2 Motorola Thyristor Device Data
THERMAL CHARACTERISTICS
Characteristic Symbol Max Unit
*Thermal Resistance, Junction to Case RθJC 2.2 °C/W
ELECTRICAL CHARACTERISTICS (TC = 25°C, and Either Polarity of MT2 to MT1 Voltage, unless otherwise noted.)
Characteristic Symbol Min Typ Max Unit
*Peak Blocking Current
(VD = Rated VDRM, gate open) TJ = 25°C
TJ = 100°C
IDRM —
——
—10
2µA
mA
*Peak On-State Voltage
(ITM = 11 A Peak; Pulse Width = 1 to 2 ms, Duty Cycle
p
2%) VTM — 1.3 1.55 Volts
Gate Trigger Current (Continuous dc)
(VD = 12 Vdc, RL = 100 Ohms)
(Minimum Gate Pulse Width = 2 µs)
MT2(+), G(+) All Types
MT2(+), G(–) 2N6346 thru 49
MT2(–), G(–) All Types
MT2(–), G(+) 2N6346 thru 49
*MT2(+), G(+); MT2(–), G(–) TC = –40°C All Types
*MT2(+), G(–); MT2(–), G(+) TC = –40°C 2N6346 thru 49
IGT
—
—
—
—
—
—
12
12
20
35
—
—
50
75
50
75
100
125
mA
Gate Trigger Voltage (Continuous dc)
(VD = 12 Vdc, RL = 100 Ohms)
(Minimum Gate Pulse Width = 2 µs)
MT2(+), G(+) All Types
MT2(+), G(–) 2N6346 thru 49
MT2(–), G(–) All Types
MT2(–), G(+) 2N6346 thru 49
*MT2(+), G(+); MT2(–), G(–) TC = –40°C All Types
*MT2(+), G(–); MT2(–), G(+) TC = –40°C 2N6346 thru 49
(VD = Rated VDRM, RL = 10 k Ohms, TJ = 100°C)
*MT2(+), G(+); MT2(–), G(–) All Types
*MT2(+), G(–); MT2(–), G(–) 2N6346 thru 49
VGT
—
—
—
—
—
—
0.2
0.2
0.9
0.9
1.1
1.4
—
—
—
—
2
2.5
2
2.5
2.5
3
—
—
Volts
*Holding Current
(VD = 12 Vdc, Gate Open) TC = 25°C
(IT = 200 mA) *TC = –40°C
IH—
—6
—40
75
mA
*Turn-On Time
(VD = Rated VDRM, ITM = 11 A, IGT = 120 mA,
Rise Time = 0.1 µs, Pulse Width = 2 µs)
tgt — 1.5 2 µs
Critical Rate of Rise of Commutation Voltage
(VD = Rated VDRM, ITM = 11 A, Commutating di/dt = 4.0 A/ms,
Gate Unenergized, TC = 80°C)
dv/dt(c) — 5 — V/µs
*Indicates JEDEC Registered Data.
2.0
4.0
6.0
8.0
10
3.0 7.06.05.04.01.0 2.0
00IT(RMS), RMS ON-STATE CURRENT (AMP)
α
α
dc
30
°
60
°
90
°
120
°
α
= 180
°
TJ
[
100
°
C
8.0
α
= CONDUCTION ANGLE
P , AVERAGE POWER (WATTS)
(AV)
FIGURE 1 – RMS CURRENT DERATING FIGURE 2 – ON-STATE POWER DISSIPATION
1.0 2.0 3.0 4.0 5.0 6.0 7.0
96
92
88
84
80
α
= CONDUCTION ANGLE
α
α
IT(RMS), RMS ON-STATE CURRENT (AMP)
100
8.00
dc
α
= 30
°
60
°
90
°
120
°
180
°
T , CASE TEMPERATURE ( C)
C
°