Extract from the online catalog HC-M-HS 200/40-MOD-ST-PE Order No.: 1637184 http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=1637184 HEAVYCON contact insert module, connector, 1-pos., for axial screw connection, 200 A, 25-40 mm, for the PE connection Product notes WEEE/RoHS-compliant since: 10/31/2006 Commercial data EAN 4046356095235 Pack 1 pcs. Customs tariff 85366990 Weight/Piece 0.0985 KG Catalog page information Page 451 (PC-2009) http:// www.download.phoenixcontact.com Please note that the data given here has been taken from the online catalog. For comprehensive information and data, please refer to the user documentation. The General Terms and Conditions of Use apply to Internet downloads. Technical data Electrical characteristics Note Required for housing HC-B6 to B48, (housing height min. 72 mm), housing HC-ADVANCE-B6 to B24, hinged retaining frame HC-M-MHR..., axial connection for 5 mm Allen wrench Rated current 200 A PHOENIX CONTACT GmbH & Co. KG http://www.phoenixcontact.com Page 1 / 4 Jul 6, 2009 HC-M-HS 200/40-MOD-ST-PE Order No.: 1637184 http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=1637184 Ambient temperature (operation) -40 C ... 125 C Number of positions 1 Mechanical characteristics Conductor cross section 25 mm ... 40 mm Connection cross section AWG 3 ... 2 Stripping length of the individual wire 16 mm Tightening torque 8 Nm (25-35 mm ) 2 2 9 Nm (40 mm ) Wire diameter including insulation 12 mm Hexagonal socket WAF 5 Insertion/withdrawal cycles 500 General characteristics Number of module slots 2 Connection method Axial screw connection Inflammability class acc. to UL 94 V0 Assembly instructions - Use only flexible conductors,- Connection of wires with 5 mm an Allen wrench,- Housing height h 72 mm,- Connectors may only be operated without load/voltage. Connection Note for axial connection method The specified conductor cross-sections refer to the geometric cross-section of the used conductor.The use of conductors with a geometric crosssection that deviates greatly from the nominal cross-section of the conductor should be checked first.The wiring space of the axial screw technology has been designed for fine strand conductors as per VDE 0295 class 5. Deviating conductor superstructures (e.g. class 6 conductors) must be checked before use.Connection It must be ensured before installation that the ball screw is completely turned back (chamber is open). Twisting the conductors is not allowed. The cores must be pushed up to the end of the contact chamber (until the contact is insulated). Keep the core in this position and tighten it using an Allen key. The required core end must be cut before a reconnection. Tightening the connection screw is allowed only once in order to prevent a breakage of the litz wire. Material data Contact material Copper alloy Contact surface material Ag Contact carrier material PC PHOENIX CONTACT GmbH & Co. KG http://www.phoenixcontact.com Page 2 / 4 Jul 6, 2009 HC-M-HS 200/40-MOD-ST-PE Order No.: 1637184 http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=1637184 Drawings Diagram Three modules in B24 housing Two modules in B24 housing Dimensioned drawing Male insert Schematic diagram Axial screw connection PHOENIX CONTACT GmbH & Co. KG http://www.phoenixcontact.com Page 3 / 4 Jul 6, 2009 HC-M-HS 200/40-MOD-ST-PE Order No.: 1637184 http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=1637184 Address PHOENIX CONTACT GmbH & Co. KG Flachsmarktstr. 8 32825 Blomberg,Germany Phone +49 5235 3 00 Fax +49 5235 3 41200 http://www.phoenixcontact.com (c) 2009 Phoenix Contact Technical modifications reserved; PHOENIX CONTACT GmbH & Co. KG http://www.phoenixcontact.com Page 4 / 4 Jul 6, 2009