DATASHEET3-Phase FiltersFN 258
Book-style EMC/RFI Filter for Inverters and Power Drive Systems
Industry standard EMC solution for three-phasePDS filteringSlim space-saving book-style housingSolid safety connector blocks or optional wireoutput connectionsExcellent attenuation performanceHV versions for up to 690 VACHVIT versions for IT distribution networksP/L versions with low leakage currentPerformance indicatorsTechnical specifications
Maximum continuous operating voltage 3x 520/300 VAC (FN 258, FN 258 L, FN 258 P)3x 760/440 VAC (FN 258 HV, FN 258 HVIT)Rated currents 7 to 250 A @50°C (480 V filters)Operating frequency DC to 60 HzHigh potential test voltage P –> E 2650 VDC for 2 sec (FN 258)P –> P 2100 VDC for 2 sec (FN 258)P –> E 2000 VAC for 2 sec (FN 258L)P –> P 2100 VDC for 2 sec (FN 258L)P –> E 3000 VDC for 2 sec (FN 258P)P –> P 2100 VDC for 2 sec (FN 258P)P –> E 3200 VDC for 2 sec (FN 258HV and FN 258HVIT)P –> P 3270 VDC for 2 sec (FN 258HV and FN 258HVIT)Protection category IP 20Overload capability 4x rated current at switch on,1.5x rated current for 1 minute, once per hourTemperature range (operation and storage) -25°C to +100°C (25/100/21)Flammability corresponding to UL 94 V-2 or betterDesign corresponding to UL 1283, CSA 22.2 No. 8 1986, IEC/EN 60939MTBF @ 50°C/400 V (Mil-HB-217F) 220,000 hoursApprovals
UL/CSA: FN 258 up to 180 A (ex. -180-07)
Features and benefits
FN 258 range of filters provides state-of- the-art EMIattenuation based on an innovative multi-stagefilter topology. They help to ensure compliance withClass A or even Class B limitsThe slim book-style shape allows a convenient andspace-saving installation next to inverters andmotor drivesWith 480 VAC rating and filter modules from 7 to250 A, FN 258 are ready for the most diverseapplications worldwideFN 258 HV filters up to 130 A are designed for 690VAC distribution networksFN 258 HVIT filters up to 130 A meet the specialrequirements for the application in industrial 690VAC IT distribution networksFN 258 L and FN 258 P filters help to fulfill toughrequirements in respect of leakage currentlimitation and provide an excellent solution toovercome problems with nuisance tripping ofsensitive earth leakage detectors
Typical applications
Three-phase variable speed drives and power drivesystems (PDS)IT power distribution networks (FN 258 HVIT)Applications comprising energy conversion devices(inverters, converters)Process automation equipmentThree-phase power supplies and UPSApplications with low-leakage current requirements(FN 258 L and FN 258 P)
Typical electrical schematic
2EMC/EMI ProductsSchaffner Group Datasheets 11 Oct 2018Filter selection table
Filter* Rated current Typical drive Leakage current*** Power loss Input Output Weight
@ 50°C (40°C) power rating** @ 520/760 VAC/50 Hz @ 25°C/50 Hz connections connections
[A] [kW] [mA] [W] [kg]
FN 258-7-.. 7 (7.7)42.09-29-07-291.0FN 258-16-.. 16 (17.5)7.52.120-29-07-291.4FN 258-30-.. 30 (33)152.921-33-07-331.7FN 258-42-.. 42 (46)223.030-33-07-332.5FN 258-55-.. 55 (60)303.030-34-07-342.9FN 258-75-34 75 (82)373.024-34-343.9FN 258-100-35 100 (110)553.051-35-355.5FN 258-130-35 130 (143)753.550-35-356.9FN 258-180-.. 180 (197)903.573-40-07-4011.0FN 258-250-.. 