Solid State Relay G3MC 401
Solid State Relay
G3MC
Compact, Thin-profile, Low-cost SSR with
Reinforced Insulation
Small bottom surface area (approx. 80% of the
conventional G3MB’s), ideal for close PCB mounting.
DC input and AC output for an applicable load of 1A at 40°C
.
Compact, thin-profile SSR of monoblock construction with
an all-in-one frame incorporates a PCB, terminals, and a
heatsink.
Approved by UL and CSA. VDE certified models available.
Models with reinforced insulation are available.
Ordering Information
To Order: Select the part number and add the desired coil voltage rating, (e.g., G3MC-101P-DC12).
Note: 1. All models meet UL and CSA standards. In order to obtain VDE approved versions with UL, CSA and VDE Logos, add “-VD” to the part
number. Example: G3MC-101P-VD-DC12
2. 2A models are available with reinforced insulation. Add “-1” to the part number to obain 2A models with reinfored insulation.
Examples: G3MC-202PL-1-DC5 G3MC-202P-VD-1-DC24
Isolation Zero-cross function Built-in snubber circuit Rated output load Rated input voltage Part number
Phototriac Yes Yes 1 A at 100 to 120 VAC
(75 to 132 VAC)
5 VDC G3MC-101P
12 VDC
24 VDC
No 5 VDC G3MC-101PL
12 VDC
24 VDC
Yes 2 A at 100 to 240 VAC
(75 to 264 VAC)
5 VDC G3MC-202P
12 VDC
24 VDC
No 5 VDC G3MC-202PL
12 VDC
24 VDC
402 Solid State Relay G3MC
Specifications
Ratings (Ambient temperature 25°C)
Input
Note: Each model has 5-VDC, 12-VDC, and 24-VDC input versions.
Output
Characteristics
Rated voltage Operating voltage Impedance Voltage levels
Must operate voltage Must dropout voltage
5 VDC 4 to 6 VDC 300Ω ±20% 4 VDC max. 1 VDC min.
12 VDC 9.6 to 14.4 VDC 800Ω ±20% 9.6 VDC max.
24 VDC 19.2 to 28.8 VDC 1.6kΩ ±20% 19.2 VDC max.
Part number Applicable load
Rated load voltage Load voltage range Load current Surge current
G3MC-101P(L)(-VD) 100 to 120 VAC, 50/60 Hz 75 to 132 VAC, 50/60 Hz 0.1 to 1 A 8 A (60 Hz, 1 cycle)
G3MC-202P(L)(-VD)(-1) 100 to 240 VAC, 50/60 Hz 75 to 264 VAC, 50/60 Hz 0.1 to 2 A 30 A (60 Hz, 1 cycle)
Item G3MC-101P(-VD) G3MC-101PL(-VD) G3MC-202P(-VD)(-1) G3MC-202PL(-VD)(-1)
Operate time 1/2 of load power source
cycle + 1 ms
1 ms max. 1/2 of load power source
cycle + 1 ms
1 ms max.
Release time 1/2 of load power source cycle + 1 ms)
Output ON voltage drop 1.6 V (RMS) max.
Leakage current 1 mA max. (at 100 VAC) 1.5 mA max. (at 200 VAC)
Insulation resistance 1,000 MΩ min. (at 500 VDC)
Dielectric strength 2,500 VAC, 50/60 Hz for 1 min (3,000 VAC, 50/60 Hz for 1 min. for G3MC-@@@-VD-1)
Vibration resistance Malfunction: 10 to 55 Hz, 0.75-mm double amplitude
Shock resistance Malfunction: 1,000 m/s2 (approx. 100G)
Ambient temperature Operating:–30°C to 80°C (with no icing or condensation)
Storage:–30°C to 100°C (with no icing or condensation)
Approved standards UL File No. E64562, CSA File No. LR35535
EN60950 File No. 5925UG (“-VD(-1)” type)
Ambient humidity Operating: 45% to 85%
Weight Approx. 2.5g (Approx. 5g for G3MC-202P(L)-VD-1)
Solid State Relay G3MC 403
Engineering Data
G3MC-101P(L)(-VD)
G3MC-202P(L)(-VD)(-1)
Peak inrush current (A)
Energized time (ms)
1.2
1.0
0.8
0.6
0.4
0.2
01008060402002030
Load current (A)
Ambient temperature (°C)
Load Current vs. Ambient
Temperature Characteristics
Inrush Current Resistivity
One cycle, non-repetitive (Keep the inrush current
to half the rated value if it occurs repeatedly.)
