http://www.tracopower.com Page 1 of 3
AC/DC Power Supplies
TOP 60 Series, 60 Watt
Features
60 W power supply in 2.0”x 4.0“ footprint
Single-, dual- and triple output models
Highest efficiency of 88% typ.
Operating temperature range –1C to +70°C
EMI filter meets EN 55022, level B
Compliance with EN 61000-3-2
3-year product warranty
The new TOP-60 series AC/DC open frame power supplies with Industry standard
2.0” x 4.0” (50.8 x 101.6 mm) footprint feature single-, dual- and triple output
models with up to 60 Watt continuous output power. The high efficiency alouds an
operation up to 70°C with convection cooling.
Compliance with global safety and EMC standards qualify these power supplies for
industrial and IT applications.
Order Code Output Power Output 1 Output 2 1) Output 3 1)
nominal
TOP 60105 55 W 5.0 VDC / 11.0 A
TOP 60112 60 W 12 VDC / 5.0 A
TOP 60115 64 W 15 VDC / 4.3 A
TOP 60124 64 W 24 VDC / 2.7 A
TOP 60148 64 W 48 VDC / 1.35 A
TOP 60252 55 W +5.0 VDC / 6.0 A (8.0 A)1) +12 VDC / 3.0 A
TOP 60254 55 W +5.0 VDC / 6.0 A (8.0 A)1) +24 VDC / 1.5 A
TOP 60522 55 W +5.0 VDC / 6.0 A (8.0 A)1) +12 VDC / 3.0 A –12 VDC / 0.5 A
TOP 60533 55 W +5.0 VDC / 6.0 A (8.0 A)1) +15 VDC / 2.4 A –15 VDC / 0.5 A
TOP 60316 38 W +3.3 VDC / 6.0 A (8.0 A)1) +5.2 VDC / 3.0 A +12 VDC / 0.5 A
TOP 60317 38 W +5.0 VDC / 6.0 A (8.0 A)1) +3.3 VDC / 1.5 A +12 VDC / 0.5 A
TOP 60318 55 W +5.0 VDC / 6.0 A (8.0 A)1) +24 VDC / 1.5 A –12 VDC / 0.5 A
Models
1) Peak current for max. 10 s ec. or with forced air cooling
Total power should not exceed nominal power
CB
Scheme
http://www.tracopower.com Page 2 of 3
AC/DC Power Supplies
TOP-60 Series 60 Watt
Input Specifications
Input voltage – nominal 100 – 240 VAC (universal input)
– AC input range 90 – 264 VAC (with derating at low input)
– DC input range 110 – 370 VDC (max. 40 W output power at
input below 120 VDC)
Input frequency 47 – 63 Hz
Harmonic limits EN 61000-3-2, class A
Earth leakage current 150 µA max. @264 VAC, 63 Hz
Inrush current – 115 VAC 30 A typ.
(< 2ms, cold start at 25°C) – 230 VAC 60 A typ.
Input protection T3.15 A internal fuses (line and neutral)
Recommended circuit breaker 5 A (characteristic C or slow blow fuse)
Output Specifications
Voltage set accuracy single output models: 2 % max.
multi output models, output 1: 3 % max.
multi output models, other outputs: 5 % max.
Regulation – Input 0.5 % max.
– Load variation single output models: 2 % max.
multi output models, output 1: 3 % max.
multi output models, other outputs: 5 % max.
Minimum load (to meet regulation specs) multi output models, output 1: 0.5 A
multi output models, output 2: 0.1 A
(not required for single output models and
output 3 of multi output models)
Ripple and noise (20Mhz Bandwidth) 3.3 & 5 VDC models: <100 mVp-p
other models: 1 % Vout
Overvoltage protection (output 1 only) at 110 % – 135 % of Vout nominal
Short circuit protection foldback (automatic recovery)
Capacitive load TOP 60105/60112/60115/60124/60148 models: 3300/2200/1500/470/0 µF max.
TOP 60252/60254 models: 2200/82 µF max.
