AC/DC Power Supplies TOP 60 Series, 60 Watt CB Scheme Features 60 W power supply in 2.0"x 4.0" footprint Single-, dual- and triple output models Highest efficiency of 88% typ. Operating temperature range -10C to +70C EMI filter meets EN 55022, level B Compliance with EN 61000-3-2 3-year product warranty The new TOP-60 series AC/DC open frame power supplies with Industry standard 2.0" x 4.0" (50.8 x 101.6 mm) footprint feature single-, dual- and triple output models with up to 60 Watt continuous output power. The high efficiency alouds an operation up to 70C with convection cooling. Compliance with global safety and EMC standards qualify these power supplies for industrial and IT applications. Models Order Code Output Power Output 2 1) Output 1 Output 3 1) nominal TOP 60105 55 W 5.0 VDC / 11.0 A TOP 60112 60 W 12 VDC / 5.0 A TOP 60115 64 W 15 VDC / 4.3 A TOP 60124 64 W 24 VDC / 2.7 A TOP 60148 64 W 48 VDC / 1.35 A TOP 60252 55 W +5.0 VDC / 6.0 A (8.0 A)1) +12 VDC / 3.0 A TOP 60254 55 W 1) +5.0 VDC / 6.0 A (8.0 A) +24 VDC / 1.5 A TOP 60522 55 W +5.0 VDC / 6.0 A (8.0 A)1) +12 VDC / 3.0 A -12 VDC / 0.5 A 55 W 1) +15 VDC / 2.4 A -15 VDC / 0.5 A 1) +5.2 VDC / 3.0 A +12 VDC / 0.5 A 1) +3.3 VDC / 1.5 A +12 VDC / 0.5 A 1) +24 VDC / 1.5 A -12 VDC / 0.5 A TOP 60533 TOP 60316 TOP 60317 TOP 60318 38 W 38 W 55 W +5.0 VDC / 6.0 A (8.0 A) +3.3 VDC / 6.0 A (8.0 A) +5.0 VDC / 6.0 A (8.0 A) +5.0 VDC / 6.0 A (8.0 A) 1) http://www.tracopower.com Peak current for max. 10 sec. or with forced air cooling Total power should not exceed nominal power Page 1 of 3 AC/DC Power Supplies TOP-60 Series 60 Watt Input Specifications Input voltage - nominal - AC input range - DC input range 100 - 240 VAC (universal input) 90 - 264 VAC (with derating at low input) 110 - 370 VDC (max. 40 W output power at input below 120 VDC) Input frequency 47 - 63 Hz Harmonic limits EN 61000-3-2, class A Earth leakage current 150 A max. @264 VAC, 63 Hz Inrush current (< 2ms, cold start at 25C) 30 A typ. 60 A typ. - 115 VAC - 230 VAC Input protection T3.15 A internal fuses (line and neutral) Recommended circuit breaker 5 A (characteristic C or slow blow fuse) Output Specifications Voltage set accuracy single output models: 2 % max. multi output models, output 1: 3 % max. multi output models, other outputs: 5 % max. Regulation - Input - Load variation single output models: multi output models, output 1: multi output models, other outputs: 0.5 % max. 2 % max. 3 % max. 5 % max. Minimum load (to meet regulation specs) multi output models, output 1: 0.5 A multi output models, output 2: 0.1 A (not required for single output models and output 3 of multi output models) Ripple and noise (20Mhz Bandwidth) 3.3 & 5 VDC models: <100 mVp-p other models: 1 % Vout Overvoltage protection (output 1 only) at 110 % - 135 % of Vout nominal Short circuit protection foldback (automatic recovery) Capacitive load TOP 60105/60112/60115/60124/60148 models: 3300/2200/1500/470/0 F max. TOP 60252/60254 models: 2200/82 F max. TOP 60522/60316/60317/60533/60318 models: 1500/5600/1200/470/330 F max. Transient response (25 % load step change) 500 s typ. Hold-up time - Vin = 110 VAC 12 ms typ. - Vin = 230 VAC 15 ms typ. General Specifications Temperature ranges - Operating -10C to +70C - Storage (non-operating) -40C to +85C Power derating 2.5 %/K above +50C Humidity (non condensing) 0 - 95 % rel. H max. Efficiency 80 - 88 % 75 % for TOP 60316 & TOP 60317 Switching frequency 62 kHz typ. (pulse width modulation) Altitude during operation up to 3`000 m (10`000 ft) approved Start-up time - Vin = 115 VAC <3.5s - Vin = 230 VAC<2s Electromagnetic compatibility - Electrostatic discharge ESD EN 61000-4-2 - RF field susceptibility EN 61000-4-3 - Electrical fast transient / burst immunity input EN 61000-4-4 - Electrical fast transient / burst immunity output EN 61000-4-4 - Surge immunity line - neutral ground EN 61000-4-5, - Surge immunity output EN 61000-4-5 - Immunity to conducted RF disturbances EN 61000-4-6 - Magnetic field immunity EN 61000-4-8 - Mains voltage dips and interruptions EN 61000-4-11 http://www.tracopower.com 8 kV / 6 kV 3 V/m 2 kV 2 kV 2 kV 1 kV 3 Vrms 3 A/m 30 % 500 ms, 60 % 100 ms, >95 % 10 ms Page 2 of 3 AC/DC Power Supplies TOP-60 Series 60 Watt General Specifications Electromagnetic compatibility- Conducted input RI suppression EN 55022 class B, FCC Part 15 class B (EMC), Emissions - Harmonic current emissions IEC/EN 61000-3-2, class A & D Isolation voltage - Input / Output 4000 VAC - Input / Field Ground 1500 VAC - Output / Field Ground 500 VAC Reliability /calculated MTBF (MIL-HDBK-217F, at +25C, ground benign) >400'000 h Safety standards IEC/EN 60950-1 - Information technology equipment Safety approvals - CB certificate (IEC 60950-1) - TUV certificate (UL 60950-1) www.tracopower.com/products/top60-cb.pdf www.tracopower.com/products/top60-tuv.pdf Environment - Vibration acc. IEC 60068-2-6; 3 axis, sine sweep, 10-55Hz, 1g, 1oct/min - Shock acc. IEC 60068-2-27 3 axis, 15g half sine, 11msShock 20 G (3 directions each 3 times) Connection pin connector (Molex) Weight 205 g (7.23 oz) Dimensions Input J1 4.0 (101.6) 3.75 (95.3) PE 2.0 (50.8) OUT 1.75 (44.5) J2 1 0.09(2.3) J1 AC IN 1.18(30.0) 1 Pin 6 1 AC in 2 AC in J1: Molex Series 41791 mates with Molex crimp terminal: 08-52-0072 and terminal housing: 09-50-3031 FG Pillars (not included) for connection to protective earth (PE) Height: 0.2 min. (5.0), Diam.: 0.25 max. (6.0) To comply with EN 55022 class B: Field ground (FG) and protective earth (PE) are to be connected to chassis Output J2 Pin Single output Dual output Triple output 1 +Vout 1 Vout 1 Vout 1 2 +Vout 1 Vout 1 Vout 1 3 -Vout 1 com. com. 4 -Vout 1 com. com. 5 no con. no con. Vout 3 6 no con. Vout 2 Vout 2 J2: Molex Series 41791 mates with Molex crimp terminal: 08-52-0072 and terminal housing: 09-50-3061 Dimensions in Inch, () = mm Specifications can be changed without notice! Make sure you are using the latest documentation, downloadable at www.tracopower.com Rev. January 13. 2015 www.tracopower.com Page 3 of 3