0
1 sec.
2 sec.
5 sec.
10 sec.
Charge removal eld
(vertical direction, 0.5 MPa, 50 Hz)
1,000
39.370
800
31.496
200
7.874
400
15.748
Charge removal distance L (mm in)
600
23.622
0
LW
CPM
Center +
0
100
3.937
100
3.937
300
11.811
200
7.874
200
7.874
300
11.811
Charge removal width W (mm in)
1 sec.
2 sec.
5 sec.
10 sec.
Charge removal eld
(vertical direction, 0.005 MPa, 10 Hz)
0
100
3.937
100
3.937
300
11.811
200
7.874
200
7.874
300
11.811
Charge removal width W (mm in)
500
19.685
600
23.622
400
15.748
100
3.937
200
7.874
300
11.811
0
Charge removal distance L (mm in)
1 sec.
2 sec.
5 sec.
10 sec.
LW
CPM
Center +
Area Ionizer ER-X SERIES
1168
FIBER
SENSORS
LASER
SENSORS
PHOTO-
ELECTRIC
SENSORS
MICRO
PHOTO-
ELECTRIC
SENSORS
AREA
SENSORS
SAFETY LIGHT
CURTAINS /
SAFETY
COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASURE-
MENT
SENSORS
STATIC
CONTROL
DEVICES
LASER
MARKERS
PLC
HUMAN
MACHINE
INTERFACES
ENERGY
MANAGEMENT
SOLUTIONS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
Selection
Guide
Static
Removers
Pulse
Air-gun
Cleaning
Box
Electrostatic
Sensor
ER-X
ER-TF
ER-VS02
ER-VW
ER-Q
ER-F
CHARGE REMOVAL CHARACTERISTICS (TYPICAL)
Measured using a 150 × 150 mm 5.906 × 5.906 in CPM (charge plate monitor). (At center of CPM)
Please contact our ofce for details on data that is not listed here.
ER-X032
Charge removal eld
(vertical direction, 0.005 MPa, 10 Hz)
Charge removal eld
(vertical direction, 0.005 MPa, 1 Hz)
LW
CPM
Center +
0
1,000
39.370
800
31.496
600
23.622
400
15.748
200
7.874
200
7.874
100
3.937
300
11.811
100
3.937
200
7.874
500
19.685
300
11.811
400
15.748
400
15.748
500
19.685
Charge removal width W (mm in)
0
Charge removal distance L (mm in)
1 sec.
2 sec.
5 sec.
10 sec.
LW
CPM
Center +
0
1,000
39.370
800
31.496
600
23.622
400
15.748
200
7.874
200
7.874
100
3.937
300
11.811
100
3.937
200
7.874
500
19.685
300
11.811
400
15.748
400
15.748
500
19.685
Charge removal width W (mm in)
0
Charge removal distance L (mm in)
1 sec.
2 sec.
5 sec.
10 sec.
Charge removal eld
(vertical direction, 0.005 MPa, 50 Hz)
0
LW
CPM
Center +
1,000
39.370
800
31.496
600
23.622
400
15.748
200
7.874
200
7.874
100
3.937
300
11.811
100
3.937
200
7.874
500
19.685
300
11.811
400
15.748
400
15.748
500
19.685
Charge removal width W (mm in)
0
Charge removal distance L (mm in)
1 sec.
2 sec.
5 sec.
10 sec.
Charge removal eld
(vertical direction, 0.5 MPa, 1 Hz)
LW
CPM
Center +
1,600
62.992
1,400
55.118
1,200
47.244
1,000
39.370
800
31.496
600
23.622
400
15.748
200
7.874
0
200
7.874
100
3.937
300
11.811
100
3.937
200
7.874
500
19.685
300
11.811
400
15.748
400
15.748
500
19.685
Charge removal width W (mm in)
Charge removal distance L (mm in)
0
0.5 sec.
1 sec.
2 sec.
ER-X032 ER-X064
Charge removal eld
(vertical direction, 0.5 MPa, 10 Hz)
LW
CPM
Center +
1,600
62.992
1,400
55.118
1,200
47.244
1,000
39.370
800
31.496
600
23.622
400
15.748
200
7.874
0
200
7.874
100
3.937
300
11.811
100
3.937
200
7.874
500
19.685
300
11.811
400
15.748
400
15.748
500
19.685
Charge removal width W (mm in)
Charge removal distance L (mm in)
0
0.5 sec.
1 sec.
2 sec.
Charge removal eld
(vertical direction, 0.5 MPa, 50 Hz)
LW
CPM
Center +
1,600
62.992
1,400
55.118
1,200
47.244
1,000
39.370
800
31.496
600
23.622
400
15.748
200
7.874
0
200
7.874
100
3.937
300
11.811
100
3.937
200
7.874
500
19.685
300
11.811
400
15.748
400
15.748
500
19.685
Charge removal width W (mm in)
Charge removal distance L (mm in)
0
0.5 sec.
