Enpirion(R) Power Evaluation Board User Guide EN5337QI Enpirion EN5337QI 3A DCDC Converter w/Integrated Inductor Evaluation Board Introduction Thank you for choosing Altera Enpirion power products! * The EN5337QI features integrated inductor, power MOSFETS, Controller, a bulk of the compensation Network, and protection circuitry against system faults. This level of integration delivers a substantial reduction in footprint and part count over competing solutions. However, the evaluation board is not optimized for minimum footprint; rather for engineering ease of evaluation through programming options, clip leads, test points etc. * The EN5337QI features a customer programmable output voltage by means of a resistor divider. The resistor divider allows the user to set the output voltage to any value within the range 0.75V to (VIN-VDROPOUT ). The evaluation board, as shipped is populated with a 4 resistor divider option. The upper resistor is fixed (150k) and has a phase lead capacitor (27pF) in parallel. One of 4 lower resistors is selected with the jumper option for output voltages of 1.0V, 1.2V, 1.55V and 2.5V. To change any of the output voltages, retain the upper resistor and capacitor values and change only the lower resistor. * This device has no over-voltage protection feature. We strongly recommend the customer to ensure the feedback loop is truly closed before powering up the device especially if the load can not withstand the input voltage. * The input capacitor is a 10V rated 22uF X5R MLCC. The output filter section is populated with 1 x 47uF and 1 x10uF, 6.3V rated X5R MLC capacitors to achieve the required ~50uF of output capacitance. This combination of output caps yields very low ESR and hence low output ripple. A single 47uF capacitor may be substituted if minimizing footprint is important. The Soft-start capacitor is a small 10V rated 15nF X5R MLCC. * Pads are available to add an additional input capacitor, and there are a total of 5 pads to accommodate the output capacitor(s). This allows for evaluation of performance over a wide range of input/output capacitor combinations. 1 www.altera.com/enpirion Enpirion(R) Power Evaluation Board User Guide EN5337QI * Clip on terminals are provided for ENA, SS, POK, VIN and VOUT. Other test points are also made available. * A jumper is provided for controlling the Enable signal. Enable may also be controlled using an external switching source by removing the jumper and applying the enable signal to the middle pin and ground. * A jumper is also provided to connect a resistor load to POK pin. This jumper is especially useful to measure the disable current and eliminates having to subtract the current drawn by the POK resistor. * Foot print is also provided for a SMA connector to SYNC input. The SYNC input allows the device switching to be phase locked to an external clock signal. This external clock synchronization allows for moving any offending beat frequency to be moved out-of-band. A swept frequency applied to this pin results in spread spectrum operation and reduces the peaks in the noise spectrum of emitted EMI. * Numerous test points are provided as well as banana plugs for input and output connections. Input / Output ripple are best measured directly across the appropriate capacitors. The switching waveform may be viewed between test points labeled SW and GND. * The board comes with input decoupling and reverse polarity protection to guard the device against common setup mishaps. 2 www.altera.com/enpirion Enpirion(R) Power Evaluation Board User Guide EN5337QI Quick Start Guide o f the Figure 1 shows a top view evaluation board. WARNING: complete steps 1 through 4 before applying power to the EN5337QI evaluation board. STEP 1: Set the "ENABLE" jumper to the Disable Position. Disable Figure 2: Shows POK & Enable JumpersPosition (POK jumper as shown connects pull-up resistor to VIN. Enable jumper shown in DISABLE position.) STEP 2: Connect Power Supply to the input power connectors, VIN (+) and GND (-) as indicated in Figure 1 and set the supply to the desired voltage. The device disable current may be measured in this configuration. CAUTION: be mindful of the polarity. Even though the evaluation board comes with reverse polarity protection diodes, it is rarely a good idea to reverse the input polarity. 