82761 Paired - Single-Pair Cable For more information please call 1-800-Belden1 See Put-ups and Colors Description: 22 AWG stranded (7x30) TC conductors, plenum, FEP insulation, twisted pair, overall Beldfoil(R) shield (100% coverage), 22 AWG stranded TC drain wire, Flamarrest(R) jacket. PHYSICAL CHARACTERISTICS: CONDUCTOR: Number of Pairs 1 Total Number of Conductors 2 AWG 22 Stranding 7x30 Conductor Material TC - Tinned Copper INSULATION: Insulation Material FEP - Fluorinated Ethylene Propylene Nom. Insulation Wall Thickness .006 in. Pair Color Code Chart : Number 1 Color Black & Red OUTER SHIELD: Outer Shield Material Trade Name Beldfoil(R) (Z-Fold(R)) Outer Shield Type Tape Outer Shield Material Aluminum Foil-Polyester Tape Outer Shield %Coverage 100 % OUTER SHIELD DRAIN WIRE : Outer Shield Drain Wire AWG 22 Outer Shield Drain Wire Stranding Stranded Outer Shield Drain Wire Conductor Material TC - Tinned Copper OUTER JACKET: Outer Jacket Material Trade Name Flamarrest(R) Outer Jacket Material LS PVC - Low Smoke Polyvinyl Chloride Outer Jacket Nominal Wall Thickness .014 in. Page 1 of 3 82761 Paired - Single-Pair Cable OVERALL NOMINAL DIAMETER: Overall Nominal Diameter .116 in. MECHANICAL CHARACTERISTICS: Operating Temperature Range 0C To +75C Bulk Cable Weight 10.8 lbs/1000 ft. Max. Recommended Pulling Tension 27 lbs. Min. Bend Radius (Install) 1.2 in. APPLICABLE SPECIFICATIONS AND AGENCY COMPLIANCE: APPLICABLE STANDARDS: NEC/(UL) Specification CMP CEC/C(UL) Specification CMP EU CE Mark (Y/N) Yes EU RoHS Compliant (Y/N) Yes EU RoHS Compliance Date (mm/dd/yyyy): 04/01/2005 FLAME TEST: UL Flame Test NFPA 262 C(UL) Flame Test FT6 PLENUM/NON-PLENUM: Plenum (Y/N) Y Non-Plenum Number 8761 ELECTRICAL CHARACTERISTICS: Nom. Characteristic Impedance 42 Ohms Nom. Inductance .16 H/ft Nom. Capacitance Conductor to Conductor @ 1 KHz 35 pF/ft Nom. Cap. Cond. to Other Cond. & Shield @ 1 KHz 67 pF/ft Nom. Conductor DC Resistance @ 20 Deg. C 15 Ohms/1000 ft Nominal Outer Shield DC Resistance @ 20 Deg. C 12 Ohms/1000 ft Max. Operating Voltage - UL 300 V RMS Max. Recommended Current 2.8 Amps per conductor @ 25C PUT-UPS AND COLORS: Item Description 82761 8771000 1 PR #22 FEP FS FLMRST 82761 877U1000 1PR#22 FEP FS FLMRST Put-Up (ft.) 1000 Ship Weight (lbs.) 11 Jacket Color NATURAL U1000 13 NATURAL Page 2 of 3 Notes C 82761 Paired - Single-Pair Cable 82761 877U500 1PR#22 FEP FS FLMRST U500 7 NATURAL C = CRATE REEL PUT-UP. Revision Number: 1 Revision Date: 07-27-2005 (c) 2005 Belden Wire & Cable Company All Rights Reserved. Although Belden Electronics Division ("Belden") makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described herein are subject to error or omission and to change without notice, and the listing of such information and specifications does not ensure product availability. Belden provides the information and specifications herein on an "AS IS" basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract, negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein. All sales of Belden products are subject to Belden's standard terms and conditions of sale. Belden CDT Electronics Division believes this product to be in compliance with the following environmental regulations: California Proposition 65 Consent Judgment For Wire & Cable Mfgs.(San Francisco Superior Court Nos. 312962 And 320342); EU RoHS (Directive 2002/95/EC, 27-Jan-2003);Material manufactured prior to the compliance date may still be in stock at Belden facilities and in our Distributor's inventory. EU ELV (Directive 2000/53/EC, 18-Sept-2000); EU WEEE (Directive 2002/96/EC, 27-Jan-2003); And EU BFR (Directive 2003/11/EC, 6-Feb-2003). The information provided in this Product Disclosure, and the identification of materials listed as reportable or restricted within the Product Disclosure, is correct to the best of Belden's knowledge, information and belief at the date of its publication. The information provided in the Product Disclosure is designed only as a general guide for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. This Product Disclosure is not to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and regulations based on their individual usage of the product. Belden CDT Electronics Division declares this product to be in compliance with EU LVD (Low Voltage Directive 73/23/EEC), as amended by directive 93/68/EEC. Page 3 of 3