SXN15 SERIES
Single output
• High efficiency topology, 87% typical at 5V
• Industry standard footprint
• Wide operating temperature, up to and exceeding 70˚C
(natural convection)
• 90% to 110% output trim
• No minimum load
• Overvoltage protection
• Remote on/off control
The SXN15 is a new high efficiency open frame isolated 15 Watt converter series in
an industry standard footprint. The first four models in the series feature an input
voltage range of 33 to 75VDC and are available in output voltages of 5V, 3.3V, 2.5V
and 1.8V. The output voltage on each model is adjustable from 90% to 110% of
the nominal value. Typical efficiencies for the models are 87% for the 5V, 86% for
the 3.3V, 85% for the 2.5V and 83% for the 1.8V version. The SXN15 series also
has a remote on/off capability with active high or active low logic. Overcurrent and
overvoltage protection features are included as standard. With full international
safety approval including EN60950 and cUL1950, the SXN15 reduces compliance
costs and time to market.
SPECIFICATION
All specifications are typical at nominal input, full load at 25°C unless otherwise stated
PAGE 1
[ 2 YEAR WARRANTY ]
NEW
Product
TÜV
EMC CHARACTERISTICS
Conducted emissions EN55022 (See Note 3) Level A
EN55022 (See Note 3) Level B
Radiated emissions EN55022 (See full data sheet) Level B
Immunity:
ESD air EN61000-4-2 8kV, 15kV
ESD contact EN61000-4-2 6kV, 8kV
Radiated field enclosure EN61000-4-3 10V/m
Conducted (DC power) EN61000-4-6 10V
Conducted (signal) EN61000-4-6 10V (See Note 10)
Input transients ETS 300 132-2, ETR 283
GENERAL SPECIFICATIONS
Efficiency See table
Operational insulation Input/output 1500VDC
Switching frequency Fixed 265kHz typ.
Approvals and (See Note 5) UL/cUL1950, EN60950
standards TÜV Rheinland
Material flammability UL94V-0
Weight 12g (0.42oz)
MTBF MIL-HDBK-217F >600,000 hours
Representative model: 48S05 @ 48Vin, 40°C,
100% load ground benign
BELLCORE 332 >1,500,000 hours
ENVIRONMENTAL SPECIFICATIONS
Thermal performance Operating ambient -40°C to +65°C
(See Note 9) temp. (3.3V and 5V)
Operating ambient -40°C to +70°C
temp. (1.8V and 2.5V)
Non-operating -40°C to +120°C
(All models)
OUTPUT SPECIFICATIONS
Voltage adjustability 90% to 110%
Total error band (See Note 14) ±4% max.
Line regulation 1V8 and 2V5 models 0.5% max.
Low line to high line 3V3 and S05 models 0.1% max.
Load regulation 1V8 model 2.0% max.
Full load to min. load 2V5 model 1.5% max
3V3 and S05 models 0.5% max.
Minimum load 0%
Overshoot 1V8 and 2V5 models 4% max.
At turn-on and tur n-off 3V3 and S05 models None
Undershoot None
Ripple and noise 1V8 and 2V5 models 40mV pk-pk
(See Note 1) 14mV rms
5Hz to 20MHz 3V3 and S05 models 70mV pk-p
20mV rms
Transient response 1V8 and 2V5 models 150mV
(See Note 2) 3V3 and S05 models 100mV
typ. deviation 400µs recovery to
within total error band
INPUT SPECIFICATIONS
Input voltage range 48Vin nominal 33 to 75VDC
Input current No load 35mA max.
Remote OFF 25mA max.
Input current (max.) (See Note 4) 0.55A max. @ Io max.
and Vin = 33 to 75V
Input reflected ripple (See Note 6) 5mA (pk-pk) typ.
Active high remote ON/OFF (See Note 8)
Logic compatibility Open collector ref to -input
ON Open circuit or >2VDC
OFF <1.2VDC
Undervoltage lockout Power up 33V (typ.)
Power down 30V (typ.)
Start-up time Power up 1.5ms (typ.)