3 www.altera.com/enpirion Enpirion(R) Power Evaluation Board User Guide EN5337QI STEP 3: Connect the load to the output connectors VOUT (+) and GND (-), as indicated in Figure 1. STEP 4: Select the output voltage setting jumper. You may also set the POK jumper to include the POK load if POK signal monitoring is intended. The only time to disable POK is when measuring the absolute Disable current. Figure 3: Output Voltage selection jumpers Jumper shown selects 1.2V output (Jumper positions from left are: 2.5V, 1.55V, 1.0V and 1.2V) STEP 5: Apply VIN to the board and move the ENABLE jumper to the enabled position. The EN5337QI is now powered up! Various measurements such as efficiency, line and load regulation, input / output ripple, load transient, drop-out voltage measurements may be made at this point. The over current trip level, short circuit protection, under voltage lock out thresholds, temperature coefficient of the output voltage may also be measured in this configuration. STEP 5A: Power Up/Down Behavior - Remove ENA jumper and connect a pulse generator (output disabled) signal to the middle pin of ENA and Ground. Set the pulse amplitude to swing from 0 to 2.5 volts. Set the pulse period to 10msec. and duty cycle to 50%. Hook up oscilloscope probes to ENA, SS, POK and VOUT with clean ground returns. Apply power to evaluation board. Enable pulse generator output. Observe the SS capacitor and VOUT voltage ramps as ENA goes high and again as ENA goes low. The device when powered down ramps down the output voltage in a controlled manner before fully shutting down. The output voltage level when POK is asserted /de-asserted as the device is powered up / down may be observed as well as the clean output voltage ramp and POK signals. GND Ext. Enable Figure 4: Means to Pulse Enable STEP 6: External Clock Synchronization / Spread Spectrum Modes: In order to activate this mode, it may be necessary to a solder a SMA connector at J8. 4 www.altera.com/enpirion Enpirion(R) Power Evaluation Board User Guide EN5337QI Alternately the input clock signal leads may be directly soldered to the through holes of J8 as shown below. GND Ext. Clock Figure 4: SMA Connector for External Clock Input Power down the device. Move ENA into disable position. Connect the clock signal as just indicated. The clock signal should be clean and have a frequency in the range of 4.5 to 5.5MHz; amplitude 0 to 2.5 volts with a duty cycle between 20 and 80%. With SYNC signal disabled, power up the device and move ENA jumper to Enabled position. The device is now powered up and outputting the desired voltage. The device is switching at its free running frequency. The switching waveform may be observed between test points SW and GND. Now enabling the SYNC signal will automatically phase lock the internal switching frequency to the externally applied frequency as long as the external clock parameters are within the specified range. To observe phase-lock connect oscilloscope probes to the input clock as well as to the SW test point. Phase lock range can be determined by sweeping the external clock frequency up / down until the device just goes out of lock at the two extremes of its range. For spread spectrum operation the input clock frequency may be swept between two frequencies that are within the lock range. The sweep (jitter) repetition rate should be limited to 10kHz. The radiated EMI spectrum may be now measured in various states - free running, phase locked to a fixed frequency and spread spectrum. 5 www.altera.com/enpirion Enpirion(R) Power Evaluation Board User Guide C15 ENA POK EN5337QI J10 1 2 3 1 2 3 J1 C14 R8 EAOUT XFB FB1 PVIN 0805 C13 TP5 0805 0805 EAOUT 26 SYNC ENA 27 29 28 POK SS EAOUT 30 31 XFB 33 34 35 36 37 38 32 AGND AVIN NC(SW) NC(SW) NC(SW) NC(SW) NC(SW) VDDB NC3 BTMP U1 EN5337Q NC4 PG 25 C9 0402 24 23 TP14 1 22 TP4 TP13 21 VIN 20 19 PGND 18 PGND PGND PGND 15 14 PGND 13 12 11 10 9 VOUT 8 7 NC(SW) VIN VOUT VOUT VOUT VIN VOUT VOUT TP6 TP15 AVIN NC(SW) VOUT 6 Add short across R6 when all other routing is completed J8 PGND PGND 8 0805 5 0805 POK NC(SW) 17 6 7 R3 4 0805 TP3 SYNC TP2 3 TP7 TP17 & TP18 are used for special testing. They are not labeled on PCB. TP18 16 4 5 0805 SW 2 R2 TP12 SS TP1 1 C10 0402 C12 XFB J9 ENA TP17 