TOP 60522/60316/60317/60533/60318 models: 1500/5600/1200/470/330 µF max.
Transient response (25 % load step change) 500 µs typ.
Hold-up time – Vin = 110 VAC 12 ms typ.
– Vin = 230 VAC 15 ms typ.
General Specifications
Temperature ranges – Operating 10°C to +70°C
– Storage (non-operating) –40°C to +85°C
Power derating 2.5 %/K above +50°C
Humidity (non condensing) 0 – 95 % rel. H max.
Efficiency 80 – 88 %
75 % for TOP 60316 & TOP 60317
Switching frequency 62 kHz typ. (pulse width modulation)
Altitude during operation up to 3‘000 m (10‘000 ft) approved
Start-up time – Vin = 115 VAC <3.5s
– Vin = 230 VAC <2s
Electromagnetic compatibility – Electrostatic discharge ESD EN 61000-4-2 ±8 kV / ±6 kV
– RF field susceptibility EN 61000-4-3 3 V/m
– Electrical fast transient / burst immunity input EN 61000-4-4 ±2 kV
– Electrical fast transient / burst immunity output EN 61000-4-4 ±2 kV
– Surge immunity line – neutral ground EN 61000-4-5, ±2 kV
– Surge immunity output EN 61000-4-5 ±1 kV
– Immunity to conducted RF disturbances EN 61000-4-6 3 Vrms
– Magnetic field immunity EN 61000-4-8 3 A/m
– Mains voltage dips and interruptions EN 61000-4-11 30 % 500 ms, 60 % 100 ms,
>95 % 10 ms
Specifications can be changed without notice! Make sure you are using the latest documentation, downloadable at www.tracopower.com
www.tracopower.com
Page 3 of 3
Rev. January 13. 2015
Dimensions
AC/DC Power Supplies
TOP-60 Series 60 Watt
AC IN
OUT
3.75 (95.3)
4.0 (101.6)
1.75 (44.5)
2.0 (50.8)
Pillars (not included) for connection to protective earth (PE)
Height: 0.2 min. (5.0), Diam.: 0.25 max. (6.0)
To comply with EN 55022 class B:
Field ground (FG) and protective earth (PE)
are to be connected to chassis
1.18(30.0)
0.09(2.3)
1
6
J1
J2
1
PE
FG
Pin Single output Dual output Triple output
1+Vout 1 Vout 1 Vout 1
2+Vout 1 Vout 1 Vout 1
3–Vout 1 com. com.
4–Vout 1 com. com.
5no con. no con. Vout 3
6no con. Vout 2 Vout 2
Output J2
Pin
1AC in
2AC in
Input J1
J2: Molex Series 41791
mates with Molex crimp terminal: 08-52-0072
and terminal housing: 09-50-3061
Dimensions in Inch, () = mm
General Specifications
Electromagnetic compatibility– Conducted input RI suppression EN 55022 class B, FCC Part 15 class B
(EMC), Emissions – Harmonic current emissions IEC/EN 61000-3-2, class A & D
Isolation voltageInput / Output 4000 VAC
– Input / Field Ground 1500 VAC
Output / Field Ground 500 VAC
Reliability /calculated MTBF (MIL-HDBK-217F, at +25°C, ground benign) >400’000 h
Safety standards – Information technology equipment
IEC/EN 60950-1
Safety approvals – CB certificate (IEC 60950-1) www.tracopower.com/products/top60-cb.pdf
– TÜV certificate (UL 60950-1) www.tracopower.com/products/top60-tuv.pdf
Environment – Vibration acc. IEC 60068-2-6; 3 axis, sine sweep, 10-55Hz, 1g, 1oct/min
– Shock acc. IEC 60068-2-27 3 axis, 15g half sine, 11msShock
20 G (3 directions each 3 times)
Connection pin connector (Molex)
Weight 205 g ( 7. 23 o z )
J1: Molex Series 41791
mates with Molex crimp terminal: 08-52-0072
and terminal housing: 09-50-3031