1 sec.
2 sec.
Charge removal eld
(vertical direction, airless, 10 Hz)
Charge removal eld
(vertical direction, airless, 1 Hz)
LW
CPM
Center +
600
23.622
300
11.811
400
15.748
200
7.874
500
19.685
100
3.937
0
Charge removal width W (mm in)
Charge removal distance L (mm in)
400
15.748
200
7.874
200
7.874
400
15.748
800
31.496
600
23.622
600
23.622
800
31.496
0
1 sec.
2 sec.
5 sec.
10 sec.
LW
CPM
Center +
600
23.622
300
11.811
400
15.748
200
7.874
500
19.685
100
3.937
0
Charge removal width W (mm in)
Charge removal distance L (mm in)
400
15.748
200
7.874
200
7.874
400
15.748
800
31.496
600
23.622
600
23.622
800
31.496
0
1 sec.
2 sec.
5 sec.
10 sec.
ER-X064
Charge removal eld
(vertical direction, airless, 50 Hz)
600
23.622
300
11.811
400
15.748
200
7.874
500
19.685
100
3.937
0
LW
CPM
Center +
Charge removal width W (mm in)
Charge removal distance L (mm in)
400
15.748
200
7.874
200
7.874
400
15.748
800
31.496
600
23.622
600
23.622
800
31.496
0
1 sec.
2 sec.
5 sec.
10 sec.
Charge removal eld
(vertical direction, 0.005 MPa, 1 Hz)
LW
CPM
Center +
0
1,000
39.370
800
31.496
600
23.622
400
15.748
200
7.874
Charge removal width W (mm in)
Charge removal distance L (mm in)
400
15.748
200
7.874
200
7.874
400
15.748
800
31.496
600
23.622
600
23.622
800
31.496
0
1 sec.
2 sec.
5 sec.
Charge removal eld
(vertical direction, 0.005 MPa, 10 Hz)
LW
CPM
Center +
0
1,000
39.370
800
31.496
600
23.622
400
15.748
200
7.874
Charge removal width W (mm in)
Charge removal distance L (mm in)
400
15.748
200
7.874
200
7.874
400
15.748
800
31.496
600
23.622
600
23.622
800
31.496
0
1 sec.
2 sec.
5 sec.
Charge removal eld
(vertical direction, 0.005 MPa, 50 Hz)
0
1 sec.
2 sec.
5 sec.
LW
CPM
Center +
1,000
39.370
800
31.496
600
23.622
400
15.748
200
7.874
Charge removal width W (mm in)
Charge removal distance L (mm in)
400
15.748
200
7.874
200
7.874
400
15.748
800
31.496
600
23.622
600
23.622
800
31.496
0
Charge removal eld
(horizontal direction, 0.5 MPa, 1 Hz)
LW
CPM
Center +
1,600
62.992
1,400
55.118
1,200
47.244
1,000
39.370
800
31.496
600
23.622
400
15.748
200
7.874
0
200
7.874
100
3.937
300
11.811
100
3.937
200
7.874
500
19.685
300
11.811
400
15.748
400
15.748
500
19.685
Charge removal width W (mm in)
Charge removal distance L (mm in)
0
0.5 sec.
1 sec.
2 sec.
Common to ER-X016/X032/X048/X064
Charge removal eld
(vertical direction, airless, 1 Hz)
LW
CPM
Center +
600
23.622
500
19.685
400
15.748
300
11.811
200
7.874
100
3.937
0
200
7.874
100
3.937
300
11.811
100
3.937
200
7.874
500
19.685
300
11.811
400
15.748
400
15.748
500
19.685
Charge removal width W (mm in)
Charge removal distance L (mm in)
0
1 sec.
2 sec.
5 sec.
10 sec.
Charge removal eld
(vertical direction, airless, 10 Hz)
Charge removal eld
(vertical direction, airless, 50 Hz)
600
23.622
500
19.685
400
15.748
300
11.811
200
7.874
100
3.937
0
200
7.874
100
3.937
300
11.811
100
3.937
200
7.874
500
19.685
300
11.811
400
15.748
400
15.748
500
19.685
Charge removal width W (mm in)
Charge removal distance L (mm in)
0
1 sec.
2 sec.
5 sec.
10 sec.
LW
CPM
Center +
600
23.622
500
19.685
400
15.748
300
11.811
200
7.874
100
3.937
0
LW
CPM
Center +
200
7.874
100
3.937
300
11.811
100
3.937
200
7.874
500
19.685
300
11.811
400
15.748
400
15.748
500
19.685
Charge removal width W (mm in)
0
Charge removal distance L (mm in)
1 sec.
2 sec.
