Features Unregulated Converters * * * * * * * Low cost 1W converter Industry standard pinout SIP4 package 1kVDC isolation Efficiency up to 80% Wide operating temperature range -40C to +85C UL60950-1 and CAN/CSA C22.2 No. 60950-1-07 certified Description The ROE DC/DC converters are typically used in general purpose power isolation and voltage matching applications, and feature a full industrial operating temperature range of -40C to +85C without derating. DC/DC Converter ROE 1 Watt SIP4 Single Output Selection Guide Part Number nom. Input Output Output Efficiency max. Capacitive VoltageVoltageCurrent typ. Load (1) [VDC][VDC] [mA] [%] [F] ROE-3.305S 3.3 5 20079 470 ROE-0505S 5 5 20079 470 ROE-0512S 5 12 8480 220 ROE-0515S 5 15 6680 220 ROE-1205S 12 5 20080 470 ROE-1505S 15 5 20079 470 ROE-2405S 24 5 20080 470 Notes: Note1: Max. capacitive load is tested at nominal input voltage and full load Model Numbering E358085 ROE-__ __ S Sinlge Output lnput Voltage Output Voltage UL60950-1 certified CAN/CSA C22.2 No. 60950-1-07 certified EN60950-1 certified IEC60950-1 certified EN55032 compliant Ordering Examples: ROE-0512S = 5VDC Input Voltage, 12VDC Output Voltage, Single Output ROE-2405S = 24VDC Input Voltage, 5VDC Output Voltage, Single Output www.recom-power.com REV.: 5/2019 ECO-1 ROE DC/DC Converter Series Specifications (measured @ Ta= 25C, nom. Vin, full load and after warm-up unless otherwise stated) BASIC CHARACTERISTICS Parameter Condition Min. Typ. Input Voltage Range Max. 10% Operating Frequency Range Output Ripple and Noise (2) 50kHz 20MHz BW 80kHz 105kHz 50mVp-p 100mVp-p Notes: Note2: Measurements are made with a 100nF MLCC across output (low ESR) ROE-05xxS ROE-xx05S 100 100 90 90 80 80 70 70 Efficiency [%] Efficiency [%] Efficiency vs. Load 60 50 40 30 50 40 30 0505 0512 0515 20 10 0 60 0 10 20 30 40 50 60 70 80 90 3.305 1205 1505 2405 20 10 0 100 0 10 Output Load [%] 20 30 40 50 60 70 80 90 100 Output Load [%] REGULATIONS Parameter Condition Values Output Accuracy 5.0% max. Line Regulation 1.2% typ. / 1.0% Vin low line to high line Load Regulation 20% to 100% load Tolerance Envelope 5Vout 12Vout and 15Vout Vin= 3.3V, 5V Vin= 12V, 15V, 24V Vnom +15% Typical Load Deviation [%] Deviation [%] +15% +5% +5% Line -1% -5% 10 50 +5% +4% Vnom Typical Load Line -2% -5% 10 100 Load Current [%] www.recom-power.com 15% max. 10% max. 50 100 Load Current [%] REV.: 5/2019 ECO-2 ROE DC/DC Converter Series Specifications (measured @ Ta= 25C, nom. Vin, full load and after warm-up unless otherwise stated) PROTECTIONS Parameter Isolation Voltage Condition I/P to O/P (3) Value tested for 1 second 1kVDC Isolation Capacitance 75pF max. Isolation Resistance 1G min. Notes: Note3: For repeat Hi-Pot testing, reduce the time and/or the test voltage Note4: An input fuse is required if the mains supply is not over-current protected. Recommended fuse: T1A slow blow type ENVIRONMENTAL Parameter Condition Operating Temperature Range Value without derating @free air convection (see graph) Operating Humidity -40C to +85C non-condensing 95% RH max. Vibration MTBF MIL-STD-202G (5) according to MIL-HDBK-217F; G.B. 20140 x 103 hours 8674 x 103 hours +25C +85C Notes: Note5: MTBF is referring ROE-3.305S Derating Graph 100 90 Output Load [%] 80 70 60 50 40 30 20 10 0 -40 -30 -20 -10 0 10 20 30 40 50 60 70 80 90 100 110 85 Ambient Temperature [C] SAFETY AND CERTIFICATIONS Certificate Type Report / File Number Standard Information Technology Equipment, General Requirements for Safety E358085-A4-UL UL60950-1, 2nd Edition, 2007 CAN/CSA C22.2 No.60950-1-07, 2nd Edition, 2007 Information Technology Equipment, General Requirements for Safety SPCLVD1602031 IEC60950-1:2005, 2nd Edition + A2:2013 EN60950-1:2006 + A2:2013 EAC RU-AT.49.09571 TP TC 004/2011 RoHS 2+ EMI Compliance Electromagnetic compatibility of multimedia equipment Emission requirements RoHS-2011/65/EU + AM-2015/863 Condition with external filter (see filter suggestion below) Standard / Criterion EN55032, Class B EN55032, Class A continued on next page www.recom-power.com REV.: 5/2019 ECO-3 ROE DC/DC Converter Series Specifications (measured @ Ta= 25C, nom. Vin, full load and after warm-up unless otherwise stated) EMC Filter Suggestion according to EN55032 C2 L1 +Vin +Vin +Vout -Vin -Vout +Vout C1 -Vin -Vout C3 Component List Class A MODEL C1 Component List Class B L1 C2 (safety) C3 (safety) ROE-0505S 6.8F, MLCC N/A ROE-0515S 4.7F, MLCC N/A ROE-1205S 10F 100V MLCC ROE-2405S N/A MODEL C1 L1 C2 (safety) C3 (safety) ROE-0505S 470pF ROE-0515S N/A ROE-1205S N/A 10F 22H choke 100V MLCC RLS-226 330pF 330pF ROE-2405S Notes: Note6: Filter suggestions are valid for indicated part numbers only. For other part numbers, please contact RECOM tech support for advice DIMENSION and PHYSICAL CHARACTERISTICS Parameter Type Value Material case potting non-conductive black plastic, (UL94 V-0) epoxy, (UL94 V-0) Dimension (LxWxH) 11.5 x 6.0 x 10.0mm Weight 1.4g Dimension Drawing (mm) embossed logo 0.250.05 Recommended Footprint Details 2.54 1 2 3 4 Bottom View 2.54 7.62 1.25 1.90 Marking 4.10 0.51 0.51+0.10/-0.05 www.recom-power.com 6.0 10.0 11.5 REV.: 5/2019 Pin Connections Pin # Function 1 -Vin 2 +Vin 3 -Vout 4 +Vout Tolerance: xx.x= 0.50mm xx.xx=0.25mm Top View 1 2 3 4 ECO-4 ROE DC/DC Converter Series Specifications (measured @ Ta= 25C, nom. Vin, full load and after warm-up unless otherwise stated) PACKAGING INFORMATION Parameter Type Value Packaging Dimension (LxWxH) tube 520.0 x 16.0 x 9.0mm Packaging Quantity 42 pcs Storage Temperature Range -55C to +125C The product information and specifications may be subject to changes even without prior written notice.The product has been designed for various applications; its suitability lies in the responsibility of each customer. The products are not authorized for use in safety-critical applications without RECOM's explicit written consent. A safety-critical application is an application where a failure may reasonably be expected to endanger or cause loss of life, inflict bodily harm or damage property. The applicant shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized use of RECOM products in such safety-critical applications. www.recom-power.com REV.: 5/2019 ECO-5