Electrical Products Division
6801 River Place Blvd.
Austin, TX 78726-9000
http://www.3M.com/elpd Litho in USA.
© 3M 2002 78-8126-0411-0-A
IMPORTANT NOTICE
Before using this product, you must evaluate it and determine if it is suitable for your intended application. You assume all risks and liability
associated with such use.
Warranty; Limited Remedy; Limited Liability. This product will be free from defects in material and manufacture as of the date of
purchase. 3M MAKES NO OTHER WARRANTIES INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OF
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. If this product is defective within the warranty period stated above,
your exclusive remedy shall be, at 3M’s option, to replace or repair the 3M product or refund the purchase price of the 3M product. Except
where prohibited by law, 3M will not be liable for any loss or damage arising from this 3M product, whether direct, indirect,
special, incidental or consequential regardless of the legal theory asser ted.
Engineering Specification
Crimp-type female disconnects shall, electrically and
mechanically, connect permanently to the prestripped
end of a stranded copper wire: and have a tongue
portion with fingers which grip a male disconnect in a
separable, reusable manner, forming a quick connect
wiring termination.
The connector line shall offer tongue variations (sized
to grip male tabs: 0.250˝ x 0.032˝ or 0.187˝ x 0.020˝
per ANSI/NEMA CD-2), and barrel variations in wire
(AWG) size: (22-18, 16-14, 12-10) and construction
(non-insulated, vinyl insulated and nylon fully
insulated insulated, etc.). The female disconnects shall
have regulatory agency coverage (UL Listing, CSA
Certified). The tongue portion shall be marked with
the wire range and manufacturer’s symbol ().
The vinyl insulated female disconnect, shall be tin
plated 0.016˝ thick brass with a tongue for gripping a
0.187˝ x 0.020˝ male tab per ANSI/NEMA CD-2 and a
0.250˝ long barrel with a tin plated brass funnel entry
insulation grip, covered by a molded vinyl sleeve,
color coded and sized for a specified (AWG) wire
range (Red, 22-18: Blue, 16-14).
Insulated connectors shall be UL Listed and CSA
Certified for 600 volts minimum, building wire: 1000
volt maximum; signs or fixtures (luminaires) and
temperature rated 221˚F (105˚C) maximum.
Female Disconnects shall be suitable for field or
factory wiring, with a UL Recognized strain relief
required.
3M and Scotchlok are trademarks of 3M.
is a trademark of Underwriters Laboratories.
is a trademark of Canadian Standards Association.