5 sec.
10 sec.
ER-X032
1169
Area Ionizer ER-X SERIES
FIBER
SENSORS
LASER
SENSORS
PHOTO-
ELECTRIC
SENSORS
MICRO
PHOTO-
ELECTRIC
SENSORS
AREA
SENSORS
SAFETY LIGHT
CURTAINS /
SAFETY
COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASURE-
MENT
SENSORS
STATIC
CONTROL
DEVICES
LASER
MARKERS
PLC
HUMAN
MACHINE
INTERFACES
ENERGY
MANAGEMENT
SOLUTIONS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
Selection
Guide
Static
Removers
Pulse
Air-gun
Cleaning
Box
Electrostatic
Sensor
ER-X
ER-TF
ER-VS02
ER-VW
ER-Q
ER-F
CHARGE REMOVAL CHARACTERISTICS (TYPICAL)
Measured using a 150 × 150 mm 5.906 × 5.906 in CPM (charge plate monitor). (At center of CPM)
Please contact our ofce for details on data that is not listed here.
ER-X064
Charge removal eld
(vertical direction, 0.5 MPa, 10 Hz)
Charge removal eld
(vertical direction, 0.5 MPa, 1 Hz)
LW
CPM
Center +
0
1,600
62.992
800
31.496
1,000
39.370
400
15.748
600
23.622
200
7.874
1,400
55.118
1,200
47.244
Charge removal width W (mm in)
Charge removal distance L (mm in)
400
15.748
200
7.874
200
7.874
400
15.748
800
31.496
600
23.622
600
23.622
800
31.496
0
0.5 sec.
1 sec.
2 sec.
LW
CPM
Center +
0
1,600
62.992
800
31.496
1,000
39.370
400
15.748
600
23.622
200
7.874
1,400
55.118
1,200
47.244
Charge removal width W (mm in)
Charge removal distance L (mm in)
400
15.748
200
7.874
200
7.874
400
15.748
800
31.496
600
23.622
600
23.622
800
31.496
0
0.5 sec.
1 sec.
2 sec.
Charge removal eld
(vertical direction, 0.5 MPa, 50 Hz)
0
LW
CPM
Center +
1,600
62.992
800
31.496
1,000
39.370
400
15.748
600
23.622
200
7.874
1,400
55.118
1,200
47.244
Charge removal width W (mm in)
Charge removal distance L (mm in)
400
15.748
200
7.874
200
7.874
400
15.748
800
31.496
600
23.622
600
23.622
800
31.496
0
0.5 sec.
1 sec.
2 sec.
Correlation between charge removal
distance and charge removal time (30 Hz)
Airless
0.005 MPa
0.05 MPa
0.1 MPa
L
CPM
Center
0
200
7.874
400
15.748
600
23.622
800
31.496
1,000
39.370
Charge removal distance L (mm in)
Charge removal time (sec.)
2
4
6
8
10
Common to ER-X□HC ER-X008HC ER-X016HC
Air ow
0.06 0.080.02 0.04 0.1
ER-X064HC
ER-X048HC
ER-X032HC
ER-X016HC
ER-X008HC
0
Applied pressure (MPa)
Air flow [ℓ/min. (ANR)]
20
40
60
80
100
Correlation between charge removal
distance and charge removal time (30 Hz)
Airless
0.005 MPa
0.05 MPa
0.1 MPa
L
CPM
Center
0
200
7.874
400
15.748
600
23.622
800
31.496
1,000
39.370
Charge removal distance L (mm in)
Charge removal time (sec.)
2
4
6
8
10
Please contact our ofce for details on data that is not listed here.
Area Ionizer ER-X SERIES
1170
FIBER
SENSORS
LASER
SENSORS
PHOTO-
ELECTRIC
SENSORS
MICRO
PHOTO-
ELECTRIC
SENSORS
AREA
SENSORS
SAFETY LIGHT
CURTAINS /
SAFETY
COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASURE-
MENT
SENSORS
STATIC
CONTROL
DEVICES
LASER
MARKERS
PLC
HUMAN
MACHINE
INTERFACES
ENERGY
MANAGEMENT
SOLUTIONS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
Selection
Guide
Static
Removers
Pulse
Air-gun
Cleaning
Box
Electrostatic
Sensor
ER-X
ER-TF
ER-VS02
ER-VW
ER-Q
ER-F
Notes: 1) Be sure to ground the F.G. terminal. If F.G. terminal is not connected properly, it may cause electric shock.
2) To stop discharge, turn ON the discharge control input for 20 ms or longer. To start discharge, turn OFF
(open) the discharge control input. Discharge will start in 20 ms.