2.5
2.0
1.5
1.0
0.5
010080604020 2502030
Load current (A)
Ambient temperature (°C)
Load Current vs. Ambient
Temperature Characteristics
Inrush Current Resistivity
One cycle, non-repetitive (Keep the inrush current
to half the rated value if it occurs repeatedly.)
Peak inrush current (A)
Energized time (ms)
404 Solid State Relay G3MC
Dimensions
Units: mm (inch)
G3MC-202P(L)(-VD)(-1)
G3MC-101P(L)(-VD)
0.8
3.5
2.54
2.54 0.25
1.2
4-1.6 4-0.7
7.6210.16
0.8
3.5
2.54
2.54 0.25
1.2
4-1.6 4-0.7
7.6210.16
13.5 max.
24.5 max.
4.5 max. Four, 1.0-dia. holes
Four, 1.0-dia. holes
4.5 max.
20.5 max.
24.5 max.
PCB Dimensions
(Bottom View)
PCB Dimensions
(Bottom View)
Terminal Arrangement
(Bottom View)
Terminal Arrangement
(Bottom View)
Solid State Relay G3MC 405
Precautions
General Precautions
Do not touch the terminals of the SSR while power is being supplied
to the SSR. The terminals are charged with the power,
and an electric shock may be received by touching the terminals.
The built-in capacitor may have a residual voltage after the SSR
is turned off. Be sure to discharge the residual voltage before touch-
ing the terminals of the SSR, otherwise an electric shock
may be received.
Mounting
1. Make sure that no excessive voltage or current is imposed on or
flows to the input or output circuit of the SSR,
otherwise the SSR may malfunction or burn.
2. Solder the terminals of the SSR properly under the required sol-
dering conditions. The SSR may be abnormally heated and burn
if power is supplied to the terminals soldered incorrectly.
3. Do not short-circuit the load of the SSR while power is supplied to
the SSR. Do not short-circuit the power supply through the SSR.
The SSR may be damaged, malfunction, or burn if the load or
power supply is short-circuited.
Correct use
The terminals of the SSR are highly heat-conductive. Each terminal
must be soldered within 10 s at 260°C or within 5 s at 350°C.
The SSR is of a thin-profile construction. To maintain the vibration
resistance of the SSR, make sure that the space between the SSR
and PCB is 0.1 mm maximum. Lifting of the PCB can be prevented
by setting the hole diameter of the PCBs on both sides slightly
smaller than the actual terminal dimension.
Select the model without the zero-cross function when using the Unit
for phase control output.
The casing works as a heat sink. When mounting two or more Units
closely, make sure that the Units are properly ventilated by taking
ambient temperature rises into consideration. If Units are closely
mounted and used in places with no ventilation, the load current of
each Unit must be 1/2 of the rated load current.
Protective element
No overvoltage absorption element is built in. Therefore, if the G3MC
is connected to an inductive load, be sure to connect the overvoltage
absorption element.
G3MC-@@@PL (without Zero cross function)
G3MC-@@@P (with Zero cross function)
Phototriac
Input
Load
Protective
element
(MOV)
Power
supply
Phototriac
Input
Load
Protective
element
(MOV)
Power
supply
Solid State Relay G3MC
OMRON ON-LINE
Global - http://www.omron.com
USA - http://www.components.omron.com
Cat. No. X301-E-1b Printed in USA
OMRON ELECTRONIC
COMPONENTS LLC
55 E. Commerce Drive, Suite B
Schaumburg, IL 60173
847-882-2288
09/11 Specifications subject to change without notice
All sales are subject to Omron Electronic Components LLC standard terms and conditions of sale, which
can be found at http://www.components.omron.com/components/web/webfiles.nsf/sales_terms.html
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.