Electrical Specifications: From –55°C to +85°C
1
Parameter Test Conditions Frequency Units Min Typ Max
Reference Insertion Loss — DC - 0.5 GHz
DC - 1.0 GHz
DC - 2.0 GHz
dB
dB
dB
—
—
—
—
—
—
2.0
2.3
2.5
Attenuation Accuracy
2
Any Single Bit
Any Combination of Bits
DC - 1.0 GHz
DC - 2.0 GHz
DC - 1.0 GHz
DC - 2.0 GHz
VSWR — DC - 2.0 GHz Ratio — — 1.6:1
Trise, Tfall 10% to 90% — ns — 12 —
Ton, Toff 50% Control to 90/10% RF — ns — 18 —
Transients In-Band (peak-peak) — mV — 25 —
1 dB Compression Input Power
Input Power
0.05 GHz
0.5 - 2.0 GHz
dBm
dBm
—
—
+20
+28
—
—
Input IP3 For two-tone Input Power
Up to +5 dBm
0.05 GHz
0.5 - 2.0 GHz
dBm
dBm
—
—
+40
+50
—
—
Input IP2 For two-tone Input Power
Up to +5 dBm
0.05 GHz
0.5 - 2.0 GHz
dBm
dBm
—
—
+45
+68
—
—
± (0.15 dB +3% of atten setting in dB) dB
± (0.2 dB +3% of atten setting in dB) dB
Or ± 0.45 dB, whichever is greater
± (0.22 dB +3% of atten setting in dB) dB
± (0.25 dB +4% of atten setting in dB) dB
Or ± 0.45 dB, whichever is greater
Input Leakage Current (Low) -0.2 to 0V — µA — — 20
Input Leakage Current (High) -8.0 to -5.0V — µA — — 200
1. All specifications apply when operated with control voltages of 0.0V to -5.0V.
2. This attenuator is guaranteed monotonic.
Absolute Maximum Ratings
3,4
Parameter Absolute Maximum
Max Input Power
0.05 GHz
0.5 - 2.0 GHz
+27 dBm
+34 dBm
Control Voltage
5
+0.5V, -8.5V
Operating Temperature -55°C to +125°C
Storage Temperature -65°C to +150°C
3. Exceeding any one or combination of these limits may
cause permanent damage to this device.
4. M/A-COM does not recommend sustained operation near
these survivability limits.
5. Standard CMOS TTL interface, latch-up will occur if logic
signal is applied prior to power supply.