*2
Non-voltage contact or
NPN open-collector transistor
or
Contact “closed” or transistor ON: Discharge halt
Contact “open” or transistor OFF: Starting discharge
*1
Non-voltage contact or
PNP open-collector transistor
or
Contact “closed” or transistor ON: Discharge halt
Contact “open” or transistor OFF: Starting discharge
I/O CIRCUIT AND WIRING DIAGRAMS
Housing: 5569-10A
[Manufactured by Molex]
1 2 3 4 5
6 7 8 9 10
(Front view)
Power connector terminal arrangement
When connecting the output to negative common
(Brown) +V
COM(+)
(Violet) COM (OUT)
(Orange) Alarm output
(Black) Error output
(Pink) Discharge control input
(Blue) 0 V
COM(─)
(Green/Yellow) F.G.
User’s circuitInternal circuit
24 V DC
±10 %
*1
+
Be sure to ground.
Main circuit
Load
Load
6
7
4
9
10
3
1
2
5
When connecting the output to positive common
COM(+)
(Violet) COM (OUT)
(Orange) Alarm output
(Black) Error output
(Pink) Discharge control input
(Blue) 0 V
COM(─)
(Green/Yellow) F.G.
Be sure to ground.
Load
Load
Main circuit
6
7
3
9
10
4
1
2
5
*2
User’s circuitInternal circuit
(Brown) +V
24 V DC
±10 %
+
New-type controller (produced from April 2014 on)
Previous-type controller (produced before March 2014)
Notice:
Products manufactured from April 2014 and before April 2016 cannot be used with the high and low temperature resistant type head ER-X008HC.
For the Identication of previous-type and new-type controllers and for the combination with the head, refer to p.1171.
Notice: Products manufactured before March 2014 cannot be used with ER-X001, ER-X008 and the high and low temperature resistant type
head ER-X□HC.
For the Identication of previous-type and new-type controllers and for the combination with the head, refer to p.1171.
COM(+)
(White) COM (IN)
(Violet) COM (OUT)
(Orange) Alarm output
(Black) Error output
(Pink) Discharge control input
(Blue) 0 V
COM(─)
Be sure to ground.
Load
Load
Main circuit
6
7
3
8
9
10
4
1
2
5
*2
(Brown) +V
24 V DC
±10 %
+
User’s circuitInternal circuit
(Green/Yellow) F.G.
Terminal
No.
Terminal
name
Color
code
1 0 V Blue
2COM(–)
3Discharge
control input Pink
4COM(OUT) Violet
5 F.G. terminal
Green / Yellow
6 24 V Brown
7COM(+)
8COM(IN) White
9 Alarm output Orange
10 Error output Black
Note: Color code refers to cable colors
of an optional power supply
cable.
Terminal
No.
Terminal
name
Color
code
1 0 V Blue
2COM(–)
3Discharge
control input Pink
4COM(OUT) Violet
5 F.G. terminal
Green / Yellow
6 24 V Brown
7COM(+)
8 White
9 Alarm output Orange
10 Error output Black
Note: Color code refers to cable colors
of an optional power supply
cable.
Housing: 5569-10A
[Manufactured by Molex]
1 2 3 4 5
6 7 8 9 10
(Front view)
When connecting the output to positive common
Power connector terminal arrangement
When connecting the output to negative common
(Brown) +V
COM(+)
(Violet) COM (OUT)
(White) COM (IN)
(Orange) Alarm output
(Black) Error output
(Pink) Discharge control input
(Blue) 0 V
COM(─)
24 V DC
±10 %
*1
+
Be sure to ground.
Main circuit
Load
Load
6
7
4
9
8
10
3
1
2
5
User’s circuitInternal circuit
(Green/Yellow) F.G.
Notes: 1) Be sure to ground the F.G. terminal. If F.G. terminal is not connected properly, it may cause electric shock.
In the case of ER-X001, the head mounting bracket and F.G. terminal are internally connected.
2) To stop discharge, turn ON the discharge control input for 20 ms or longer. To start discharge, turn OFF
(open) the discharge control input. Discharge will start in 20 ms.
*2
Non-voltage contact or
NPN open-collector transistor
or
Contact “closed” or transistor ON: Discharge halt
Contact “open” or transistor OFF: Starting discharge
*1
Non-voltage contact or
PNP open-collector transistor
or
Contact “closed” or transistor ON: Discharge halt
Contact “open” or transistor OFF: Starting discharge
1171
Area Ionizer ER-X SERIES
FIBER
SENSORS
LASER
SENSORS
PHOTO-
ELECTRIC
SENSORS
MICRO
PHOTO-
ELECTRIC
SENSORS
AREA
SENSORS
SAFETY LIGHT
CURTAINS /
SAFETY
COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASURE-
MENT
SENSORS
STATIC
CONTROL
DEVICES
LASER
MARKERS
PLC
HUMAN
MACHINE
INTERFACES
ENERGY
MANAGEMENT
SOLUTIONS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
Selection
Guide
Static
Removers
Pulse
Air-gun
Cleaning
Box
Electrostatic
Sensor
ER-X
ER-TF
ER-VS02
ER-VW
ER-Q
ER-F
PRECAUTIONS FOR PROPER USE
Never use this product as device for personnel protection.
