2
SCD8661 Rev F 4/16/12 Aeroflex Plainview
ABSOLUTE MAXIMUM RATINGS
PARAMETER RANGE UNITS
Lead temperature (soldering 10 Sec) 300 °C
Input-Output Voltage Differential -30 VDC
ESD 2.000-3.999 1/KV
Operating Junction Temperature Range -55 to +150 °C
Storage Temperature Range -65 to +150 °C
1/ Meets ESD testing per MIL-STD-883, method 3015, Class 2
NOTICE: Stresses above those listed under "Absolute Maximum Ratings" may cause permanent damage to the device. These are stress rating only;
functional operation beyond the "Operation Conditions" is not recommended and extended exposure beyond the "Operation Conditions"
may effect device reliability.
RECOMMENDED OPERATING CONDITIONS
PARAMETER RANGE UNITS
Output Voltage Range -1.25 to -27 VDC
Case Operating Temperature Range -55 to +125 °C
ELECTRICAL PERFORMANCE CHARACTERISTICS
Unless otherwise specified -55°C < TC < +125°C & (VIN-VOUT) = -5V, IOUT = 0.5A
PARAMETER SYM CONDITIONS (P PMAX)MIN MAX UNITS
Reference Voltage 1/ 5/VREF -3V < (VIN - VOUT) < VDIFF MAX, 10mA < IOUT < IMAX -1.200 -1.300 V
Line Regulation 1/ 2/-3V < (VIN - VOUT) < -27V, - 0.05 %/V
Load Regulation 1/ 2/
10mA < IOUT < IMAX, VOUT < -5V - 50 mV
10mA < IOUT < IMAX, VOUT > -5V - 1.0 %
Thermal Regulation
IOUT = 1.5A, (VIN - VOUT) = -13.3V,
20ms Pulse, 20W, TC = +25°C
- 0.02 %/W
Ripple Rejection VOUT = -10V, f = 120Hz, CADJ = 10µF 66 - dB
Adjustment Pin Current 1/IADJ - 100 µA
Adjustment Pin Current 1/
Change IADJ
10mA < IOUT < IMAX
-5µA
-3V < (VIN - VOUT) < -27V
Minimum Load Current 1/ 3/
IMIN
(VIN - VOUT) = -27V - 5
mA
(VIN - VOUT) < -10V - 3
Current Limit 1/ 4/
IMAX
(VIN - VOUT) < -15V 1.5 -
A
(VIN - VOUT) = -27V, TC = +25°C 0.24 -
Long Term Stability 3/TA = +125°C - 1 %
Thermal Resistance
(Junction to Case) 3/JC -3°C/W
Notes:
1/ Specification derated to reflect Total Dose exposure to 100 Krad (Si) @25°C.
2/ Regulation is measured at a constant junction temperature, using pulse testing with a low duty cycle. Changes in output voltage due to heating
effects are covered under the specification for thermal regulation. Measurements taken at the output lead must be adjusted for lead resistance.
3/ Not tested. Shall be guaranteed to the specified limits.
4/ Pulsed @ <10% duty cycle @ 25°C.
5/ Testing over 12 watts is not performed over + 25°C.