0805 2 3 R1 0805 0805 R5 R7 1 C11 R4 TP16 R6 0805 C5 C6 1206 2 1 2 1 1206/0805 C4 TP10 TP9 1206 C2 J3 1206/0805 GND OUT C3 VOUT GND IN 1206/0805 TP11 VIN PVIN 1 2 J2 TP8 C7 1206/0805 J12 C8 1206/0805 VOUT 1 2 J4 J11 U2 D1 C1 + C16 1 2 J13 2 1 C17 J7 J6 J5 J14 Figure 5: EN5337 Evaluation Board Schematic Output Voltage Select Programming the Output Voltage. The EN5337QI output voltage is programmed using a simple resistor divider network. Figure 6 shows a schematic view of the resistor divider configuration. The EN5337QI output voltage is determined by the voltage presented at the XFB pin. The voltage is set by way of a resistor divider between VOUT and AGND with the midpoint going to XFB. A phase lead capacitor is also required across the upper resistor - the one between VOUT and XFB. 6 www.altera.com/enpirion Enpirion(R) Power Evaluation Board User Guide EN5337QI VIN PVIN 22F POK CA SS CSS VOUT VOUT AVIN RA ~50uF XFB AGND PGND RB Figure 6: VOUT resistor divider network and Phase lead Details. RA =150k, CA = 27pF 0.75V * RA RB = (VOUT - 0.75V ) Test Recommendations Recommendations To guarantee measurement accuracy, the following precautions should be observed: 1. Make all input and output voltage measurements at the board using the test points provided. This will eliminate voltage drop across the line and load cables that can produce false readings. 2. Measure input and output current with series ammeters or accurate shunt resistors. This is especially important when measuring efficiency. 3. Use a balanced impedance probe tip shown below to measure switching signals and input / output ripple to avoid noise coupling into the probe ground lead. Input ripple, output ripple, and load transient deviation are best measured at the respective input / output capacitors. 4. The board includes a pull-up resistor for the POK signal and ready to monitor the power OK status. The POK signal may be viewed at clip lead marked POK. 7 www.altera.com/enpirion Enpirion(R) Power Evaluation Board User Guide EN5337QI 5. A 15nF soft-start capacitor is populated on the board for ~1msec softstart time. 6. The over-current protection circuit typically limits the maximum load current to approximately 1.5X the rated value - nominally 4.5A. Input and Output Capacitors The input capacitance requirement is between 10-20uF X5R/X7R for the EN5337QI. Altera recommends that a low ESR MLC capacitor be used. The voltage rating should be rated high enough to provide adequate margin for your application. There is a pre-tinned pad for one additional 1206 capacitor to experiment with input filter performance. The output capacitance requirement is approximately 50uF of X5R/X7R capacitance. The EN5337QI-E evaluation board comes populated with 1 x 47uF 1206 and 1 x 10uF 0805, 6.3V MLC capacitors. The 2 parallel capacitors provide reduced ESR and hence lower output ripple voltage. If a minimum footprint configuration is desired, a single 47uF MLC capacitor can be used. NOTE: Please refer to product datasheet for specific recommendations. 8 www.altera.com/enpirion Enpirion(R) Power Evaluation Board User Guide EN5337QI Contact Information Altera Corporation 101 Innovation Drive San Jose, CA 95134 Phone: 408-544-7000 www.altera.com/ (c) 2013 Altera Corporation--Confidential. All rights reserved. ALTERA, ARRIA, CYCLONE, ENPIRION, HARDCOPY, MAX, MEGACORE, NIOS, QUARTUS and STRATIX words and logos are trademarks of Altera Corporation and registered in the U.S. Patent and Trademark Office and in other countries. All other words and logos identified as trademarks or service marks are the property of their respective holders as described at www.altera.com/common/legal.html. Altera warrants performance of its semiconductor products to current specifications in accordance with Altera's standard warranty, but reserves the right to make changes to any products and services at any time without notice. Altera assumes no responsibility or liability arising out of the application or use of any information, product, or service described herein except as expressly agreed to in writing by Altera. Altera customers are advised to obtain the latest version of device specifications before relying on any published information and before placing orders for products or services. 9 www.altera.com/enpirion