In case of using devices for personnel protection, use
products which meet laws or standards, such as OSHA,
ANSI or IEC etc., for personnel protection applicable in
each region or country.
This product produces high voltages.
Do not use this product in places where there may be a
danger of ammable or combustible items being present.
To prevent electric shock and to conduct proper
discharge, be sure to ground a frame ground (F.G.)
terminal of a controller.
Do not place hands near the discharge needle. Doing so
may cause electric shock.
Since the tip of the discharge needle is sharp, take
sufcient care in handling the discharge needle, or
injuries may result.
The high-voltage cable between the head and the high-
voltage unit must be xed and the minimum bend radius
is less than R30 mm R1.181 in. In case of using at the
bend radius R30 mm R1.181 in or less and using at
moving part may cause re and break down, etc. of the
high-voltage cable.
Clean the discharge needle regularly (about once a
week). Otherwise, optimum charge removal performance
may not be achieved, and accidents or operating
problems may occur.
If this product is used in a conned space, ozone emitted
from this product may be detrimental. Be sure to provide
ventilation.
Do not direct ionized air toward the face. Ozone may
cause irritation to places such as the nose and throat.
When the product has been used under very high or low
temperatures, do not touch the product with a bare hand.
Failure to observe this caution can result in burn or injury.
Be sure to let the product cool sufciently when touching
the product for maintenance or other purposes.
When using as a CSA and UL compliant product, use a CLASS 2 CSA/
UL certied power supply, or a CSA/UL certied power supply that
has been evaluated as a Limited Power Source as specied in CAN/
CSA-C22.2 No.60950-1/UL60950-1.
This product has been developed / produced for industrial use only.
Do not use this product for purposes other than electric charge removal.
Do not use this product in environments which are outside the
specication range, otherwise operating problems or damage may occur.
In addition, the operating life of the product may become signicantly
reduced.
This product is a precision device. Do not apply a shock to it by dropping,
for example. Accidents or operating problems may occur.
Never disassemble, repair or modify this product. Accidents or operating
problems may occur.
Do not throw this product in re. It may explode or toxic fumes may be
generated.
Do not run the wires together with high-voltage lines or power lines or put
them in the same raceway. This can cause malfunction due to induction.
Verify that the supply voltage variation is within the rating.
In case using switching regulator, be sure to connect F.G. terminal.
When connecting / removing the head or performing wiring or inspection
work, be sure to turn off the power rst. Not doing so may result in
accidents, electric shock or operating problems.
After connecting the cables, check that the connections are correct before
turning on the power. If the cables are connected incorrectly, operating
problems or accidents may occur.
Do not use a cable with any damage such as cracks or splitting. Risk of
accidents and failure.
Avoid use in a location with signicant steam or dust, or in a location
where the product may come in direct contact with water, oil, or welding
spatter.
Do not touch the discharge needle with hard objects such as tools. If the
discharge needle becomes broken, it will not provide sufcient charge
removal performance, and moreover operating problems or accidents
may occur.
During installation, fasten the product securely. If it is not securely
fastened or it is subjected to continuous vibration or shock, accidents or
operating problems may result.
Power cable that are 0.15mm
2
or more and 30 m 98.425 ft or less in total
length for wiring. Also, keep the wiring as short as possible in order to
prevent noise.
When disposing of this product, treat it appropriately as industrial waste.
After starting discharge, it takes 30 minutes approx. for charge removal
performance to stabilize. Therefore, wait 30 minutes before adjusting ion
balance.
Use the correct combination of head, discharge needle unit and controller.
Identication of previous-type and new-type controllers and combination with the head
Combination
New-type controller (Note)
Previous-type controller (Note)
Produced from April
2016 on
Produced from April 2014
and before April 2016
Produced before March 2014
• Front nameplate
DSC
ER-XC02
CHECK
ERROR
HEAD
1
HEAD
2
++
00
Change
of front
nameplate
design
• Front nameplate
DSC
ER-XC02
CHECK
ERROR
HEAD
1
HEAD
2
++
00
mark indicated
• Bottom nameplate • Bottom nameplate
mark not indicated
• Bottom nameplate
mark not indicated
Head
Spot type ER-X001 OK OK Cannot be used
Bar type
ER-X008
OK OK
Cannot be used
ER-X016
OK
ER-X032
ER-X048
ER-X064
High and Low
temperature
resistant
ER-X008HC
OK
Cannot be used
Cannot be used
ER-X016HC
OK
ER-X032HC
ER-X048HC
ER-X064HC
Note: The layout of the power supply connector pins differ between new-type controllers and previous-type controllers.
