FC4A-SX5ES1E Web Server Unit Web Server Unit A New Powerful Tool for the MicroSmart PLC! messages can be sent to personal computers and mobile phones * Email to alert a user programming a PLC to receive inputs of abnormal machine * * * * conditions. Ethernet communication between PLC and PC enables remote maintenance. Allows for access to data within the PLC using a standard web browser. User communication enables 1:1 communication between PLCs via Ethernet. Connect to the MicroSmart and as well as any operator interface with an Ethernet interface and a TCP/IP client function. Message transmission function The MicroSmart is programmed to detect abnormal conditions of machines. When an error occurs, an email message is sent to the address of mobile phones and personal computers registered within the web server unit. Web Server Unit Trouble! PLC Internet Email Server PLC Remote monitoring and control Operating conditions of machines can be easily monitored and changed from remote places. WindLDR functions can be used on a MicroSmart installed in remote places, for monitoring of machines, configuration, and to upload and download user programs. MicroSmart does not need special user programs to communicate with a PC. Also, not only WindLDR but standard SCADA software applicable to Ethernet enables graphical displays of monitoring and maintenance status. Web Server Unit Ethernet Web Server Unit Monitor and control the web server unit from any PC Web pages stored in the web server unit eliminates the need to add any extra software to configure the MicroSmart. The web server unit can be monitored and controlled from any PC using standard internet browsers such as Internet Explorer. Also, the MicroSmart can read and write operands (JAVA applets created by the user). Network Web Server Unit Factory Data can be exchanged between several MicroSmart units using user communication functions The web server unit connected to a MicroSmart automatically communicates to external devices. Factory A PLC 1 Several MicroSmart units can be monitored with a single PC. Applications can be constructed to display alarm conditions on a PC screen. (The user must create this program.) Also, external devices, such as operator interfaces connected directly to Ethernet, can be controlled using this function. Web Server Unit PLC Factory B PLC 2 MicroSmart MicroSmart The MicroSmart can be connected with an operator interface Operator Interface A Web Server Unit Security protection using passwords Operator Interface B Unauthorized access can be rejected via password protection. Web Server Unit Type Number Product Name Web Server Unit PLC Communication Cable 35mm DIN Rail (aluminium, 1m) Mounting Clip Manual Type No. FC4A-SX5ES1E FC4A-KC3C BAA1000PN10 BNL6PN10 FC9Y-B919 Interface Specifications Quantity 1 1 10 10 1 General Specifications Rated Power Voltage Allowable Voltage Range Current Draw Allowable Momentary Power Interruption Dielectric Strength Insulation Resistance Noise Resistance Inrush Current Operating Temperature Storage Temperature Relative Humidity Pollution Degree Corrosion Immunity Degree of Protection Vibration Resistance Shock Resistance Weight (approx.) 