250 (275)1323.479-40-07-4012.0FN 258 HV-7-29 7 (7.7)5.51.69-29-291.0FN 258 HV-16-29 16 (17.5)112.320-29-291.5FN 258 HV-30-33 30 (33)222.321-33-331.8FN 258 HV-42-33 42 (46)302.630-33-332.6FN 258 HV-55-34 55 (60)452.630-34-343.0FN 258 HV-75-34 75 (82)552.624-34-344.3FN 258 HV-100-35 100 (110)902.651-35-355.6FN 258 HV-130-35 130 (143)1102.950-35-357.1FN 258 HVIT-7-29 7 (7.7)5.50.19-29-291.0FN 258 HVIT-16-29 16 (17.5)110.120-29-291.5FN 258 HVIT-30-33 30 (33)220.121-33-331.8FN 258 HVIT-42-33 42 (46)300.130-33-332.6FN 258 HVIT-55-34 55 (60)452.630-34-343.0FN 258 HVIT-75-34 75 (82)552.624-34-344.3FN 258 HVIT-100-35 100 (110)902.651-35-355.6FN 258 HVIT-130-35 130 (143)1102.950-35-357.1FN 258 L-7-.. 7 (7.7)40.19-29-07-291.0FN 258 L-16-.. 16 (17.5)7.50.120-29-07-291.4FN 258 L-30-.. 30 (33)150.121-33-07-331.7FN 258 L-42-.. 42 (46)220.130-33-07-332.5FN 258 L-55-.. 55 (60)300.130-34-07-342.9FN 258 L-75-34 75 (82)370.124-34-343.9FN 258 L-100-35 100 (110)550.151-35-355.5FN 258 L-130-35 130 (143)750.150-35-356.9FN 258 L-180-.. 180 (197)900.173-40-07-4011.0FN 258 L-250-07 250 (275)1320.179-40-0712.0FN 258 P-7-.. 7 (7.7)40.49-29-07-291.0FN 258 P-16-.. 16 (17.5)7.50.420-29-07-291.4FN 258 P-30-.. 30 (33)150.421-33-07-331.7FN 258 P-42-.. 42 (46)220.430-33-07-332.5FN 258 P-55-.. 55 (60)300.430-34-07-342.9FN 258 P-75-34 75 (82)370.424-34-343.9FN 258 P-100-35 100 (110)550.451-35-355.5FN 258 P-130-35 130 (143)750.450-35-356.9FN 258 P-180-.. 180 (197)900.473-40-07-4011.0FN 258 P-250-07 250 (275)1320.479-40-0712.0***To compile a complete part number, please replace the -.. with the required output connection style.***Calculated at rated current, 440 VAC (FN 258)/690 VAC (FN 258 HV) and cos phi=0.8. The exact value depends upon the efficiency of the drive, the motor and the entire***application.*** Standardized calculated leakage current acc. IEC60939 under normal operating conditions (FN 258 at 520 VAC and FN 258 HV at 760 VAC).
3EMC/EMI ProductsSchaffner Group Datasheets 11 Oct 2018Typical filter attenuation
Per CISPR 17; A=50 Ω/50 Ω sym; B=50 Ω/50 Ω asym; C=0.1 Ω/100 Ω sym; D=100 Ω/0.1 Ω sym
7 to 30 A types
42 to 100 A types
130 A types
180 and 250 A types
Note: typical attenuation performance of FN 258 standard filters. The behavior of FN 258 HV, FN 258 HVIT, FN 258 P and FN 258 L may be slightly different.
Mechanical data
7 to 55 A types (-07)7 to 130 A types (-29, -33, -34, -35)180 and 250 A types (-07)180 and 250 A types (-40)
Note: in favour of a better readability, connectors and earth studs are not shown in the horizontal projection.
4EMC/EMI ProductsSchaffner Group Datasheets 11 Oct 2018Dimensions
7 A 16 A 30 A 42 A 55 A 75 A 100 A 130 A 180 A 250 A
A255305335329329329379439438478B50556070808090110110110C126142150185185220220240240240D225275305300300300350400400440E240290320314314314364414413453F25303545555565808080G6.56.56.56.56.56.56.56.56.56.5H1111.51.51.51.5344I10.910.92525393945455151JM5M5M5M6M6M6M10M10M10M10K2527.53035404045555555L85100110130105140130140110110X* AWG 16AWG 14AWG 10AWG 8AWG 650 mm270 mm2Y* 300 ±10300 ±10400 ±10500 ±10500 ±10500 ±10500 ±10Z* 99912121515* Filters with output wire connections (-07) only.All dimensions in mm; 1 inch = 25.4 mmTolerances according: ISO 2768-m/EN 22768-m
Filter input/output connector cross sections
-29 -33 -34 -35 -40
Solid wire 6 mm216 mm235 mm250 mm295 mm2Flex wire 4 mm210 mm225 mm250 mm295 mm2AWG type wire AWG 10AWG 6AWG 2AWG 1/0AWG 4/0Recommended torque 0.6-0.8 Nm1.5-1.8 Nm4.0-4.5 Nm7-8 Nm17-20 NmPlease visit www.schaffner.com to find more details on filter connectors.