For details refer to I/O CIRCUIT AND WIRING DIAGRAMS (p.1170).
NRTL (National Recognized Testing Laboratories) certication means
that the product was tested by the third-party private testing organization
(TÜV SÜD America) authorized by the Occupational Safety and Health
Administration (OSHA) and found to comply with the safety standards
(ANSI/UL) established by American National Standards Institute and the
standards (CAN/CSA) established by Canadian Standards Association.
Front
nameplate
Bottom nameplate
Refer to p.1595 for general precautions.
Area Ionizer ER-X SERIES
1172
FIBER
SENSORS
LASER
SENSORS
PHOTO-
ELECTRIC
SENSORS
MICRO
PHOTO-
ELECTRIC
SENSORS
AREA
SENSORS
SAFETY LIGHT
CURTAINS /
SAFETY
COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASURE-
MENT
SENSORS
STATIC
CONTROL
DEVICES
LASER
MARKERS
PLC
HUMAN
MACHINE
INTERFACES
ENERGY
MANAGEMENT
SOLUTIONS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
Selection
Guide
Static
Removers
Pulse
Air-gun
Cleaning
Box
Electrostatic
Sensor
ER-X
ER-TF
ER-VS02
ER-VW
ER-Q
ER-F
Refer to p.1595 for general precautions.
PRECAUTIONS FOR PROPER USE
Notes: 1) Be sure to ground the equipment housing onto which the head is
mounted.
2) The distance between the head and the charge removing object
should be 30 mm 1.181 in or more.
If the static buildup of the charge removing object is 30 kV or more,
set the distance to 50 mm 1.969 in or more.
3) If there is metal near the head or between the head and the charge
removing object, ion is absorbed, hindering appropriate static
removal. Install the head under the following installation condition.
4) In case using the side mounting, the discharge frequency should
be 10 Hz or more.
5) When installing two or more heads set the same frequency and
keep the distance as below. In face to face or parallel using
different frequency, keep the distance between the heads 400 mm
15.748 in or more.
When installing the heads face to face, install heads in distance
that the heads can perform the charge removal of a side of the
object individualy.
Using two M4 screws or one M6 screw,
mount the head onto the equipment housing.
Loosen the angle adjustment screw,
adjust the head angle, and then fasten the
head with the tightening torque of 0.5 N∙m
or less.
Position the head mounting bracket of the
ER-X001 at least 20 mm 0.787 in away
from the tip of the head. The tightening
torque for the head xing screw must be
0.5 N∙m or less.
After mounting and setting up the head,
set the controller according to the procedures described in the
instruction manual in order to properly remove electrical charge.
Mounting
M6
screw
Angle
adjustment screw
M4
screw
Angle
adjustment screw
Surrounding
metal
Back-side mounting (All frequencies)
50 mm
1.969 in or more
Side mounting (10 Hz or more)
50 mm
1.969 in or more
Surrounding
metal
Mounting of ER-X001
20 mm
0.787 in
or more
20 mm
0.787 in
or more
The discharge
muzzle must
exceed this line
(surrounding metal.)
Head installation
Notes: 1) Do not place any objects on top of the
high-voltage unit.
2) When using multiple heads, keep the
distance of at least 10 mm 0.394 in
between the high-voltage units.
3) When fastening the high-voltage
unit using M6 screws, fasten before
connecting the head connection cable.
4) Use M6 screws for the installation of the high-voltage unit of the
ER-X001.
5) The minimum bending radius of the high-voltage cable is R30 mm
R1.181 in.
M4 screw
10 mm
0.394 in
or more
M6 screw
Use two M4 screws or two M6 screws
to fasten the head. The tightening
torques for fastening, are as follows.
When using M4 screws: 1.2 N∙m
When using M6 screws: 2.5 N∙m
High-voltage unit installation
Controller installation
<When mounting on a DIN rail>
Pull the lock release lever to
remove this product from the
DIN rail.
<When mounting using M4 screws>
The tightening torque should be
1.2 N∙m or less.
Mount the controller on a 35 mm 1.378 in width DIN rail or using
M4 screws.
35 mm 1.378 in
width DIN rail
Lock release lever
M4 screw
Air supplied to this product will reduce contamination of the
discharge needle and improve the charge removal speed.
The outer diameter of the air tube to t to the air inlet portion of
this product should be ø6 mm ø0.236 in.
Make sure that clean air (air containing no water, no oil and no
dust) should be supplied.
Since the pressure will drop when the air piping from the main
pressure supply is extended or pneumatic components (e.g.,
needle valve, speed controller, mini lter) are added, keep an
eye on the pressure supply to the ionizer making sure it is not in
short supply. For the pneumatic components, select those that
can accommodate the air supply ow rate.