(See Note 7) Remote ON/OFF 2.5ms (typ.)
10.8 to 15 Watt
High efficiency DC/DC converters
DC/DC CONVERTERS |10.8 to 15W
DC/DC
http://www.artesyn.com
Data Sheet © Artesyn Technologies
®
2001
The information and specifications contained in this data sheet are believed to be correct at time of publication. However, Artesyn Technologies accepts no responsibility for consequences arising
from printing errors or inaccuracies. Specifications are subject to change without notice. No rights under any patent accompany the sale of any such product(s) or information contained herein.
PAGE 2
Please consult our website for the following items: Full Data Sheet Application Note
Notes
1 Measured as per recommended set-up. See Application Note 116 for
further details.
2 di/dt = 0.1A/µs, Vin = 48VDC, Tc = 25°C, load change = 0.5 lo max. to
0.75 lo max. and 0.75 lo max. to 0.5 lo max.
3 The SXN15 meets level A and level B conducted emissions only with
external components connected before the input pins to the converter.
See Application Note 116 for further details.
4 Recommended input fusing is a 2A HRC 200V rated fuse.
5 This product is only for inclusion by professional installers within other
equipment and must not be operated as a stand alone product.
6 Measured with external filter. See Application Note 116 for further details.
7 Start-up into resistive load.
8. Active low remote on/off is available. Standard product is active high.
Designate with the Suffix '-R' e.g. SXN15-48S05-R.
9. Operating ambient temperatures are specified at natural convection.
Higher operating temperatures are possible with increased airflow. See
Application Note 116 for further details.
10. Signal Line assumed < 3m in length.
11. This parameter is calculated at worst case line, load, temperature and
initial settings.
1.905 (48.39)
TOP VIEW
SIDE VIEW
BOTTOM VIEW
Tolerance: ± .015 (± .38)
Recommended Land & Hole Pattern
1.010 (25.65)
0.335 (8.51)
0.110 (2.79)
0.120 (3.05)
1.680 (42.67)
1.483 (37.67)
1.136 (28.85)
0.302 (7.67)
0.105 (2.67)
0.070 (1.78)
0.840 (21.37) 0.197 (5.00)
0.110 (2.79)
0.130 (3.30)
0.347 (8.81)
1.705 (43.31)
0.800 (20.32)1.020 (25.91)
0.197 (5.00) 1.031 (26.19)
0.820 (20.83)
0.020 (0.51)
0.072 (1.83) 1
156
10 911
4
87
123 56
7810 9
4
11
23
All Dimensions in Inches [mm]
CAUTION: Hazardous internal voltages and high temperatures.
Ensure that unit is not user accessible.
DS_SXN15S_20011115.PDF
PIN CONNECTIONS
PIN NUMBER FEATURE
1 Vout +
2 Vout -
3 N/C
4Trim
5 N/C
6 N/C
7 N/C
8 On/Off
9 N/C
10 Vin -
11 Vin +
International Safety Standard Approvals
UL/cUL 1950 3rd edition. File No. E135734
TÜV TÜV Rheinland. Certificate No. R2074133
OUTPUT INPUT OVP OUTPUT OUTPUT OUTPUT EFFICIENCY REGULATION MODEL
POWER VOLTAGE VOLTAGE CURRENT CURRENT (TYP.) LINE LOAD NUMBER (8)
(MAX.) (MIN.) (MAX.)
10.8W 33-75VDC 2.3VDC 1.8V 0A 6A 83% 0.3% 2.0% SXN15-48S1V8
15W 33-75VDC 3.2VDC 2.5V 0A 6A 85% 0.3% 1.5% SXN15-48S2V5
15W 33-75VDC 4VDC 3.3V 0A 4.5A 86% 0.1% 0.5% SXN15-48S3V3
15W 33-75VDC 6VDC 5.0V 0A 3A 87% 0.1% 0.5% SXN15-48S05
PROTECTION
Short circuit protection Continuous
Overvoltage protection Non-latching clamp
TELECOM SPECIFICATION
Central office interface A ETS300-132-2, input voltage
and current requirements