SPECIFICATION
MODEL
DCVOLTAGE
RATEDCURRENT
CURRENTRANGE
RATEDPOWER (max.)
OUTPUT VOLTAGE ADJ.RANGE
LINEREGULATION
LOADREGULATION
SETUP,RISETIME
HOLDUP TIME (Typ.)
VOLTAGERANGE
FREQUENCY RANGE
POWERFACTOR (Typ.)
EFFICIENCY (Typ.)
INPUT
INRUSHCURRENT (Typ.)
LEAKAGECURRENT
SAFETY STANDARDS
HARMONICCURRENT
EMSIMMUNITY
WORKINGTEMP.
WORKINGHUMIDITY
STORAGETEMP.,HUMIDITY
TEMP.COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVERLOAD
OVERVOLTAGE
OVERTEMPERATURE(OPTION)
ACCURRENT (Typ.)
90~264VAC127~370VDC
47~63Hz
PF>0.95/230VACPF>0.98/115VACatfullload
76% 78% 78%
2.5A/115VAC1.2A/230VAC
COLDSTART 40A/230V
<3.5mA /240VAC
105~150% ratedoutputpower
CH1:5.75~6.75VCH2:3.8~4.4V CH1:5.75~6.75VCH2:13.8~16.2V
CH1:5.75~6.75VCH2:17.25~20.25V
Protectiontype: Shutdowno/pvoltage,re-powerontorecover
UL60950-1, TUVEN60950-1approved
-10~+60 (Refertooutputloadderatingcurve)
20~90%RHnon-condensing
-20~+85 ,10~95%RH
0.03%/ (0~50 )
10~500Hz,2G10min./1cycle,60min.eachalongX, Y,Zaxes
141.5Khrsmin.MIL-HDBK-217F(25 )
199*99*50mm(L*W*H)
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies.
(as available on http://www.meanwell.com)
CompliancetoEN55022(CISPR22)ClassB
Complianceto EN61000-3-2,-3
Complianceto EN55024,lightindustrylevel,criteria AEN61000-4-2,3,4,5,6,8,11;ENV50204,
RIPPLE&NOISE(max.) Note.2
VOLTAGETOLERANCE Note.3
ENVIRONMENT
SAFETY &
EMC
(Note4)
PROTECTION
WITHSTANDVOLTAGE
ISOLATIONRESISTANCE
I/P-O/P:3KVACI/P-FG:1.5KVACO/P-FG:0.5KVAC
I/P-O/P,I/P-FG,O/P-FG:100MOhms/500VDC /25 /70%RH
EMICONDUCTION&RADIATION
QP-150-3D QP-150D QP-150F
5V 3.3V 24V -12V 12V 24V -12V 15V 24V -15V
10A 10A 10A10A 2.5A 0.6A 4A 2A 0.6A 0.6A
3~15A 3~15A 3~15A0~15A 0.3~3A 0~1A 0~5A 0.4~3A 0~1A 0~5A 0.4~3A 0~1A
150.2W 150.2W 152W
100mVp-p 100mVp-p 150mVp-p 150mVp-p 150mVp-p 200mVp-p 150mVp-p 150mVp-p 200mVp-p 150mVp-p120mVp-p 120mVp-p
3.0% 3.0% 3.0% 3.0% 3.0% 3.0%6.0% 5.0% 6.0% 5.0% 5.0%
1.0%1.0%1.0% 2.0% 1.0% 1.0% 2.0% 1.0% 1.0%1.0% 2.0% 1.0%
2.0% 2.0% 2.0% 2.0% 2.0% 2.0% 2.0% 2.0%6.0% 2.0% 6.0% 6.0%
6.0%
Protectiontype:Shutdowno/pvoltage,recoversautomaticallyaftertemperaturegoesdown
FileName:QP-150-SPEC2010-10-18
150WQuadOutputwithPFCFunction QP-150 serie s
CH1:4.75~5.5VCH2:3.14~3.63V CH1:4.75~5.5VCH2:11.4~13.2V CH1:4.75~5.5VCH2:14.3~16.5V
Universal AC input / Full range
Built-in active PFC function, PF>0.95
Protections: Short circuit / Overload / Over voltage
Forced air cooling by built-in DC fan
CH4: Polarity is selectable
Fixed switching frequency at 100KHz
3 years warranty
Features:
800ms,50ms/230VAC 115VACatfullload800ms,50ms/
24ms/230VAC24 115VACatfullloadms/
Protectiontype:Hiccupmode,recoversautomaticallyafterfaultconditionisremoved
95 5 (TSW1)
0.93Kg;20pcs/19.6Kg/1.28CUFT
CH1 CH1 CH1
OUTPUTNUMBER CH2 CH2 CH2CH3 CH3 CH3CH4 CH4 CH4
..
5V 5V
3A 2A
http://store.iiic.cc/