Piping
Note: After inserting the tube into the joint of this product, always make sure
that the tube is all the way in and securely inserted. Insufcient tube
insertion will cause air leakage.
Air inlet
ø6 mm ø0.236 in tube
Head section
11.4 mm 0.449 in
ø6 ø0.236-4 air tube joint
Head section
ø6 mm ø0.236 in
heat-resistant tube
Insert all the way
• Face-to-face installation
• Parallel installation
ER-X008/X016/X032/X048/X064
ER-X008HC/X016HC/X032HC/X048HC/X064HC
ER-X001
<Connection of pipe to head section>
<Connection of pipe to head section>
<Connection to high-voltage unit>
M4 screw
Head
fixing
screw
100 mm
3.937 in
or more
100 mm
3.937 in
or more
50 mm 1.969 in
or more
50 mm
1.969 in
or more
(11.6 mm 0.457 in)
High-voltage unit
Air inlet
ø6 mm ø0.236 in tube
1173
Area Ionizer ER-X SERIES
FIBER
SENSORS
LASER
SENSORS
PHOTO-
ELECTRIC
SENSORS
MICRO
PHOTO-
ELECTRIC
SENSORS
AREA
SENSORS
SAFETY LIGHT
CURTAINS /
SAFETY
COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASURE-
MENT
SENSORS
STATIC
CONTROL
DEVICES
LASER
MARKERS
PLC
HUMAN
MACHINE
INTERFACES
ENERGY
MANAGEMENT
SOLUTIONS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
Selection
Guide
Static
Removers
Pulse
Air-gun
Cleaning
Box
Electrostatic
Sensor
ER-X
ER-TF
ER-VS02
ER-VW
ER-Q
ER-F
ER-X008/X016/X032/X048/X064 Head
ER-X008HC/X016HC/X032HC/X048HC/X064HC Head
Model No. A B C D (E)
ER-X008 40 1.575 106 4.173 138 5.433 150 5.906 163 6.417
ER-X016 120 4.724 194 7.638 226 8.898 238 9.370 251 9.882
ER-X032 280 11.024 354 13.937 386 15.197 398 15.669 411 16.181
ER-X048 440 17.323 514 20.236 546 21.496 558 21.969 571 22.480
ER-X064 600 23.622 674 26.535 706 27.795 718 28.268 731 28.780
Model No. A B C D (E)
ER-X008HC 40 1.575 106 4.173 138 5.433 150 5.906 163 6.417
ER-X016HC 120 4.724 194 7.638 226 8.898 238 9.370 251 9.882
ER-X032HC 280 11.024 354 13.937 386 15.197 398 15.669 411 16.181
ER-X048HC 440 17.323 514 20.236 546 21.496 558 21.969 571 22.480
ER-X064HC 600 23.622 674 26.535 706 27.795 718 28.268 731 28.780
Model No. (F)
ER-X016 159.6 6.283
ER-X032 319.6 12.583
ER-X048 479.6 18.882
ER-X064 639.6 25.181
6.2
0.244
22
0.866
18
0.709
ø6.9 ø0.272 high-voltage cable 0.5 m 1.640 ft
Joint for ø6 ø0.236 air tube
Clean air outlet (4 points)
28.5
1.122
9.4
0.370
A
40
1.575 40
1.575
9.4
0.370
B
28.5
1.122
Head mounting bracket
Head mounting bracket
Discharge needle unit
30 1.181
(E)
4.2
0.165
18
0.709
D
C
9.4
0.370
Points of discharge
needle ion air outlet
2-ø6.5
ø0.256
9.5 0.374
31
1.220
28 1.102
5
0.197
6
0.236
10.5
0.413
38
1.496
35
1.378
(25 0.984)
2-ø6.5 ø0.256
mounting holes
2-ø4.5 ø0.177
mounting holes
17
0.669
ø12
ø0.472
6
0.236
28.4
1.118
180 7.087
170 6.693
162 6.378
192 7.559
160 6.299
18
0.709
18
0.709
12-pin connector
DIMENSIONS (Unit: mm in)The CAD data can be downloaded from our website.
Mounting drawing with discharge part protective cover (ER-XACVR)
159.6 6.283
(160 6.299)
(F)
Discharge part protective cover
45.7
1.799
15.7 0.618
18
0.709
25.4
1.000
18
0.709
Note: The ER-XACVR discharge part protective cover cannot be used on the ER-X008 or high and low temperature resistant type head ER-X□HC.