5EMC/EMI ProductsSchaffner Group Datasheets 11 Oct 2018
TofindyourlocalpartnerwithinSchaffner‘sglobal network: www.schaffner.com© 2018 Schaffner GroupThecontentofthisdocumenthasbeencarefullycheckedandunderstood.However,neitherSchaffnernoritssubsidiariesassumeanyliabilitywhatsoeverforanyerrorsorinaccuraciesofthisdocumentandtheconsequencesthereof.Publishedspecifica-tionsaresubjecttochangewithoutnotice.Productsuitabilityforanyareaofapplicationmustultimatelybedeterminedbythecustomer.Inallcases,productsmustneverbeoperatedoutsidetheirpublishedspecifications.Schaffnerdoesnotguaranteetheavailabilityofallpublishedproducts.ThisdisclaimershallbegovernedbysubstantiveSwisslawandresultingdisputesshallbesettledbythecourtsattheplaceofbusinessofSchaffnerHoldingAG.Latestpublicationsandacompletedisclaimercanbedownloa-dedfromtheSchaffnerwebsite.Alltrademarks recognized.
Headquarters, global
innovation and development
SwitzerlandSchaffner Group
Nordstrasse 114542 LuterbachT +41 32 681 66 26info@schaffner.comwww.schaffner.com
Sales and application centers
ChinaSchaffner EMC Ltd. Shanghai
T20-3 C, No 565 Chuangye Road,Pudong district201201 ShanghaiT +86 21 3813 9500cschina@schaffner.comwww.schaffner.com.cnFinlandSchaffner Oy
Sauvonrinne 19 H08500 LohjaT +358 50 468 7284finlandsales@schaffner.comFranceSchaffner EMC S.A.S.
16-20 Rue Louis Rameau95875 BezonsT +33 1 34 34 30 60F +33 1 39 47 02 28francesales@schaffner.comGermanySchaffner Deutschland GmbH
Schoemperlenstrasse 12B76185 KarlsruheT +49 721 56910F +49 721 569110germanysales@schaffner.comIndiaSchaffner India Pvt. Ltd
REGUS WORLD TRADE CENTREWTC, 22nd Floor Unit No 2238, BrigadeGateway Campus, 26/1, Dr. Rajkumar RoadMalleshwaram (W)560055 BangaloreT +91 80 67935355indiasales@schaffner.comItalySchaffner EMC S.r.l.
Via Ticino, 3020900 Monza (MB)T +39 039 21 41 070italysales@schaffner.comJapanSchaffner EMC K.K.
1-32-12, Kamiuma, Setagaya-ku7F Mitsui-seimei Sangenjaya Bldg.154-0011 TokyoT +81 3 5712 3650F +81 3 5712 3651japansales@schaffner.comwww.schaffner.jpSingaporeSchaffner EMC Pte Ltd.
#05-09, Kg Ubi Ind. Estate408705 SingaporeT +65 6377 3283F +65 6377 3281singaporesales@schaffner.comSpainSchaffner EMC España
Calle Caléndula 93, Miniparc III, Edificio EEl Soto de Moraleja, Alcobendas28109 MadridT +34 917 912 900F +34 917 912 901spainsales@schaffner.comSwedenSchaffner EMC AB
Tegeluddsvägen 76, 2tr115 28 StockholmT +46 8 5050 2425swedensales@schaffner.comwww.schaffner.comSwitzerlandSchaffner EMV AG
Nordstrasse 114542 LuterbachT +41 32 681 66 26switzerlandsales@schaffner.comTaiwan R.O.C.Schaffner EMV Ltd.
20 Floor-2, No 97, Section 1, XinTai 5th Road22175 XiZhi District New Taipei City 22175T +886 2 2697 5500F +886 2 2697 5533taiwansales@schaffner.comwww.schaffner.com.twThailandSchaffner EMC Co. Ltd.
Northern Region Industrial Estate67 Moo 4 Tambon Ban KlangAmphur Muangg P.O. Box 1451000 LamphunT +66 53 58 11 04F +66 53 58 10 19thailandsales@schaffner.comUnited KingdomSchaffner Ltd.
5 Ashville Way, Molly Millars LaneWokinghamRG41 2PL BerkshireT +44 118 9770070F +44 118 9792969uksales@schaffner.comUSASchaffner EMC Inc.
52 Mayfield Avenue08837 Edison, New JerseyT +1 800 367 5566T +1 732 225 9533F +1 732 225 4789usasales@schaffner.comwww.schaffnerusa.comSchaffner North America
6722 Thirlane Road24019 Roanoke, VirginiaT +1 276 228 7943F +1 276 228 7953Schaffner North America
823 Fairview Road24382 Wytheville, VirginiaT +1 276 228 7943F +1 276 228 7258