24V DC 20.4 to 26.4V DC 70 mA 10 ms maximum 500V AC, 1 minute 10M minimum (500V DC megger) DC power terminal: 1.0 kV, 50 ns to 1 s Ethernet cable: 0.5 kV, 50 ns to 1 s (coupling clamp) 4A maximum 0 to 55C -40 to +70C (no freezing) 10 to 95% (no condensation) 2 (IEC 60664-1) Free from corrosive gases IP20 (IEC60529) When mounted on a DIN rail: 5 to 9 Hz amplitude 3.5 mm 9 to 150 Hz accelaration 9.8 m/s2 (1G) 2 hours in each of 3 axes 147 m/s2 (15G), 11 ms duration 3 shocks each in 3 axes 150g Dimensions Communication RS232C <=> Ethernet conversion function Electrical characteristics: Complies with IEEE802.3 Transmission speed: 10BASE-T/100BASE-TX (Not CE compliant) Ethernet Specifications Communication protocol: IP/ICMP/ARP Ethernet protocol: TCP/SMTP/HTTP/Telnet No. of TCP connections: 1 Electrical characteristics: EIA RS232C Transmission speed: 9600 to 115200 bps Serial I/F Synchronization: Asynchronous Specifications Communication protocol: Full duplex Transmission control: RTS/CTS, XON/OFF, None Ethernet interface: RJ45 Connection Serial interface: Mini DIN 8-pin connector Method Cable Type No.: FC4A-KC3C Remote maintenance: Uploading, downloading and monitoring using WindLDR via Ethernet Web server: Configure the web server unit using Internet Explorer etc. Reading and writing PLC operands using Java applet. Web file area: 512 Kbyte Compliant browser: Internet Explorer 6.0 Netscape Navigator 7.2 Major Functions Ethernet user communication: User communication using Ethernet Message transmission: Registered outgoing message 32 message types 3 characters max. 2 email addresses 64 address characters max. Connectable Devices * Mounting Hole Layout for Direct Mounting * Programmable Controllers IDEC FC5A MicroSmart (available soon) IDEC FC4A MicroSmart IDEC FC3A OpenNet Controller * Operator Interface (RS232C communication with PLC through Ethernet) IDEC HG2F IDEC HG2S 45.0 35.0 70.0 80.0 70.0 80.0 45.0 Utility CD: Configuration file, PLC operand monitor sample programs, sample program configuration instructions, instruction manual Option * Cable Connection Diagram 2.1 Connector for MicroSmart 5.6mm when the clamp is pulled out PLC Connector Pin No. Port 1 M4 mounting screw (12 mm or 15 mm) (Type No. FC4A-KC3C, Cable Length: 100 mm) * Connector Pinout * Cable Dimensions To MicroSmart To Web Server Unit NC RS 1 DSR 2 NC ER 2 CTS 3 SD 3 SD 4 RD 4 RD RTS 5 NC DR 5 6 CMSW SG 6 NC 7 SG SG 7 GND 8 NC NC SG 8 DTR Cover Shield * Ethernet is a registered trademark of Xerox Corporation. 7-1, Nishi-Miyahara 1-Chome, Yodogawa-ku, Osaka 5-8550, Japan Tel: +81-6-698-571, Fax: +81-6-69-971 E-mail: products@idec.co.jp IDEC CORPORATION (USA) IDEC IZUMI ASIA PTE. LTD. 1175 Elko Drive, Sunnyvale, CA 94089-09, USA Tel: +1-408-747-0550 / (800) 6-IDEC (4) Fax: +1-408-744-9055 / (800) 65-646 E-mail: opencontact@idec.com No. 1, Tannery Lane #05-01, Dragon Land Building, Singapore 47788 Tel: +65-6746-1155, Fax: +65-6844-5995 E-mail: info@sg.idec.com IDEC IZUMI (H.K.) CO., LTD. IDEC CANADA LIMITED Unit -151, Brunel Road Mississauga, Ontario, L4Z 1X, Canada Tel: +1-905-890-8561, Toll Free: (888) 17-4, Fax: +1-905-890-856 E-mail: sales@ca.idec.com Unit 1505-07, DCH Commercial Centre No. 5, Westlands Road, Quarry Bay, Hong Kong Tel: +85-80-8989, Fax: +85-565-0171 E-mail: info@hk.idec.com Unit , Beechwood, Chineham Business Park, Basingstoke, Hampshire RG4 8WA, UK Tel: +44-156-1000, Fax: +44-156-7755 E-mail: sales@uk.idec.com Room 608-609, 6F, Gangtai Plaza, No. 700, Yan'an East Road, Shanghai 0000, China Tel: +86-1-55-1000, Fax: +86-1-55-16 E-mail: idec@cn.idec.com IDEC ELECTRONICS LIMITED IDEC ELEKTROTECHNIK GmbH Wendenstrasse 1, D-057 Hamburg, Germany Tel: +49-40-5 0 54 10, Fax: +49-40-5 0 54 4 E-mail: service@idec.de www.idec.com Pin No. Name 1 Cover Specifications and other descriptions in this catalog are subject to change without notice. Port 2 Connector for Web Server Unit IDEC AUSTRALIA PTY. LTD. IDEC (SHANGHAI) CORPORATION IDEC TAIWAN CORPORATION 8F, No. 79, Hsin Tai Wu Road, Sec. 1, Hsi-Chih, Taipei County, Taiwan Tel: +886--698-99, Fax: +886--698-91 E-mail: service@idectwn.com.tw / Macro Court, Rowville, Victoria 178, Australia Tel: +61--976-44, Toll Free: 1800-68-4, Fax: +61--976-55 E-mail: sales@au.idec.com Cat. No. EP1086-0 JANUARY 006 1DNP PRINTED IN JAPAN