Details of a head mounting bracket
4.2
0.165
9.4 0.370
6.2
0.244
2-ø6.5
ø0.256
18
0.709
Details of a head mounting bracket
4.2
0.165
9.4 0.370
6.2
0.244
2-ø6.5
ø0.256
18
0.709
6.2
0.244
Head mounting bracket
38
1.496
35
1.378
(25 0.984)
2-ø4.5 ø0.177
mounting holes
18
0.709
1300
51.181
Allowable ambient temperature: -60 to +200 °C -76 to +392 °F
28.4 1.118
30 1.181
6
0.236
192 7.559
162 6.378
170 6.693
10.5
0.413
Head mounting bracket
17
0.669
6
0.236
28.5
1.122
9.4
0.370
9.4
0.370
28.5
1.122
28 1.102
5
0.197
Clean air outlet (4 points)
ø6.9 ø0.272 heat-resistant
high-voltage cable (1.8 m 5.906 ft)ø6 ø0.236-4 air tube joint (accessory)
18
0.709
22
0.866
ø12
ø0.472
(E)
D
C
40
1.575
40
1.575
31
1.220
9.5 0.374
2-ø6.5 ø0.256
mounting holes
A
B
Points of discharge
needle ion air outlet
Discharge needle unit
180 7.087
160 6.299
4.2
0.165
18
0.709
9.4
0.370
2-ø6.5
ø0.256
12-pin connector
18
0.709
10
0.394
6.9
0.272
4
0.157
Area Ionizer ER-X SERIES
1174
FIBER
SENSORS
LASER
SENSORS
PHOTO-
ELECTRIC
SENSORS
MICRO
PHOTO-
ELECTRIC
SENSORS
AREA
SENSORS
SAFETY LIGHT
CURTAINS /
SAFETY
COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASURE-
MENT
SENSORS
STATIC
CONTROL
DEVICES
LASER
MARKERS
PLC
HUMAN
MACHINE
INTERFACES
ENERGY
MANAGEMENT
SOLUTIONS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
Selection
Guide
Static
Removers
Pulse
Air-gun
Cleaning
Box
Electrostatic
Sensor
ER-X
ER-TF
ER-VS02
ER-VW
ER-Q
ER-F
ER-XC02 Controller
ER-X001 Head
Power supply connection connector
5569-10A [Manufactured by Molex]
Head connection connector
S12B-PUDSS-1 [Manufactured by JST Mfg. Co., Ltd.]
9.2
0.362
5.2
0.205
10
0.394
2-ø5 ø0.197
mounting holes
7
0.276
6.5
0.256
4
0.157
35.4
1.394
27.3
1.075
For head 1
For head 2
44
1.732
18
0.709
39 1.535
53 2.087
7
0.276
76
2.992
97
3.189
60
2.362
Suitable for 35 mm 1.378 in width DIN rail
(103.5 4.075)
90
3.543
16
0.630
16
0.630
9.3
0.336
16.5
0.650
23.2
0.913
140
5.512
ER-XCCJ□H Head connection cable
(9.1 0.358)
L
9.1
0.358
8.8
0.346
8.8
0.346
14
0.551
14
0.551
ø6
ø0.236
Model No. Length L
ER-XCCJ2H 2,000
78.740
ER-XCCJ5H 5,000
196.850
ER-XCCJ10H
10,000
393.701
• Length L
ER-XCC□ Power cable (Optional)
19.6
0.772
14.4
0.567
22.2
0.874
ø5.3
ø0.209
L
Model No. Length L
ER-XCC2 2,000
78.740
ER-XCC5 5,000
196.850
• Length L
ER-XAPS(-EX)AC adapter (Optional)
(22.2
0.874)
(19.6 0.772)
Cable
1.8 m
5.910 ft
F.G. wire 3.7 m 12.139 ft
AC cable
1.8 m 5.910 ft (Note)
28
1.102
43.8
1.724
95.9
3.776
14.4
0.567
DIMENSIONS (Unit: mm in)The CAD data can be downloaded from our website.
2-6.5 0.256
mounting holes
20
0.787
38
1.496
35
1.378
18
0.709
25
0.984
6 0.236 210 8.268
(17 0.669)
6.2 0.244
20
0.787
16
0.630
8.6
0.339
(20.5 0.807)
12 0.472
4.2
0.165
28.5
1.122
ø10.5 ø0.413 high-voltage cable 1.2 m 3.937 ft long
(internal air tube)
M3 fixing screw
10.5
0.413
165 6.496
21.5
0.846 25.4
1.000
222 8.740
210
8.268
Joint for ø6 ø0.236 air tube
(360° rotatable)
70
2.756
44
1.732 24
0.945
ø13
ø0.512
ø12
ø0.472
ø17
ø0.669
6
0.236
Discharge
needle unit
Head mounting bracket
(removable) Ion air outlet
8
0.315
14
0.551
6
0.236
18 0.709
Mountable range
of head mounting
bracket
48
1.890
ø35
ø1.378
Note: The AC cable is not enclosed with ER-XAPS-EX.